Tannoy VQNET 40DF Specification Sheet

VQNET 40DF
Product Description
VQNET MH elements which are available in various patterns will integrate seamlessly with the VQNET DF enclosures to facilitate tight pack arrays; the compound angles on the enclosure avoid unsightly spaces between separate cabinets when arrayed horizontally VQNET MB or VS 15DR elements can be added to extend bandwidth and pattern control to lower frequencies.
Horn design involves balancing compromise…..until now.
Our unique approach in keeping what is effectively a Dual Concentric behind a single horn gives us many performance advantages. Performance of the VQNET 40DF in terms of accuracy & sound quality is second to none. The VQ horn design principles provide denitive and measurable advantages over multiple-horn and co-axial designs.
Each VQNET 40DF incorporates a unique driver technology to radiate a coherent single point source for superior dispersion control when coupled to a PSW™ (Point Source Waveguide). This advanced design aligns the acoustical centres of the transducers providing a single coherent wavefront emanating from the throat. The PSW™ waveguide achieves an optimum balance of extremely well controlled coverage, smooth frequency response, and natural sound character.
The modular approach of ampliers, processing, monitoring and drivers designed into each loudspeaker enables acoustic optimization for the speaker to perform as a unied whole.The intuitive setup software, integrated processing, tuning control, performance diagnostics and protection produces an easy to install and exceptionally high perform­ance networkable loudspeaker.
For outdoor applications, weather resistant enclosures which incorporate stainless steel hardware are available.
VNET™ Network
Each VQNET DF enclosure is fully VNET™ compliant. VNET™ supports free network topology so that the loudspeakers can be arranged in a daisy chain, linked in a star conguration or in any combination of both. Implementation of the network between nodes is via high quality rugged Neutrik Ethercon connectors, which are compatible with standard RJ45 plugs, and CAT5 cable. Each speaker has a unique address for auto-location on the network. System commissioning and ongoing network control, incorporating real time diagnostics of electronics and drive unit, are all managed by the exclusive VNET™ software package. Supplied with each unit, this intuitive Windows tool controls all critical install, commissioning and performance monitoring functions.
Features
• “PSW™ Waveguide” - Point source design (Patent applied for).
• Excellent Phase Coherence
• Perfect time alignment without the associated problems
of multi source interference
• Compact Dimensions
• Class leading directivity characteristics
• Extremely high sensitivity, therefore high SPL’s can be achieved with a very modest amount of amplier power
• Exceptional transient response
Applications
• Large Houses of Worship
• Large Corporate AV applications
• Stadiums & other Sports facilities
• Dance Clubs
• Live sound – concert halls, theatres, open-air venues
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
TECHNICAL SPECIFICATIONS
System VQNET 40DF
System Type 2-Way Mid/High - Point Source
Frequency Response (-3dB)
Frequency Range (-10dB)
(1)
400Hz - 23kHz
(1)
350Hz - 27kHz
Dispersion (-6dB) 40 degrees conical
Driver Complement Dual Concentric™
Compression driver loaded into
a single PSW™ Waveguide
Crossover 7kHz (DSP generated)
Recommended HighPass Filter @ 450Hz (DSP generated)
Directivity Factor (Q) 28.2 averaged 1kHz to 10kHz
Directivity Index (DI) 14.5 averaged 1kHz to 10kHz
Rated Maximum SPL
(2)
139dB (average) 145dB (peak)
Distortion 110dBSPL 2nd Harmonic 3rd Harmonic
500Hz 0.423 0.423 2kHz 0.821 0.021 5kHz 1.344 0.067
115dBSPL
500Hz 2.468 0.710 2kHz 1.458 0.041 5kHz 2.379 0.171
120dBSPL
500Hz 4.893 1.109 2kHz 2.534 0.094 5kHz 4.216 0.616
125dBSPL
500Hz 8.998 3.067 2kHz 4.208 0.350 5kHz 8.206 2.182
Electronics
Efciency >85% typically
Damping Factor 120 ref 8 Ohms Distortion <0.05% @ 1kHz -3dB output
(22kHz bandwidth) Input Impedance 5.6 kOhms unbalanced,
11.2 kOhms balanced
Output Power (Programme) 400W MF, 200W HF (limited to) Input Sensitivity 1.4V (+5.5dBu) System Type Dual channel Class D
DSP System
Comms Facilities Firmware updatable and selected
parameters editable Communications Serial - RS485 Proprietary message format
Dynamic Range 112dB(A) typical DSP 3rd generation SHARC Sampling Frequency 96kHz 24 bit A/D-D/A word length Format 1 IN - 2 OUT
PSU Specications
Input Connector Locking Neutrik Powercon Voltage Selection Automatic (115 / 230V, 45 - 65Hz) Type High current, high frequency switch mode
Efciency >90% typical
Input voltage 100V / 115V / 230V nominal +/-10% Mains fuse External Fuse type T10AT Other features Automatic soft start Current Draw 115V 230V Startup (inrush) 3.5A 1.9A idle 1.0A 0.56A Max 3.5A 1.7A
Construction
Enclosure 18mm (0.71”) birch plywood.
