TCL TAC-09CHSA, TAC-12CHSA, TAC-09CHGI, TAC-12CHGI service manual

TCL
WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL
TAC-09CHSA/GI TAC-12CHSA/GI
No.TE051220
CONTENTS
1. IMPORTANT NOTICE ···································2
2. TECHNICAL SPECIFICATION ·····················3
3. OPERATION DETAILS ·······························4
4. WIRING DIAGRAM ············· 11
5. EXPLOSION VIEW ····························12
6. PARTS LIST ·············13
IMPORTANT NOTICE
TCL Air Conditioner Service ManualTCL Air Conditioner Service ManualTCL Air Conditioner Service Manual
TCL Air Conditioner Service Manual
2
This service manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
The information, specifications and parameter are subject to change due to technical modification or improvement without any prior notice. The accurate specifications are presented on the nameplate label.
How to order spare parts
To have your order filled promptly and correctly, please furnish the following information:
1. Model No. with Indoor or Outdoor
2. No. in the Explosion View
3. Part Name
4. The quantity you ordered
TCL Air Conditioner Service Manual
Technical Specifications
Model No.
Type
Control type
Rated cooling capacity
Rated heating capacity
Moisture removal
High dB(A) 37 38
Med. dB(A)
Indoor noise level at cooling
Outdoor noise level
Electrical Data
Power supply
Voltage Range
Rated current
Rated input
Refrigerating System
Refrigerant/Charge
Compressor
Evaporator
Condenser
Expansion device
Defrosting system
Fan System
Indoor air circulation/Hi Cooling
Indoor fan type
Indoor fan speed H/M/L
Outdoor fan type
Outdoor fan speed
Connections
Refrigerant coupling
Connecting Pipe
Connecting Wiring
Drainage Pipe
Others
Suitable area
Net dimensions Indoor mm 770*240*180 770*240*180
(W x H x D) Outdoor mm 760*560*260 760*560*260
Net weight
Packing dimensions Indoor mm 883*325*271 883*325*273
(W x H x D) Outdoor mm 863*598*381 863*598*383
Gross weight
4×1.5 4×1.5
Low dB(A)
Cooling A 3.6 4.9
Heating A 3.8 5.2
Cooling W 780 1060
Heating W 820 1120
Type
Model
LRA A
MFG
Cooling rpm 1300/1280/1100/950 1330/1300/1150/1000
Heating rpm 1300/1280/1100/900 1320/1300/1100/900
Dry rpm 950 1150
Sleep rpm 950/900 1000/900
Gas Inches 3/8'' 1/2''
Liquid Inches 1/4'' 1/4''
Size x Core number
Indoor kg 8.5 8.5
Outdoor kg 30 34
Indoor kg 10.5 10.5
Outdoor kg 33 37
Btu/h 9,000(3,800~10,500) 12,000(5,200~13,500)
Btu/h 10,250(4,200~13,000) 13,800(5,500~16,500)
Liters/h
dB(A) 52 55
V 158-260 158-260
Gram 410A780g 410A1080g
m3/h 450 480
rpm 850 850
2
m
low temp. start-up -15 -15 high temp. start-up 52 52
TAC-09CHSA/GI TAC-12CHSA/GI
heating pump heating pump
remote remote
Rotary Rotary
DA108X1C-20FZ3 DA108X1C-20FZ3
Toshiba Toshiba
Louver fin and Grooved tube type (φ7)
Corrugated fin and Grooved tube type (φ9.53)
Microcomputer controlled reverse system
Cross Flow Cross Flow
Propeller fan Propeller fan
9-15 12-19
220-240V~/50Hz
Capillary tube
O.D.16mm
Note:The technical specifications is only reference.
3
Operation Details
TCL Air Conditioner Service Manual
5
2
8
4
11
Remote controller
Remote controller
The remote controller transmits signals to the system.
1
SLEEP
TIMER ON
FEEL COOL DRY FAN HEAT
TMIER OFF
AUTO HIGH MID LOW SWING
2
3
3
SLEEP
FAN
7
4
TIMER
MODE
SWING
ON/OFF
6
1
5
6
ON/OFF button
Used to start and stop operation when pressed.
TIMER button
Used to select TIMER operation.
UP button (TOO COOL button)
Used to increase the set room temperature
and time.
DOWN button (TOO WARM button)
Used to decrease the set room temperature and time.
SLEEP button
Used to set or cancel sleep mode operation.
VANE control button
Used to adjust airflow direction.
FAN SPEED control button
7
Used to select the indoor fan motor speed: Auto, High, Mid and Low.
8
MODE button
Used to select the type of operation mode: Feel, Cooling, Dry, Fan and Heating(Only for Heat Pump).
Note: Each mode and relevant function will be further specified in following pages.
Remote Control
The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of
Heat or Cool on LCD of the remote controller. User can preset the remote controller type depending on the air conditioner type you have purchased as follows: Press any button when the arrowhead flashes on the front of Cool , Cooling Only is set. Press any button when the arrowhead flashes on the front of Heat , Heat Pump is set. If you don t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.
Note :
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.
4
TCL Air Conditioner Service Manual

