The lightning ash with arrowhead symbol within anequilateral triangle, is intended to alert the user to thepresence of uninsulated "dangerous voltage " within theproduct's enclosure that may be of sucient magnitudeto constitute a risk of electric shock to persons.
Important Safety Instructions
The lightning ash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage " within the
product's enclosure that may be of sucient magnitude
to constitute a risk of electric shock to persons.
1. Read these instructions.
2. Keep these instructions
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance
with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers that
produce heat.
9. Only use attachments/accessories specied by the manufacturer.
10. Use only with a cart, stand, tripod, bracket, or table
specied by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
11. Refer all servicing to qualied service personnel. Servicing
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
SAFETY WARNING
Do not remove any covers, loosen any xings or allow
items to enter any aperture.
SAFETY WARNING
Objects lled with liquids should not be placed on
this apparatus.
AVERTISSEMENT DE SECURITE
Ne retirez pas les couvercles, ne desserrez pas les xations et
ne laissez aucune pièce s’introduire dans les ouvertures.
AVERTISSEMENT DE SECURITE
Ne placez pas d’objets contenant du liquide à proximité de
l’appareil
.
VX Series Operation Manual rev 3.1.0
2
Table of Contents
Table of Contents
1. Introduction 4
2. Unpacking and Visual Checks 4
2.1 Preliminary Recommendation4
3. Connectors / Cabling 5
4. Polarity Checking 6
5. Amplication & Power Handling 6
6. Crossovers and Bi-amp Conguration 7
7. Equalisation 9
8. Arraying 9
9. Dimensions 10
10. Rigging and Safety Procedures 16
11. Service Parts & Accessories 17
12. Technical Specications 18
13. Warranty 22
14. Declaration of Conformity 23
VX Series Operation Manual rev 3.1.0
3
1. Introduction
1. Introduction
Designed, engineered and built in the United Kingdom, the VX Series from Tannoy comprises a range of
passive loudspeakers for demanding professional and commercial sound applications. At the heart of all VX
Series loudspeakers is Tannoy’s acclaimed Dual ConcentricTM driver technology. Unlike conventional drivers,
Dual Concentric combines a high frequency driver and a low-mid driver on a common axis, creating a true
point source for all reproduced sounds. Dual Concentric eliminates the time alignment problems inherent with
all enclosures employing separated drivers, thus ensuring outstanding denition, detail and intelligibility at all
points in the listening area.
All VX Series loudspeakers are designed to perform with very high efciency and exceptionally low distortion,
even when operating near peak output levels. All components are housed in rugged birch plywood enclosures,
with larger models equipped with double-chamfered Integrip™ recessed handles for easy one- or two-handed
carrying. Reecting Tannoy’s reputation for reliability, all VX Series loudspeakers are backed by a ve-year
wa rrant y.
Within the VX Series, system designers can choose from a variety of sizes, power levels and coverage patterns
to suit particular requirements. For extended bass performance, models with the “.2” designation augment the
Dual Concentric LF driver with a second matched LF driver. The “HP” designation indicates extended power
handling capabilities, while the “Q” sufx indicates incorporation on the new Q-Centric WaveguideTM (QCW™)
for applications requiring an asymmetrical coverage pattern. The QCW horn can be rotated in a matter of
minutes, allowing placement of the 75 x 40 degree pattern with either horizontal or vertical orientation.
2. Unpacking and Visual Checks
Each Tannoy VX Series loudspeaker is carefully tested and inspected prior to shipment. After unpacking,
please inspect for any exterior physical damage, and save the carton and any relevant packaging materials in
case the loudspeaker again requires packing and shipping. In the event that damage has been sustained in
transit notify your dealer and the shipping carrier immediately.
2.1 Preliminary Recommendation
VX Series loudspeakers can produce high sustained output levels for long periods of time. If users are in close
proximity, these levels could lead to permanent hearing damage. Because Tannoy loudspeakers have a naturalsounding, at frequency response and very low distortion, users may not be aware of the potential hazard. For
continuous exposure to high levels, we recommend use of a sound level meter to ensure noise levels are within
safety limits. The meter should be capable of integrating levels over a period of exposure in conformance with
noise control standards.
VX Series Operation Manual rev 3.1.0
4
3. Connectors / Cabling
3. Connectors / Cabling
On VX Series loudspeakers, connector types available vary by model, as detailed below:
VX 5.2, VX 6, VX 8
Inputs on 1 x speakON® 4-pole, 1x binding post pair. Binding posts are connected in parallel to speakON® 1+
and 1-. Not bi-amp capable.
VX 8M
Inputs on 2 paralleled speakON 4 pole connectors. Not bi-amp capable
VX 8.2, VX 12
Inputs on 2 x speakON® 4-pole and 2 x barrier strip terminals. Both barrier strip terminal pairs are connected in
parallel to speakON® poles 1+ and 1-. Not bi-amp capable.
