Although every effort has been made to insure that this manual is current
and accurate as of date of publication, no guarantee is given or implied
that this document is error free or accurate with regard to any specification. TC Communications, Inc. reserves the right to change or modify
the contents of this manual at any time without prior notification.
TC Communications, Inc. 17881 Cartwright Road - Irvine, CA 92614
Front Panel.......................................................................................................................................... 5
General ..............................................................................................................................................12
All LEDs are Off................................................................................................................................12
Alarm LED .........................................................................................................................................12
General ..............................................................................................................................................14
Test Equipment Requirements ......................................................................................................14
The Model TC1630R/S is a T1/E1 Fiber Optic Modem that converts analog T1 or E1 signals to digital fiber
optic signal and vice versa. TC1630R is for 19" rackmount and TC1630S is for standalone unit. Both have
the same functions and features, the only difference is power connectors. For convenience, TC1630R/S and
TC1630 will be used interchangeably throughout this manual.
TC1630 offers advanced features such as digital transmission, jitter removal and a field replaceable Line
Interface Module. Because it is based on modern FPGA (Field Programmable Gate Array) technology, the
IC chip counts are reduced to a minimum, hence offering extremely low power consumption (less than 3
watts) and higher reliability.
Transparent to the framing format, the TC1630R/S’s T1/E1 interface shapes the transmit pulse to support
CCITT G.703, or, for connecting to DSX-1 cross connects, copper line distances are from 0 to 655 feet. The
internal elastic buffer removes jitter from transmit data.
The TC1630R/S has multiple LED indicators to ease installation and troubleshooting. These LEDs indicate
power, operating voltage, alarm status, local and remote T1/E1 signal loss, bipolar violations, all ones warning,
Optic signal sync active and more. Eight DIP switches, accessible from the front panel, control settings for
Line Code, Line Length, Local Loopback and Remote Loopback. The dry contact alarm relay switch
provides remote alarm monitoring capability.
The TC1630R/S is compatible with all types and sizes of fiber optic cable. Fiber optic connectors are ST
(optional FC). T1 or E1 signal can be connected to two pairs feed-thru detachable terminals or a RJ-48C
connector at the rear panel. Input power is 12V DC or 115/230V AC with an external power cube. Alternate
power sources are available as an option (see Chapter 6 - Specifications).
Note: The terms "TC1630R/S" and "TC1630" are used interchangeably in this manual.
ALM:Alarm indicator. The Alarm LED will light when following conditions occur:
The unit is in a diagnostic mode.
When an invalid line code or line length is set.
Optic signal is lost.
Local T1/E1 signal is lost or all ones signal is received from customer's device.
Remote T1/E1 signal is lost.
When the "Line Distance" setting is set as "1 0 0" (when SW5 is on, and both SW4 and SW3 are
Off).
Power Supply Status-
Power A/B: These LEDs indicate which power source on the rear panel the unit is drawing from. If power redundancy is
utilized, both LEDs will light.
Vcc:+5V Voltage indicator. This LED should light whenever power is connected to the unit. It indicates the
correct operating voltage is being derived from the power source.
Optic Signal Status-
RxOPT:Solidly lit, it indicates optical signal received.
Flashes when the optical signal is lost.
SYNC:Indicates a valid composite signal is being received.
Configuration Setting-
AMI/B8ZS/HDB3: These LEDs indicate the T1/E1 line code setting (SW6, 7, 8).CSU: Channel Service Unit indicator. This
LED will be lit whenever the minimum T1 Line Length is set (see Configuration Table - page 10).
133-655/CSU: These LEDs indicate the T1 Line Length distance setting (SW3, 4, 5).
Local T1/E1 status and warning-
LAIS:When flashing, it indicates "all ones" signal received from user's equipment.
LLOS:When flashing, it indicates the loss of the T1/E1 signal from local user's equipment.
BPV:Bipolar Violation LEDs. These LEDs light when bipolar violations (Line Code violations) are detected. The
severity of the violation is represented by three LEDs. Higher BPV rates cause more LEDs to light.
LOC: Indicates the Local Loopback function is enabled (SW2 is On).
