Tascam PA-30 User Manual

»
PA-30
Dual Power Amplifier
OWNER’S MANUAL
9A09572800
Introduction
The TASCAM PA-30 is a high-performance professional audio power amplifier for nearfield studio monitoring and low-level sound reinforcement. In stereo mode, the PA-30 delivers 30 watts per channel continuously into an 8 ohm load - with no more than
0.05% total harmonic distortion. For applications requiring higher output power, the unit may be operated in BTL (Balanced Transformerless) mode ­also known as 'bridged' operation - and will deliver a full 60 watts continuously into 8 ohms (see the 'BTL Operation' section of this manual on page 9). In either mode, it exhibits a flat frequency response characteristic from 20 Hz to 20 kllz (+0, –1dB), with very low residual hum and noise. For maximum flexibility, the PA-30 is equipped with both XLR-type balanced and RCA-type unbalanced input connectors. These accommodate nominal input signal operating levels of +4 dBm and –10 dBV, respectively essentially eliminating the necessity for external compensating pads or gain stages. A single, continuously variable INPUT LEVEL control attenuates input signals so the unit's sensitivity can be calibrated to the gain structure of the source equipment. The PA-30 is designed and built to provide years of trouble-free service with little or no maintenance. Its well built power transformer easily handles continuous full-power operation, and all power semiconductor circuits are mounted on a large convection-cooled heatsink.
Multiple resettable electronic protection circuits guard against destructive turn-on transients, output overload, DC offsets and output shorts. While the PA-30 is almost indestructible, it has been engineered to be easy to service. Like all TASCAM professional products, it is backed by a worldwide network of TASCAM dealers and TEAC authorized TASCAM service centers. Connection and operation of the PA-30 is simple and straightforward. This manual presents a detailed description of the unit's features, along with basic connection instructions and specifications. Please take a few moments to study it before connecting and operating your PA-30 Power Amplifier.
TABLE OF CONTENTS
Introduction................................................................. 2
Important Safety Instructions ..................................... 3
Summary of Operating Precautions............................ 4
Features....................................................................... 5
Connection & Installation........................................... 7
BTL Operation............................................................ 9
Specifications............................................................ 10
Ü
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert
ÿ Ÿ
This appliance has a serial number located on the rear panel. Please record the model number and serial number and retain them for your records.
Model number Serial number
2 TASCAM PA-30
the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the pres­ence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING: TO PREVENT FIRE OR SHOCK
HAZARD, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
IMPORTANT SAFETY INSTRUCTIONS
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
11) Only use attachments/accessories specified by the manufacturer.
12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
• Do not expose this apparatus to drips or splashes.
• Do not place any objects filled with liquids, such as vases, on the apparatus.
• Do not install this apparatus in a confined space such as a book case or similar unit.
• The apparatus draws nominal non-operating power from the AC outlet with its POWER switch in the off position.
13) Unplug this apparatus during lightning storms or when unused for long periods of time.
14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
TASCAM PA-30 3
Summary of Operating Precautions
• Do not use the PA-30 if the power cord appears frayed or broken.
• Do not spill liquids into or on the PA-30 chassis. If the chassis becomes wet, allow it to dry thoroughly before reconnecting the unit.
• Allow sufficient space at the top, and bottom of the PA-30 to permit a flow of cooling air. Keep the unit away from radiators or others that produce heat.
•Never connect the PA-30 outputs to a battery, power supply or other voltage source. Do not short the output hot terminals together.
• The minimum allowable load impedance on each PA-30 output is 8 ohms in stereo mode or BTL mode. Connecting loads of lower impedance will result in current limiting and/or activation of the protection circuits.
• Before operating the PA-30, be certain that the MODE switch is set in accordance with the desired operational mode and output connection configuration (see the 'BTL Operation' section of this manual, page 9).
•Any unauthorized internal modification to the PA-30 will invalidate the warranty, and may result in hazardous conditions. Refer all servicing to a TEAC authorized TASCAM service center.
• Connect the PA-30 only to properly wired AC outlets. Make certain that the voltage is correct for the version of the unit that you are using (110 to 120 volts at 60 Hz for domestic USA).
AC Power Connection
The PA-30 requires a reliable source of single-phase power at 110 to 120 volts AC, 60 Hz (domestic US version). It has a two-prong, ungrounded AC cord, and may be connected to either two-prong or three-prong outlets. If you have any doubt about the wiring of the outlet that you wish to use, it is wise to test it before making connections. Simple plug-in testers are available from a variety of electronics and hardware stores.
If an outlet appears to require repairs, consult a qualified electrician - and
don't use it. An improperly-
wired outlet may present a serious shock hazard. For reference, Figure 1 shows the characteristics of a properly wired US standard three-prong wall outlet.
120 VAC
Neutral
Earth
0 Volts
0 Volts
Figure 1. Standard wall Receptacle
Hot
0 ohms
120 VAC
Voltage Conversion
Be sure to unplug the power cord from the AC outlet before repositioning the voltage converter switch.
1) Locate the voltage selector on the rear panel.
2) Using a flat-bladed screwdriver, set to the appropriate 120 V or 230 V position according to your area.
120V
Figure 2. Voltage Selector