VX 12HP, VX 12Q, VX 12.2Q, VX 15HP, VX 15Q
Inputs on 2 x speakON® 4-pole and 2x barrier strip terminal pair. Both barrier strip terminal pairs are connected
in parallel to speakON® poles 1+ and 1- when congured for full range operation. Bi-amp conguration may be
implemented using speakON® connectors only. (See 6.0 below.)
Binding post terminals are capable of accepting cables with a conductor of up to 6 mm sq CSA (AWG 10). Red is positive
and black is negative.
Barrier strips accept wire up to 4 mm sq CSA (AWG 12). Barrier strip polarity is as indicated.
The speakON® connectors will accept wire up to 4 mm sq CSA (AWG 12) with an outside diameter of up to 15 mm and
a current rating of 30 A. When so equipped, the pins of the two speakON® sockets identied input/output on the rear
of the input panel are paralleled within the enclosure. Tannoy have adopted the conventional wiring standard for the VX
Series product: pin 1+ is positive pin 1- is negative. For a worldwide list of Neutrik® distributors see www.neutrik.com.
When choosing cable type, it is important select the correct cross sectional area in relation to the cable length and
the load impedance. A small cross sectional area will increase the cable’s series resistance, inducing power loss and
response variations (damping factor). Connectors wired with 2.5 sq. mm (12 gauge) cable will be satisfactory under normal
conditions; with very long cable runs, the wire size should be increased. Please refer to the following table for guidance:
Cable run (m)
10
25
50
100
C.S.A of Each
Conductor
2.5
4.0
6.0
2.5
4.0
6.0
2.5
4.0
6.0
2.5
4.0
6.0
Cable resistance
(ohms)
0.14
0.09
0.06
0.14
0.09
0.06
0.14
0.09
0.06
0.14
0.09
0.06
% Power loss
into 8 ohms
load
1.7
1.1
0.73
1.7
1.1
0.73
1.7
1.1
0.73
1.7
1.1
0.73
% Power loss
into 4 ohms
load
3.5
2.2
1.5
3.5
2.2
1.5
3.5
2.2
1.5
3.5
2.2
1.5
VX Series Operation Manual rev 3.1.0
5
4. Polarity Checking
4. Polarity Checking
Checking the polarity of the wiring before the speaker system is mounted or own will help ensure satisfactory
performance. If you do not have a pulse based polarity checker, you may check LF units as follows: Connect
two wires to the + and - terminals of a PP3 (9 V) battery. Apply the wire connected to the positive (+) terminal
of the battery to the speaker cable leg which you believe to be connected to pin 1+ of the speaker connector;
likewise connect the negative (-) terminal of the battery to pin 1-. If you have wired it correctly, the LF drive unit
will move forward. At this point, connect the positive (+) speaker lead to the + terminal on the amplier and the
negative (-) lead to the - terminal on the amplier. However, if the LF driver moves backwards with the battery
test, the input connections need to be inverted before connecting the amplier. If problems are encountered,
inspect the cable wiring. Note that different amplier manufacturers may utilise different pin congurations and
polarity conventions; if you are using ampliers from more than one manufacturer, check the polarity at the
ampliers as well as at the loudspeakers.
5. Amplification & Power Handling
As with all professional loudspeaker systems, the power handling is a function of voice coil thermal capacity.
Care should be taken to avoid overdriving the amplier into clipping. Damage to the loudspeaker will be
sustained if the amplier is driven into clipping for any extended period of time. Headroom of at least 3 dB
should be allowed.
When evaluating an amplier, it is important to take into account its behaviour under low impedance load
conditions. A loudspeaker system is highly reactive, and with transient signals it can require more current than
the nominal impedance would indicate. Generally a higher power amplier running free of distortion will do less
damage to the loudspeaker than a lower power amplier that is continually clipping. A high-powered amplier
running at less than 90% of output power generally sounds superior to a lower power amplier running at
100%. An amplier with insufcient drive capability will not allow the full performance or the loudspeaker to be
realised. (See technical specications section for recommended amplier power.)
When using ampliers from different manufacturers in a single installation, make certain that all have very
closely matched gains. (Variation should be less than +/- 0.5 dB.) This precaution is important to the overall
system balance when only a single active crossover is being used with multiple cabinets. When possible, it is
recommended that the same ampliers be used throughout.
VX Series Operation Manual rev 3.1.0
6
6. Crossovers and Bi-amp Configuration
6. Crossovers and Bi-amp Configuration
VX Series loudspeakers are supplied as standard for passive operation via the internal crossover network.
If higher peak outputs and additional low frequency output is required, then the VX Series can be used in
conjunction with the Tannoy TX1 controller/crossover which provides high pass ltering and a degree of
parametric equalisation, as well as a xed crossover point for use with sub-bass loudspeakers (See the TX1
Operation Manual for further information.) The Tannoy TDX2 Digital controller will also perform the above
functions with additional control and features including limiting and delay. (See the relevant literature on the
TDX2 for further information.)