Remote T1/E1 status and warning-
RLOS:When flashing, it indicates the loss of the T1/E1 signal from remote user's equipment. This LED will be Off
when no fiber cable is connected or the fiber cable is bad.
RMT:Indicates the Remote Loopback function is enabled (local SW1 is On).
- 5 -
Page 6
TC1630R/S User's Manual
ON
123
4
567
8
Rev. 2.5
DIP Switch Functions
Slide switch to the Right (On) position to activate the function.
1 2 3 4
1 2 3 4
RMTLB
LOCL B
LEN2
LEN1
LEN0
HDB3
B 8ZS
A MI
AMI/B8ZS/HDB3: These switches select the Line Code (see Figure 5).
LEN0/LEN1/LEN2: These switches define the DSX-1 cross connect distance. There are 5 partitions to
choose from. In a T1 application, this is the length of twisted pair cable connecting the TC1630R/S to the
user's equipment, which may be a CSU or DSU. The cable lengths can be from 0 to 655 feet (see Figure
5).
Local LBT: This switch initiates the Local Loopback function. The T1/E1 signal is received and decoded,
then looped back to the T1/E1 "out" terminals for diagnostic testing.
Remote LBT: This switch activates remote unit into Remote Loopback function. The composite optic
signal is transmitted to remote unit and decoded, then looped back to local unit.
Fiber Optic Specifications
Transmission Distances (typical)
The TC1630R/S is compatible with all popular sizes and types of fiber. Transmission distances up to 3km*
are typical over Multimode fiber at 850nm and 4km* at 1310nm. Distances to 35km* are typical over Single
Mode fiber at 1310nm.
Launch Power & Sensitivity
Transmitter:LED/ELED; typical Launch Power --19dBm* (850nm/1310nm MM, @62.5/125µm)
-15dBm* (1310nm Single Mode, @9/125µm)
Receiver:PIN Diode; typical Sensitivity --35dBm* (850nm/1310nm MM, @62.5/125µm)
-35dBm* (1310nm Single Mode, @9/125µm)
*Launch power, sensitivity and distance are listed for reference only. These numbers may vary. Contact factory for
higher loss budget requirements.
* Note 1:The T1/E1 signal can be connected to either the terminal block connectors or the RJ-45F
connector as shown above on the rear panel, but not on both at the same time.
* Note 2:The T1/E1 signal is bipolar, independent of the polarity. Polarity on the "IN" & "OUT" terminal
block connector shown above is shown for reference only.
Figure 3. TC1630S Rear Panel
- 7 -
Page 8
TC1630R/S User's Manual
Replaceable T1/E1
to T1/E1 line
from T1/E1 line
TC1630R/S
External DIP Switches (accessible from front panel)
Line
Code
Rev. 2.5
Functional Description
As shown in figure 4, the TC1630 consists of five basic function blocks: DIP switches, LEDs, T1/E1
interface, T1/E1 signal processor and optic interface.
DIP switches are used to configure the TC1630 according to a customer's application such as line code and
line distances. LEDs are used to display corresponding DIP switches settings, power supply status, optic
signal status, signal warnings, alarm, etc... the T1/E1 interface converts T1/E1 analog signals to digital
signals and provides local and remote loopback function. The signal processor composes T1/E1's timing and
data to a bit stream. The optic interface converts the electrical bit stream to an optic signal and vice versa.
to optic
cable
RxA
TxA
Optic interface
Power
Vcc Alarm Optic
A,B
Remote
Local
Loop
Loop
Test
Test
B8ZS/HDB3
T1/E1 Signal Processor
Local
Loss
Remote
Loss
Sync
LED Indicators on front panel
AMI or
Local
Loop
back
Remote
Loop
back
Line Length
1,2,3
All
Ones
Warning
Bipolar
Violation
Setting
line Interface Module
Elastic Buffer
Line DriverLine Receiver
Line
length
Setting
Figure 4. TC1630R/S Functional Diagram
- 8 -
Page 9
TC1630R/S User's Manual
Rev. 2.5
Chapter 2 - Installation
Unpacking the Unit
Before unpacking any equipment, inspect all shipping containers for evidence of external damage caused
during transportation. The equipment should also be inspected for damage after it is removed from the
container(s). Claims concerning shipping damage should be made directly to the pertinent shipping agencies.
