Tappan TGF657BFW6, TGF657BFW7, TGF657BFW8, TGF657BFU4, TGF657BFU2 Installation Guide

...
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUAUHED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
mfthe information in this manuam is not fommowed e×actmy,a fire or e×pmosion may resumt
causing prope_y damage, personaE iniury or death.
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
Do not t_ to might any appmiance.
® Do not touch any eme_rkamswitch; do not use any phone in your building.
* mmmediatemycam[your gas supplier from a neighbor's phone. Fommowthe gas suppmier's instru_ions. ® If you cannot reach your gas suppmier, camEthe fire depa_ment.
i mnstammationand service must be performed by a quamified instammer,service agen_ or the gas suppmier.
Dimensions and Cmearance
Provide adequate clearan(e between range
and a@acent combustible surfaces.
TYPICAL CONTROL PANEL X, HEIGHT
HI Profile Control Panc-,I 45 5/8" I'nin, LO Profile Control Panel 40 7/8" Min
25 1/8"
35
_36 ....
Minimum
wall on either
side of range 18" cabinets on either
above 36" height ............................................._,_;_ l sid6, of range
36"
to
30" Minimum
I_(x:: tx ix: tx tx tx t
A
Minimum to
V
O" Clearance at rear of
range below cooktop.
Figure I
NOTE: Wiring diagrams for these appliances are enclosed in this booklet. Printed in United States
P/N 318201750 (0410) Rev C
English - pages 1-9
Espa_ol - p_ginas 10-19
Wiring Diagrams - pages 20-24
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing the range.
2. Remove all packing material before connecting the electrical supply to the appliance.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
Important Note to the Consumer Keep these instructions with your Useand Care Guide for
future reference.
IMPORTANT SAFETY
NS
Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code ANSI Z223. l--latest edition.
This range has been design certified by American Gas Association (A.G.A.). As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find them in the Useand Care Guide,, read it carefully.
Be sure your range is installed and grounded
properly by a qualified installer or service technician.
This range must be electrically grounded in
accordance with local codes, or in their absence, with the National Electrical Code ANSI/NFPA No.
70--latest edition. Tile installation of appliances designed for
manufactures (mobile) home installation must conform with Manufactured Home Construction and Safety Standard, title 24CFR, part 3280 [Formerly tile Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part 280)] or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Set ups), ANS! Z225.1 latest edition,
or local codes.
, All ranges
can tip
Injury to persons
could result.
Install anti- tip device
packed with
range,
]b reduce the risk of tipping of the range, the range
must be secured by properly installed anti-tip bracket (s) provided with tile range. ]b check if the bracket(s) is
installed properly, grasp tile top rear edge ol the range and carefully tilt it forward to make sure tile range is anchored
Before installing the range in area covered with linoleum or any other synthetic floor covering, make sure the floor covering can withstand heat at least 90°F above room temperature without shrinking, warping or discoloring. Do not instatt the range over carpeting unless you place an insulating pad or sheet of 1/4"thick ptywood between the range and carpeting.
Make sure the wall coverings around the range can withstand the heat generated by the range.
Do not obstruct tile flow of combustion air at the oven vent nor around the base or beneath the lower front
panel of the range. Avoid touching the vent openings or nearby surfaces as they may become hot. This range requires fresh air for proper burner combustion.
Do not store items of interest to children in the cabinets above the range, Children could be
seriously burned climbing on the range to reach items.
To eJiminate the need to reach over the surface burners, cabinet storage space above the burners
should be avoided. Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil, Excessive flame is hazardous.
Do not use the oven as a storage space. This creates a potentially hazardous situation.
Never use your range for warming or heating the room. Prolonged use of tile range without adequate
ventilation can be hazardous.
Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance. Explosions or fires could result.
Remove broiler pan and other utensils and wipe up excess spillage before self-cleaning the oven (if equipped).
Do not make any attempt to operate the electric ignition oven during an electrical power failure. Resumption of electric power when OVEN TEMP and OVEN SETcontrols are in any position other than OFF will result in automatic ignition of the oven or broiler
burner.
tn case of a power outage, you can light the surface burners on your range with a match. Hold a lighted match to the burner, then slowly turn the knob to tile LITE position. Use extreme caution when tighting burners this way.