The VX 12HP, VX 12Q, VX 12.2Q, VX 15HP, VX 15Q only also may be internally recongured for bi-amp
operation to supply greater system headroom. Reconguration is as follows.
First, remove the rear termination panel. It is secured with size M2.5 hex screws. Use the proper tool as
screws may be very snug.
In passive (default) mode, the internal wiring is as shown in Fig. 1, with the full range signal routed through the
internal crossover and divided into separate LF and HF signals using a four pole connector.
For bi-amp operation, recongure the internal wiring as shown in Fig 2. The two-wire connector leading to
the crossover is disconnected. The four-wire connector from the speakers now bypasses the crossover and
instead connects directly to the speakON® inputs, replacing the connector that previously led to the crossover.
For bi-amp operation, the speakON® connectors coming from the amplier(s) must be wired as follows:
1 + LF +
1 - LF –
2 + HF +
2 - HF –
Note that the barrier strip terminals are wired for passive full-range operation only.
VX Series Operation Manual rev 3.1.0
7
6. Crossovers and Bi-amp Configuration
Fig 1.
Fig 2.
VX Series Operation Manual rev 3.1.0
8
7. Equalisation
7. Equalisation
VX Series loudspeakers require no equalisation or correction to overcome system limitations; equalisation
is necessary only to compensate for difcult acoustic environments. Over-equalisation can reduce system
headroom and introduce phase distortion, resulting in degraded sound. If equalisation is required, it should
be applied gently and smoothly. Because VX Series loudspeakers are point source, phase coherent designs,
excessive equalization usually proves detrimental to the overall sound quality.
When one loudspeaker is used in close proximity to another, comb ltering effects can create coverage problems.
(Comb ltering creates an uneven frequency response across the coverage area due to constructive and
destructive interference effects between the two sources.) Comb ltering cannot be cured by equalisation;
this should be addressed with proper arraying as discussed in the following section.
8. Arraying
Small alterations to loudspeaker positions can have the effect of minimising problematic combing frequencies.
Arrays should be constructed so that the individual coverage patters of each loudspeaker combine with
minimal overlap. The design of the VXP cabinet greatly simplies the creation of effective arrays, allowing
seamless wide horizontal coverage using two loudspeakers without the need for tedious experimentation.
By placing the VXP cabinets with the 30 degree angled rear panels together, minimal dispersion pattern
overlap is achieved, guaranteeing an extraordinarily smooth transition. In many applications the 90 or 75
degree dispersion pattern may be sufcient in the horizontal plane. It is also possible to stack the cabinets
vertically using the above method (in a central cluster for example) where greater vertical dispersion is required.
As shown in the above diagram, one of the VXP cabinets is inverted to allow the optimum splay angle to be
achieved. The grille can be simply removed from this cabinet and be replaced for matching orientation. The
grille is held in position by the two xing screws on the top and bottom lips of the cabinet.
VX Series Operation Manual rev 3.1.0
9
9. Dimensions
9. Dimensions
VX 5.2
333.0
180.0
[7.09"]
1"]
200.0
[7.87"]
50.8
[2.00"]
37.0
[1.46"]
107.9
[4.25"]
VX 6
125.0
[4.92"]
333.0
[13.11"]
75°
225.0
[8.86"]
75°
215.0
[8.46"]
50.8
[2.00"]
37.0
[1.46"]
107.9
[4.25"]
115.0
75°
[4.53"]
VX Series Operation Manual rev 3.1.0
10
75°
[15.28"
VX 8
388.0
[15.28"]
280.0
[11.02"]
180.0
[7.09"]
275.0
[10.83"]
50.8
[2.00"]
94.0
[3.70"]
107.9
[4.25"]
9. Dimensions
VX 8M
135.0
[5.31"]
388.0
60°
280.0
[11.02"]
]
180.0
[7.09"]
60°
315.7
[12.43"]
175.7
[6.92"]
30°
50°
VX Series Operation Manual rev 3.1.0
11
9. Dimensions
VX 8.2
590.0
[23.23"]
145.0
[5.71"]
280.0
[11.02"]
180.0
[7.09"]
60°
60°
140.0
[5.51"]
328.0
[12.91"]
VX 12
486.0
[19.13"]
190.0
[7.48"]
155.0
370.0
[14.57"]
290.0
[11.42"]
180.0
[7.09"]
60°
40°
360.0
[14.17"]
180.0
[7.09"]
406.0
[15.98"]
70.0
[2.76"]
[6.10"]
127.0
[5.00"]
224.0
[8.82"]
VX Series Operation Manual rev 3.1.0
12
9. Dimensions
VX 12HP
486.0
[19.13"]
190.0
[7.48"]
60°
370.0
[14.57"]
290.0
[11.42"]
180.0
[7.09"]
40°
360.0
[14.17"]
180.0
[7.09"]
406.0
[15.98"]
70.0
[2.76"]
155.0
[6.10"]
127.0
[5.00"]
224.0
[8.82"]
VX 12Q
486.0
[19.13"]
190.0
[7.48"]
60°
370.0
[14.57"]
290.0
[11.42"]
180.0
[7.09"]
40°
360.0
[14.17"]
180.0
[7.09"]
406.0
[15.98"]
70.0
[2.76"]
127.0
[5.00"]
VX Series Operation Manual rev 3.1.0
13
9. Dimensions
C of G
VX 12.2Q
780.0
[30.71"]
370.0
[14.57"]
290.0
[11.42"]
180.0
[7.09"]
190.0
[7.48"]
