Tannoy VXP Operation Guide

VXP Series

Professional Loudspeakers

Operation Manual

Important Safety Instructions

Important Safety Instructions

The lightning ash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage " within the product's enclosure that may be of su cient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

1.Read these instructions.

2.Keep these instructions

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug had two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments / accessories specified by the manufacturer.

12.Use only with the cart stand, tripod, bracket or mount table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart / apparatus combination to avoid injury from tip-over.

13.Unplug this apparatus during lightening storms or when unused for long periods of time.

14.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

SAFETY WARNING

Permanent disconnection from the mains supply is achieved by removing the power cord from the mains supply outlet.

UNDER NO CIRCUMSTANCES SHOULD YOU BREAK THE POWER USING THE powerCON CONNECTOR.

SAFETY WARNING

Do not remove any covers, loosen any fixings or allow items to enter any aperture

SAFETY WARNING

Objects filled with liquids should not be placed on this apparatus.

SAFETY WARNING

The rear heatsink on this product gets hot. Avoid direct skin contact during operation and for at least 5 minutes after power has been isolated.

AVERTISSEMENT DE SECURITE

Pour déconnecter l’appareil de l’alimentation principale de façon permanente, débranchez le connecteur du câble fourni à l’arrière de l’appareil.

AVERTISSEMENT DE SECURITE

Ne retirez pas les couvercles, ne desserrez pas les fixations et ne laissez aucune pièce s’introduire dans les ouvertures.

AVERTISSEMENT DE SECURITE

Ne placez pas d’objets contenant du liquide à proximité de l’appareil.

AVERTISSEMENT DE SECURITE

Le radiateur arrière de cet appareil devient chaud. Evitez tout contact direct avec la peau pendant le fonctionnement et au moins 5 minutes après la mise hors tension de l’appareil.

2 VXP Series Operation Manual rev 3.0.0

Installation Instructions

1.THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord provided with a green or green and yellow core which must be connected to the protective earthing terminal of the detachable Neutrik ‘powerCON’ type NEC3FCA connector (Tannoy part number 3461 0919) as supplied with the equipment. The other end of the green or green and yellow conductor must be connected to the earthing pin of a suitable mains plug or the earthing terminal of the installation. The cord must be of maximum length 7.5 meters, rated SJ, SJT, or SJE, 10A minimum and be marked VW-1.

2.The electrical power connection to this product is only to

be made via a detachable Neutrik ‘powerCON’ type NEC3FCA connector (Tannoy part number 3461 0919) as supplied with the equipment. Wiring to this connector must be made

by suitably qualified personnel and must comply with all local requirements.

3.Do not install this equipment in an enclosed space. Do not limit free ventilation and movement of air around the back panel. Ensure that there is at least 100 mm (4”) of space around all sides of the product for ventilation. Only use attachments and accessories approved or specified by Tannoy.

FOR CUSTOMERS IN EUROPE

This product complies with both the LVD (electrical safety) 73/23/EEC and EMC (electromagnetic compatibility) 89/336/ EEC directives issues by the commission of the European community. Compliance with these directives implies conformity with the following European standards:

EN60065 Product safety EN55103-1 EMC emissions EN55103-2 EMC immunity

This product is intended for the following electromagnetic environments: E2; E3 & E4. Environment E1 (domestic) is specifically excluded.

FOR CUSTOMERS IN THE USA & CANADA

This product has been tested for electrical safety and complies with:

UL60065 7th edition

CA/CSA C22.2 No.60065-03 EMC

This equipment has been designed to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

Industry Canada Class A emission compliance statement:

This Class B digital apparatus complies with Canadian ICES-003. Avis de conformite’ a’ la re’glementation d’Industrie Canada, cet appareil nume’rique de classe A est conforme a’ la norme ICES003.

VXP Series Operation Manual rev 3.0.0

3

Table of Contents

Table of Contents

1.

Introduction

5

2.

Unpacking and Visual Checks

6

 

2.1. Preliminary Recommendation

6

3.

Rear Interface Panel

7

4.

Operation

8

 

4.1. Preliminary Recommendation

9

 

4.2. Auto and Manual Power Modes

9

 

4.3. Cooling

9

 

4.4. LED Functions

9

 

4.5. Audio Connections

10

 

4.6. Gain Structure

10

 

5.7 Limiters

10

5.

