Tayosan SRE 3001, SRE 4600, FR 32, FR 46 Instruction Manual

31
INSTRUCTION MANUAL
We thank you for purchasing our product. Please read this owners manual carefully before using the Heater. It is important that you handle and use the Unit according to the in­structions to ensure its long life and to avoid problems and accidents. Af­ter reading this guide, keep it for fu­ture reference.
INDEX
Pre-operation Instructions
Special precaution for safety.......................... 34
List of parts..................................................... 37
Preparation procedures.................................. 41
Unpacking.................................................. 41
Pre-ignition preparations and checkpoints . 41
Fuel to be used .......................................... 42
Fuel filling................................................... 44
Elevation adjustment.................................. 44
Operating Instructions
Ignition ........................................................... 45
Turning off...................................................... 46
Room temperature adjustment....................... 47
Time adjustment............................................. 48
Timer operation .............................................. 49
Child safety devices ....................................... 50
Maintenance and Others
Some cautions ............................................... 51
Maintenance .................................................. 52
Regular maintenance .................................... 54
Trouble-shooting ........................................... 55
Parts replacement/ Storage ........................... 58
Specifications................................................. 59
DANGER NO GASOLINE
LIQUID COMBUSTIBLE ONLY
32
SUMMARY OF THE SAFETY
PRECAUTIONS
IMPORTANT – DANGER – CAUTION
· Be sure to shut off operation before you sleep or go out (p. 34)
· Never use highly volatile fuels, such as gasoline, etc (p. 35)
· Shut off operation when refuelling (p. 35)
· Check to see there is no oil leakage (p. 35)
· Do not touch the warm air outlet during operation and immediately after the shutoff (p. 35)
· Do not use the unit at the following places (p. 36)
· Only top-quality liquid combustible for mobile heater, with the aromatics removed and totally free of impurities (max 1
% of aromatics and a flash-point above 61°) should be used (p. 42)
· Check the flame for ignition (p. 45)
· Preventing tampering (child safety lock) (p. 50)
· This heater has been designed with an Air-sensor device based on the direct measurement of the CO2 rate in the
room. Abnormal conditions of use of your heater (bad ventilation or too small a room) will automatically provoke the
shut-off of your heater and the Air-sensor light will come on. (p.51)
· Any tampering with or modification to the safety system is prohibited. Apart from invalidating the guarantee, this
would risk causing a failure of the system which is there for your safety (p. 51)
· This heater may not be used in rooms which are hermetically sealed, such as caravans, boats, passenger
compartments of vehicles etc. (p. 51)
· Use your heater in a room which is properly ventilated and free of inflammable vapours.
· Each room that the heater is used in must be adequately ventilated (the ventilator window must have min a surface
area of 50 cm2) (p. 51)
· Do not use your heater in too small a room . (p. 51)
· In case of damage to the power cord, it must only be replaced by a workshop recognised by the manufacturer (or
distributor). (p. 51)
· Always preserve a minimum clearance of 1 meter from other objects (p. 51)
· Do not use your heater in rooms situated under the floor level (p. 51)
· Whenever any of these safety systems is triggered, ventilate the room and check and eliminate the cause, and then
reignite. (p. 51)
· Never disconnect electric parts and never replace it with non non standard parts. (p. 51)
· Never disconnect neither the valve of the combustion control nor the combustion system (p. 51)
· In case of damage to the power cord, it must only be replaced by a workshop approved by the manufacturer (or
distributor) because some tools are necessary. (p. 51)
· Maintenance and regular maintenance (p. 52, 53 and 54)
33
SUMMARY OF THE OPERATION
IGNITION – SHUTTING OFF – FASTEN IGNITION
To ignite your heater, press the switch ON, the operation lamp lamp goes red. During ignition (+/- 2 minutes), a calculation will be done from 5 to 1 then the apparatus ignites. To shut off your heater, press the switch OFF, the operation lamp goes out, the blower fan will remain on for approximately 3 minutes to cool down your heater.
ADJUSTING THE TEMPERATURE
The preset temperature will be set at 20° C, to raise the temperature, press on + and to lower the temperature, press on -. You can set the temperature between 2°C and 30°C.
SETTING THE TEMPERATURE – AUTO OPERATION
To use the regulation of you heater, press AUTO switch, the AUTO lamp will come on. You just have to select the temperature with switch + and –. The heater will not shut off but will adjust his power in function with the room temperature.
SETTING THE TEMPERATURE – ECO/SAVE OPERATION
To use the thermostat of your heater, press SAVE switch, the SAVE lamp will come on. You just have to select the shutting off temperature with switch + and -. The heater will shut off 3 to 5°C above the setting temperature and will re-ignite when the setting temperature is reached.
SETTING THE TEMPERATURE – MIN OPERATION
To set the maximum power of your heater at 800 Watt (for SRE3001/FR32) and 1100 Watt (for SRE4600/ FR46), , press MIN switch, the MIN lamp will come on. You just have to select the temperature with switch + and –. The heater will work at his minimal power whatever the selected temperature or that of the room.