180.0
[7.09"]
40.0
[1.57"]
40.0
[1.57"]
155.0
[6.10"]
155.0
[6.10"]
292.0
[11.50"]
VX 15HP
190.0
[7.48"]
[16.54"]
420.0
590.0
[23.23"]
200.0
[7.87"]
60°
450.0
[17.72"]
364.0
[14.33"]
180.0
[7.09"]
40°
504.0
[19.84"]
43.0
[1.69"]
203.0
[7.99"]
180.0
[7.09"]
200.0
[7.87"]
161.5
[6.36"]
262.0
[10.31"]
127.0
[5.00"]
183.9
[7.24"]
70.0
[2.76"]
VX Series Operation Manual rev 3.1.0
14
VX 15Q
161.5
[6.36"]
183.9
[7.24"]
9. Dimensions
420.0
[16.54"]
590.0
[23.23"]
200.0
[7.87"]
450.0
[17.72"]
364.0
[14.33"]
180.0
[7.09"]
504.0
[19.84"]
43.0
[1.69"]
180.0
[7.09"]
200.0
[7.87"]
[5.00"]
262.0
[10.31"]
127.0
70.0
[2.76"]
VX Series Operation Manual rev 3.1.0
15
10. Rigging and Safety Procedures
10. Rigging and Safety Procedures
The Tannoy Professional hardware covered in this guide has been designed to offer quick, simple, cost
effective and secure solutions for mounting specic Tannoy Professional loudspeakers. This hardware has been
designed and manufactured with a high safety load factor for its specic role. To ensure the safest possible use
of the hardware covered in this guide, it must be assembled in strict accordance with the instructions specied.
The information in these Operation Manuals relating to the assembly and the safe use of these accessories
must be understood and followed.
The installation of Tannoy Professional loudspeakers - using the dedicated hardware - should carried out only
by fully qualied installers, in accordance with all the required safety codes and standards that apply at the
place of installation. WARNING: As the legal requirements for mounting, suspending, hanging, ying or rigging
equipment change from country to country, please consult your local safety standards ofce before installing
any product. We also recommend that you thoroughly check any laws and bylaws prior to installation.
Tannoy Professional hardware has been designed for use with specic Tannoy Professional loudspeakers,
and is not designed or intended for use with any other Tannoy Professional products, or any other devices.
Using Tannoy Professional hardware for any purpose other than that indicated in this guide is considered to
be improper use. Such use can be very dangerous: overloading, modifying, damaging, or assembling in a
manner other than that clearly stated in the Operation will compromise safety. The component parts of any
Tannoy Professional hardware device must only be assembled using the accessory kits supplied and in strict
compliance with the Operation Manual. The use of other accessories or non-approved methods of assembly
may result in an unsafe hardware system by reducing the load safety factor. Welding, or any other method of
permanently xing hardware components together or to the integral xing points in the cabinet, should never
be used.
Whenever a Tannoy Professional loudspeaker is xed to a surface using a Tannoy Professional hardware
device, the installer must ensure that the surface is capable of safely and securely supporting the load. The
hardware employed must be safely, and securely attached both to the loudspeaker and also to the surface
in question, in accordance with the Operation Manual, using only the xing holes provided as standard and
covered in the manual. Secure xings to the building structure are vital. Seek help from architects, structural
engineers or other specialists if in any doubt. All loudspeakers own in theatres, nightclubs, conference centres
or other places of work and entertainment must be provided with an independent, correctly rated and securely
attached secondary safety restraint in addition to the principal hardware device. This secondary safety restraint
must prevent the loudspeaker from dropping more than 150 mm (6”) should the principal hardware device fail.
VX Series Operation Manual rev 3.1.0
16
11. Service Parts & Accessories
11. Service Parts & Accessories
ModelHF unitDual driverBass driver
VX 5.27900 09157900 12807900 1281--
VX 67900 06837900 0742---
VX 8-7900 1282-7900 1284-
VX 8M-7900 1282-7900 1284-
VX 8.2-7900 12827900 12837900 1284-
VX 12-7900 1285-7900 12877900 0441
VX 12HP-
VX 12Q-
VX 12.2Q-
VX 15HP-
7900 1289*/
7900 1366
7900 1290*/
7900 1364
7900 1290*/
7900 1364
7900 1293*/
7900 1367
-7900 1292
-7900 1292
7900 12917900 1292
-7900 1292
HF
diapharagm
Recone Kit
7900 0716*/
7900 1358
7900 0716*/
7900 1358
7900 0716*/
7900 1358
7900 0646*/
7900 1359
VX 15Q-
* Pre July 2013
7900 1294*/
7900 1367
-7900 1292
7900 0646*/
7900 1359
VX Series Operation Manual rev 3.1.0
17
12. Technical Specifications
v
12. Technical Specifications
Following are the VX Series technical specications. These gures are accurate at the time of printing but please note that all gures are
subject to change without notice.
