4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors
1 Fiber Optic 100Base-FX Port
MDI/MDIX Auto Detection and Operation on Twisted Pair Ports
Full or Half Duplex Transfer Mode for each Twisted Pair Ports
Multimode (1310nm) and Single Mode (1310nm/1550nm)
Distances up to 80km
Hardened Temperature (optional), -40°C to 80°C
Standalone or Rackmount
TC3705
10/100Base-T Ethernet Fiber Optic Switch
User's Manual
TC3705 User's Manual
Rev. 1.2
Alarm Relay
2. Standards
IEEE 802.3, 802.3u, and 802.3x
3. Description
Featuring distances up to 80km, the TC3705 10/100Base-T Ethernet Fiber Optic Switch provides a 100BaseFX port that combines Ethernet Switching and Fiber Optic technology to boost total network bandwidth.
The TC3705 offers one multimode (1300nm) or single mode (1300/1550nm) optical port and four Ethernet
10/100Base-T Auto-Sensing/Auto-Negotiation switched ports. Each of these ports supports either 10BaseT or 100Base-TX. There are two optional versions (Model TC3705T) for extreme temperature applications
(-20C to 70C, -40C to 80C).
Because it functions like an Ethernet bridge (connects multiple Ethernet segments to prevent unnecessary
network traffic), it creates an efficient sub-divided switched LAN that provides full and transparent
bandwidth for each segment.
The TC3705’s modern switching technology eliminates the congestion problem inherent to the contentionoriented Ethernet CSMA/CD protocol. This improves predictable response times under heavy network
loads. Previously, expensive routing technology was used to alleviate congestion from heavy traffic
loads.Power is 12VDC, optional 24VDC, -48VDC, 125VDC, or 115/230VAC with an external power cube.
Units are standalone or 19" rack mountable. Optical connectors can be SC, ST or FC.
4. Electrical Specifications
Data Rates:10Mbps/100Mbps auto negotiation
Connectors:RJ-45 Female
5. Temperature
Operating..............................................................................................................................-10oC to 50oC
TC Communications, Inc. 17881 Cartwright Road - Irvine, CA 92614
Loss Budget:1310nm/1550nm Single Mode, @9/125µm: 29 dB
Distance:1310nm/1550nm Single Mode, @9/125µm: up to 50km distance
Wavelength:1310nm/1550nm Single Mode:
Connector:SCOnly
−3−
Page 4
7. Connectors and LED Indicators
+ -
Dry Contact Relay
is needed.
for the twisted pair connection.
LED Status Indicators for
Twisted Pair Ports 1 through 4:
port is operating at 100Mbps.
-when the Twisted Pair port is
when there is Ethernet Activity.
and 5V voltage regulated
f r o m p o w e r A a n d p o w e r B .
LED Status Indicators
for Fiber Optic Channel:
100M
A l w a y s l i t .
-
100M
- when the Twisted Pair
S o l i d l y l i t
TC3705 User's Manual
Rev. 1.2
FULL/COL Full Duplex/Collision
Indicator LED:
-
LINK/ACT
has established a valid optical link.
- when the optical fibers
are not connected.
at the fiber optic port is detected.
-
A l w a y s l i t .
S o l i d l y l i t
- when the fiber optic port
“ Of f”
“ B l i n k i n g ”
when Ethernet Activity
“ O f f ”
operating at 10Mbps.
FULL/COL Full Duplex/Collision
Indicator LED:
- “ when the port is operating
at full duplex.
at half duplex.
- “when collisions occur.
LINK/ACT
Pair port has established a valid link.
-
P r i m a r y o p t i c
Receiver and Transmiter
-
Solidly lit”
when the port is operating
“ O f f ”
B l i n k i n g ”
- “ when the Twisted
Solidly lit”
“ B l i n k i n g ”
L E D I n d i c a t o r s f o r :
P o w e r A , P o w e r B
Figure 1. TC3705's Front Panel
+ -
Redundant power supply
input. Only one power supply
Figure 2. TC3705's Rear Panel
(Normal Open)
Four RJ-45 10/100Mbps Ports
−4−
Page 5
TC3705 User's Manual
T y p i c a l a p p l i c a t i o n u s i n g T C 3 7 0 5 E t h e r n e t F i b e r O p t i c S w i t c h e s c o n n e c t i n g t w o L A N s .