Equalisation

11

6.

Arraying

12

7.

Dimensions

13

8.

Rigging and Safety Procedures

18

9.

Service Parts & Accessories

19

10. Technical Specifications

20

11. Warranty

29

12. Declaration of Conformity

30

4 VXP Series Operation Manual rev 3.0.0

1. Introduction

1. Introduction

Designed and engineered in a unique partnership between Tannoy and Lab.gruppen, the VXP Series comprises a range of powered (active) loudspeakers for demanding professional and commercial sound applications. Each incorporates acclaimed Dual Concentric™ driver technology in tandem with on-board powering by Lab.gruppen’s IDEEA™ (IntelliDrive Energy Efficient Amplifier) module.

All VXP Series loudspeakers are designed to perform with very high efficiency and exceptionally low distortion, even when operating near peak output levels. At the heart of VXP Series is the latest genearation of Dual Concentric loudspeaker technology, which combines a high frequency driver and a low-mid driver on a common axis to create a true point source for all reproduced sounds. Dual Concentric eliminates the time alignment problems inherent with all separated driver enclosures, ensuring outstanding definition, detail and intelligibility at all points in the listening area.

Paired with Dual Concentric driver technology is the new IDEEA powering module from Tannoy’s sister company in Sweden, Lab.gruppen. At the heart of the IDEEA module is a patented Class D output stage capable of sustained high power levels with very low distortion – all with near 90% efficiency. A universal switching power supply accepts any mains voltage from 100 - 240 V (+/- 10%) at 50 Hz or 60 Hz through the appropriate IEC cord. The power control selector supports two operational modes: in Auto mode, the system turns on with signal present and turns off after 20 minutes of no signal input; manual mode allows the speaker to be turned on and off as required. Also provided is a switchable 90 Hz high-pass filter for use when adding a subwoofer. To ensure a long and trouble-free service life, IDEEA modules incorporate extensive features to safeguard internal circuits and the driver complement.

Within the VXP Series, system designers can choose from a variety of sizes, power levels and coverage patterns to suit particular requirements. For extended bass performance, models with the “.2” designation augment the Dual Concentric LF driver with a second matched LF driver. The “HP” designation indicates extended power handling capabilities, while the “Q” suffix indicates incorporation on the new Q-Centric Waveguide (QCW™) for applications requiring an asymmetrical coverage pattern. The QCW horn can be rotated in a matter of minutes, allowing placement of the 75 x 40 degree pattern with either horizontal or vertical orientation.

All VXP models are enclosed in rugged birch plywood enclosures, with larger models equipped with doublechamfered Integrip™ recessed handles for easy oneor two-handed carrying. Reflecting Tannoy and Lab. gruppen’s common reputation for reliability, all VXP Series loudspeakers are backed by a five-year warranty.

VXP Series Operation Manual rev 3.0.0

5

2. Unpacking and Visual Checks

2. Unpacking and Visual Checks

Each Tannoy VXP Series loudspeaker is carefully tested and inspected prior to shipment. After unpacking, please inspect for any exterior physical damage, and save the carton and any relevant packaging materials in case the loudspeaker again requires packing and shipping. In the event that damage has been sustained in transit notify your dealer and the shipping carrier immediately.

2.1. Preliminary Recommendation

VXP Series loudspeakers can produce high sustained output levels for long periods of time. If users are in close proximity, these levels could lead to permanent hearing damage. Because Tannoy loudspeakers have a natural-sounding, flat frequency response and very low distortion, users may not be aware of the potential hazard. For continuous exposure to high levels, we recommend use of a sound level meter to ensure noise levels are within safety limits. The meter should be capable of integrating levels over a period of exposure in conformance with noise control standards.

6 VXP Series Operation Manual rev 3.0.0

Tannoy VXP Operation Guide

3. Rear Interface Panel

3. Rear Interface Panel

XLR FEMALE AUDIO INPUT - This is a lockable XLR line input socket for connection to the audio source. Fully balanced: pin 2 hot (+), pin 3 cold (+), & pin 1 ground.

XLR MALE AUDIO LINK - This is a lockable XLR line output socket to link additional speakers. Fully balanced: pin 2 hot (+), pin 3 cold (+),

& pin 1 ground.

