Tannoy Definition DC6i, Definition sub 15i, Definition DC8i, Definition DC12i, Definition sub 12i User Manual

INSTALL RANGE USER MANUAL
1
SAFETY INSTRUCTIONS
PRODUCT IDENTIFICATION
ACCESSORIES
PRODUCT DIMENSIONS
TECHNICAL SPECIFICATIONS
FULL RANGE models
SUBWOOFER models
WARRANTY STATEMENT
DECLARATION OF CONFORMITY
2
3
3
4
5-6
7-8
7
8
9
10
CONTENTS
2
SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. The user is responsible for fixing the hardware to the surface to ensure safe operation. The fixings must support the weight of the product – please consult the manual’s specification page for the appropriate weights. Please consult the relevant construction codes in your region for further information on suitable hardware fixing methods.
6. Some regional construction codes require the use of a secondary method of securing loudspeakers to surfaces to provide security of a back-up support. A secondary support line should be attached from the safety loop on the rear of the product to a source point on the wall. Please consult the relevant construction codes in your region.
7. Tannoy will not be held accountable for any damage caused by incorrect installation.
3
PRODUCT IDENTIFICATION
ACCESSORIES
WALL BRACKET
(only supplied with full range models)
FULL RANGE MODELS
Definition DC6i Definition DC8i Definition DC12i
SUBWOOFER MODELS
Definition sub 12i Definition sub 15i
4
INSTALLATION GUIDELINES
SURFACE MOUNTING THE LOUDSPEAKERS:
1. Lay the loudspeaker cable from the amplifier
to the location where you intend to surface mount the loudspeaker.
2. Terminate the loudspeaker cable with 4mm
connectors or spade connectors.
Connect the loudspeaker to the approipriate amplifer channel.
The positive terminal on the amplifier channel (marked + or coloured red) must be connected to the positive terminal on the loudspeaker (coloured red).
The negative terminal on the amplifier channel (marked - or coloured black) must be connected to the negative terminal on the loudspeaker (coloured black).
3. Attach the bracket plate to the wall using
appropriate fixings (Please consult the safety notes section of this user manual). See Fig 1.
4. Offer the loudspeaker up to the bracket.
The speaker can be installed either landscape or portrait.
5. Attach the loudspeaker to the bracket by
slotting the two bracket posts into the appropriate bracket insert points on the rear of the loudspeaker then lowering the loudspeaker down to allow it to lock onto the bracket.
See Fig 2.
Fig 1.
Fig 2.
5
PRODUCT DIMENSIONS
334.0
[13.15"]
250.0
[9.84"]
214.6
[8.45"]
394.0
[15.51"]
294.0
[11.57"]
215.0
[8.46"]
410.0
[16.14"]
550.0
[21.65"]
255.0
[10.04"]
DEFINITION DC6i
DEFINITION DC8i
DEFINITION DC12i
6
460.0
[18.11"]
430.0
[16.93"]
525.0
[20.67"]
435.0
[17.13"]
370.0
[14.57"]
355.0
[13.98"]
DEFINITION SUB12i
DEFINITION SUB15i
7
TECHNICAL SPECIFICATIONS FULL RANGE MODELS
SYSTEM DC6i DC8i DC12i
Frequency Response (-3dB)
(1)
85Hz - 35kHz 80Hz - 35kHz 67Hz - 25kHz
Frequency Range (-10dB)
(1)
70Hz - 45kHz 62Hz - 45kHz 50Hz - 38kHz
System Sensitivity (1W @1m)
(2)
90dB (1W = 2.83V for 8 ohms) 92dB (1W = 2.83V for 8 ohms) 97dB (1W = 2.83V for 8 ohms)
Dispersion (-6dB) 90 degrees conical 90 degrees conical 90 degrees conical
