The lightning ash with arrowhead symbol within anequilateral triangle, is intended to alert the user to thepresence of uninsulated "dangerous voltage " within theproduct's enclosure that may be of sucient magnitudeto constitute a risk of electric shock to persons.
Important Safety Instructions
The lightning ash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage " within the
product's enclosure that may be of sucient magnitude
to constitute a risk of electric shock to persons.
1. Read these instructions.
2. Keep these instructions
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance
with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers that
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the
other. A grounding type plug had two blades and a third grounding
prong. The wide blade or the third prong are provided for your
safety. If the provided plug does not t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
11. Only use attachments / accessories specied by the
manufacturer.
12. Use only with the cart stand, tripod, bracket or mount table
specied by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart /
apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightening storms or when unused
for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is
required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate
normally, or has been dropped.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
SAFETY WARNING
Permanent disconnection from the mains supply is achieved
by removing the power cord from the mains supply outlet.
UNDER NO CIRCUMSTANCES SHOULD YOU BREAK THE
POWER USING THE powerCON CONNECTOR.
SAFETY WARNING
Do not remove any covers, loosen any xings or allow items to
enter any aperture
SAFETY WARNING
Objects lled with liquids should not be placed on this
apparatus.
SAFETY WARNING
The rear heatsink on this product gets hot. Avoid direct skin
contact during operation and for at least 5 minutes after power
has been isolated.
AVERTISSEMENT DE SECURITE
Pour déconnecter l’appareil de l’alimentation principale de
façon permanente, débranchez le connecteur du câble fourni à
l’arrière de l’appareil.
AVERTISSEMENT DE SECURITE
Ne retirez pas les couvercles, ne desserrez pas les xations et ne
laissez aucune pièce s’introduire dans les ouvertures.
AVERTISSEMENT DE SECURITE
Ne placez pas d’objets contenant du liquide à proximité de
l’appareil.
AVERTISSEMENT DE SECURITE
Le radiateur arrière de cet appareil devient chaud. Evitez tout
contact direct avec la peau pendant le fonctionnement et au
moins 5 minutes après la mise hors tension de l’appareil.
VXP Series Operation Manual rev 3.0.0
2
Installation Instructions
1. THIS PRODUCT MUST BE EARTHED. Use only a exible
cable or cord provided with a green or green and yellow core
which must be connected to the protective earthing terminal
of the detachable Neutrik ‘powerCON’ type NEC3FCA
connector (Tannoy part number 3461 0919) as supplied with
the equipment. The other end of the green or green and yellow
conductor must be connected to the earthing pin of a suitable
mains plug or the earthing terminal of the installation. The cord
must be of maximum length 7.5 meters, rated SJ, SJT, or SJE,
10A minimum and be marked VW-1.
2. The electrical power connection to this product is only to
be made via a detachable Neutrik ‘powerCON’ type NEC3FCA
connector (Tannoy part number 3461 0919) as supplied with
the equipment. Wiring to this connector must be made
by suitably qualied personnel and must comply with all local
requirements.
3. Do not install this equipment in an enclosed space. Do not limit
free ventilation and movement of air around the back panel.
Ensure that there is at least 100 mm (4”) of space around all
sides of the product for ventilation. Only use attachments and
accessories approved or specied by Tannoy.
FOR CUSTOMERS IN EUROPE
This product complies with both the LVD (electrical safety)
73/23/EEC and EMC (electromagnetic compatibility) 89/336/
EEC directives issues by the commission of the European
community. Compliance with these directives implies conformity
with the following European standards:
EN60065 Product safety
EN55103-1 EMC emissions
EN55103-2 EMC immunity
This product is intended for the following electromagnetic
environments: E2; E3 & E4. Environment E1 (domestic) is
specically excluded.
FOR CUSTOMERS IN THE USA & CANADA
This product has been tested for electrical safety and
complies with:
UL60065 7th edition
CA/CSA C22.2 No.60065-03 EMC
This equipment has been designed to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment.
Industry Canada Class A emission compliance statement:
This Class B digital apparatus complies with Canadian ICES-003.
Avis de conformite’ a’ la re’glementation d’Industrie Canada, cet
appareil nume’rique de classe A est conforme a’ la norme ICES-
003.