Internally braced.
Grille Powder coated perforated steel grille
Finish Textured black or white paint
(custom colours on request)
Connectors 1 x female XLR (input) 1 x male XLR (link) 1 x RJ45 (network in) 1x RJ45 (network link) 1 x Neutrik Powercon 1 x Neutrik Powercon (outlet)
Controls & Indicators LED on front of cabinet behind grill. (wink indicator for locating & assigning) Power LED (Blue) Signal LED (Green) Limit LED (Red) User DSP - defeat switch Power Switch
Fittings 2 x Recessed carrying handles 11 x M10 ying inserts
Dimensions 500 mm x 694mm x 515mm (19.69” x 27.32” x 20. ”)
Net Weight 32kg (70.4lbs)
Notes:
(1) Average over stated bandwidth. Measured at 3 metres on axis, then referred to 1 metre (2) Unweighted pink noise input, measured at 3 metres in an anechoic chamber, then
referred to 1 metre
A full range of measurements, performance data, CLF and Ease™ Data can be downloaded from www.tannoy.com
Full independent verication of published specications carried out by NWAA Labs, California can also be obtained from the downloads section of www.tannoy.com
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specications, which Tannoy reserves the right to alter without prior notice. Please verify the latest specications when dealing with critical applications.
28
Ordering Information
PART NUMBER MODEL NAME COLOUR PACKED QUANTITY 8001 5800 VQNET 40DF BLACK 1 8001 5801 VQNET 40DF WHITE 1
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
Frequency Response
Frequency Response
Horizontal Off-axis
-40
-30
-20
-10
0
10
10 100 1000 10000100000
0 deg
10 deg
20 deg
30 deg
40 deg
Frequency Response
Upper Vertical Off-axis
-40
-30
-20
-10
0
10
10 100 1000 10000100000
0 deg
10 deg
20 deg
30 deg
40 deg
PERFORMANCE MEASUREMENTS
ANECHOIC FREQUENCY RESPONSE
10
0
-10
-20
Level, (dB)Level, (dB)Level, (dB)
-30
-40
10 100 1000 10000100000
Frequency (Hz)
Frequency Response Horizontal Off-axis
Frequency Response
Complete
Frequency (Hz)
HORIZONTAL OFF AXIS RESPONSE
Frequency Response Upper Vertical Off-axis
Frequency (Hz)
UPPER VERTICAL OFF AXIS RESPONSE
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
Beamwidth vs Frequency
0
30
60
90
120
150
180
210
240
270
300
330
360
100 1000 10000
Horizontal Beamwidth (1/3 Octave)
Vertical Beamwidth (1/3 Octave)
Q vs Frequency
1
10
100
100 1000 10000
Frequency Response
Lower Vertical Off-axis
-40
-30
-20
-10
0
10
10 100 1000 10000100000
0 deg
10 deg
20 deg
30 deg
40 deg
PERFORMANCE MEASUREMENTS
Frequency Response Lower Vertical Off-axis
Level, (dB)Degrees
LOWER VERTICAL OFF AXIS RESPONSE
BEAMWIDTH
Frequency (Hz)
Beamwidth vs Frequency
Frequency (Hz)
Q vs Frequency
Q
Frequency (Hz)
Q VS FREQUENCY
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
DIRECTIVITY
DI vs Frequency
0
5
10
15
20
100 1000 10000
INDEX
VQNET 40DF
PERFORMANCE MEASUREMENTS
DI vs Frequency
DI
Frequency (Hz)
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
90
100 Hz
125 Hz
90
250 Hz
315 Hz
0
90
630 Hz
800 Hz
90
1.6 kHz
2 kHz
90
4 kHz
5 kHz
90
10 kHz
12.5 kHz
PERFORMANCE MEASUREMENTS POLAR PLOTS (1/3 OCTAVE)
270
300
300
300
300
330