Directivity Factor (Q) 4.5 averaged 1kHz to 10kHz 5.7 averaged 1kHz to 10kHz 6.0 averaged 1kHz to 10kHz
Directivity Index (Di) 6.4 averaged 1kHz to 10kHz 7.0 averaged 1kHz to 10kHz 7.4 averaged 1kHz to 10kHz
Power Handling
(2)
Average 100W 130W 200W
Programme 200W 260W 400W
Peak (10ms) 400W 520W 800W
Recommended Amplifier Power 200W @ 8 Ohms 260W @ 8 Ohms 400W @ 8 Ohms
Rated Maximum SPL
(2)
Average 110dB 113dB 120dB
Peak 116dB 119dB 126dB
Nominal Impedance 8 Ohms 8 Ohms 8 Ohms
Driver Complement 1 x 150mm (6.00”) constant 1 x 200mm (8.00”) constant 1 x 300mm (12.00”) constant
directivity Dual Concentric™ directivity Dual Concentric™ directivity Dual Concentric™
Crossover Passive 1.6kHz with dynamic HF Passive 1.7kHz with dynamic HF Passive 1.4kHz with dynamic HF
protection protection protection
Distortion 10% Full Power (8.94V) 2nd Harmonic 3rd Harmonic (10.2V) 2nd Harmonic 3rd Harmonic (12.65V) 2nd Harmonic 3rd Harmonic
250Hz 2.40% 0.46% 0.40% 0.35% 0.53% 0.35%
1kHz 0.20% 0.53% 0.28% 0.66% 2.36% 1.88%
10kHz 1.19% 0.19% 1.50% 0.35% 2.68% 0.16%
Distortion 1% Full Power (2.83V) 2nd Harmonic 3rd Harmonic (3.22V) 2nd Harmonic 3rd Harmonic (4V) 2nd Harmonic 3rd Harmonic
250Hz 0.48% 0.37% 0.11% 0.15% 0.17% 0.09%
1kHz 0.01% 0.24% 0.12% 0.34% 0.52% 0.99%
10kHz 0.46% 0.07% 0.51% 0.17% 0.96% 0.02%
CONSTRUCTION
Enclosure MDF, vented and internally braced
Finish Textured black
2 x 4mm Gold Plated binding posts
Fittings 8 x M10 bracket inserts, 4 x wallplate keyhole fixings, allowing landscape or portrait mounting orientation, 1 x Wall plate
Dimensions (H x W x D) 334mm x 250mm x 214mm 394mm x 294mm x 215mm 550mm x 410mm x 255mm
(13.5” x 9.84” x 8.45”) (15.51” x 11.57” x 8.46”) (21.65” x 16.14” x 10.04”)
Weight 7kg (15.4lbs) 9.5kg (20.9 lbs) 20kg (44 lbs)
Notes
(1)
Average over stated bandwidth. Measured on axis in half space.
(2)
Long term power handling capacity as defined in EIA standard RS-426A.
A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com. Tannoy operates a policy of continuous research and development.
The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
8
TECHNICAL SPECIFICATIONS SUBWOOFER MODELS
SYSTEM SUB12i SUB15i
System Type Subwoofer - Direct Radiating Subwoofer - Direct Radiating
Frequency Response (-3dB)
(1)
48Hz 47Hz
Frequency Range (-10dB)
(1)
38Hz 36Hz
System Sensitivity (1W @1m)
(1)
94dB (1W = 2.83V for 8 ohms) 96dB (1W = 2.83V for 8 ohms)
Power Handling
(2)
Average 400W 600W
Programme 800W 1200W
Peak (10ms) 1600W 2400W
Recommended Amplifier Power 400 - 800W @ 8 Ohms 600 - 1200W @ 8 Ohms
Rated Maximum SPL
(2)
Average 120dB 124dB
Peak 126dB 130dB
Nominal Impedance 8 Ohms 8 Ohms
Driver Complement 1 x 300mm (12.00”) Bass driver 1 x 380mm (15.00”) Bass driver
Recommended Crossover 80Hz - 300Hz, 24dB/octave 70Hz - 300Hz, 24dB/octave
Recommended High-pass filter 40Hz, 24dB/octave 35Hz, 24dB/octave
Distortion 10% Full Power (17.9V) 2nd Harmonic 3rd Harmonic (21.9V) 2nd Harmonic 3rd Harmonic
40Hz 0.28% 2.26% 0.83% 0.68%
100Hz 0.29% 0.60% 0.23% 0.44%
Distortion 1% Full Power (5.9V) 2nd Harmonic 3rd Harmonic (6.9V) 2nd Harmonic 3rd Harmonic
40Hz 2.00% 0.15% 0.44% 0.28%
100Hz 0.009% 0.124% 0.15% 0.15%
CONSTRUCTION
Enclosure Front 36mm (1
3
/8") other panels 15mm (5/8") MDF internally braced.