VXP Series Operation Manual rev 3.0.0
3
Table of Contents
Table of Contents
1. Introduction 5
2. Unpacking and Visual Checks 6
2.1. Preliminary Recommendation 6
3. Rear Interface Panel 7
4. Operation 8
4.1. Preliminary Recommendation 9
4.2. Auto and Manual Power Modes 9
4.3. Cooling 9
4.4. LED Functions 9
4.5. Audio Connections 10
4.6. Gain Structure 10
5.7 Limiters 10
5. Equalisation 11
6. Arraying 12
7. Dimensions 13
8. Rigging and Safety Procedures 18
9. Service Parts & Accessories 19
10. Technical Specications 20
11. Warranty 29
12. Declaration of Conformity 30
VXP Series Operation Manual rev 3.0.0
4
1. Introduction
1. Introduction
Designed and engineered in a unique partnership between Tannoy and Lab.gruppen, the VXP Series
comprises a range of powered (active) loudspeakers for demanding professional and commercial sound
applications. Each incorporates acclaimed Dual Concentric™ driver technology in tandem with on-board
powering by Lab.gruppen’s IDEEA™ (IntelliDrive Energy Efcient Amplier) module.
All VXP Series loudspeakers are designed to perform with very high efciency and exceptionally low distortion,
even when operating near peak output levels. At the heart of VXP Series is the latest genearation of Dual
Concentric loudspeaker technology, which combines a high frequency driver and a low-mid driver on a
common axis to create a true point source for all reproduced sounds. Dual Concentric eliminates the time
alignment problems inherent with all separated driver enclosures, ensuring outstanding denition, detail and
intelligibility at all points in the listening area.
Paired with Dual Concentric driver technology is the new IDEEA powering module from Tannoy’s sister
company in Sweden, Lab.gruppen. At the heart of the IDEEA module is a patented Class D output stage
capable of sustained high power levels with very low distortion – all with near 90% efciency. A universal
switching power supply accepts any mains voltage from 100 - 240 V (+/- 10%) at 50 Hz or 60 Hz through the
appropriate IEC cord. The power control selector supports two operational modes: in Auto mode, the system
turns on with signal present and turns off after 20 minutes of no signal input; manual mode allows the speaker
to be turned on and off as required. Also provided is a switchable 90 Hz high-pass lter for use when adding
a subwoofer. To ensure a long and trouble-free service life, IDEEA modules incorporate extensive features to
safeguard internal circuits and the driver complement.
Within the VXP Series, system designers can choose from a variety of sizes, power levels and coverage
patterns to suit particular requirements. For extended bass performance, models with the “.2” designation
augment the Dual Concentric LF driver with a second matched LF driver. The “HP” designation indicates
extended power handling capabilities, while the “Q” sufx indicates incorporation on the new Q-Centric
Waveguide (QCW™) for applications requiring an asymmetrical coverage pattern. The QCW horn can be
rotated in a matter of minutes, allowing placement of the 75 x 40 degree pattern with either horizontal or
vertical orientation.
All VXP models are enclosed in rugged birch plywood enclosures, with larger models equipped with doublechamfered Integrip™ recessed handles for easy one- or two-handed carrying. Reecting Tannoy and Lab.
gruppen’s common reputation for reliability, all VXP Series loudspeakers are backed by a ve-year warranty.
VXP Series Operation Manual rev 3.0.0
5
2. Unpacking and Visual Checks
2. Unpacking and Visual Checks
Each Tannoy VXP Series loudspeaker is carefully tested and inspected prior to shipment. After unpacking,
please inspect for any exterior physical damage, and save the carton and any relevant packaging materials in
case the loudspeaker again requires packing and shipping. In the event that damage has been sustained in
transit notify your dealer and the shipping carrier immediately.
2.1. Preliminary Recommendation
VXP Series loudspeakers can produce high sustained output levels for long periods of time. If users are in
close proximity, these levels could lead to permanent hearing damage. Because Tannoy loudspeakers have
a natural-sounding, at frequency response and very low distortion, users may not be aware of the potential
hazard. For continuous exposure to high levels, we recommend use of a sound level meter to ensure noise
levels are within safety limits. The meter should be capable of integrating levels over a period of exposure in
conformance with noise control standards.
VXP Series Operation Manual rev 3.0.0
6
3. Rear Interface Panel
XLR FEMALE AUDIO INPUT - This is a lockable
XLR line input socket for connection to the audio
source. Fully balanced: pin 2 hot (+), pin 3 cold (+),
& pin 1 ground.