Electronic Controller

1. Safety Protection
(1) Time Delay for Safety protection
z 3 minutes delay for compressor ---The compressor is ceased for 3minutes before
restarting to balance the pressure in the refrigeration cycle in order to protect the
compressor.
z 2 minutes delay for 4-way valve---The 4-way valve will be ceased for 2 minutes late
after compressor to prevent the refrigerant-gas abnormal noise when the HEATING
operation is OFF or switch to the other operation mode.
(2) Discharge temperature protection
There is a temperature sensor on top of compressor, when temperature on top of
compressor exceeded the limit, system control will shut down the compressor and the
display board will show the error code.
(3) lower voltage protection
When AC voltage 158V and keep it for 10 seconds, unit will be shut down for protection.
(4) Over voltage protection
When AC voltage 260V, unit will be shut down and recover while AC≤255V.
(5) Over current protection
When the current of outdoor unit is overload, controller shut down the unit immediately and
show error code.
(6) Compressor abnormity protection
When compressor start on or in the process of running, if there is no feedback to controller
or load of compressor is abnormity, the air conditioner will shut down, and show error
code.
(7) IPM module protection
IPM module has high temperature & over current protection itself, if there is signal
feedback to IPM, the outdoor unit will shut down, LED on outdoor PCB will show the error
code.
2. “I Feel” Mode Operation
(1) When the “I Feel” mode is selected, the operation mode and initial temperature set are
determined by the initial room temperature at start-up of the operation except to turn off the
air conditioner and operates it again.
(2) If the mode is change to “I Feel” from other mode, the “I Feel” mode doesn’t operate until
compressor stop for more than 3 minutes.
Mode
Initial Room Temperature Initial Set Temperature
COOLING
DRY
RT26 23
26℃>RT20 RT-2
HEATING for Heat Pump
FAN for Cooling Only
RT20 -
z In the “I Feel” mode, when the controller receives the up or down signal of temperature,
the set temperature can adjust by 1 upper or lower. The biggest you can adjust by
2 upper or lower.
3. “COOLING” Mode Operation
5
TCL Air Conditioner Service Manual
(1) Compressor frequency control
According to difference room temperature and set temperature(δt = RT-ST), running
frequency of compressor is controlled by electronic controller. When room temperature is much
higher than set temperature, compressor will start at a high frequency, and as room temperature
goes down, compressor running frequency will go down. When room temperature is lower than set
temperature, compressor will run at very low frequency. In general, unit will change its running
frequency according toδt to make room temperature closing to set temperature.
(2) Outdoor temperature affects running frequency of compressor
Outdoor temperature affect compressor’s running frequency. Difference inlet temperature of
outdoor unit is adapted by difference compressor running frequency. While outdoor temperature is about 30℃, the compressor will run in high frequency. If unit run in “cooling” mode and outdoor temperature is less than -1℃,controller will shut down compressor and show error code, while the ambient temperature is over 0℃, the compressor will run automatically.
(3) Auto fan control in cooling mode
In cooling mode (include cooling in “I feel” mode), fan speed is determined by δt, as the
following diagram:
RT-ST
δt come down
δt come up
3.5
high fan
3.0
1.5
midium fan
1.0
low fan
4. “DRY” Mode Operation
(1) The system for DRY operation used the same refrigerant circle as the cooling one.
(2) When the system operates in DRY mode, at first it operates in cooling mode at 16 or
18℃ for 3 minutes. After that, the system will operate in cooling mode with lowest fan
speed, meanwhile the set temperature (ST) is “RT-2 which means that the ST is room
temperature at then minus 2. During the course of this mode, the fan speed set operation
and room temperature set are restricted, except the vane motor adjusting.
5. “HEATING” Mode Operation (available for Heat Pump only)
(1) Frequency control
The same as the frequency control in cooing mode, running frequency of compressor is
controlled by controller. Unit change its running frequency according to δt to make room
temperature closing to the set temperature.
(2) Indoor fan motor control
1. Cold Air Prevention C
ontrol
z The function is intended to prevent cold air from being discharged when the heating
operation starts or when defrosting.
z The indoor fan speed will be controlled as following.
6
Loading...
+ 13 hidden pages