25
I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 tr sv sl pt pl no nl it fr fi es en de da cz
Service, maintenance and care
The correct maintenance of the machine is a precondition for a flawless
operation and a long service life.
Service intervals
TASKI machines are built to the highest quality standards, and are tested for
safety in the factory and by authorised inspectors. Electrical and mechanical
parts are subject to wear or aging if used for long periods of time.
Service centre
Should you contact us due to a malfunction or for placing an order, please
always state the type, description and the serial number of your machine.
You can find this information on the name plate of your machine, and the
address of your nearest TASKI partner can be found on the last page of this
manual.
Transport
Ensure that the machine is securely fastened within the transportation vehicle.
Disposal
When it has reached the end of its operational life, the machine and its
accessories must be disposed of according to the national regulations.
Malfunctions
Technical data
Accessories
Caution:
Only TASKI branded spare parts must be used, otherwise
warranties and liabilities will be omitted!
Symbols:
◊ = after use, ◊◊ = every week, ◊◊◊ = every month
Activity ◊◊◊◊◊◊page
Check double-filter paper bag, replace if necessary
23
Clean the tool (roller brush, etc.)
24
Periodically check the length of the bristles
24
Replace the exhaust air filter for the electrical suction
brush
24
Replace the waste air filter for the suction unit
24
Replace the motor protection filter
24
Clean the machine with a damp cloth
24
• To maintain functional safety and operational readiness, a service must be
carried out after 300 working hours or at least once a year.
Under rough or extreme working conditions and/or insufficient maintenance,
shorter periods may be necessary.
Malfunction Possible causes Troubleshooting page
Machine does not
run
Not turned on • Turn on 22
Power supply cord not
properly plugged into
the mains socket
• Check
Power supply cord
defect
• Call for technical
assistance
Motor defect
• Call for technical
assistance
Main switch defect
• Call for technical
assistance
Electrical suction
brush does not
turn
Machine not in the
working position
• Place the machine in
the working position
22
Motor runs but not the
brush
• Drive defective
• Call for technical
assistance
Poor vacuum
performance
Motor protection filter
dirty
• Clean or replace motor
protection filter
24
Suction hose or
squeegee nozzle
blocked
• Remove the blockage
Double-filter paper
bag full.
• Replace
23
Cover of the suction
unit not correctly fitted
• Check
Suction hose not connected
• Check
Accessory not correctly fitted
• Check
Build-up of
odours
Damp double-filter
paper bag
• Store in a dry room
24
Accumulation of moisture
• Change double-filter
paper bag or drain tub
23
Name jet 38 jet 50
type TR5.38 TR5.50
Rated voltage 220-240 V
100-120 V
220-240 V
100-120 V
AC
AC
Frequency 50-60 50-60 Hz
Rated power 900 920 W
Machine weight 7.8 8.3 kg
Dimensions (L x W x H) 26x38x120 26x50x120 cm
A-weighted emission sound
pressure level EN 60704-1
<70 <70 dB(A)
Electrical protection class II II
Article jet 38/50
8502160 Double-filter paper bag (Pack of 10 units) X
8503640 Motor protection filter (Pack of 10 units) X
4121380 Exhaust air filter for electrical suction brush X
8505110 Exhaust air filter for suction unit X
8505180 Hepa filter (optional) X
Malfunction Possible causes Troubleshooting page