Any discrepancies should be reported immediately to the Customer Service Department at TC Communications, Inc.
Equipment Location
The TC1630R/S should be located in an area that provides adequate light, work space, and ventilation. Avoid
locating it next to any equipment that may produce electrical interference or strong magnetic fields, such as
elevator shafts or heavy duty power supplies. As with any electronic equipment, keep the unit from excessive
moisture, heat, vibration, and freezing temperatures.
Power Supply
The TC1630S is powered by an external DC power adapter rated 12VDC @250mA. There are two power
jacks at the rear panel for power redundancy. TC1630R is the rackmount version of the TC1630S. It can
be inserted into the card slot when power is on (hot swapable).
T1/E1 Connection
Two pairs of terminal block connectors and/or an RJ-45F connector are provide for the connection of the
T1/E1 wire pairs. When viewing the rear panel, the left pair of terminal block connectors are for T1/E1 signal
going into the TC1630R/S (receive), while the right pair of terminal block connectors are for the transmit
signal coming out of the unit. Note: The T1/E1 signal can be connected to either the terminal block connectors
or the RJ-45F connector, but not on both at the same time, refer to page 7.
Dry Contact Alarm Switch
A terminal block connector at the rear panel provides for the Dry Contact Relay Alarm. Normally in the
CLOSED position, any alarm condition will force the switch to the OPEN position. This relay can be
configured by the user if necessary (see Chapter 3 - Troubleshooting).
Installation Procedure
The TC1630R/S is designed for quick and easy installation. First, configure the modem for your specific
application by setting the Line Code and Line Length DIP switches. Once configured, you can connect the
optical, T1/E1 signal source and power.
Installation Procedure:
1. Select the Line Code (SW6, 7, 8).
2. For T1, select the Line Length (SW3, 4, 5).
3. Connect the T1/E1 signal source, either terminal blocks or RJ-48C connector.
4. Connect the optic cables. Verify single mode or multimode optic cable according to your TC1630
ordered. Using incorrect optic cables will result in a malfunction. Verify optic connections.
5. Connect the power. All the LEDs should flash for approximately three seconds.
After installation is completed, it is an excellent idea to verify the optical cable loss. This reading will both
verify the integrity of the circuit and provide a benchmark for future troubleshooting efforts.
- 9 -
Page 10
TC1630R/S User's Manual
Rev. 2.5
TC1630R/S's Configuration
1. Select the application's Line Code: SW6, 7 or 8. Slide the appropriate switch to the Down (On) position.
AMI: set SW8 to the Down (On) position.
B8ZS: set SW7 to the Down (On) position.
HDB3: set SW6 to the Down (On) position.
Only one of the above switches should be selected, as any two switches in the Down (On) position will cause
the "Alarm" LED to flash.
2. Select the Line Length setting for T1: SW3, 4, 5 (see Figure 5). Slide the appropriate switches to the
Down position.
Depending on the distance between the TC1630R/S and the T1 cross connect, set the Line Length for the
T1 transmit line driver according to the table below. When connecting to DSX-1 cross-connects for Line
Lengths ranging from 0 to 655 feet, see DIP Switch Functions on page 6. There is no need to set the Line
Length for E1 applications; set SW3, 4, and 5 to the Up (Off) position.
Note: The “Line Length” setting “1 0 0” is invalid. If “Line Length” is set as (1 0 0), then the Alarm
LED will flashes, indicating the setting is invalid.
3. Connect the T1 or E1 signal.
T1 signal connection for 100 ohm line: Connect the incoming T1 signal (from your equipment) to the "in"
terminal blocks on the rear panel; they are not polarity sensitive. A valid T1 signal will cause the "LLOS"
LED turn to off. Connect the outgoing T1 signal (received from the optical cable) to the "out" terminal blocks.