Volume 38 litres 76 litres
Finish Black paint
Connectors 2 x 4mm Gold Plated binding posts
with screw terminals and "loop through" facility
Fittings 8 x M10 inserts, 4 x Rubber feet (not fitted)
Dimensions (H x W x D) 435mm x 370mm x 355mm 525mm x 460mm x 430mm
(17.1” x 14.6”x 14.0”) (20.7” x 18.1” x 16.9”)
Weight 21kg (46.3lbs) 30kg (66.1lbs)
Notes
(1)
Measured on axis in half space.
(2)
Unweighted pink noise input measured in an IEC baffle in an anechonic chamber. If the loudspeaker is installed in a false wall near a corner ( /2) an increase of 6dB in sensitivity and
maximum SPL can be realised.
A full range of measurements, performance data, and Ease™ Data can be downloaded from www.tannoy.com. Tannoy operates a policy of continuous research and development.
The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves the right to alter without prior notification.
9
WARRANTY STATEMENT
No maintenance of the Definition loudspeaker is necessary.
All of our products have been produced and tested with care and precision to give first-class service.
All passive components are guaranteed for a period of five years from the date of purchase from an authorised Tannoy dealer subject to the absence or evidence of misuse, overload, or accidental damage.
All active and electronic components are guaranteed for a period of one year from the date of purchase from an authorised Tannoy dealer subject to the absence of, or evidence of, misuse, overload or accidental damage.
If at any time during this warranty period the equipment proves to be defective for any reason other than accident, misuse, neglect, unauthorised modification or fair wear and tear, we will repair any such manufacturing defect or, at our option, replace it without charge for labour, parts or return carriage.
If you suspect a problem with a Tannoy product then, in the first instance, discuss it with your Tannoy dealer. If you require further assistance then we ask that you deal directly with your local Tannoy distributor. If you cannot locate your distributor please contact Customer Services, Tannoy Ltd at the address given below.
Customer Services, Tannoy Ltd., Rosehall Industrial Estate, Coatbridge, Strathclyde ML5 4TF, Scotland
Telephone: 01236 420199 (National)
+44 1236 420199 (International)
Fax: 01236 428230 (National)
+44 1236 428230 (International)
E-mail: enquiries@tannoy.com
DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION
Our policy commits us to incorporating improvements to our products through continuous research and development. Please confirm current specifications for critical applications with your supplier.
10
DECLARATION OF CONFORMITY
The following apparatus is manufactured in the UK at Tannoy Ltd of Rosehall Industrial Estate, Coatbridge, Scotland, ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended.
Details of the Apparatus: Tannoy Contractor Loudspeaker
Model Number: Definition
Associated Technical File: EMCi6 Applicable Standards: EN 50081-1 Emission
EN 50082-1 Immunity
Signed: Position: Director of Engineering (Professional)
Date: 07th Feb. 07
Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy North America T: 00 1 (519) 745 1158 E: inquiries@tannoyna.com Tannoy Deutschland T: 00 49 (180) 1111 881 E: info@tannoy.com Tannoy France T: 00 33 (0)1 7036 7473 E: ventes@tannoy.com
Tannoy adopts a policy of continuous improvement and product specification is subject to change.
REVISION DATE: Aug ‘07
6481 0500
Loading...