XLR MALE AUDIO LINK - This is a lockable XLR
line output socket to link additional speakers.
Fully balanced: pin 2 hot (+), pin 3 cold (+),
& pin 1 ground.
POWER MODE SWITCH (right) – Selects AUTO or
MANUAL power on/off mode.
HPF MODE SWITCH – Inserts or removes
90 Hz high pass lter.
3. Rear Interface Panel
LEVEL CONTROL – Recessed potentiometer for
adjustment of speaker volume.
LED INDICATORS – Top to bottom:
Limit protect indicates activity of built-in speaker
protection limiter.
Signal indicates when audio signal is present at
the input.
Power state LED (Red) = StandBy
Power state LED (Green) = Active
Power state LED (Amber) = Temp protection active.
Since we have the auto power on/off functionality,
there are mulitple ways for this LED to change colour
(Red/green).
ROCKER POWER SWITCH - Supplies AC power
on to the unit (100 V - 240 V)
NOTE- WHEN USING AN EXTERNAL DIGITAL CROSSOVER THE FULL RANGE VXP SPEAKERS CAN BE SET TO FULL RANGE MODE
RIGHT LINE
LEVEL
OUTPUT
TDX1 or VNet SC1
TO AUDIO
INPUT
LINE LEVELOUTPUT TOADDITIONAL
SPEAKER
LINE LEVELOUTPUT TOADDITIONAL
SPEAKER
TO AUDIO
INPUT
MIXER ORPRE-AMP
A. STEREO FULL RANGE
VXP
SPEAKER
VXP
SPEAKER
MIXER ORPRE-AMP
RIGHT LINELEVEL OUTPUT
LEFT LINE
LEVEL OUTPUT
TO AUDIO
INPUT
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
LINE LEVELOUTPUT TO
ADDITIONAL
SPEAKER
SET TO
‘FULL RANGE’
MODE
SET TO
‘FULL RANGE’
MODE
TO AUDIO
INPUT
4. Operation
All loudspeakers in the VXP range are integrated designs which include system specic EQ and protection
circuitry, without the need for external amplication. For room equalization, delay and other commissioning
or setup functions, we recommend you use a VNET SC1 or TDX1 Digital Controller. Below are examples of
common set-ups:
A. STEREO FULL RANGE
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
SET TO
‘FULL RANGE’
MODE
VXP
SPEAKER
TO AUDIO
INPUT
LEFT LINE
LEVEL OUTPUT
TO AUDIO
INPUT
RIGHT LINE
LEVEL OUTPUT
VXP
SPEAKER
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
SET TO
‘FULL RANGE’
MODE
MIXER OR
PRE-AMP
B. STEREO SYSTEM STEREO SUB
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
SET TO
HIGH PASS
MODE
NOTE- ON POWER V SUB WOOFERS - SET LOW PASS FILTER TO POSITION ‘A’ (80 Hz) WHEN USED WITH
EITHER POWER V12, V12HP OR V15. SET TO POSITION B (110 Hz) WHEN USED WITH EITHER POWER V6 OR V8.
SPEAKER
LINE LEVEL LOOP
THROUGH
POWER V
SUBWOOFER
VXP
TO AUDIO
INPUT
LEFT LINE
LEVEL
OUTPUT
MIXER OR
TO AUDIO
LEFT LINE
LEVEL
OUTPUT
PRE-AMP
INPUT
LINE LEVEL LOOP
THROUGH
VXP
SPEAKER
POWER V
SUBWOOFER
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
SET TO
HIGH PASS
MODE
C. STEREO SYSTEM WITH MONO SUB
VXP
HIGH PASS
LEFT LINE
LEVEL
OUTPUT
SPEAKER
TDX1 or VNet SC1
RIGHT LINE
LEVEL
OUTPUT
MIXER OR
PRE-AMP
TO AUDIO
INPUT
HIGH PASS
OUTPUT RIGHT
MONO LOWPASS
OUTPUT
TO AUDIO
INPUT
RIGHT LINE
LEVEL OUTPUT
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
OUTPUT LEFT
NOTE- WHEN USING AN EXTERNAL DIGITAL CROSSOVER THE FULL RANGE VXP SPEAKERS
CAN BE SET TO FULL RANGE MODE
VXP
SPEAKER
POWER V
SUBWOOFER
LINE LEVEL
OUTPUT TO
ADDITIONAL
SPEAKER
VXP Series Operation Manual rev 3.0.0
8
4. Operation
4.1. Preliminary Recommendation
VXP products are equipped with Neutrik powerCON mains connectors which mate with the Neutrik NAC3FCA
Cable connector, quick lock with a securing lever for power-in. This AC mains connector is supplied with each
VXP product.
