Tanita innerScan Dual RD-545 Quick Start Manual

EU Representative TANITA Europe B.V.
EU Representative TANITA Europe B.V.
Mumbai 400 059 India
DualFrequencyBodyCompositionMonitorRD-545
QuickStartGuide
The product design and specifications may be changed at any time without prior notice.The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such mark by Tanita
Android is a trademark of Google Inc.
Specifications
RD-545
Weight Capacity
200kg/440lb/31st6lb
Weight Increments
0-100kg/0.05kg 100kg-200kg/0.1kg 0-200lb/0.1lb 200-440lb/0.2lb 0-15st0lb/0.1lb 15st0lb-31st6lb/0.2lb
Personal Data
4 memories
Power Supply
4×AA Alkaline batteries(included)
Power Consumption
120mA Maximum
Measuring Current
50kHz, 6.25kHz, 100µA
Front
Battery Cover
Up / Recall Button
Weight-Only / O Button
SET / Communication Button
Down / Item Select Button
Features and Functions
Back
AccessoriesLocation Code Quick Start Guide
AA-Size Batteries (4
)
Battery Box 
Not allowed to mix batteries with consumer wastes!
As consumer you are legally bound to return used or discharged batteries. You can deposit your old batteries at the public collecting points in your town, or wherever the corresponding batteries are sold and specically marked collecting boxes have been set up. In case of scrapping the apparatus, the batteries should be removed from it and deposited at the collecting points as well.
©2017 TANITA Corporation RD-5457611(0)-1601FA
See the instruction manual for details. www.tanita.eu/help-guides
Applicable Age Range
Body Mass Index
5-99 years old
5-99 years old
Total & Segmental Body Fat (%)
18-99 years old
Total & Segmental Muscle Mass
18-99 years old
Physique Rating
18-99 years old
Bone Mass
18-99 years old
Vesceral Fat Level
18-99 years old
Basal Metabolic Rate
18-99 years old
Metabolic Age
18-99 years old
Body Water (%)
18-99 years old
Total & Segmental Muscle Quality
Disposal
This is an electronic device. Please dispose of it as an electronic device, not as general household waste. Please follow the regulations in your local region when disposing of this device.
Do not attempt to disassemble the monitor. Do not modify this equipment in any way. Do not wash the monitor in water. Do not submerge this monitor in water.
Doing so may damage the monitor or cause it to malfunction.
Keep away from water.
Doing so may damage the monitor or cause it to malfunction.
Do not use or store this monitor in the following locations.
·Locations that are exposed to direct sunlight, near to heaters, or exposed directly to air from air conditioning units, etc.
·Locations where there are severe temperature changes or a large amount of vibration.
·Locations with high levels of humidity or moisture
Do not use boiling water, benzene, thinner or alcohol, etc. to clean the monitor.
If the monitor becomes dirty, soak a soft cloth in water or neutral household detergent, wring it out thoroughly and wipe the monitor clean, then use a dry cloth to wipe the monitor dry.
Another person should assist persons with disabilities who may not be able to take a measurement alone.
Be sure to insert the batteries with the polarities (+, -) in the correct position.
If the batteries are incorrectly inserted, battery fluid may leak and damage the floor. (If you do not intend to use this monitor for a long period of time, it is advisable to remove the batteries before storage.)
Do not step on the monitor when your body is wet (immediately after a shower or bath, etc.)
Be sure to thoroughly dry your body and feet before using the monitor. Failure to do so may cause you to slip or fall, resulting in injury. Also, the monitor cannot take accurate measurements if your body or feet are wet.
Place the monitor on a hard, flat surface where there is minimal vibration to ensure safe and accurate measurement.
Do not use the monitor near other products such as microwave ovens that emit electromagnetic waves.
Doing so may cause the monitor to malfunction, preventing accurate measurements.
Avoid excessive impact or vibration to the monitor.
Doing so may damage the monitor or cause it to malfunction,or may cause setting to be erased.
Always…
SET Button O Button
Insert the batteries Set your location code
Getting Accurate Readings
Preparations before Use
To ensure accuracy, readings should be taken without clothing and under consistent conditions of hydration. If you do not undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping on the measuring platform. Be sure that your heels are correctly aligned with the electrodes on the measuring platform. Don’t worry if your feet appear too large for the unit accurate readings can still be obtained if your toes overhang the platform. It is best to take readings at the same time of day. Try to wait about two hours after rising, eating, or hard exercise before taking measurements. While readings taken under other conditions may not have the same absolute values, they are accurate for determining the percentage of change as long as the readings are taken in a consistent manner. To monitor progress, compare weight and body fat percentage taken under the same conditions over a period of time.
An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent or you are in a sitting position.
Different locations across the world have different gravitational pulls. These differences affect the accuracy of the weight measurement. You can obtain the most accurate weight readings by selecting the correct gravity setting on the scale according to your geographical location.