SET THE TIME
To set the time, press MODE switch, the clock set lamp is lit, the digitally displayed time is flashing at 00:00 at time of purchase. Press on switches + and – to set the time. The time setting will be completed after you have wait for few seconds.
TIMER OPERATION
You have first to set the time, then press switch ON (it is not necessary if the heater is working). Press switch TIMER, the heater will turn off or is not working. The display shows automatically “6:00”, you can set the start time with switches + and – as for the setting off time. Once the start time is selected, wait for a few seconds and the setting will be completed. The timer operation works only if the TIMER switch is green.
PREVENTING TAMPERING – CHILD SAFETY LOCK
To set the child safety lock, press CHILD SAFETY LOCK switch for more than 3 seconds, the child safety lock lamp will come on. To cancel, press CHILD SAFETY LOCK switch for more than 3 seconds again and the operation switch will turn off.
34
SPECIAL PRECAUTIONS FOR SAFETY
Special precautions are very important for you to use your fan heater.
DANGER Extremely dangerous to cause high risk of death or fatal casualty. WARNING Very dangerous to cause high risk of death or serious casualty. CAUTION May cause high risk of serious casualty or other physical damage.
DANGER!
NO GASOLINE
Never use highly volatile fuel, such as gasoline or inferior, deteriorated or impure kerosene. They cause a fire.
WARNING !
DO NOT use the heater for a long time without ventilating the room
properly.
Ventilate the room at least once or twice (1~2 minutes each time) every
hour.
Lack of oxygen causes imperfect combustion, which may cause highly
toxic carbon monoxide emissions in the room. It is very dangerous.
DO NOT use the heater in the basement with no ventilation device, or
rooms with no windows.
KEEP AWAY any kind of spray (cosmetic spray, insecticide spray, etc.,
that emits flammable gas such as thinners or benzene, etc.) from the blower unit.
Heated spray containers may be explosive, which may cause fire or me-
chanical breakdown.
KEEP AWAY all objects, such as cloth, paper, and other flammables,
from blower unit.
Obstructing objects may cause imperfect combustion or fire. Do not put on anything on the heater.
TURN OFF the heater and make sure flames are completely extin-
guished before going bed or leaving the room.
41
Ventilate room frequently
Keep away spray
Turn off
35
CHECK the fuel leak. Fasten the fuel tank cap securely. Hold the tank with top-side down to make sure it is not leaking. Leaking fuel can easily catch fire.
CLEAN air filter and intake once a week. Dirty air filter may cause imperfect combustion.
DO NOT use the heater in the case extraordi­nary flames, smells, sounds are noticed.
DO NOT disassemble the heater unit for repair­ment or conversion purpose. Stop using the heater if the system does not work properly or is damaged. Inappropriate repairment may cause further se­rious problems.
EMPTY fuel tank if the heater is unused for a long time, or when it is stored. It must be stored in an upright position, never in a tipped position or on its side. Failure to the instruction may cause fuel leak, and fire.
CAUTION
off
AVOID locations close to drapes of flammable ma­terial. DO NOT put laundries, sofas, too close to the blower unit. Flammable material or objects may cause fire.
DO NOT touch the blower grill while heater is on or immediately after use, to avoid fatal burning. Keep children away from them. Protecting Guard is available as an option (CFK-RG12).
AVOID direct exposure to the heated air for a long time of period. Long, direct exposure to the heated air may cause hypothermic burning or dehydration, especially on children and the aged.
ALWAYS TURN OFF the heater before filling with liquid combustible for mobile heater. AVOID fire or heated area when filling with liquid combustible for mobile heater.
58
52
45
Keep away 100 cm or more
Flammable material
Kep away children
Very hot part
Keep heater distant away
Heater Fuel tank
Turn off
Air Filter
Clean Air Filter
Fuel is leaking
36
SPECIAL PRECAUTIONS FOR SAFETY
CAUTION
HANDLE WITH CARE the power cord.
The power cord mustn't be given stressful force or nothing must be rested on it.
Also keep it away from heated blow wind.
Do not hold and pull the cord when unplugging.
ENSURE that the electrical socket is properly plugged.
Do not use any damaged socket or worn out cord. It may cause unexpected fire.
MAINTAIN the electrical socket clean.
Unplug the socket once a while and wipe out any dust, and check the damage.
Dust clog may cause electrical insulation defect and/or unexpected fire.
ENSURE when starting timer operation that no flammable material is around the heater. UNPLUG when the heater is not in use.
Also be sure to unplug when cleaning the unit or removing liquid combustible for mobile heater.