The IDEAA™ module in VXP loudspeakers has a universal power supply. It will operate on any AC mains supply
from 70 V to 265 V (+/- 10%) at 50 or 60 Hz, although with reduced power output capability at the low voltage
extremes 100-240 V (+/-10%). The module will continue to function down to 70 Vac, but with reduced output
power capabilities. This allows continued operation even when using long, thin power cables, or when powered
from portable generators that are unable to maintain full nominal voltage.
4.2. Auto and Manual Power Modes
VXP loudspeakers are designed to meet the requirements of the Energy Star 2.0 specication. The IDEEA
module is highly efcient in operation, regardless of levels or program material, and has a STANDBY power
consumption of less than 0.5 W. It also offers two modes for power on/off.
AUTO mode – This is the default mode as delivered. AUTO engages the Auto Power Down (APD) feature which
puts the IDEAA™ module in STANDBY if no input signal is detected for a period of 20 minutes. The Auto Power
On (APO) turns the module on in less than 2 seconds after a signal is present at the input.
MANUAL MODE – The power mode may be switched to MANUAL to disable the APD and APO functions.
This allows use of an external power sequencer or manual control. Because of the very low idle current
consumption, good overall efciency is maintained even when the MANUAL mode is selected.
4.3. Cooling
Do not install this equipment in an enclosed space. Do not limit free ventilation and movement of air around the
back panel. Ensure that there is at least 100 mm (4”) of space around all sides of the product for ventilation. VXP
products do not have cooling fans; the highly efcient switch mode power supply and proprietary Class D output
stage have less current draw and therefore require only the convection cooling provided by the rear panel heat sink.
4.4. LED Functions
Limit LED - When illuminated this indicates that the system is approaching clipping. An occasional icker of the
red LED on the loudest peaks is acceptable. If this LED remains red for more than the duration of brief dynamic
peaks, or lights continuously then the system is being overdriven. If the red LED illuminates excessively:
• Reduce the input level (see interface panel)
• Reduce the output level of the mixer, or other source to the speaker.
Signal LED – The Green LED indicates that a useable signal is present at the input.
Power LED – StandBy - Red
Active - Green
Temp Prot. - Amber
VXP Series Operation Manual rev 3.0.0
9
4. Operation
4.5. Audio Connections
The signal input & link connectors are fully balanced. When connecting a balanced signal be sure to wire to the
following standard:
SIGNAL XLR CONNECTOR
Hot (+) Pin 2
Cold (-) Pin 3
Shield (GND) Pin 1
In a standard balanced interconnection there are two signal conductors and a shield. The shield is normally
referenced to ground at one or both ends. Many times the shield is lifted at one end, usually at the input to
eliminate “ground loops” or noise. This should be done only as a last resort; although it will reduce hum, the
shields can act as radio antennas and pick up radio frequency interference from the environment.
Multiple enclosures may be driven from a single audio source; simply plug the signal source output into the rst
XLR input socket, and patch that speaker’s XLR link to the next speaker’s XLR input socket.
4.6. Gain Structure
The VXP gain structure is designed to allow a low-level source device to drive the loudspeaker to full output.
Maximum specied SPL will be achieved with a 4 dBu input signal. There is sufcient headroom in the signal
path to accommodate input levels of 10 or even 20 dBu, with high quality compression engaged as needed to
maintain sonic integrity without clipping. To avoid any compression, or when a lower SPL output is desired,
the input attenuator on the rear panel can be used to reduce gain/sensitivity.
5.7 Limiters
The limiters are carefully set-up to preserve the loudspeaker’s dynamic headroom by allowing short term
transients to pass; audible degradation will only become apparent when the limit indication is on constantly.
The limiting functions will protect the amplier from long term overheating by attenuating voltage to the drive
units. If used irresponsibly (constant hard clipping) sound quality will be compromised. In extreme cases drive
units may also be damaged.
VXP Series Operation Manual rev 3.0.0