Item No. _______________________________
RC25
Remote Condensing System
Features
Provides high capacity refrigeration for frozen beverage
dispensing. Either one or two dispensers may be connected
to each refrigeration system. Maximum total length of
refrigeration suction line is 150 feet (45.7 m).
Refrigeration System
One, approximately 16,000 btu/hr compressor. R404A.
(BTU s may vary based on compressor used.)
RC25
Rockton, Illinois 61072
800-255-0626
Phone 815-624-8333 Fax 815-624-8000
www.taylor-company.com
e-mail: info@taylor-company.com
International Office
Taylor Company S.r.l.
Roma, Italy
Tel: +39-06-420-12002 Fax: +39-06-420-12034
e-mail: romeoff@taylor-company.com
RC25Remote Condensing System
ø1.093 (28)
ELECTRICAL CONNECTION
NOTE: FIGURES IN PARENTHESES
INDICATE MILLIMETERS
WATER COOLED
VERSION
AIR IN
22-3/16
(564)
AIR OUT
REFRIGERATION CONNECTIONS
(AEROQUIP 5500 SERIES)
2-11/16 (69)
8-1/8 (207)
20-1/2
(521)
4-1/4
(108)
2-1/2 (64)
3-1/8 (80)
18-7/8
(480)
16-1/4
(413)
11-15/32
(292)
24-1/4
(616)
WATER OUT
3/8 FPT
WATER IN
3/8 FPT
RC25
Weights lbs. kgs.
Net 160 72.6
Crated 200 90.7
cu. ft. cu. m.
Volume 17.1 .48
Dimensions in. mm.
Width 24-27/32 631
Depth 24-1/4 616
Height 22-3/16 564
Floor Clearance 4-1/4 108
*Mounted on standard legs
Electrical Maximum Minimum Poles (P)
Fuse Size Circuit Ampacity Wires (W)
208-230/60/1 Air 30 18 2P 3W
208-230/60/1/Water 30 17 2P 3W
208-230/60/3 Air 20 13 3P 4W
208-230/60/3 Water 20 12 3P 4W
This unit may be manufactured in other electrical characteristics. Refer to the
local Taylor Distributor for availability.
(For exact electrical information, always refer to the data label of the unit.)
Bidding Specs
Electrical: Volt ___________________ Hz__________ ph _________
Neutral: Yes No Cooling: Air Water NA
Options:_________________________________________________
_________________________________________________________
Taylor Company,
A division of Carrier Commercial Refrigeration, Inc.
Rockton, Illinois 61072
815-624-8333 800-255-0626 Fax 815-624-8000
www.taylor-company.com
Specifications
Electrical
One dedicated connection required. Manufactured to be permanently
connected. See the Electrical chart for proper electrical
specifications.
Refrigeration Connections
Sealed bulkhead fittings, 5/8” OD on suction (low pressure) side and 3/8” OD
on discharge (high pressure) side. (Refrigeration lines are not provided.)
Air Cooled
Minimum Clearance: 3” (76 mm) on three sides, with air deflector installed
on condenser side. Minimum air clearances must be met to assure adequate
air flow for optimum performance.
Water Cooled
Water inlet and drain connections at rear, 3/8” FPT.
Options
Outdoor Use (Air Cooled Units Only)
Continuing research results in steady improvements; therefore, these
specifications are subject to change without notice.
053625-ADV
Printed in U.S.A.
6/09