POWER MODE SWITCH (right) – Selects AUTO or MANUAL power on/off mode.

HPF MODE SWITCH – Inserts or removes 90 Hz high pass filter.

LEVEL CONTROL – Recessed potentiometer for adjustment of speaker volume.

LED INDICATORS – Top to bottom:

Limit protect indicates activity of built-in speaker protection limiter.

Signal indicates when audio signal is present at the input.

Power state LED (Red) = StandBy Power state LED (Green) = Active

Power state LED (Amber) = Temp protection active. Since we have the auto power on/off functionality, there are mulitple ways for this LED to change colour (Red/green).

ROCKER POWER SWITCH - Supplies AC power on to the unit (100 V - 240 V)

AC MAINS CONNECTOR - Neutrik powerCON mains connector (mating connector supplied)

XLR FEMALE

AUDIO INPUT

XLR MALE

AUDIO LINK

HPF MODE SWITCH

POWER MODE SWITCH

LEVEL CONTROL

LED INDICATORS

AC MAINS ROCKER CONNECTOR POWER SWITCH

VXP Series Operation Manual rev 3.0.0

7

4. Operation

4. Operation

All loudspeakers in the VXP range are integrated designs which include system specific EQ and protection circuitry, without the need for external amplification. For room equalization, delay and other commissioning or setup functions, we recommend you use a VNET SC1 or TDX1 Digital Controller. Below are examples of common set-ups:

A. STEREO FULL RANGE

 

VXP

VXP

 

LINE LEVEL

SPEAKER

SPEAKER

LINE LEVEL

OUTPUT TO

 

 

OUTPUT TO

ADDITIONAL

TO AUDIO

TO AUDIO

ADDITIONAL

SPEAKER

INPUT

INPUT

SPEAKER

SET TO

 

 

SET TO

‘FULL RANGE’

 

 

‘FULL RANGE’

MODE

LEFT LINE

RIGHT LINE

MODE

 

 

 

LEVEL OUTPUT

LEVEL OUTPUT

 

 

MIXER OR

 

 

PRE-AMP

 

B. STEREO SYSTEM STEREO SUB

 

VXP

 

VXP

 

LINE LEVEL

SPEAKER

 

SPEAKER

LINE LEVEL

OUTPUT TO

 

 

 

OUTPUT TO

ADDITIONAL

 

TO AUDIO

TO AUDIO

ADDITIONAL

SPEAKER

 

INPUT

INPUT

SPEAKER

SET TO

 

 

SET TO

HIGH PASS

LINE LEVEL LOOP

LINE LEVEL LOOP

HIGH PASS

MODE

MODE

 

THROUGH

THROUGH

 

 

LEFT LINE

LEFT LINE

 

 

LEVEL

LEVEL

 

 

OUTPUT

OUTPUT

 

POWER V

 

 

 

POWER V

 

 

 

MIXER OR

SUBWOOFER

SUBWOOFER

 

PRE-AMP

 

NOTEON POWER V SUB WOOFERS - SET LOW PASS FILTER TO POSITION ‘A’ (80 Hz) WHEN USED WITH EITHER POWER V12, V12HP OR V15. SET TO POSITION B (110 Hz) WHEN USED WITH EITHER POWER V6 OR V8.

C. STEREO SYSTEM WITH MONO SUB

 

 

VXP

 

VXP

 

LINE LEVEL

SPEAKER

 

SPEAKER

LINE LEVEL

OUTPUT TO

 

 

 

OUTPUT TO

ADDITIONAL

 

TO AUDIO

TO AUDIO

ADDITIONAL

SPEAKER

 

INPUT

INPUT

SPEAKER

 

 

 

RIGHT LINE

 

HIGH PASS

 

HIGH PASS

LEVEL OUTPUT

 

OUTPUT LEFT

OUTPUT RIGHT

 

 

 

TDX1 or VNet SC1

 

 

 

 

MONO LOWPASS

 

 

 

OUTPUT

 

 

LEFT LINE

RIGHT LINE

 

LEVEL

LEVEL

 

OUTPUT

OUTPUT

POWER V

 

 

MIXER OR

SUBWOOFER

PRE-AMP

 

NOTEWHEN USING AN EXTERNAL DIGITAL CROSSOVER THE FULL RANGE VXP SPEAKERS CAN BE SET TO FULL RANGE MODE

8 VXP Series Operation Manual rev 3.0.0

4. Operation

4.1. Preliminary Recommendation

VXP products are equipped with Neutrik powerCON mains connectors which mate with the Neutrik NAC3FCA Cable connector, quick lock with a securing lever for power-in. This AC mains connector is supplied with each VXP product.