1.When the power is turned off, press any of the     buttons to start configuring the settings.
2.Refer to the map enclosed, and press the   buttons to select your location code.
3.Press the button to enter and save the setting.
Please note that the included batteries from factory may have decreased energy levels over time.
Note
Up ButtonDown Button
Ball-of-foot Electrodes
Grip
Illumination
Control Panel
Heel Electrodes
Display Screen
Weight
For Your Safety
Prohibited
Warning
Caution
This mark indicates actions that are prohibited.
This mark indicates instructions that must always be followed.
This section explains precautionary measures to be taken to avoid injury to the users of this device and others, and to prevent damage to property. Please familiarise yourself with this information to ensure safe operation of this equipment.
Failure to follow instructions highlighted with this mark could result in death or severe injury.
Prohibited
Warning
Do not step on the edge of the platform.Do not jump onto, or on the monitor.
Doing so may cause you to fall or slip, resulting in serious injury.
This monitor must not be used by people with pacemakers or other medical implants.
This monitor passes a weak electrical current through the body which could interfere with and cause the malfunction of electrical medical implants, resulting in serious harm to the user.
Do not place this monitor on a slippery surface such as a wet floor.
Doing so may cause you to fall or slip, resulting in serious injury. It may also cause water to get inside the monitor resulting in damage to internal components.
Interpretation of measurements (e.g. evaluation of measurements and formulation of exercise programmes based on the measurements) must be performed by a professional.
Implementing weight loss measures and exercise programmes based on self-analysis could be harmful to your health. Always follow the advice of a qualified professional.
Failure to follow instructions highlighted with this mark could result in injury or damage to property.
Do not use old batteries together with new batteries, or a mix of different types of batteries at the same time.
Doing so may cause battery fluid to leak or the batteries to become excessively hot and rupture, resulting in damage to the monitor or injury.
Do not use rechargeable batteries.
Do not insert your fingers into gaps or holes.
Doing so may result in injury.
Do not stand on the display screen or control panel.
This monitor is not intended for professional use including hospitals, medical or fitness facilities. It is not equipped with the components required for heavy usage. Using the monitor in a professional location will invalidate the warranty.
This monitor is intended for home use only.
If the cable does not automatically return into the monitor unit, untwist the cable, pull it out approximately 20cm and then try returning it again.
Do not pull out the cable unless using the monitor for measurement, as doing so may damage the monitor. Do not pull out the cable beyond the red mark. Do not pull the cable too forcefully.
Never allow an infant or small child to carry the monitor.
Store out of reach of small children.
The child may drop the monitor, resulting in injury.
Small children may become caught up in the cables, resulting in injury.
Caution
Turn the Bluetooth setting on, and use the URL to download the My Tanita app.
Select "Measurement" in the app, and then follow the instructions in the app.
Measurement data is automatically sent to the smartphone.
Step onto the monitor to take measurements. Data from a maximum of 10 measurements is saved in the monitor.
Saved data is sent to the smartphone together with other new measurements next time the phone is connected to the monitor.
From the next time, just step onto the monitor to take measurements. Data from a maximum of 10 measurements is saved in the monitor.
Launch the app. You need to register as a member to use the My Tanita app. After registering, login with your registered details.
Tap "Sync / Pair "device button. Follow the instructions in the app.
Select "Input Data", then select "Input from BCM". Select "RD-545" in the next screen.
STEP
1
www.tanita.eu
21
1
3 4
21
Connecting to Your Smartphone
STEP
2
Taking Measurements
If you do not have your smartphone when taking measurements
If you do not have your smartphone when registering personal data
Measurement Results
Metabolic Age Total Body Water (%) BMIBasal Metabolic Rating
Setting the Date and Time
Registering Personal Data
Registering your Body Composition
Body Fat (%)*
Visceral Fat
Muscle Mass* Muscle Quality Score*
Bone Mass
Press  .
2
Use   and  to set the date and time.
1
Press  .
2
Use   and  to register the personal data number (1 - 4), date of birth, sex (male/female/) and height.
3
Press  or  to turn the pulse measurement function ON or OFF. Press   to enter the setting.
See the instruction manual for details. http://tanita.eu/help-guides
* Press   to display the measurement results for individual parts (left arm, right arm, left leg, right leg, trunk). * There is no muscle quality score for the trunk.
The screen displays and instructions may differ depending on the app specifications.
Saved data is sent to the smartphone together with new measurements the next time the smartphone is connected to the monitor when taking measurements.
SET Button O Button
When 0.00kg appears in the display, hold the operating section and stand on the measuring platform correctly with bare feet. Please remain as still as possible during measurement.
Holding the operating section or removing the operating section and placing it on the floor before 0.00kg appears in the display may prevent the meter from measuring correctly.
Note
Up ButtonDown Button
Loading...