E1 signal connection (The E1 interface can be used for either 75 or 120 ohm line - see Appendix A):
75 ohm line: Connect the incoming signal (from your equipment) to the "in" BNC adapter. Connect the
outgoing signal (received from optical cable) to the "out" BNC adapter.
120 ohm line: If twisted-pairs are used, connect the wires in the same way as the T1's wire. If dual coaxial
is used, connect the cores to the "in" terminal blocks for the incoming signal and to the "out" terminal blocks
for the outgoing signal (each cable has two cores & a shield).
4. Verify optical connections:
Make sure the local TC1630's optic "Tx" is connected to the remote TC1630's optic "Rx" (and vice-versa).
5. Connect power to both units.
System Start Up
When power is initially connected, the following conditions should be observed:
1. The "POWER A" and/or "B" LED is lit.
2. The "LLOS" LED is Off, indicating a valid T1 or E1 signal input.
3. The "ALARM" LED should be Off.
Start the T1/E1 signal transmission:
4. The "POWER A" and/or "B" LED stays lit.
5. The "SYNC" LED should be lit, indicating a valid received optic signal.
6. One of the line length LED should be lit. If "133" is selected, "CSU" LED should be lit too.
Note: If the modem is not functioning properly at this point, please refer to Chapter 3 - Troubleshooting.
- 11 -
Page 12
TC1630R/S User's Manual
Rev. 2.5
Chapter 3 - Troubleshooting
General
Alarm conditions occur whenever an optical problem or "fault" condition is detected by the TC1630.
All LEDs are Off
If no LEDs are lit on the unit, check the DC power supply, terminal block connector plug, change to alternate
power jack on the rear panel, fuses A and/or B indicated on page 17, and/or the power source. If the problem
persists, contact the Technical Support Department at TC Communications, Inc.
Alarm LED
When an alarm condition is detected, the Alarm LED will flash. The following fault conditions will cause
the alarm to be triggered:
1. Optic signal lost from optic "Rx."
2. Optic signal is marginal, which causes invalid data packets to be received; the "SYNC" LED will be "Off."
3. Received "space" or "mark" from local T1/E1 device.
4. An invalid Line Code setting exists.
5. The Line Length setting does not match the Line Code.
6. The local or remote T1/E1 signal is lost; the "LLOS" or "RLOS" LED will be also be flashing.
Note: The "RLOS" LED will be Off when there is no fiber cable connected or the fiber cable is bad.
Optic Cable Types
Conventionally, fiber optic cable with yellow-colored insulation is used for Single Mode applications; gray
or orange-colored insulated cable is for Multimode use. If Multimode cable is used in a Single Mode
application, the test results could be erroneous and confusing.
Calculating the Loss on the Fiber
The fiber optic link and/or connectors are frequently the source of various problems. Check out the
connectors and the integrity of the link first. Ideally, the link should be calibrated for total loss after the
installation has been completed. This will accomplish two things: (1) it will verify that the total loss of the
link is within the loss budget of the device and (2) it will provide a benchmark for future testing. For example,
a system that has been tested as having 6dB total loss when installed and suddenly tests out as having a loss
of 10dB probably has a connector or link problem.
These are the reference values we used to calculate loss on the fiber :
Multimode 850nm:3 dB loss per km on 62.5/125µm cable*
Multimode 1310nm:2 dB loss per km on 62.5/125µm cable*
Single Mode 1310nm:0.5 dB loss per km on 9/125µm cable*
Single Mode 1550nm:0.25 dB loss per km on 9/125µm cable*
*These numbers are listed for reference only. We recommend an OTDR reading be used to determine actual link loss.
- 12 -
Page 13
TC1630R/S User's Manual
Rev. 2.5
Cable Connection Verification
Electrical Cables:
1. Make sure all electrical signal connections match the pin assignments (I/O) for the device (check User's
Manual if necessary).
2. Verify signal connections by checking the status LEDs on the front panel of the TC1630R/S. If the
"LLOS" LED is flashing, a transmit signal is not being detected from the local device. If the "RLOS"
LED is flashing, no response signal is being detected from the remote device.
3. Verify that the correct Line Code setting (and Line Length setting for T1) has been configured and that
the appropriate LEDs light to match the setting selected.