330
330
330
-12
-24
-36
-48
-12
-24
100 Hz 125 Hz 160 Hz
0
0
0
30
200 Hz
330
30
330
0
0
0
30
250 Hz 315 Hz 400 Hz 500 Hz
30
-12
300
60
60
300
-24
60
60
-36
270
90
630 Hz 800 Hz
0
0
30
30
1 kHz
1.25 kHz
330
330
-48
0
0
0
30
30
1.6 kHz 2 kHz
2.5 kHz
3.15 kHz
90
-12
60
60
300
300
-24
60
60
270
270
300
300
330
330
-36
-48
-12
-24
-36
-48
270
90
4 kHz 5 kHz
0
0
0
30
30
6.3 kHz 8 kHz
60
60
330
330
300
300
270
90
-36
-48
-12
-24
-36
-48
90
10 kHz
12.5 kHz
0
0
0
30
16 kHz 20 kHz
30
60
60
90
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
90
100 Hz
125 Hz
90
250 Hz
315 Hz
90
630 Hz
800 Hz
90
1.6 kHz
2 kHz
4 kHz
5 kHz
90
10 kHz
12.5 kHz
16 kHz
PERFORMANCE MEASUREMENTS POLAR PLOTS (1/3 OCTAVE)
270
300
300
300
300
330
330
330
330
-12
-24
-36
-48
-12
-24
100 Hz 125 Hz 160 Hz
0
0
0
30
200 Hz
330
30
330
0
0
0
30
250 Hz 315 Hz 400 Hz 500 Hz
30
-12
60
60
300
300
-24
60
60
-36
270
90
270
630 Hz 800 Hz
0
0
0
30
1 kHz
1.25 kHz
330
30
330
-48
0
0
0
30
30
1.6 kHz 2 kHz
2.5 kHz
3.15 kHz
90
-12
60
60
300
300
-24
60
60
270
270
300
300
330
330
-12
-24
-36
-36
-48
-36
270
270
90
4 kHz 5 kHz
0
0
0
30
30
6.3 kHz 8 kHz
330
330
-48
0
0
0
30
30
10 kHz
12.5 kHz 16 kHz 20 kHz
90
-12
60
60
300
300
-24
60
60
-36
270
270
90
-48
90
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
VNET SOFTWARE
VNET™ SOFTWARE_
The loudspeakers are fully calibrated at the factory, avoiding the need to in put the correct speaker management settings or dynamics at the point of install. This frees the installer to concentrate instead on room measurement and system optimisation. System commissioning and ongoing venue network control, incorporating real time diagnostics of electronics and drive unit, are all managed by the exclusive VNET™ software package. Supplied with each unit, this intuitive Windows tool controls all of the critical install, commissioning and performance monitoring functions. A standard wireless LAN-to-serial bridge can be used to communicate with the network, allowing the commissioning engineer to sit in the auditorium communicating from a laptop on 802.11b
MONITORING & TELEMETRY FUNCTIONS_
During normal operation the speakers on the network will appear as minimised panels in the form of a status monitor icon (Monicon) on the computer screen. These are laid out to reect the physical layout of the speakers within the venue so that the user can monitor system status and component condition at a glance. The minimised panels can be expanded to reveal highly detailed information in real time:
• Input clip indicator
• Two output limiter bar graph meter
• Heat sink temperature bar graph meter
• Amplier clip indicators (HF & LF on full range units)
• Transducer Failure Indicators (HF & LF on full range units)
• Amplier protect status indicator
VNET™ Software Features
The on-screen control panel for each device in the network has a properties tab consisting of the following:
• Model Name is factory set with product model name
• Network Handle (read only) is a numerical value set at the time of manufacture to uniquely identify the device on the network