Surface burner in use when electrical power failure occurs will continue to operate normally.
The oven burner and broil burner on your range are lighted by electrical ignition. The oven and broiler cannot be operated in the event of a power failure.
1. Before lnstamming the Range
Remove shipping materia] Remove all tape, shipping and packaging materials and
the oven rack packaging. Lift up cooktop and remove the two shipping screws from the cooktop burners (see
figure 2). Screws
i
B. Install Y2" flare union adaptor supplied with the
connector, to the Y2" NPT internal thread on pressure
regulator.
Gas Connection for Etectdc Ignition Models
FlareUnion Adaptor
Flexible Appliance Pressure
Connector Regulator
Figure 3
Figure 2
2. Provide an Adequate Gas Supply
This range is designed to operate on natural gas at 4" of manifold pressure or on LPgas at !0" of manifold
pressure. It is shipped from the factory set for natural gas. If it is to be used with LPgas, adjustments must be made.
A convertible pressure regulator is connected in series with tile manifold of the range and must remain in series
with the supply line regardless of whether natural or LP gas is being used.
For proper operation, the maximum inlet pressure to the regulator must be no more than 14" of water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at least 1" water column pressure greater than the regulator manifold outlet setting. If tile regulator is set for 4" of manifold pressure, the inlet pressure must be at least5". If the regulator isset for l0", the inlet pressure
must be at least 11 ".
C. Because solid pipe restricts moving the range we
recommended use of A.G.A. design certified flexible metal appliance connector. Connect flexible
appliance to flare union.
D. Move range into approximate position and connect
flexible appliance connector to gas supply line with
proper flare union adaptor. The adaptor supplied with
the flexible connector must be used.
E. Check for leaks. Turn the gas supply on tile range
and use a liquid leak detector at all joints and connections to check for leaks in the system.
3-Wire Polarized
120V.Outlet
32 7Is" -+1/4'
Pipe
The gas supply line into the range should be _/2"or 3A" I.D. flexible metal appliance connector five feet in
length.
3. Seal the Openings
Seal any openings in the wall behind the range and in the floor under the range when hookups are completed.
4. Connect the Range to Gas
Refer to figure 4 to 7 for recommended connections.
A. tnstall a manual shut-off valve in the gas line in an
easily accessible location outside of the range. Be sure you know how and where to shut-off the gas supply to the range.
Recommended locations for installing the electrical outlet and pipe opening may be adjusted to meet specific requirements.
Figure 4
Donotuseaflametocheckforleaks
fromgasconnections.Checkingforleakswithaflame mayresultinafireorexplosion.
17/16" 3A"
2 5/8 "
/ Wall
Disconnectthisrangeandits individualshutoff valvefromthegassupplypipingsystemduringany pressuretestingofthatsystemattestpressuresgreater than14"ofwatercolumnpressure(approx.Y2" psig).
Isolate the range from the gas supply piping system by (:losing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or lessthan 14" of water column (approx. Y2" psig).
Back of Range
1/2"
Close Nipple
Flexible Connector
Recommended Shut-Off
11y2"" _,s",_i,
!! i
i!ii i
Counter
Pressure Regulator
TOPVIEW FRONTVIEW
5. LP/Propane Gas Conversion
A. Pressure Regulator Conversion
Top
Solid Pipe Hookup Detail
Figure 7
/
O
Floor
NAT.
jocation
Flexible Connector Hookup
Figure 5
Union
Solid Pipe Hookup
Figure 6
Back of Range
:rrr rrn
i Y2" Nipple 1
P:
L.R _ _ Cap Screw
Figure 8
Do Not Remove the Pressure Regulator Remove cap-screw and snap out the nylon gas indicator by pushing it sideways. Turn the nylon gas indicator for type gas (Natural or LP)and snap it back in the cap-screw. Put cap-screw back on gas regulator.