4. Conduct a Local Loopback Test to help isolate an electrical interface problem (see Chapter 4 - Bench
Tests).
Optic Cables:
If the "SYNC" LED on the front panel is flashing or Off, this is an indication that the optic signal is not being
correctly received. Usually, unsecured fiber optic connectors or faulty cable are to blame. A good
connection is indicated by the "SYNC" LED on the front panel being solidly lit. This indicates that the
receiving cable is correctly connected to Remote unit's optic "Tx."
Dry Contact Alarm Relay
TC1630 has built-inDry contact relay switch. The status is for the relay switch is "normal open". It is
triggered by following major alarm conditions:
Optic signal lost
Local T1/E1 signal lost
Local user's T1/E1 device is sending "mark" data pattern
Local user's T1/E1 device's signal is causing bipolar violations
Invalid line code setting
Invalid line length setting
The electrical rating for the dry contact relay switch is
50VDC max
500 mA max.
switching power is 10 watts max.
- 13 -
Page 14
TC1630R/S User's Manual
Local Loopback
IN
Optic Rx
Optic Tx
Rev. 2.5
Chapter 4 - Bench Tests
General
It is highly recommended to conduct bench tests before actual installation. Bench testing allows the user to
become familiar with all the functions and features of the TC1630 in a controlled environment. Knowledge
of the TC1630's functions and features will ease installation and troubleshooting efforts later on.
Test Equipment Requirements
End-user equipment required for testing:
1. Model 5575A T1 Micro BERT (Bit Error Rate Tester) Test Set with Terminal Block Connectors.
2. Two optical cable jumpers (patch cords) with appropriate connectors.
Pre-Installation Tests
1. Make sure the appropriate power supply accompanies the TC1630R/S unit (see page 9).
2. To verify that the unit functions properly, connect power to the unit's "PWR A" or "B" terminal blocks
(be sure to observe correct polarity) without connecting any other cables to the unit.
3. On the front panel, the appropriate green Power "A" or Power "B" LED should be illuminated (depending
on whether you plug into the "A" or "B" terminal on the back of the unit). Both lights should be on if you
utilize power redundancy (power is plugged into both "A" and "B" on the rear panel).
4. The "ALARM" and "LLOS" LEDs should be flashing.
5. The "Vcc" LED should be illuminated. Please note: all other LEDs can be in a random state (flashing,
solidly lit, or off) as only upon proper receipt and transmission of a signal will the TC1630R/S unit set its
LEDs appropriately for normal operation. Proceed to the Local Loopback Test.
Local Loopback Test
The purpose of this test is to verify 1) the signal source recognition and 2) the connection between the
incoming signal and the TC1630R/S's terminal blocks.
1. Make sure your BERT tester is turned on and configured with the same setup as the TC1630R/S (and
your application).
2. Plug in the terminal blocks from the BERT tester to the TC1630R/S’s connectors on the rear panel.
When the input and output are connected correctly, the "LLOS" LED on the TC1630R/S will turn Off.
3. Slide SW2 (LOCAL LBT) to the Down (On) position. The "LOC" LED should flash on the front panel.
4. Make sure the "TERM" or "BRIDGE" LED on the tester is lit, and that the tester is in the "RUN" mode.
The tester should indicate a "SYNC" signal.
5. If any other LEDs illuminate or flash, make sure that all
DIP switches on the TC1630R/S are in the correct
OUT
T1/E1 Line
Interface
Local loopback
position, then reset the BERT tester. You should not see
any bit errors. To verify this, inject an error using the
BERT tester to see if it will be recorded by the tester,
then verify that no additional errors appear after the user
injected error. Proceed to the Optical Loopback Test.
T1/E1
BERT
Tester
- 14 -
Page 15
TC1630R/S User's Manual
Local Optic Loopback
Optic Local loopback
Remote Optic Loopback
IN
Remote Optic loopback
T1/E1 Line
Rev. 2.5
Optical Loopback Test
At any time you may use a short optic cable to loopback the unit's Optic "Tx" to "Rx." The "SYNC" LED
on the front panel should light (solid) when a good optic signal is received. This test verifies the optic
transmitter's function as well as the receiver's. Upon successful completion of this test, proceed to the
Remote Loopback Test.
