Tandberg Data BAKSTOR Administration Manual

Page 1
INSTALLATION
AND
ADMINISTRATION
MANUAL
TANDBERG DATA ASA
P.O. Box 134 Kjelsås N-0411 OSLO, NORWAY Phone + 47 22 18 90 90 Telefax + 47 22 18 95 50
© Tandberg Data ASA
Rev. 03
September
2005
Page 2
All rights reserved. No part of this publication may be reproduced, trans
mitted, transcribed, stored in
a retrieval system, or translated into any language or computer language, in any form or by any
means, electronic,
mechanical, magnetic, optical, chemical, manual or otherwise, without the prior
written consent of Tandberg Data ASA.
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules and based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI)
. These limits are designed to provide the reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy. If the device is not installed and used in accordance with the instructions, the radio frequency energy may cause harmful interference to radio communications. However, there is no guarantee that in
terference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interfere
nce by one or more of the following measures. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Disclaimer
Tandberg Data makes no representations or warranties with res
pect to the contents hereof and
specifically disclaims any implied warranties of merchantability or fitness for an
y particular purpose.
Furthermore, Tandberg Data reserves the right to revise this publication and to make changes from
time to time in the content hereof without oblig
ation to notify any person of such revisions or changes.
Lithium Battery Notice
Do n
ot open battery, dispose of by burning, heat above 100° C (212° F), expose contents to water,
recharge, put in backwards, or use in combination with used batteries or other battery types. Mishandling of a lithium battery may result in personal injury hazar
d do to leaked chemicals, fire, or
explosion.
Page 3
BakStor Installation and Administration Manual
Table of Contents
1.
Introduction................................................................................................
5
1.1
Important Safety Instr
uctions...........................................................
6
1.2
Technical Specifications...................................................................
8
1.2.1
Power ratings.....................................................................
8
1.2.2
Physical Dimensions..........................................................
8
1.2.3
Agency Certifications.........................................................
8
1.2.4
Environmental....................................................................
8
1.2.5
Acoustic Noise....................................................................
8
1.3
RAID
9
1.4 Backup 9
1.5
User-Friendly Configuration............................................................
9
1.6
Fault Tolerance.................................................................................
9
1.6.1
Disk Drive ..........................................................................
9
1.6.2
Connection .........................................................................
9
1.7
Additional Features and Options....................................................10
1.8
Notes on this manual......................................................................10
2
Before Connecting the BakStor...............................................................13
2.1
Unpacking.......................................................................................13
2.2
Connectors on the BakStor 1000 (1U-Unit)...................................13
2.2.1
Power ............................................................................... 14
2.2.2
Ethernet 0.........................................................................14
2.2.3
Ethernet 1.........................................................................14
2.3
Connectors on the BakStor 2000 (2U-Unit)...................................14
2.3.1
Power ............................................................................... 14
2.3.2 E
thernet 0.........................................................................15
2.3.3
Ethernet 5.........................................................................15
2.3.4
Ethernet 1
- 4....................................................................15
2.4
Mou
nting the BakStor ....................................................................15
2.5
External Tape Device.....................................................................16
3
Configuration............................................................................................19
3.1
Install Disk Drive ...........................................................................19
3.2
RAID Setup....................................................................................19
3.3
Network Setup................................................................................19
3.4 Power 19
3.5
Connecting to the BakStor for the First Time................................20
3.6
Shutting Down the BakStor............................................................21
3.7
Setting Up a RAID .........................................................................21
3.8
Activating the RAID Storage.........................................................21
3.9
Choosing Slices or a Virt
ual Tape..................................................22
3.10
Creating Slices................................................................................22
4 Advanced Configuration..........................................................................25
4.1
Choosing a RAID Level................................................................
