The Tannoy CMS601 DC is a full bandwidth; high power and high sensitivity ceiling monitor
system. The 165mm (6.50") Tannoy Dual ConcentricTM is a point source drive unit design
comprising a multi fibre paper pulp mid bass cone and a 25mm (1.00") ferrofluid cooled, titanium
dome HF unit with neodymium magnet system. The driver and passive frequency dividing
network are mounted in a vented, injection moulded, paintable front baffle manufactured from
UV/weather resistant UL94V-0 ABS material.
The mid-bass and tweeter sections of the Tannoy Dual ConcentricTM constant directivity driver
are coincidentally aligned to a true point source; ensuring a wide and controlled dispersion for
optimum coverage; this while avoiding the massive loss of energy in the vertical plane, at the
crossover frequency, inherent in two-way discreet designs. This high power and high sensitivity
design, with extended frequency response and very low distortion, is equipped with dynamic high
frequency protection.
This compact unit is specifically designed for applications requiring the combination of premium
sonic quality for music and speech reinforcement and exceptional reliability and intelligibility.
The CMS601 DC BM is equipped with a low insertion loss 60W line transformer easily
configurable to the following settings via front baffle mounted rotary tapping switch:
The CMS601 DC PI is supplied without a transformer. The 60W line transformer is available as
an optional accessory pack (7600 1658) for easy connection to the control switch circuit if the
product is to be used without a back can.
The recommended option for optimum performance and compliance with safety ratings is to use
the CMS601 PI Back Can (8001 4520) in which the transformer is pre-fitted.
Two CMS601 DC model versions and a separate back can are available to satisfy the vast
majority of installation application requirements:
CMS601 DC BM (Blind Mount) - supplied with an integral back can.
CMS601 DC PI (Pre-Install) - supplied without a back can.
CMS601 PI Back Can (Pre-wire back can) - use with the CMS601 DC PI.
The zinc plated steel back cans have an integrated, recessed termination box. The removable
locking connector has screw terminals for secure wire termination and "loop through" facility.
Strain relief is provided by a clamping mechanism for use with plenum rated cable or conduit.
Spring loaded self-aligning clamps make for quick and easy installation, while all models are also
supplied with two tile support rails and one C-ring included in the package.
A plaster (mud) ring is available as an optional accessory.
Features
• 165mm (6.50") point source Dual ConcentricTM driver
• High power & high sensitivity with extended frequency
response and very low distortion
• Wide, controlled constant directivity dispersion for
optimum coverage.
• Does not suffer from massive loss of energy in the
vertical plane at crossover caused by two way
discreet designs
• UV/weather resistant UL94V-0 ABS front baffle
• Blind Mount & Pre Install options
• Dynamic high frequency protection
• Easily accessible tapping switch on front baffle.
• Low insertion loss 60W line transformer
• Ferrofluid cooled neodymium HF
• Packaged with tile rails and C-ring for quick & easy
installation and simple stocking logistics
• Five year warranty
Applications
• Multi-zone foreground music & paging systems
• Boardrooms and offices
• Business music systems
• Airports, convention centres, hotels
• Reception and waiting rooms
• Houses of worship
• Retail outlets and shopping malls
• Lounges and bars
• Cruise ships
• Courtrooms
Tannoy United Kingdom
Tannoy North America
Tannoy Deutschland
Tannoy France
Tannoy adopts a policy of continuous improvement and product specification is subject to change
Transformer Taps (via front rotary switch)
70V60W / 30W / 15W / 7.5W / OFF &
100V60W / 30W / 15W / OFF &
Distortion
10% Full Power2nd Harmonic3rd Harmonic
250Hz1%0.32%
1kHz0.18%0.32%
10kHz1%0.18%
1% Full Power2nd Harmonic3rd Harmonic
250Hz0.25%0.25%
1kHz0.06%0.18%
10kHz0.45%0.14%
Crossover
(1) Average over stated bandwidth. Measured at 1 metre on axis.
(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber
(3) Long term power handling capacity as defined in EIA - 426B test
A full range of measurements, performance data, CLF and Ease™ Data can be
downloaded from www.tannoy.com
Full independent verification of published specifications carried out by NWAA Labs,
California can also be obtained from the downloads section of www.tannoy.com
Tannoy operates a policy of continuous research and development. The introduction
of new materials or manufacturing methods will always equal or exceed the
published specifications, which Tannoy reserves the right to alter without prior
notice. Please verify the latest specifications when dealing with critical applications.