ModelVX 5.2VX 6VX 8
Performance
Frequency Response (-3 dB)
Frequency Range (-10 dB) 165 Hz – 45kHz80 Hz – 45kHz62 Hz – 45 kHz
System Sensitivity (1 W @1 m)
Dispersion (degrees conical)120 degrees (H) x 90 degrees (V)90 degrees conical90 degrees conical
Driver Complement1 x 125 mm (5.00”) constant1 x 150 mm (6.00”) constant1 x 200 mm (8.00”) constant
FinishTextured black or white paint, Textured black or white paint, Textured black or white paint,
Connectors1 x speakON NL4MP,1 x speakON NL4MP,1 x speakON NL4MP,
Fittings2 x M6 yoke bracket inserts
Dimensions (H x W x D)W: 180 mm (7.1”), W: 225 mm (8.9”), W: 280 mm (11.0”),
Net Weight5.0 kg (11.0 lbs)5.5 kg (12.1 lbs)8.5 kg (18.7 lbs)
Shipped Weight10.5 kg (23.1 lbs)12.5 kg (27.6 lbs)18.5 kg (40.8 lbs)
Packed Quantity222
(1) Average over stated bandwidth. Measured at 1 metre on axis in an anechoic chamber.
(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber.
A full range of measurements, performance data, and EaseTM Data can be downloaded from www.tannoy.com.
Tannoy operates with a policy of continuous research and development. Product performance always will equal or exceed published specications. However, following introduction of new
materials or manufacturing methods, Tannoy reserves the right to alter specications without prior notice.
and internally braceand internally bracevented and internally braced.
with custom colours on request.with custom colours on request.with custom colours on request.Powder coated perforated steel grillePowder coated perforated steel grillePowder coated perforated steel grilleAirnet cloth behindAirnet cloth behindAirnet cloth behind
2 x 4 mm binding posts2 x 4 mm binding posts2 x 4 mm binding posts
(4mm allen key),Fixings compatible with Omnimount and Powerdrive style brackets,4 x M6 inserts
H: 333 mm (13.1”),H: 333 mm (13.1”),H: 388 mm (15.3”),D: 200 mm (7.9”)D: 215 mm (8.1”)D: 275 mm (10.8”)
2 x M6 yoke bracket inserts (4mm allen key),Fixings compatible with Omnimount and Powerdrive style brackets,4 x M6 inserts,Blanking plate for optional VTH pole mount
2 x M10 yoke bracket inserts (6mm allen key),2 x M10 ying inserts,Fixings compatible with Omnimount and Powerdrive style brackets,4 x M6 inserts,Blanking plate for optional VTH pole mount,1 x Integrip carrying handle
VX Series Operation Manual rev 3.1.0
18
12. Technical Specifications
ModelVX 8MVX 8.2VX 12
Performance
Frequency Response (-3 dB)
Frequency Range (-10 dB) 162 Hz – 45 kHz60 Hz – 45 kHz55 Hz – 38 kHz
System Sensitivity (1 W @1 m)
Dispersion (degrees conical)90 degrees conical90 degrees conical90 degrees conical
Driver Complement1 x 200 mm (8.00”) constant1 x 200 mm (8.00”) constant1 x 305 mm (12.00”) constant
CrossoverPassive 1.7 kHzPassive 360 Hz and 1.5 kHzPassive 1 kHz with HF protection
Directivity Factor (Q)6.8 (averaged 1 kHz to 8 kHz)8.1 (averaged 1 kHz to 8 kHz)9.6 (averaged 1 kHz to 8 kHz)
Directivity Index (DI)9.2 (averaged 1 kHz to 8 kHz)9.2 (averaged 1 kHz to 8 kHz)9.8 (averaged 1 kHz to 8 kHz)
Rated Ma ximum SPL (2)Average: 113 dBAverage: 116 dBAverage: 120 dB
Power HandlingAverage: 130 WAverage: 200 WAverage: 200 W
Enclosure16.28 litre, 15 mm (0.62”) birch plywood,24.97 litre, 15 mm (0.62”) birch plywood,36.07 litre, 15 mm (enclosure)
FinishTextured black or white paint, Textured black or white paint, Textured black or white paint,
Connectors2 x speakON NL4MP2 x speakON NL4MP2 x speakON NL4MP
Fittings3 x M10 ying inserts (portrait
Dimensions (H x W x D)W: 280 mm (11.0”), W: 280 mm (11.0”), W: 370 mm ( 14.6”),
Net Weight9 kg (19.8 lbs) 15.5 kg (34.2 lbs) 17.0 kg (37.5 lbs)
Shipped Weight20 kg (44.1 lbs)17.5 kg (38.6 lbs)19.5 kg (43.0 lbs
Packed Quantity211
(1) Average over stated bandwidth. Measured at 1 metre on axis in an anechoic chamber.