B. Surface Burner Valves Conversion
/
/
Top Burngr Adj
Figure 9
1. Lift cooktop to gain access to the surface burner spuds.
2. With Y2" wrench, turn spud down or clockwise until snug (approximately 2 Y2turns). This restricts the
flow of gas through spud to that allowed only by the
hollow LP metering pin. Do notovertightem
Air Shutter
Nat.
C. Readjust the "LOW" Setting Surface
Burner Valve
1. Turn control to LITEuntil burner ignites.
2. Quickly turn knob down to LOWESTSETTING.
3. If burner goes out, readjust valve as described in "Adjust the LOW Setting Surface Burner Valve" from
Page 7.
D. Air Adjustment Shutter
Apply gas to the burner and adjust air shutter on burner venturi tube to proper flame. ForLPgas, the air shutter is generally left completely open.
Air adjustment shutter_
Natural Gas
Pin -X
Increase Gas Increase Flame Size-_.,
(Pre-Set at Factory for Natural Gas)
A
/,-- L.R Gas
Decrease Gas Decrease Flame Size
Figure 10
3. Lower main top and apply gas to check for proper flame size. Flame should be steady with
approximately Y2" blue inner cones and no yellow or orange tips.
Inner Cone Flame Length
Figure 12
The air adjustment for each burner is located at the open end of the venturi tube and sits on the hood of
the valve. The shutter is held in place by friction fit.
If air shutter needs adjusting, rotate the shutter to allow more or less air into the burner tubes as needed.
Figure 11
Proper Air Adjustment If air shutter is adjusted so that too much air flows into the burner, the flame will appear unsteady, possibly not burning all the way around and will be noisy (like a blow torch).
Oven Burner Spud
Figure 13
E. Convert Oven Burner Orifice
1. Remove storage drawer if equipped or lower panel to gain access to oven burner spuds.
2. Remove oven bottom and oven burner baffle located on top of burner. To remove oven bottom,
pull up at rear, disengaged front of bottom from
oven front frame, and pull the oven bottom straight out of the oven. Remove burner baffle so that the
burner flame can be observed.
3. Using Y2" wrench, turn down the adjustable spud
which injects gas into the oven burner, until snug against the LP metering pin. This will be approximately 2 Y2turns. Do Not Overtighten.
4. Push the BAKE TEMP button, then SETthe
temperature to 300°F. Wait until burner starts to cycle. To determine if the oven burner flame is
proper, observe the flame. It should be steady with
approximately 1" blue cones and no /allow or orange flame tips.
Air Shutter
Figure 14
5. If adjustment to the air shutter is necessary, locate
oven burner air shutter, loosen shutter set screw and adjust to obtain optimum flame (figure 14). This
will normally be completely open for LP gas. Tighten shutter set screw.
1. Open oven door.
2. Locate broiler burner spud and turn down approximately 2 Y2turns so that spud is snug against
LPmetering pin. Do NotOvertighten.
3. To determine if burner flame is proper, push the
BROILbutton, then turn the SETknob to the LO
setting, and observe broiler flame. It should be steady and sharp with approximately 1" blue cones and no yellow or orange flame tips.
4. If adjustment to the air shutter is necessary, locate oven burner air shutter, loosen shutter set screw and
adjust to obtain optimum flame (figure 14). This will normally be completely open for LPgas. Tighten shutter set screw.
5. Connect Electridty to Gas Range
Electrical Requirements
120 volt, 60 Hertz, individual, properly grounded and polarized branch circuit protected by a 15 amp. circuit breaker or time delay fuse.
Extension Cord Cautions: Because of potential safety hazards under certain
conditions we strongly recommend against tile use of any extension(ord. However, if you still select to use an extension cord, it is absolutely necessary that it be a UL listed 3-Wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than tile branch circuit rating. Such extension cords are obtainable through your local service organization.
Grounding Instructions
F. Convert Waist High Broiler Burner Orifice
Flame (Self-Clean Models Only)
Figure 15
IMPORTANT Please read carefully.
For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3- prong (grounding) plug which mates with a standard 3- prong grounding wall receptacle (see Figure 8) to minimize the possibility of electric shock hazard from tile appliance.