The IDEAA™ module in VXP loudspeakers has a universal power supply. It will operate on any AC mains supply from 70 V to 265 V (+/- 10%) at 50 or 60 Hz, although with reduced power output capability at the low voltage extremes 100-240 V (+/-10%). The module will continue to function down to 70 Vac, but with reduced output power capabilities. This allows continued operation even when using long, thin power cables, or when powered from portable generators that are unable to maintain full nominal voltage.

4.2. Auto and Manual Power Modes

VXP loudspeakers are designed to meet the requirements of the Energy Star 2.0 specification. The IDEEA module is highly efficient in operation, regardless of levels or program material, and has a STANDBY power consumption of less than 0.5 W. It also offers two modes for power on/off.

AUTO mode – This is the default mode as delivered. AUTO engages the Auto Power Down (APD) feature which puts the IDEAA™ module in STANDBY if no input signal is detected for a period of 20 minutes. The Auto Power On (APO) turns the module on in less than 2 seconds after a signal is present at the input.

MANUAL MODE – The power mode may be switched to MANUAL to disable the APD and APO functions. This allows use of an external power sequencer or manual control. Because of the very low idle current consumption, good overall efficiency is maintained even when the MANUAL mode is selected.

4.3. Cooling

Do not install this equipment in an enclosed space. Do not limit free ventilation and movement of air around the back panel. Ensure that there is at least 100 mm (4”) of space around all sides of the product for ventilation. VXP products do not have cooling fans; the highly efficient switch mode power supply and proprietary Class D output stage have less current draw and therefore require only the convection cooling provided by the rear panel heat sink.

4.4. LED Functions

Limit LED - When illuminated this indicates that the system is approaching clipping. An occasional flicker of the red LED on the loudest peaks is acceptable. If this LED remains red for more than the duration of brief dynamic peaks, or lights continuously then the system is being overdriven. If the red LED illuminates excessively:

Reduce the input level (see interface panel)

Reduce the output level of the mixer, or other source to the speaker.

Signal LED – The Green LED indicates that a useable signal is present at the input.

Power LED – StandBy - Red

Active - Green

Temp Prot. - Amber

VXP Series Operation Manual rev 3.0.0

9

4. Operation

4.5. Audio Connections

The signal input & link connectors are fully balanced. When connecting a balanced signal be sure to wire to the following standard:

SIGNAL

XLR CONNECTOR

Hot (+)

Pin 2

Cold (-)

Pin 3

Shield (GND)

Pin 1

In a standard balanced interconnection there are two signal conductors and a shield. The shield is normally referenced to ground at one or both ends. Many times the shield is lifted at one end, usually at the input to eliminate “ground loops” or noise. This should be done only as a last resort; although it will reduce hum, the shields can act as radio antennas and pick up radio frequency interference from the environment.

Multiple enclosures may be driven from a single audio source; simply plug the signal source output into the first XLR input socket, and patch that speaker’s XLR link to the next speaker’s XLR input socket.

4.6. Gain Structure

The VXP gain structure is designed to allow a low-level source device to drive the loudspeaker to full output. Maximum specified SPL will be achieved with a 4 dBu input signal. There is sufficient headroom in the signal path to accommodate input levels of 10 or even 20 dBu, with high quality compression engaged as needed to maintain sonic integrity without clipping. To avoid any compression, or when a lower SPL output is desired, the input attenuator on the rear panel can be used to reduce gain/sensitivity.

5.7 Limiters

The limiters are carefully set-up to preserve the loudspeaker’s dynamic headroom by allowing short term transients to pass; audible degradation will only become apparent when the limit indication is on constantly. The limiting functions will protect the amplifier from long term overheating by attenuating voltage to the drive units. If used irresponsibly (constant hard clipping) sound quality will be compromised. In extreme cases drive units may also be damaged.

10 VXP Series Operation Manual rev 3.0.0

Loading...
+ 22 hidden pages