(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber.
A full range of measurements, performance data, and EaseTM Data can be downloaded from www.tannoy.com.
Tannoy operates with a policy of continuous research and development. Product performance always will equal or exceed published specications. However, following introduction of new
materials or manufacturing methods, Tannoy reserves the right to alter specications without prior notice.
vented and internally braced.vented and internally braced.and 18 mm (front) birch plywood
with custom colours on request.with custom colours on request.with custom colours on request.Powder coated perforated steel grillePowder coated perforated steel grillePowder coated perforated steel grilleAirnet cloth behindAirnet cloth behindAirnet cloth behind
and Barrier stripand Barrier strip
mounting),1 x Integrip carrying handle,Integral Pole Mount for standard 35mm poles
H: 388 mm (15.3”),H: 590 mm (23.2”),H: 486 mm (19.1”),D: 315.7 mm (12.4”)D: 275 mm (10.8”)D: 360 mm (14.1”)
4 x M10 Flying inserts, 2 x M10 yoke bracket inserts2 x Integrip carrying handlesBlanking plate for optional VTH pole mount
vented and internally braced
8 x M10 Flying inserts (portrait or landscape mounting),8 x M10 yoke bracket inserts,2 x Integrip carrying handles, Blanking plate for optional VTH pole mount,Fixings compatible with Powerdrivestyle brackets,4 x M6 inserts
TM
VX Series Operation Manual rev 3.1.0
19
12. Technical Specifications
v
ModelVX 12HPVX 12QV X 12.2Q
Performance
Frequency Response (-3 dB)
Frequency Range (-10 dB) 160 Hz – 30 kHz60 Hz – 30 kHz55 Hz – 30 kHz
System Sensitivity (1 W @1 m)
Passive - Full Range97 dB (1W = 2.83 V for 8 ohms)97 dB (1W = 2.83 V for 8 ohms)99 dB (1W = 2.83 V for 8 Ohms)
Biamp (LF)98 dB 98 dB98 dB
Biamp (LF)106 dB108 dB102 dB
Dispersion (degrees conical)75 degrees conical75 degrees (H) x 40 degrees (V)75 degrees (H) x 40 degrees (V)
Driver Complement1 x 305 mm (12.00”) 1 x 305 mm (12.00”) PowerDual™1 x 305 mm (12.00”) PowerDual™
Directivity Factor (Q)10.1 (averaged 1 kHz to 10 kHz)13.0 (averaged 1 kHz to 8 kHz)13.0 (averaged 1 kHz to 8 kHz)
Directivity Index (DI)10.0 (averaged 1 kHz to 10kHz)11.1 (averaged 1 kHz to 8 kHz)11.1 (averaged 1 kHz to 8 kHz)
Rated Ma ximum SPL (2)
Passive - Full Range123 dB (average) 129 dB (peak)123 dB (average) 129 dB (peak)126 dB (average) 132 dB (peak)
Biamp (LF )124 dB (average) 130 dB (peak)124 dB (average) 130 dB (peak)123 dB (average) 129 dB (peak)
Biamp (HF )125 dB (average) 131 dB (peak)127 dB (average) 132 dB (peak)127 dB (average) 133 dB (peak)
Power Handling
Passive - Full RangeAverage: 350 WAverage: 350 WAverage: 500 W
Biamp (LF )Average: 350 WAverage: 350 WAverage: 350 W
Biamp (HF )Average: 80 WAverage: 80 WAverage: 350 W
Recommended Amplier Power
Passive - Full Range700 W @ 8 ohms700 W @ 8 ohms1000 W @ 8 ohms
Biamp (LF )700 W @ 8 ohms700 W @ 8 ohms700 W @ 8 ohms
Biamp (HF )160 W @ 8 ohms160 W @ 8 ohms700 W @ 8 ohms
Nominal Impedance8 ohms8 ohms8 ohms
Distortion
10% Full Power (10.2 V)2nd Harmonic 3rd Harmonic2nd Harmonic 3rd Harmonic2nd Harmonic 3rd Harmonic
250 Hz0.239% 0.67%0.72% 0.17%2.49% 0.49%
1 kHz1.58% 2.53%0.57% 0.76%0.54% 0.73%
10 kHz5.2% 0.161%5.11% 0.08%7.54% 0.80%
Distortion
10% Full Power (10.2 V)2nd Harmonic 3rd Harmonic2nd Harmonic 3rd Harmonic2nd Harmonic 3rd Harmonic
250 Hz0.11% 0.581%0.16% 0.19%0.60% 0.21%
1 kHz0.79% 2.53%0.18% 0.49%0.20% 0.49%
10 kHz1.94% 0.1611.63% 0.08%2.56% 0.10%
Product can be recongured forProduct can be recongured forProduct can be recongured forbi-amped operation. Bi-ampbi-amped operation. Bi-ampbi-amped operation. Bi-ampsystem parameters in Operation Manualsystem parameters in Operation Manualsystem parameters in Operation Manual
Enclosure36.07 litre, 15 mm (enclosure) and36.07 litre, 15 mm (enclosure) and59.08 litre, 15 mm (enclosure) and
FinishTextured black or white paint, Textured black or white paint, Textured black or white paint,
Connectors2 x speakON NL4MP and Barrier strip2 x speakON NL4MP and Barrier strip2 x speakON NL4MP and Barrier strip
Fittings8 x M10 Flying inserts (portrait or
Dimensions (H x W x D)W: 370 mm ( 14.6”), W: 370 mm ( 14.6”), W: 370 mm ( 14.6”),
Net Weight21.5 kg (47.4 lbs)21.0 kg (46.3 lbs) 33.5 kg (73.9 lbs)
Shipped Weight23.5 kg (51.8 lbs)23.0 kg (50.7 lbs)36.5 kg (80.5 lbs)
Packed Quantity111
(1) Average over stated bandwidth. Measured at 1 metre on axis in an anechoic chamber.