• Device Name is the specic user dened name, such as ‘Stage.Left’ or ‘Delay 1’
• Firmware Version (read only) is a numerical value of rmware version running in the device
• Conguration Name is the 12 character name the user can dene to describe the current settings (such as ‘Live Mode’)
• Current ‘Voice’ prole indication (read only) is a numerical value indicating the current speaker ‘voicing’ prole (the factory set equalization, crossover, & dynamics functions)
• Software le loader in VNET™ allows a future modication to the software to be uploaded, such as a ‘voicing’ change or revised control software with new features
• Record of any temperature or current shutdowns
• Record of the number of power cycles
• Rolling four day bar graphs recording amplier temperature and any dynamics applied
Signal Processing
• Gain Section: input gain fader with edit box (-30 to +15dB in 0.2dB steps)
• Input Mute: On, Off
• High-Pass Filter section: frequency spin / edit box and shape drop-down box
• Low-Pass Filter Section: frequency spin / edit box and shape drop-down box
• Equaliser Section: high resolution input EQ curve display
• Low Shelf Band: frequency spin / edit box, slope spin / edit box and boost-cut / edit box
• High Shelf Band: frequency spin / edit box, slope spin / edit box and boost-cut / edit box
• Parametric EQ Bands (x 8): frequency spin / edit box, slope spin / edit box and boost-cut / edit box
• Delay Section: delay spin / edit box (up to 180ms)
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
528.5
[20.81"]
90.0
[3.54"]
472.0
[18.58"]
694.0
[27.32"]
500.0
[19.69"]
465.0
[18.31"]
515.0
[20.28"]
DIMENSIONAL SKETCHES
INPUT PANEL
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
VQNET 100
VNET SC1 CONTROLLER
VQNET 100
VNET SC1 CONTROLLER
1
3
5 7 9
8
642
VQNET 100
VNET SC1 CONTROLLER
POWER INLET
The processor has a switch mode power supply that is capable of operating with a nominal mains voltage of 85V to 240V, 50/60Hz without re-configuration.
V
NET NETWORK PORTS
The network enabled V
NET SC1 controller features two network ports for
connection to any V
NETsystem.
COMMUNICATIONS PORT CONNECTOR
Tannoy V
NET SC1 processors may be controlled entirely from a PC
running V
NETsoftware using this RS232 serial port connector. This port
is also used for updating the firmware in the unit.
SECURE MODE SWITCH
A momentary button is fitted behind the rear panel, between the output XLRs and the RS232 port. When activated, this will disable all the front panel controls so they cannot affect the signal path, making the unit secure against tampering.
AUDIO OUTPUT CONNECTORS
The processed outputs are impedance balanced.
AUDIO INPUT CONNECTORS
All audio connections are fully balanced.
Rear Panel
VNET SC1 Controller
V
NET SC1 Controller (network enabled)
10
11
12
13
14
15
10 11
12
13
14
15
1
INPUT SIGNAL INDICATORS
A set of three pairs of LEDs indicate signal present, +4dBu and input clip for each channel.
STORE BUTTON
The unit has 45 preset locations.
RECALL BUTTON
To recall a preset, press the recall button and use parameter knob A to select the required preset.