.25
4.1.1
RAID-0 (Disk Striping)..................................................... 25
4.1.2
RAID
-1 (Disk Mirroring) ................................................. 26
4.1.3
RAID-5 (Multiple Block Striping with Interspersed Parity)
..........................................................................................26
Page 4
Tandberg Data
BakStor
Installation and Administration Manual
4.1.4
Shared hot spare drive .....................................................27
4.2
Creating a RAID.............................................................................28
4.2.1
Activate newly build RAID...............................................30
4.3
RAID Failure..................................................................................30
4.3.1
Repairing a RAID.............................................................31
4.3.2
Deleting a RAID...............................................................34
4.4
Snapshots........................................................................................35
4.4.1
Creating Instant Snapshots ..............................................35
4.4.2
Scheduling Snapshots.......................................................36
4.5
Creating an AiiR Process ...............................................................38
4.5.1
Starting an AiiR Process..................................................39
4.6
Adding Secure Authentication (CHAPs) .......................................40
4.6.1
Setting a Password for the BakStor..................................40
4.6.2
Setting a Password for an Individual Slice...................... 41
5
Connecting and Using Extern
al Units....................................................43
5.1
Connecting a BakStor Expansion Unit...........................................43
5.1.1
Preparing the BakStor Master Unit................................
.43
5.1.2
Connecting the BakStor Expansion Unit..........................43
5.1.3
Detecting and Configuring the BakStor Expansion Unit
.44
5.1.4
Activating RAID Sets on BakStor Expansion Unit........... 44
5.1.5
Powering down a BakStor Expansion Unit......................45
5.1.6
Fai
lover Ethernet for Expansion Unit..............................45
5.2
Using an External Tape Device......................................................48
5.2.1
Connecting and Configuring a Stand-Alone Tape De
vice48
5.2.2
Formats for moving data to a physical tape ....................48
5.2.3
Selecting encryption method for moving data to physical
tape...................................................................................49
5.2.4
Checking contents of a physical tape...............................50
5.2.5
Defining a backup policy..................................................50
5.3
Scheduling a Backup......................................................................52
5.4
Restoring from a Physical Tape .....................................................53
5.4.1
Restoring data to a slice from a Physic
al Tape ...............53
5.4.2
Restoring a slice from a Physical tape.............................54
6
Configuration Options.............................................................................55
6.1
Global Network Configuration.......................................................55
6.2
IP Configuration.............................................................................56
6.3
System Configuration.....................................................................57
6.3.1
Setting a Password for the Administrator........................57
6.3.2
Setting the System Time....................................................57
6.3.3
Setting an Email Address for Notifications......................57
6.4
iSCSI Configuration.......................................................................58
6.4.1
Starting / Restarting the iSCSI Service ............................58
6.4.2
Stopping the iSCSI Service...............................................58
6.4.3
Configuring iSCSI iSNS server ........................................58
7
Maintenance..............................................................................................59
7.1
Update Code...................................................................................59
8
Appendix ...................................................................................................61
8.1
iSCSI Initiator Installation..............................................................61
Page 5
Tandberg Data
BakStor User manual
8.2
Importing a Slice to a Windows iSCSI Initiator.............................62
8.3
Using a Firewall .............................................................................64
Page 6
Page 7
BakStor Installation
and Administration Manual 5
1. Introduction
The BakStor products are specifically designed to provide backup and Data Security to any workplace equipped with an Ethernet network. It is totally independent of any host system's operating system. The functions are performed by an internal CPU coupled with high-
speed system memory and firmware. In effect, it endows the workplace network with a high-speed and fault
-tolerant Backup and Data security storage operation using industry leading technologies such as iSCSI (Internet Small Computer System Interface), RAID (Redundant Array of Inexpensive Disks), Snapshot and AiiR (Automated Internal Intelligent Replication) technology.
BakStor products have comprehensive management that incorporates today’s industry demands such as RAID, D2D (Disk To Disk) and Tape Backup. Hot swapping of a failed drive followed with background rebuilding of data. Spare drives can be dedicated, which is ready to restore data from any failed drive in the system. What’s remarkable is all these failure r
ecovery
procedures are transparent to the workplace. Storage capacity can be maintained or expanded by adding or replacing disk drives without
powering down the system. Fault tolerance can also be instructed to the workplace using network AFT, ALB and 802
.3ad
industry leading network topologies. BakStor products have been designed with ease of integration and maintenance in mind. All
major features are described in the following chapter.
