Tartarini V/31-2-E Series Pneumatic Switch Instruction Manual Manuals & Guides

Instruction Manual D104261X012
V/31-2-AP-E Series
September 2018
V/31-2-AP-E Series Switch for Flow Partition System
SUMMARY
Introduction ......................................................................... 1
Characteristics .................................................................... 2
Labelling ............................................................................. 2
Dimensions and Weight ...................................................... 2
Installation .......................................................................... 2
Startup ................................................................................ 5
SEP Statement ................................................................... 5
Field Inspection and Maintenance ......................................
Spare Parts......................................................................... 5
Troubleshooting .................................................................. 6
Parts List............................................................................. 6
Schematic Assemblies........................................................ 7
WARNING
!
Failure to follow these instructions or to properly install and maintain this equipment
could result in an explosion and/or re
causing property damage and personal injury or death.
Tartarini™ device must be installed, operated and maintained in accordance with federal, state and local codes, rules and regulations and Emerson Process Management Regulator Technologies, Inc. instructions.
5
Figure 1. Types V/31-2-AP-E and V/31-2-AP-EF
Switch for Flow Partition System
INTRODUCTION
Scope of the Manual
This manual provides installation, startup, maintenance,
troubleshooting, and spare parts for the switch for ow
Product Description
In monitor-regulator systems the pneumatic switch Type V/31-2-AP-E is installed on the motorization pressure
circuit, in order to obtain the capacity ow partition between
the pressure reducing lines.
If the device vents gas or a leak develops in the system, service to the unit may be required. Failure to correct trouble could result in a hazardous condition.
Call a gas service person to service the
unit. Only a qualied person must install or
service the device.
This product has been designed to be used with fuel gases of 1st and 2nd family according to EN 437, and with other non aggressive and non fuel gases. For any other gases, other
than natural gas, please contact your local Sales Ofce.
For special applications Types V/31-2 -AP-EF, V/31-2-AP-EM and V/31-2-AP-EMF versions are available on request (see Table 1).
V/31-2-AP-E Series
Type V/31-2-AP-E
Type V/31-2-AP-EM
CHARACTERISTICS
Table 1. Technical Features
TYPE
V/31-2-AP-E
V/31-2-AP-EM
V/31-2-AP-EF
V/31-2-AP-EMF
ALLOWABLE
PRESSURE
PS (bar)
100
SETPOINT
TYPE
Adjustable 0.5 - 2
Fixed 2
SET RANGE
Wd (bar)
1/4” NPT female threaded connections.
LABELLING
Notified
BOLOGNA ITALY
MATRICOLA SERIAL Nr. ANNO YEAR NORME ARMONIZ. HARMONIZED STD. CLASSE DI PERDITA LEAKAGECLASS CLASSE FUNZIONALE FUNCTIONAL CLASS FLUIDO GRUPPO FLUIDGROUP
TS
Note2
EN
1
Figure 2. Label for V/31-2-AP-E Series Pneumatic Switch
Note 1: See “Characteristics
Nota 2: Year of Manufacture
Nota 3: Class 1: -10°/60°C
Class 2: -20°/60°C
Note 4: See “Characteristics”
body
APPARECCHIO TIPO /DEVICE TYPE
xxxx
DN1
DN2
Wa
Wao
Cg
pmax
PS
°C
body
Wau
bar
bar
PS covers
Note 1
pao
bar PT= xPSbar
-
BODY AND
COVERS
MATERIAL
Steel
1.5Note 4Note 3
CAUTION
All interventions on the equipment should only be performed by qualied and trained personnel.
For further information, please contact our
local Sales Ofce or our Authorized Dealers.
INSTALLATION
WARNING
!
Personal injury or equipment damage, due to bursting of pressure-containing parts may result if this device is overpressured or is installed where service conditions could
bar
bar
bar
bar
exceed the limits given in the Characteristics section and on the appropriate nameplate or where conditions exceed any rating of the adjacent piping or piping connections.
To avoid such injury or damage, provide pressure-relieving or pressure-limiting devices to prevent service conditions from exceeding those limits.
Also, be sure the installation is in compliance with all applicable codes and regulations.
Additionally, physical damage to the device can cause personal injury and property damage due to bursting of pressure-containing parts.
DIMENSIONS AND WEIGHT
Figure 3. Dimensions (mm) V/31-2-AP-E Series Pneumatic Switch
Type V/31-2-AP-EF
Type V/31-2-AP-EMF
202
Ø 75 Ø 75
TYPES V/31-2-AP-E and V/31-2-AP-EM WEIGHT: 3.5 kg
TYPES V/31-2-AP-EF and V/31-2-AP-EMF WEIGHT: 2.9 kg
To avoid such injury and damage, install the device in a safe location.
CAUTION
The device must be rated for the maximum
allowable operating pressure of the ow
partition system.
a. Check that data on the pilot’s plate are compatible with
actual working conditions.
b. Install in accordance with regulator instruction manual.
107
2
INSTALLATION (continued)
ANY OTHER LINES
TYPE PS/80
TYPE PS/79
V/31-2-AP-E Series
D
TYPE
A
V/31-2-AP-EF
B
C
2
M
2
V
R
1
S
MONITOR
TYPE PS/80
V V
R
2
M
2
R
S
REGULATOR
TYPE PS/79
R
V
1
4 X DN
6 X DN
S
MONITOR
1
M
LEGEND:
VENT DOWNSTREAM OR TO A SAFE AREA
1
TO THE HEATING
2
NOTE: RECOMMENDED PIPING IS STAINLESS STEEL WITH 10 mm DIAMETER.
M
Figure 4. Type V/31-2-AP-EF Switch for Flow Partition System Connection/Installation Schematic
S
REGULATOR
1
4 X DN
6 X DN
3
Loading...