(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber.
A full range of measurements, performance data, and EaseTM Data can be downloaded from www.tannoy.com.
13. Technical Specications
Tannoy operates with a policy of continuous research and development. Product performance always will equal or exceed published specications. However, following introduction of new materials or
manufacturing methods, Tannoy reserves the right to alter specications without prior notice.
VX Series Operation Manual rev 3.1.0
20
18 mm (front) birch plywood,18 mm (front) birch plywood,18 mm (front) birch plywood,vented and internally bracedvented and internally bracedvented and internally braced
with custom colours on request.with custom colours on request.with custom colours on request.Powder coated perforated steel grillePowder coated perforated steel grillePowder coated perforated steel grilleAirnet cloth behindAirnet cloth behindAirnet cloth behind
landscape mounting),8 x M10 yoke bracket inserts,2 x Integrip carrying handles,Blanking plate for optional VTH pole mount,Fixings compatible with Powerdrivestyle brackets,4 x M6 inserts
H: 486 mm (19.1”),H: 486 mm (19.1”),H: 780 mm (30.7”),D: 360 mm (14.1”)D: 360 mm (14.1”)D: 360 mm (14.1”)
8 x M10 Flying inserts (portrait or landscape mounting),8 x M10 yoke bracket inserts,2 x Integrip carrying handles,Blanking plate for optional VTH pole mount,
TM
Fixings compatible with PowerdriveTMstyle brackets,4 x M6 inserts
8 x M10 Flying inserts (portrait or landscape mounting),8 x M10 yoke bracket inserts,2 x Integrip carrying handles,Blanking plate for optional VTH pole mount
ModelVX 15HPVX 15Q
Performance
Frequency Response (-3 dB)
Frequency Range (-10 dB) 158 Hz – 30` kHz58 Hz – 30 kHz
System Sensitivity (1 W @1 m)
Passive - Full Range99 dB (1 W = 2.83 V for 8 ohms)99 dB (1W = 2.83 V for 8 ohms)
Biamp (LF)100 dB 100 dB
Biamp (LF)106 dB108 dB
Dispersion (degrees conical)75 degrees conical75 degrees (H) x 40 degrees (V)
Driver Complement1 x 380 mm (15.00”) 1 x 380 mm (15.00”) PowerDual™
Directivity Factor (Q)9.7 (averaged 1 kHz to 8 kHz)12.0 (averaged 1 kHz to 8 kHz)
Directivity Index (DI)9.9 (averaged 1 kHz to 8 kHz)10.8 (averaged 1 kHz to 8 kHz)
Rated Ma ximum SPL (2)
Passive - Full Range125 dB (average) 131 dB (peak)125 dB (average) 131 dB (peak)
Biamp (LF )126 dB (average) 132 dB (peak)126 dB (average) 132 dB (peak)
Biamp (HF )125 dB (average) 131 dB (peak)127 dB (average) 132 dB (peak)
Power Handling
Passive - Full RangeAverage: 400 WAverage: 400 W
Biamp (LF )Average: 400 WAverage: 400 W
Biamp (HF )Average: 80 WAverage: 80 W
Recommended Amplier Power
Passive - Full Range800 W @ 8 ohms800 W @ 8 ohms
Biamp (LF )800 W @ 8 ohms800 W @ 8 ohms
Biamp (HF )160 W @ 8 ohms160 W @ 8 ohms
Nominal Impedance8 ohms8 ohms
Distortion
10% Full Power (10.2 V)2nd Harmonic 3rd Harmonic2nd Harmonic 3rd Harmonic
250 Hz1.0% 0.56%1.05% 0.10%
1 kHz1.4% 1.0%1.61% 1.02%
10 kHz3.9% 1.8%7.79% 1.15%
Distortion
10% Full Power (10.2 V)2nd Harmonic 3rd Harmonic2nd Harmonic 3rd Harmonic
250 Hz0.31% 0.45%0.30% 0.06%
1 kHz0.45% 0.79%0.58% 0.52%
10 kHz3.16% 0.32%2.32%0.13%
Product can be recongured forProduct can be recongured forbi-amped operation. Bi-ampbi-amped operation. Bi-ampsystem parameters in Operation Manualsystem parameters in Operation Manual
Programme: 800 WProgramme: 800 WPeak: 1600 WPeak: 1600 W
Programme: 800 WProgramme: 800 WPeak: 1600 WPeak: 1600 W
Programme: 160 WProgramme: 160 WPeak: 320 WPeak: 320 W
Construction
Enclosure57.82 litre, 18 mm birch plywood,57.82 litre, 18 mm birch plywood,
FinishTextured black or white paint, Textured black or white paint,
Connectors2 x speakON NL4MP and Barrier strip2 x speakON NL4MP and Barrier strip