Rev. 1.2
8. Typical Application Diagram
The TC3705 10/100Mbps Ethernet Switch is a low cost and flexible solution to extend a local area network
to a remote site through fiber optic cables. Providing bandwidth solution to efficiently handle the traffic
between the local and the remote workgroups of the network and reducing the need of expensive routers
that usually cater to the network backbone.
This application diagram shows a network connection between two LANs. Extend PC lines from a server
over fiber or have a telephone "hotlink" using our TC1910's as shown on the diagram. By connecting two
TC1910's to the Twisted Pair ports and using regular telephone sets, the users at both sides of the fiber link
can have a hotlink phone line setup. When one user lift up the handset, the remote side phone will start to
ring. When remote side user pickup the handset, the phone stop to ring and the conversation begins.
M u l t i m o d e o r S i n g l e M o d e
Fiber Optic Cables
Figure 3. Typical Application Diagram for the TC3705's
−5−
Page 6
TC3705 User's Manual
Rev. 1.2
9. Hub Topology Diagram
You can use the TC3705's for a variety of network configurations. For example, connect up to four hubs or
switches to develop workgroups with dedicated 10/100Mbps links. Connect your routers, printers, servers,
and other network devices.
Multimode or Single Mode
Fiber Optic Cables
Figure 4. Backbone Using an Extended Star Topology with the TC3705's
−6−
Page 7
TC3705 User's Manual
Rev. 1.2
10. Power Requirements
A. The TC3705's input voltage is 12V DC and current is 600mA.
B. The TC3705's power connectors are two terminal blocks located on the rear panel of the unit. Polarity
is indicated on each connector block (see Figure 2).
C. Should an external power adapter need to be replaced, use one with the following specifications: 12V
DC @600mA. You may order it directly from TC Communications.
D. The TC3705 can also be ordered with an optional 24 VDC, 48 VDC or power supply. Current
consumption at 24VDC is 300mA, at 48VDC is 150mA, and at 125VDC is 60mA.
11. System Start Up
1. Apply the power by plugging the power plug into any power jack on the rear panel. The power source
can be from a power adapter or from a power card (installed either on the left or right side of the rack).
2. The "PWR A" or "PWR B" LEDs on the front panel will light according to which power jack (A or B)
is connected. Both LEDs will light when power redundancy is utilized.
3. The "Vcc" LED should also light, indicating an adequate operating voltage is being derived from the
power source.
4. Connect the twisted pair cables to the RJ-45 connectors on the rear panel of the switches. If the twisted
pair cables are providing an Ethernet signal, then the corresponding front LEDs for that particular
channel will light as follows:
a). If 100Mbps full duplex is detected by the switch, the 100M & FULL/COL LEDs will be solidly lit and
the LINK/ACT will blink as activity is detected.
b). If 10Mbps full duplex is detected by the switch, the 100M LED will be "Off" and the FULL/COL
LED will be lit.
c). If half duplex and collisions are detected by the switch, the FULL/COL LED will be blinking.
5. Connect the optical fibers from the Tx connector of one unit to the Rx connector of the second unit, the
LINK/ACT LED of the fiber port on the second unit will be solidly lit. Do the same for the second pair
of Rx to Tx connectors and observed the LINK/ACT LED on the first unit will be lit.
7. When communication is established and traffic passes through the fiber between two TC3705's the
LINK/ACT LED will blink.
−7−
Page 8
TC3705 User's Manual
Rev. 1.2
12. Dry Contact Relay Alarm (optional)
A terminal block connector on the rear panel (labeled "ALARM")
provides for the optional dry contact relay alarm (see Figure 2).
Normally in the OPEN position, any loss of optical signal will
trigger an alarm condition and force the switch to the CLOSED
position. This relay can be used in conjunction with an external
device to monitor the condition of the fiber optic links.
Dry Contact Alarm Condition:
When the front panel LINK/ACT LED is lit and/or blinking, the TC3705 is working well and thus it is not
in Alarm Condition. Otherwise, if the LINK/ACT LED is "Off" the TC3705 will be in Alarm Condition and
the Dry Contact Relay will be activated.