T1/E1
BERT
Tester
T1/E1 Line
IN
OUT
Interface
Optic Rx
Optic Tx
Remote Optic Loopback Test
1. Connect a second TC1630R/S unit. As with the first unit, follow the bench test steps on the previous
page. When you have completed the Local Loopback & Optical Loopback tests for the second unit,
proceed to the next step.
2. Remove the optical jumper cable from the local unit's "Rx" and connect it to the second unit's optic "Rx."
Add a second optical jumper cable to connect the local unit's "Rx" to the second unit's "Tx."
3. Verify that both TC1630R/S units have the same Line Code and Line Length settings.
4. On the local TC1630R/S, slide SW1 (Remote Loopback) to the Down (On) position. The "RMT" LED
on the remote TC1630R/S's front panel should flash, as well as the "LLOS" and "ALM" LEDs.
5. Make sure the "TERM" LED on the tester is lit, and that the tester is in the "RUN" mode. The tester
should indicate a "SYNC" signal.
6. If any other LEDs illuminate or flash on the unit, make sure that all DIP switches on both of the TC1630's
are in the correct position, then reset the BERT tester. You should not see any bit errors.
7. At this point, both units tested will have passed all electrical and optical tests and will have been verified
that they are functioning properly. Proceed to the next TC1630 unit to be tested or begin verifying other
equipment and cabling in your application (if you have not already done so).
**Contact factory for requirements higher than 20dB.
- 17 -
Page 18
TC1630R/S User's Manual
Rev. 2.5
Appendix A
The E1 interface impedance on the TC1630R/S is user configurable by changing the jumpers on the interface
module. Please follow the instructions below to set the E1 impedance appropriately.
Setting the E1 Interface Impedance
1. Unscrew the 2 front panel screws and slide the unit out of it's housing.
2. Locate the interface module at board location JP2 (the board plugs vertically into the main board's socket).
3. For 75 ohm impedance, the jumpers on the interface module should be set as follows:
The user's device may have a DB15 or RJ45 connector. The following connection diagrams illustrate the
signal flow direction and pin assignments typically used with these connectors.
Note: The polarity of the T1/E1 signal is bipolar, independent of the polarity. Polarity is shown for reference
only.
User's Device
DB15 Connector
Connectors
12345678
9101112131415
(Transmit to Network)
(Transmit to Network)
(Receive from Network)
(Receive from Network)
Note: Pins 7, 8, 12, 14 and 15 are not used on the DB15 connector. Pins 5, 6, 10 and 13 are reserved for Telco use.
Figure 9. DB15 Connection Diagram
RJ45 Connector
1
2
3
4
5
6
7
8
(Transmit to Network)
(Receive from Network)
(Receive from Network)
Connectors
Note: Pins 3 and 6 are not used on the RJ45 connector. Pins 7 and 8 are used for optional shield connections.
Figure 10. RJ45 Connection Diagram
- 19 -
Page 20
TC1630R/S User's Manual
Secondary power card
Rev. 2.5
Appendix C
19" Rack with Dual Power Cards
The picture shows the 19" rack with dual power supply cards. It consists of two subassemblies; TCRM192D-48 which is the 19" rack with dual 48VDC to 12VDC power cards and the TCRM192-BKPL, which is
the power back plane. The power card can be ordered for universal AC input or 24VDC input. The output
of each kind of power card is 12VDC, different input voltage has different output power rating. They are
listed as following:
TCRM192-D-48: 19" rack with dual power cards, each has 48VDC(36-75VDC) input, 12VDC output and
150 Watts.
TCRM192-D-24:Same as above but with 24VDC(18-36VDC) input, 12VDC output and 100 Watts output
power.
TCRM192-D-01:19" rack with dual power cards, each has universal AC input (90VAC to 240VAC, 50Hz
to 60Hz) with 12VDC output. Maximum output power is 65 Watts. The diagram on the next page shows
the equivalent circuits.