(
5Hz - 30kHz
7
(1)
50Hz - 30kHz
(1)
46Hz - 30kHz
(2)
91dB (1W = 2.83V for 8 Ohms)
(2)
low impedance operation
low impedance operation
2kHz - 2nd order LF, 3rd order HF
(with dynamic HF protection)
Transducers
ow Frequency1 x 165mm (6.50") Dual Concentric™
L
igh Frequency1 x 25mm (1.00") titanium dome with
H
onstant directivity point source driver with
c
multi fibre paper pulp cone
eodymium magnet system
n
Physical
nclosure
E
Back canZinc plated steel
BaffleReflex loaded UL 94V-0 rated ABS
GrilleSteel, with weather resistant coating
Safety FeaturesSafety ring located at rear of enclosure
lamping DesignSecurity toggle clamp
C
Min / Max Clamping Range0.0mm (0.0") / 20.0mm (0.79")
Recommended Clamp Torque 1.5Nm
Back Can Options
Blind Mount (BM)Complete with fixed back can
re Install (PI)Separate back can for pre installation
P
Cable Entry OptionsCable clamp and squeeze connector for
Conduit Knockouts3 Sets of horizontal positions
ConnectorsRemovable locking connector with screw
Safety Agency Ratings
BM Hole Cutout Diameter253mm (9.96")
PI Hole Cutout Diameter253mm (9.96")
Dimensions
Bezel diameter280mm (11.02")
Front of ceiling to
rear of back can (BM)258mm (10.16")
Front of ceiling to
top of safety loop (BM)275.5mm (10.84")
Front of ceiling surface to
rear of speaker unit (PI)99.40mm (3.91")
Front of accessory back can
bezel to top of safety loop (PI) 168.50mm (6.60")
Net Weight (ea)
CMS601 DC BM7.45kg (16.42lbs)
CMS601 DC PI4.09kg (9.02lbs)
CMS601 DC PI back can3.685kg (8.12lbs)
Included AccessoriesC Ring, tile bridge, paint mask,
Optional AccessoriesPlaster (Mud) Ring
for load bearing safety bond
conduit up to 22mm
19 / 22 / 28mm (0.75" / 0.87" / 1.10")
terminals with "loop through" facility
(pending) UL-1480, UL-2043, CE
cutout template, grille
Ordering Information
PART NUMBERPACKED QUANTITYBAFFLE / GRILLE COLOURMODEL NAME
8001 4530CMS601 DC BMWhite / paintable2
8001 4540CMS601 DC PIWhite / paintable2
8001 4181CMS601 DC Plaster (Mud) RingZinc plated steel10
8001 4590CMS601 DC PI 8ohm back canZinc plated steel1
7600 1658CMS601 DC 60W transformer kit 8 ohmN/A1
Tannoy United Kingdom
Tannoy North America
Tannoy Deutschland
Tannoy France
Tannoy adopts a policy of continuous improvement and product specification is subject to change
he Ceiling Monitor System shall consist of a 165mm (6.50") full range, point source, constant directivity Dual ConcentricTM transducer and passive fre-
T
uency dividing network mounted in a vented, injection moulded, paintable front baffle in UL94V-0 ABS material.
q
The back can in both PI (pre-install) & BM (blind-mount variants) shall be constructed of zinc plated steel. A recessed termination box shall be integrated with
the back can, a removable locking connector with screw terminals for secure wire termination with "loop through" facility shall be provided. Strain relief will be
provided by a clamping mechanism for use with plenum rated cable or conduit.
For prewiring the PI (pre-install) back can is provided with conduit knockouts (19mm / 22mm / 28mm, 0.75" / 0.87" / 1.14"). A safety ring is located on the
rear of the back can for a load bearing safety bond.
Performance of the Ceiling Monitor System shall meet or exceed the following criteria: The system shall have a conical coverage pattern of 111degrees
(1kHz to 6kHz). Frequency response measured on axis shall be 50Hz - 30kHz (-10dB from rated sensitivity, measured in an IEC baffle in an anechoic
hamber) with no equalization. Sensitivity shall be 91dB (1W @ 1m). Long term power handling capacity as defined in EIA-426B test shall be 80W,
c
ecommended amplifier power 160W. Dynamic high frequency protection is provided for occasional overpowering. The nominal system impedance shall be
r
8 Ohms (in low impedance setting).
The Ceiling Monitor System shall be equipped with a 60W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 60,
30, 15, 7.5* Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance
settings. A weather resistant perforated steel grille covers the transducer and switch.
Two support rails and one C-Ring shall be included with the ceiling monitor system.
Bezel diameter 280mm (11.02")
BM Front of ceiling to rear of back can 258mm (10.16"), Front of ceiling to top of safety loop 275.5mm (10.84")
PIFront of ceiling surface to rear of speaker unit 99.40mm (3.91"), Front of accessory back can bezel to top of safety loop 168.50mm (6.60")