Page 8
Tandberg Data
6
BakStor Installation and Administration Manual
1.1
Important Safety Instructions
General Precautions and Electrical C
onsiderations.
Thank you for investing into Tandberg technology. We appreciate that your time is important, however we encourage you to read the following safety instructions before setting up your system
Follow all warnings and instructions. Save these in
structions for future reference. Use of an uninterruptible power supply is strongly recommended. Do not set up or use this device near water. Electrical shock and damage may occur if
water shorts out high voltage parts.
Do not block the enclosure vents as
this could lead to the installed components
overheating. Ensure rack subsystem has proper ventilation. Never set enclosure on a heat source. Never insert any foreign objects into the enclosure slots. Fire, electrical shock, and
damage may occur if such obj
ects short out high voltage parts. Operate the device only using the correct type of power source. Plug the power cords into a properly grounded electrical outlet to prevent electric shock.
Do not use adapter plugs or disconnect ground prong. If you use an
extension cord with this enclosure, use a 3-wire extension cord and ensure that the extension cord's ampere rating is sufficient to handle the load of all of the equipment plugged into it.
In the event of a disk drive failure or the installation of a new
drive, replace only with an
approved disk drive.
Turn OFF both the power switches on the rear of enclosure and unplug all power cords
from electrical outlets before removing covers.
Prevent static electricity from permanently damaging the electronic compon
ents.
Handle components and printed circuit boards with care. Avoid touching components and
contacts on cards.
DO NOT attempt to service this device yourself. Refer all servicing to qualified service
personnel.
Contact service personnel if:
A power cable
or plug is damaged. The enclosure has been exposed to water or liquid has been spilled into it. The enclosure has been dropped, or the cabinet is damaged. The unit does not operate normally when the operating instructions are followed.
Page 9
Tandberg Data
BakStor Installation and Administration Manual
7
Maintenance Turn
off the enclosure and unplug it from the electrical source before cleaning. Never apply liquid or aerosol cleaners directly to the enclosure. If the enclosure gets wet, unplug all system power cables and contact technical support for assistance.
Page 10
Tandberg Data
8
BakStor Installation and Administration Manual
1.2
Technical Specifications
1.2.1 Power ratings
Bakstor 1000 Series: 100-
240V, 47-63Hz, 2-1A
Bakstor 2000 Series: 100-
240V, 47-63Hz, 3-1.5A
1.2.2 Physical Dimensions
Bakstor 1000 Series: Width x Depth x Height:
483mm x 508mm x 45 mm (19" x 20" x 1.75")
Weight:
19.3kg
(42.7 lbs)
Bakstor 2000 Series: Width x Depth x Height:
483mm x 508mm x 89 mm (19" x 20" x 3.5")
Weight:
22.7kg (50.6 lbs)
1.2.3 Agency Certifications
TüV, UL, cUL, CE, C-tick, VCCI, FCC Class B
1.2.4 Environmental
Operating temperature:
10 degC to 29 d
egC (50 degF to 84 degF)
Humidity:
15% to 80% RH non-condensing
Operating altitude:
0m to 2438m (0 ft to 8000ft)
1.2.5 Acoustic Noise
Sound power level (dBLwA) : 68 Sound pressure level (dBLpA) : 60
Page 11
Tandberg Data
BakStor Installation and Administration Manual
9
1.3
RAID
Redundant Array of Inexpensive Disks or RAID, offers the following advantages: Performance, Availability and Capacity. Choosing the right RAID level allows for the desired combination of performance, availability, capacity and fault tolerance. The BakStor supports RAID levels 0, 1, 5, 1 + Hot Spare, 5 + Hot Spare. Fault tolerance features such as allocated hot spare drive enables a high tolerance level of RAID disk drive security and safety.
1.4
Backup
The BakStor utilizes technologies that allow features such a Snapshot, B2D (backup to disk) and ‘AiiR
’ technologies. There is an external port option to allow backup to an external tape device
or tape library.