The add-on subassembly to the 19" rack is TCRM-bkpl, which is a power strip PCB connected to both power
cards via two pair cable assembly. This power back plane has built-in fuses and power indicators to ease
installation and trouble-shooting.
Primary power card
Power indicators
for power A,B
Fuse A,B
for primary
power card
Fuse A,B
for secondary
power card
Power indicators
for power A,B
48(24)VDC input
for primary
power card
AC power input
for primary
power card
48(24)VDC input
for secondary
power card
AC power input
for secondary
power card
- 20 -
Page 21
TC1630R/S User's Manual
B-B+A-A++-+_+_-++_+
_
OUTPU
T
ER CARD
TC1630 RACKMOUNT POWER SUPPLY
MAX OUTPUT POWER: 150
W
48 VDC12 VDC12 VDC12 VDC12 VDC12 VD
C
+_+-_+_+-
+
FUSE BFUSE AINPUT
+
_
Rev. 2.5
B+
A-
PWR B
PWR A
A+
GND
POWER BACKPLANE
EDGE CONNECTOR TO
A+A-B+
B-B-
GND
FUSE A
FUSE B
PWR B
PWR A
A+
A-B-B+
OUTPUT
48 VDC
12 VDC
12 VDC
12 VDC
12 VDC
12 VDC
POWER CARDPOW
TC1630R CARD (10 X)
- 21 -
INPUT @36-75V
INPUT
OUTPUT @12V + 1% , (5 OUTPUTS)
Page 22
TC1630R/S User's Manual
Rev. 2.5
Appendix D
Return Policy
To return a product, you must first obtain a Return Material Authorization number from the Customer
Service Department. If the product’s warranty has expired, you will need to provide a purchase order to
authorize the repair. When returning a product for a suspected failure, please provide a description of the
problem and any results of diagnostic tests that have been conducted.
Warranty
Damages by lightning or power surges are not covered under this warranty.
All products manufactured by TC Communications, Inc. come with a five year (beginning 1-1-02)
warranty. TC Communications, Inc. warrants to the Buyer that all goods sold will perform in accordance
with the applicable data sheets, drawings or written specifications. It also warrants that, at the time of sale,
the goods will be free from defects in material or workmanship. This warranty shall apply for a period of
five years from the date of shipment, unless goods have been subject to misuse, neglect, altered or destroyed
serial number labels, accidents (damages caused in whole or in part to accident, lightning, power surge, floods,
fires, earthquakes, natural disasters, or Acts of God.), improper installation or maintenance, or alteration or
repair by anyone other than Seller or its authorized representative.
Buyer should notify TC Communications, Inc. promptly in writing of any claim based upon warranty, and
TC Communications, Inc., at its option, may first inspect such goods at the premises of the Buyer, or may
give written authorization to Buyer to return the goods to TC Communications, Inc., transportation charges
prepaid, for examination by TC Communications, Inc. Buyer shall bear the risk of loss until all goods
authorized to be returned are delivered to TC Communications, Inc. TC Communications, Inc. shall not be
liable for any inspection, packing or labor costs in connection with the return of goods.
In the event that TC Communications, Inc. breaches its obligation of warranty, the sole and exclusive
remedy of the Buyer is limited to replacement, repair or credit of the purchase price, at TC Communications,
Inc.’s option.
To return a product, you must first obtain a Return Material Authorization (RMA) number and RMA form
from the Customer Service Department. If the product’s warranty has expired, you will need to provide a
purchase order to authorize the repair. When returning a product for a suspected failure, please fill out RMA
form provided with a description of the problem(s) and any results of diagnostic tests that have been
conducted. The shipping expense to TC Communications should be prepaid. The product should be properly
packaged and insured. After the product is repaired, TC Communications will ship the product back to the
shipper at TC's cost to U.S. domestic destinations. (Foreign customers are responsible for all shipping costs,
duties and taxes [both ways]. We will reject any packages with airway bill indicating TC communications
is responsible for Duties and Taxes. To avoid Customs Duties and Taxes, please include proper documents
indicating the product(s) are returned for repair/retest).
- 22 -