DO NOT USE THE HEATER;
if the floor surface is not flat and even; in the confined area such as under a mantelpiece; either above or under an unstable shelf; at places where the flammable gases may be generated or accumulate; at the isolated areas where no one is around nearby; at places where strong wind blows, draughts, corridor or near the entrance; at places where it is dusty or damp; in vehicles such as an automobile or a boat; in direct sunlight or at the place where the temperature tends to rise quickly; in places where gas or chemicals (e.g. freon gas, chloride compounds) are used,
such as beauty salons, barber shops, chemical plants, laundries, etc.;
at the high locations more than 400 meters above sea level. See adjustment.  Adjustment is necessary before using the heater. See `Elevation Adjustment'.
Failure to follow any one of above may cause unexpected accident.
KEEP all obstructions and flammable materials away from the heater unit. Keep the proper space between the heater unit and flammable walls, following the minimum distances shown on the illustration. Obstructions in front of the air blower may heat up the heater unit, which consequently may distort the plastic components in the system, or may cause the entire breakdown.
CAUTION!
Use the heater only on the heat-resistant floor.
Heat may cause colour change in a rug texture, or distortions or crackings on the floor surface.
Remove dust on the warm air blower (louvers).
Burnt dust may smell or may catch fire to cause unexpected accident.
Do not use any chemical containing silicone near the heater.
Hair conditioners, cosmetics, or polishing chemicals containing silicone may cause flaming disor­der. Do not dry hair with the heater because some shampoos also contain silicones.
100cm or more
15cm or more
15cm or more
100cm or more
100cm or more
52
44
37
LIST OF PARTS
External Components
*All cords are omitted to simplify the illustration.
FRONT:
Burner unit
I n s p e c t i o n window
BACK:
POWER: 230 a.c./ 50Hz household use ONLY
Fuel tank cover
Control panel Indicators
Warm air blower (Louver)
Base plate
Drain slot
Room thermo-sensor
Power cord
Power plug
Air intake filter (Air intake for combustion)
Warm air intake
Fuel gauge
*Do not lose it.
Gasket (black)
Fuel feeder cap
*Upright position
Tank handle
Fuel tank
54
Fuel receiver
Fuel strainer
Fuel filter
38
LIST OF PARTS
Control Panel/ Indicators for SRE 3001 / FR 32
*All indicators are illustrated "lit" status for descriptions.
INDIC ATOR SELECTOR KEY
Temperature, current ti me, ti mer­programmed time can be selected to in­dicate.
ODOR-FREE LAMP
The lamp is lit: Odor-free system is activating at the Ignition or at the extinction.
46
CHILD SAFETY KEY
On/off the safety function.
50
TEMPERATURE ADJUSTMENT KEY
Use when setting the desired temperature.
higher temperature lower temperature
TIME ADJUSTMENT KEY
Use when setting current time and/or the timer.
time ahead time back
47
48 49
POWER SELECTOR KEY
Use MIN/AUTO/SAVE for using pur­pose respectively.
47
"ON" KEY (OPERATION LAMP)
Use when starting the heater operation. The lamp is lit (red): under operation, pre-heating The lamp is flashing (red) + buzzer: flame is extin­guished and the display shows a code error or an alarm.
56 45
OFF BUTTON
Stops the operation.
38
TIMER CONTROL KEY (TIMER LAMP)
For time setting, TIMER, the switch TIMER is light green: timer operation is in stand-by status.
49
45
TIMING
TIMING KEY
Use when setting the desired combustion hour after the unit operates at programmed time.
At each pressing of timing key, indication changes as follows: [--h] Combustion goes as follows; [10h] 10 hours of combustion [ 9h] 9 hours of combustion
. .
. .
. .
[ 1h] 1 hour of combustion
49
39
LIST OF PARTS
Control Panel/ Indicators for SRE 4600 / FR 46
*All indicators are illustrated "lit" status for descriptions.
POWER SELECTOR KEY
Use MIN/AUTO/SAVE for using purpose respectively.
ODOR-FREE LAMP
The lamp is lit: Odor-free system is activating at the Ignition at the extinc­tion
CHILD SAFETY KEY
On/off the safety function.
TEMPERATURE ADJUSTMENT KEY
Use when setting the desired temperature. + higher temperature
- lower temperature
TIME ADJUSTMENT KEY
Use when setting current time and/or the timer. + time ahead
- time back
INDICATOR SELECTOR KEY
Temperature, current time, timer­programmed time can be selected to in­dicate.
"ON" KEY (OPERATION LAMP)
Use when starting the heater operation. The lamp is lit (red): under operation, pre-heating The lamp is flashing (red) + buzzer: flame is extin­guished and the display shows a code error or an alarm.
OFF BUTTON
Stops the operation.
SWITCH/TIMER LAMP
For time setting, timer on/off. The lamp is lit: timer operation is in stand-by status.
46
50
38
49
45
47
48 49
47
56 45
TIMING KEY
Use when setting the desired combustion hour after the unit operates at programmed time.
At each pressing of timing key, indication changes as follows: [--h] Combustion goes as follows; [10h] 10 hours of combustion [ 9h] 9 hours of combustion
. .
. .
. .
[ 1h] 1 hour of combustion
49
Loading...