CHANNEL SELECT BUTTONS
The currently selected input or output channel is shown in the top left corner of the display. Pressing the channel select buttons scrolls through the available inputs and outputs.
EDIT PARAMETER SELECT BUTTON
The name of the edit parameter page is displayed in the bottom left portion of the LCD.
DISPLAY SCREEN
Preset, channel, parameter and status information is shown on the 2x 24- character text display. In most screens the currently selected channel is displayed being the upper line and the edit parameter on the lower line.
PARAMETER EDIT ENCODERS
Three velocity sensitive parameter knobs are used to adjust parameters shown on the display. Up to three parameters at a time are displayed on the screen.
LIMITER INDICATOR
Two LEDs are provided for each output channel.
MUTE BUTTONS
Each output has a mute button and associated mute status LED.
Front Panel
3
5 7 9
8
642
POWER INLET
The processor has a switch mode power supply that is capable of operating with a nominal mains voltage of 85V to 240V, 50/60Hz without re-configuration.
V
NET NETWORK PORTS
The network enabled V
NET SC1 controller features two network ports for
connection to any V
NETsystem.
COMMUNICATIONS PORT CONNECTOR
Tannoy V
NET SC1 processors may be controlled entirely from a PC
running V
NETsoftware using this RS232 serial port connector. This port
is also used for updating the firmware in the unit.
SECURE MODE SWITCH
A momentary button is fitted behind the rear panel, between the output XLRs and the RS232 port. When activated, this will disable all the front panel controls so they cannot affect the signal path, making the unit secure against tampering.
AUDIO OUTPUT CONNECTORS
The processed outputs are impedance balanced.
AUDIO INPUT CONNECTORS
All audio connections are fully balanced.
Rear Panel
14
15
8
VNET SC1 CONTROLLER
VNET SC1 Controller
VNET SC1 Controller (network enabled)
1
10 11
3
5 7 9
12
642
13
14
8
15
1
INPUT SIGNAL INDICATORS
A set of three pairs of LEDs indicate signal present, +4dBu and input clip for each channel.
STORE BUTTON
2
The unit has 45 preset locations.
3
RECALL BUTTON
To recall a preset, press the recall button and use parameter knob A to select the required preset.
4
CHANNEL SELECT BUTTONS
The currently selected input or output channel is shown in the top left corner of the display. Pressing the channel select buttons scrolls through the available
inputs and outputs.
5
EDIT PARAMETER SELECT BUTTON
The name of the edit parameter page is displayed in the bottom left portion of the LCD.
DISPLAY SCREEN
6
Preset, channel, parameter and status information is shown on the 2x 24­character text display. In most screens the currently selected channel is displayed being the upper line and the edit parameter on the lower line.
7
PARAMETER EDIT ENCODERS
Three velocity sensitive parameter knobs are used to adjust parameters shown on the display. Up to three parameters at a time are displayed on the screen.
8
9
LIMITER INDICATOR
Two LEDs are provided for each output channel.
MUTE BUTTONS
Each output has a mute button and associated mute status LED.
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
10
POWER INLET
The processor has a switch mode power supply that is capable of operating with a nominal mains voltage of 85V to 240V, 50/60Hz withoutre-conguration.
11
VNET™ NETWORK PORTS
The network enabled VNET SC1 controller features two network ports for connection to any VNET™ system.
12
COMMUNICATIONS PORT CONNECTOR
Tannoy VNET SC1 processors may be controlled entirely from a PC running Vnet™ software using this RS232 serial port connector. This port is also used for updating the rmware in the unit.
13
SECURE MODE SWITCH
A momentary button is tted behind the rear panel, between the output XLRs and the RS232 port. When activated, this will disable all the front panel controls so they cannot affect the signal path, making the unit secure against tampering.
AUDIO OUTPUT CONNECTORS
14
The processed outputs are impedance balanced.
AUDIO INPUT CONNECTORS
15
All audio connections are fully balanced.
