11. The lamp is held in at each end by spring clips that hold the lamps ceramic caps in the lamp holders. Pull the clips back (Fig. 11a)
far enough to allow the ceramic caps to be lifted up (Fig. 11b) at both ends and remove the lamp from the heater.
Reference Manual
Algarve
UK & EUROPEAN MODELS:
Fig. 11b Fig. 11a
12. The heater should now be broken down as shown in Fig. 12. Note: One of the lamp wires is longer than the other. Ensure your
new lamp wires are the same length and it’s fitted the same way around as the original.
ALG 510 UK & ALG 510 EU (230 V - 1000 W)
ALG 513 UK & ALG 513 EU (230 V - 1300 W)
ALG 515 UK & ALG 515 EU (230 V - 1500 W)
Fig. 12
13. Refit the new lamp in reverse order ensuring that no wires get trapped and all screws are fully tightened.
F o l l ow i n g i n f o r m a t i o n i s o n l y f o r E U - m e m b e r s ta t e s :
The use of this symbol indicates that this product may not be treated as household waste. By ensuring this product
is disposed of correctly, you will help prevent potential negative consequences for the environment and human
health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed
information about recycling of this product, please contact your local council, your household waste disposal service
or the shop where you purchased the product.
©Tansun Limited 2015 Part No. 043141 Issue. A
Spectrum House, Unit 1, Ridgacre Road, West Bromwich,
West Midlands, B71 1BW, England.
Tel: +44 (0)121 580 6200 - Fax: +44 (0)121 580 6222
Email: sales@tansun.com - Website: www.tansun.com
Ca ut io n
or instruction concerning use of the appliance in a safe way and
derstand the hazards involved. Children shall not play with the
tended normal operating position and they have been given
When using Tansun electrical heaters, basic precautions should always be
followed to reduce the risk of fire, electric shock, and injury to persons,
including the following:
7. Remove the connector block retaining bridge by removing the screw and lifting out. This will allow the connector block to be lifted
out of its locating lugs to allow for better access when connecting the new lamp terminals. For now though leave it in its locating lugs
and unscrew the connector block screws as highlighted (Fig. 7a) and remove the white lamp wires so they are free (Fig. 7b).
Read all instructions before using this heater.
• Before using this appliance:
- Check that the voltage indicated on the type plate corresponds to the
mains supply voltage.
- Ensure that the heater has been securely fastened in it
position.
• Do not locate the heater immediately below a socket outlet.
• This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
un
appliance. Cleaning and user maintenance shall not be made by
children without supervision.
• Children of less than 3 years should be kept away unless continually
RETAINING BRIDGE
Fig. 7a
8. From inside the heater body, gently pull the lamp wires through the sealing gasket so the lamp wires exit the terminal box and are
free as shown below in Fig. 8.
LONGER WIRE
Fig. 8
9. Turn the heater body over and slide the side reflectors out at each end and then slide the guard out of the heater by pushing it
towards one of the ends where the end caps are removed (Fig. 8). Note: the reflectors sit on top of the guard legs for refitting.
Fig. 7b
supervised.
• Children aged from 3 years and less than 8 years shall only switch on/
off the appliance provided that it has been placed or installed in its
in
supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and clean the appliance or
perform user maintenance.
• CAUTION—Some parts of the product can become very hot and
cause burns. Particular attention has been given where children
and vulnerable people are present.
• Remove the plug from the mains socket (or disconnect pole switch)
during installation, cleaning and/or replacing the element and always
ensure that the element is cool.
Fig. 9
10. Pull the lamp wires through the two access holes so it is ready to be unclipped and removed from the heater (Fig. 10).
LONGER WIRE
2
Fig. 10
7