Fittings8 x M10 Flying inserts (portrait or
Dimensions (H x W x D)W: 450 mm ( 17.7”), W: 450 mm (17.7”),
Net Weight26.5 kg (58.4 lbs)27.0 kg (59.5 lbs)
Shipped Weight29.5 kg (65.0 lbs)29.5 kg (65.0 lbs)
Packed Quantity11
(1) Average over stated bandwidth. Measured at 1 metre on axis in an anechoic chamber.
(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber.
A full range of measurements, performance data, and EaseTM Data can be downloaded from www.tannoy.com.
Tannoy operates with a policy of continuous research and development. Product performance always will equal or exceed published specications. However, following introduction of new materials or
manufacturing methods, Tannoy reserves the right to alter specications without prior notice.
vented and internally braced.vented and internally braced.
with custom colours on request.with custom colours on request.Powder coated perforated steel grillePowder coated perforated steel grilleAirnet cloth behindAirnet cloth behind
landscape mounting),8 x M10 yoke bracket inserts,2 x Integrip carrying handles,Blanking plate for optional VTH pole mount,Fixings compatible with Powerdrivestyle brackets,4 x M6 inserts
H: 590 mm (23.2”),H: 590 mm (23.2”),D: 420 mm (16.5”)D: 420 mm (16.5”)
8 x M10 Flying inserts (portrait or landscape mounting),8 x M10 yoke bracket inserts,2 x Integrip carrying handles,Blanking plate for optional VTH pole mount,
TM
Fixings compatible with PowerdriveTMstyle brackets,4 x M6 inserts
VX Series Operation Manual rev 3.1.0
21
13. Warranty
13. Warranty
No maintenance of the VX Series loudspeakers is necessary.
As part of the MUSIC Group, Tannoy is committed to providing the highest quality products, service and user
experience for our customers. One element of this commitment is our after sales support which now incorporates
our extended Limited Warranty. In the event of any concern that is not addressed by this extended Limited Warranty
we would ask you to contact us at care@music-group.com
For full warranty details including the extended Limited Warranty, please visit
http://www.music-group.com/warranty.aspx and register your purchase online at www.music-group.com
or www.tannoy.com
VX Series Operation Manual rev 3.1.0
22
14. Declaration of Conformity
14. Declaration of Conformity
(in accordance with ISO/IEC 1750-1)
Document No: CE-VX-2
We: Music Group Innovation SC Ltd
Rosehall Industrial Estate, Coatbridge, ML5 4TF, United Kingdom
In accordance with the following Directive(s):
2004/108/RC Electromagnetic Compatibility (EMC)
2011/65/EU Restriction of the use of certain hazardous substances (RoHS)
Hereby declare that:
Type of equipment Professional loudspeakers
Range name VX
Models VX 5.2, VX 6, VX 8, VX 8M, VX 8.2, VX 12, VX 12HP, VX 12Q, VX 12.2Q,
VX 15HP, VX 15Q
Is/are in conformity with the requirements of the following documents:
Ref. No Title Edition
BS EN 55103-1 Electromagnetic compatibility. Product family standard for audio,
video, audio-visual and entertainment lighting control apparatus 2009
for professional use. Emissions
BS EN 55103-2 Electromagnetic compatibility. Product family standard for audio,
video, audio-visual and entertainment lighting control apparatus 2009
for professional use. Immunity
Name: Philippe Robineau
Position: Director of Engineering
Done at: Coatbridge
Date: 27/04/2016
Director of Engineering
Tannoy
27 April 2016
VX Series Operation Manual rev 3.1.0
23
tannoypro.com
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing
methods will always equal or exceed the published specications. All specications are subject to change without notice.
Copyright (c) 2016 Music Group Innovation SC Ltd. All rights reserved.
6481 0592/270416
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.