The wall receptacle and circuit should be checked by a qualified electrician to make sure the receptacle is properly grounded.
Do not, under any
circumstances, cut,
remove, or bypass
the grounding
prong,
Grounding typewall receptacle
Figure 16
Where a standard 2-prong wall receptacle is installed, it is the personal responsibility and obligation of the consumer to have it replaced by a properly grounded 3- prong wall receptacle.
Do not, under any circumstances, cut or remove the third (ground} prong from the power cord.
Disconnect electrical supply cord from
wall receptacle before servicing range.
Power supply cord with
3-prong grounding plug
7. Check Operation
Refer to the Use and Care Guide packaged with the range for operating instructions and for care and cleaning of your range.
B) Oven igniter System
Self-Clean Models: Remove all materials and literature from oven and:
1. Push the BAKE TEMP button and set the oven temperature to 300°F. Within 60 seconds tile
bake (lower) burner will ignite. Check for proper flame; push the CANCEL button.
2. Push the broil button and set the oven temperature to 300°F. Within 60 seconds the broil (upper) burner will ignite. Check for proper flame. Allow burners to cycle at least one time; push tile
CANCEL button.
Non Self-Clean Models: Remove all materials and literature from oven and:
1. Turn oven temperature knob to BAKE(300°F). Within 60 seconds the lower burner should ignite. Check for proper flame. Turn knob to off.
2. Turn oven temperature knob to BROIL. Within 60 seconds the lower burner should ignite. Check for proper flame. Turn knob to off.
Do not touch tile burners. They may be hot enough to cause burns.
1. Check the igniters Operation of electric igniters should be checked after range and supply line connectors have been carefull_ checked for leaks and range has been connected to electric power.
Note: If range isto be operated on LP. gas, conversion of regulator and adjustment of burner spuds is necessary before ignition check; refer to 777.
A} Surface Burner Igniters
To check for proper lighting, push in and turn a surface burner knob to the LITEposition. The surface
burner should light when gas is available to top burner. Each burner should light within 4 seconds in normal operation after air has been purged from
supply lines. Once the burner lights, knob should be
rotated out of theLITE position. Try each valve
separately until all burners have been checked out.
Figure 17
A.
Turn control to LITEuntil burner ignites.
B.
Quickly turn knob down to LOWEST POSITION.
C.
If burner goes out, readjust valve asfollows: Remove the surface burner control knob, insert a
thin-bladed screw driver into tile hollow valve stem and engage tile slotted s(rew inside.
Flame size can be increased or de(reased with the turn of the screw. Adjust flame until you
can quickly turn knob from LITEto LOWEST POSITIONwithout extinguishing the flame.
Flame should be as small as possible without going out.
8. Make Sure Range Is Level
Level the range by placing a level horizontally on an oven rack. Check diagonally from front to back, then level the range by either adjusting the leveling legs or by placing shims under the corners of the range as needed.
9. When installation is complete, connect the power cord and set the time of day on the
electronic oven control as explained in the Owner's Guide.
10. Verify the operation of the electronic
control functions as per instructions given in the Owner's Guide.
11. Make sure the air flow from the oven
vent and the air flow to the bottom front of range is unobstructed,
When ABB Hookups are Complete Make sure all controls are left in the OFFposition.
NOTE: Refer to Owner's Guide for complete instructions for ordering parts or making inquiries about this range.
NOTE: Refer to Owner's Guide for operating instructions and cleaning instructions.
important: See next page for Anti-tip Bracket installation instructions.
Model and Serial Number Location
Tile model and serial plate is located in the left hand side, underneath the surface cooktop.
When ordering parts for or making inquires about your range, always be sure to include tile model and serial numbers and a lot number or letter from the serial plate of your range.
Your serial plate also tells you the rating of the burners and type of fuel and the pressure the range was adjusted for when it left tile factory.
Before You Call for Service
Read the Avoid Service Checklist and operating instructions in your Use and Care Guide.
Check to make sure the house fuse or circuit breaker for your cooktop are not blown or open.
Loading...