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
VQNET 100
OPTIONAL VNETTMUSB AND RS232 INTERFACE
The rack-mountable V
NET
TM
interface allows for communication between a VNETTMnetwork and computer.
If communicating with a non-networked SC1 direct communication via the PC & SC1 can be made with a standard serial lead, or USB-RS232 cable.
VQNET 100
OPTIONAL VNETTMUSB AND RS232 INTERFACE
The rack-mountable V
NET
TM
interface allows for communication between a VNETTMnetwork and computer.
If communicating with a non-networked SC1 direct communication via the PC & SC1 can be made with a standard serial lead, or USB-RS232 cable.
OPTIONAL V
NET
TM
ACCESSORY POWER SUPPLY
The PSU is only required when communication with a V
NET
TM
network is by RS232.
VQNET 100
OPTIONAL VNETTMUSB AND RS232 INTERFACE
The rack-mountable V
NET
TM
interface allows for communication between a VNETTMnetwork and computer.
If communicating with a non-networked SC1 direct communication via the PC & SC1 can be made with a standard serial lead, or USB-RS232 cable.
OPTIONAL V
NET
TM
ACCESSORY POWER SUPPLY
The PSU is only required when communication with a V
NET
TM
network is by RS232.
OPTIONAL RACK MOUNT KIT
This 1U bracket allows you to rack mount up to three V
NET
TM
interface accessories in a standard 19" equipment rack.
VNET SC1 CONTROLLER
OPTIONAL VNET
TM
USB AND RS232 INTERFACE
The rack-mountable VNETTM interface allows for communication between a VNETTM network and computer.
If communicating with a non-networked SC1 direct communication via the PC & SC1 can be made with a standard serial lead, or USB-RS232 cable.
OPTIONAL VNET
The PSU is only required when communication with a VNET
TM
ACCESSORY POWER SUPPLY
TM
network is by RS232.
OPTIONAL RACK MOUNT KIT
This 1U bracket allows you to rack mount up to three VNETTM interface accessories in a standard 19” equipment rack.
Ordering Information
PART NUMBER MODEL NAME COLOUR PACKED QUANTITY 8001 4450 VNETTM USB / RS 232 Interface BLACK 1 8001 4460 VNETTM Power Supply Interface BLACK 1 8001 4470 VNETTM Interface 1U rack mount kit BLACK 1
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
VQNET 40DF
Architectural specications
The loudspeaker shall consist of a Dual Concentric™ Compression driver with a 3.5” Midrange voice coil and a 2” High Frequency voice coil, both mounted in a common subsystem with a common 2” exit. This Dual Concentric™ compression driver shall be coupled to a PSW™ (Point Source Waveguide) constant directivity horn operating over the frequency range of 400Hz to 23kHz. The Mid/High frequency elements shall be driven by an integrated dual channel Class D amplier through a DSP generated crossover. The loudspeaker shall have user congurable DSP functionality.
A variable high pass lter shall be provided for use with subwoofers.
The loudspeaker shall be trapezoidal in shape.
Performance of the loudspeaker shall meet or exceed the following criteria: The Mid/High section shall be capable of producing a peak output of 141dB SPL on axis at 1 meter.
The dispersion of the loudspeaker shall be 40 degrees conical (-6dB). The enclosure shall be of birch plywood construction and internally braced. The enclosure shall be tted with two integral carrying handles, and eleven M10 inserts for ying hardware. The enclosure shall not exceed the following dimensions (H x W x D): 500 mm x 694mm x 515mm (19.69” x 27.32” x 20.5”)
The loudspeaker shall be the Tannoy... VQNET 40DF.
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: enquiries@tannoy.com Tannoy Middle East T: 00 971 (04) 4401208 E: enquiries@tannoy.com TC|Group International T: 00 45 8742 7000 E: info@tcgroup-international.com TC|Group Americas T: 00 1 (519) 745 1158 E: info@tcgroup-americas.com
Tannoy adopts a policy of continuous improvement and product specication is subject to change
VQNET 40DF // issue 1.01 // 22.11.11
Loading...