Tap Magic 17040E User Manual

Safety Data Sheet
according to 29CFR1910/1200 and GHS Rev. 3
Effective date : 03.18.20 15
Page 1
of 7
Tap
Magic EP-Xtra
Created by Global Safety Management, 1-813-435-5161 -
www.GSMSDS.com
This SDS applies to part numbers: 10004E, 10016E, 10128E, 10640E, 13840E, 17040E
Ingredients:
SECTION 1: Identification of the substance/mixture and of the supplier
SECTION 2: Hazards identification
SECTION 3: Composition/information on ingredients
Product name Manufacturer/Supplier Trade name: Manufacturer/Supplier Article number: 10004E, 10016E, 10128E, 10640E, 13840E, 17040E
Recommended uses of the product and restrictions on use: Machining, Cutting, Tapping, and Metal
Processing.
:
Tap Magic EP-Xtra
Special Notes on Product Uses
and/or corrosion.
Manufacturer Details:
The StecoCorporation 2330 Cantrell Road Little Rock, AR 72202 USA 501-375-5644 Website: www.tapmagic.com Email: steco@tapmagic.com
Emergency telephone number:
ChemTel Inc.:
(800)255-3924, +1(813)248-0585
: After use of this product, clean and lubricate metal surfaces to avoid staining
Classification of the substance or mixture:
Signal word
Hazard statements:
: None
None
Precautionary statements:
None
Other Non-GHS Classification:
WHMIS
NFPA/HMIS
None
NFPA SCALE (0-4)
HMIS RATINGS (0-4)
Safety Data Sheet
according to 29CFR1910/1200 and GHS Rev. 3
Effective date : 03.18.20 15
Page 2
of 7
Created by Global Safety Management, 1-813-435-5161 -
www.GSMSDS.com
This SDS applies to part numbers: 10004E, 10016E, 10128E, 10640E, 13840E, 17040E
Tap Magic EP-Xtra
CAS 64742-53-6
Hydrotreated oil
1-60%
CAS 63449-39-8
Paraffin wax compound
1-25 %
Percentages are by weight
SECTION 4: First aid measures
SECTION 5: Firefighting measures
SECTION 6:
Accidental
release measures
Description of first aid measures
After inhalation:
Move exposed individual to fresh air. Loosen clothing as necessary and position individual in a comfortable position. Seek medical advice if discomfort or irritation persists. If breathing difficult, give oxygen.
After skin contact:
Wash affected area with soap and water. Rinse/flush exposed skin gently using water for 15 -20 minutes. Seek medical advice if discomfort or irritation persists.
After eye contact:
Protect unexposed eye. Rinse/flush exposed eye(s) gently using water for 15-20 minutes. Remove contact lens(es) if able to do so during rinsing. Seek medical attention if irritation persists or if concerned.
After swallowing:
IF SWALLOWED: Immediately call a POISON CENTER or doctor. Do NOT induce vomiting.
Most important symptoms and effects, both acute and delayed:
Irritation. Nausea.
Indication of any immediate medical attention and special treatment needed:
If seeking medical attention provide SDS document to physician. Physician should treat symptomatically.
Extinguishing media
Suitable extinguishing agents:
Use water, dry chemical, chemical foam, carbon dioxide, or alcohol-resistant foam.
Unsuitable extinguishing agents:
None identified.
Special hazards arising from the substance or mixture:
Thermal decomposition can lead to release of irritating gases and vapors.
Advice for firefighters:
Protective equipment:
Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Additional information (precautions):
Avoid inhaling gases, fumes, dust, mist, vapor, and aerosols. Avoid contact with skin, eyes, and clothing.
Personal precautions, protective equipment and emergency procedures:
Ensure adequate ventilation. Ensure that air-handling systems are operational.
Environmental precautions:
Should not be released into environment.
Methods and material for containment and cleaning up:
Wear protective eyeware, gloves, and clothing. Refer to Section 8. Keep in suitable closed containers for disposal. Refer to Section 13. Always obey local regulations.
Safety Data Sheet
according to 29CFR1910/1200 and GHS Rev. 3
Effective date : 03.18.20 15
Page 3
of 7
Tap
Magic EP-Xtra
Created by Global Safety Management, 1-813-435-5161 -
www.GSMSDS.com
This SDS applies to part numbers: 10004E, 10016E, 10128E, 10640E, 13840E, 17040E
Appearance (physical state,
Liquid, Amber
Explosion limit lower: Explosion
Not determined
Odor:
Mild
Vapor pressure at 20°C:
Not determined
Odor threshold:
Not determined
Vapor density:
Not determined
pH-value:
Neutral (non-aqueous)
R.elative density:
Not determined
Melting/Freezing point:
Not determined
Solubilities:
Insoluble in water
Boiling point/Boiling range:
Not determined
Partition coefficient (n- octanol/water):
Not determined
Flash point (closedcup):
>150 C
Auto/Self
- ignition
Not determined
SECTION 8: Exposure controls/personal protection
SECTION 9: Physica l and
chemical
properties
Reference to other sections:
Precautions for safe handling:
None
Avoid contact with skin, eyes, and clothing. Follow proper disposal methods. Refer to Section 13. Do not eat, drink, smoke, or use personal products when handling chemical substances. Use only with adequate ventilation.
Conditions for safe storage, including any incompatibilities:
Keep container tightly sealed. Store away from incompatible materials.
Control Parameters: Appropriate Engineering controls:
No applicable occupational exposure limits.
Emergency eye wash fountains and safety showers should be available in
the immediate vicinity of use or handling. Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapor and mists below the applicable workplace exposure limits (Occupational
Respiratory protection:
Exposure Limits-OELs) indicated above. Where risk assessment shows air-purifying respirators are appropriate
use a full-face respirator with multipurpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN(EU).
Protection of skin:
Select glove material impermeable and resistant to the substance. Select glove material based on rates of diffusion and degradation. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Use proper glove removal technique without touching outer surface. Avoid skin contact with used gloves. Contact glove manufacturer for specific information. Wear appropriate clothing to
Eye protection: General hygienic measures:
prevent any possibility of skin contact. Safety glasses or goggles are appropriate eye protection. Avoid contact with skin, eyes, and clothing.
Loading...