A. "PWRA" and/or "PWRB" LEDs should be on when power is connected. If both are "Off," then no DC
power is reaching the unit. Check the power supply, source, and polarity.
B. If "PWRA" and/or "PWRB" LEDs are "On" but all other LEDs are "Off", and the Alarm switch is not
closed, it indicates an internal problem with the unit. For assistance, please contact the Technical Support
Department at TC Communications @ (949) 852-1973.
Electrical Problem:
If All LEDs, 100M, FULL/COL, and LINK/ACT, are OFF:
It means that there is no ethernet electrical signal detected by the TC3705. Check the twisted pair cables
for good connectivity. Make sure that the units have adequate power.
Optical Problem:
If the 100M and FULL/COL LEDs are lit, and the LINK/ACT LED is OFF:
A. Check the physical fiber optic cable connection to make sure it is not loose or broken.
B. Optic "Tx" is connected wrongly to another TC3705's "Tx."
C. Optic cable type is incorrect. Typically, fiber optic cable with yellow-colored insulation is designated for
Single Mode use @8.2µm or 9µm; orange or gray-colored cable is for Multimode use @50µm or 62µm.
If the wrong cable type is used, the unit will not function properly.
15. Frequently Asked Questions
1) What kind of Ethernet cable should I use?
Ans:Use RJ-45 standard CAT. 5 or 5E Ethernet cable. Because all twisted pair ports on the
TC3705 are MDI/MDIX Auto-Detection and Operation, you can use either straight
through(patch cable) or cross-over cable.
−8−
Page 9
TC3705 User's Manual
Rev. 1.2
16. Warranty & Return Policy
Return Policy
To return a product, you must first obtain a Return Material Authorization number from the Customer
Service Department. If the product’s warranty has expired, you will need to provide a purchase order to
authorize the repair. When returning a product for a suspected failure, please provide a description of the
problem and any results of diagnostic tests that have been conducted.
Warranty
Damages by lightning or power surges are not covered under this warranty.
All products manufactured by TC Communications, Inc. come with a five year (beginning 1-1-02)
warranty. TC Communications, Inc. warrants to the Buyer that all goods sold will perform in accordance
with the applicable data sheets, drawings or written specifications. It also warrants that, at the time of sale,
the goods will be free from defects in material or workmanship. This warranty shall apply for a period of
five years from the date of shipment, unless goods have been subject to misuse, neglect, altered or destroyed
serial number labels, accidents (damages caused in whole or in part to accident, lightning, power surge,
floods, fires, earthquakes, natural disasters, or Acts of God.), improper installation or maintenance, or
alteration or repair by anyone other than Seller or its authorized representative.
Buyer should notify TC Communications, Inc. promptly in writing of any claim based upon warranty, and
TC Communications, Inc., at its option, may first inspect such goods at the premises of the Buyer, or may
give written authorization to Buyer to return the goods to TC Communications, Inc., transportation charges
prepaid, for examination by TC Communications, Inc. Buyer shall bear the risk of loss until all goods
authorized to be returned are delivered to TC Communications, Inc. TC Communications, Inc. shall not be
liable for any inspection, packing or labor costs in connection with the return of goods.
In the event that TC Communications, Inc. breaches its obligation of warranty, the sole and exclusive
remedy of the Buyer is limited to replacement, repair or credit of the purchase price, at TC Communications,
Inc.’s option.
To return a product, you must first obtain a Return Material Authorization (RMA) number and RMA form
from the Customer Service Department. If the product’s warranty has expired, you will need to provide a
purchase order to authorize the repair. When returning a product for a suspected failure, please fill out RMA
form provided with a description of the problem(s) and any results of diagnostic tests that have been
conducted. The shipping expense to TC Communications should be prepaid. The product should be properly
packaged and insured. After the product is repaired, TC Communications will ship the product back to the
shipper at TC's cost to U.S. domestic destinations. (Foreign customers are responsible for all shipping costs,
duties and taxes [both ways]. We will reject any packages with airway bill indicating TC communications
is responsible for Duties and Taxes. To avoid Customs Duties and Taxes, please include proper documents
indicating the product(s) are returned for repair/retest).
−9−
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.