1.5
User-Friendly Configuration
There is a comprehensive menu system that can be accessed via a standard browser using the http protocol. The menu system allows all areas of the BakStor to be controlled, changed and managed.
1.6
Fault Tolerance
1.6.1 Disk Drive
The BakStor has comprehensive drive failure management that allows automatic RAID rebuilding (RAID levels 1 and 5 only) using an allocated hot spare drive in the case of a disk drive failure. The RAID automatically disconnects the failed drive and rebuilds data onto the hot spare drive, which in turn replaces the defective drive after the rebuild process. A failed disk drive in a RAID can be replaced manual
ly followed by a background rebuilding of data.
1.6.2 Connection
The BakStor uses standard 1-gigabit Ethernet connections. Using the second Ethernet connection the network can be configured in three different fault tolerant options:
AFT - Adapter Fault Tolerance
. Only one network adapter is active at a time. On any failure of primary connection (cable, adapter, port) a secondary adapter automatically takes over.
ALB - Adaptive Load Balancing. Transmission load is shared among all adapters
802.3ad -Intel Link Agg
regation. All adapters simultaneously receive and transmit data.
Includes fault tolerance and load balancing. Requires a switch that supports Intel Link
-
Aggregation, Cisco Fast Ether Channel or static 802.3ad.
Page 12
Tandberg Data
10
BakStor Installation and Administration Manual
1.7
Additional Features and Options
Remote monitor
ing / administration Expanding volume space by means of a BakStor Expansion Unit Email notification Adapter fault tolerance / Load balancing / Intel link aggregation Remote upgrade functionality
1.8
Notes on this manual
This manual contains screenshots and in
structions on how to use various menu items.
Your BakStor may have an interface that is slightly different that the screenshots shown in this manual and the structure of the menu system as well as some of the menu items might be slightly different.
However
, the functionality of the BakStor will be the same.
Page 13
Tandberg Data
BakStor Installation and Administration Manual
11
This Page Intentionally Left Blank
Page 14
Page 15
BakStor Installation
and Administration Manual
13
2
Before Connecting the BakStor
2.1
Unpacking
Although every effort has been taken to ensure the quality of packaging please ensure that there is no damage to the out
er and inner packaging.
Adhering to standard anti-static procedures is highly recommended.
Caution!
To reduce the risk of injury from electric shock, remove all power cords to completely
disconnect power from the unit.
To reduce the risk of personal injury
or damage to the equipment, observe local
occupational health and safety requirements and guidelines for manual material handling.
VORSICHT!
Um Verletzungen durch Stromschläge zu vermeiden, müssen Sie alle Netzkabel abziehen,
damit die Stromzufuhr zum Sy
stem vollständig unterbrochen ist.
Um Verletzungen oder eine Beschädigung des Geräts zu vermeiden, beachten Sie die vor
Ort geltenden Arbeitsschutz- und Sicherheitsrichtlinien für den manuellen Umgang mit
schweren Gegenständen.
2.2
Connectors on the BakStor 1
000 (1U-Unit)
The BakStor is capable of being rack mounted or deployed as a desktop product. In the case of rack mounting rack mount brackets should be fitted before deploying the BakStor.
If an external tape device or tape library is to be connected the
appropriate cables will have to be
connected as well. To set up the BakStor there are up to three connections that need to be connected. If an external
tape device or tape library is to be connected the appropriate cables will have to be connected in addit
ion.
Figure
2-1
Connectors on the BakStor 1000
Function
Connector
Function
Connector
Power
J
Ethernet 0
F
External tape device
K
Ethernet 1
G
Page 16
Tandberg Data
14
BakStor Installation and Administration Manual
2.2.1 Power
Connect a single 3-pin 100/240V AC power cable to p
osition J. (
Figure
2-1)
2.2.2 Ethernet 0
Connect the BakStor to the existing LAN by plugging an Ethernet cable to position F. (
Figure
2-1) The Ethernet connection can be a 10/100/1000 Mbps to match capabilities of the
connecting
LAN.
2.2.3 Ethernet 1
The BakStor also has the ability to manage Fault Tolerance and Load Balancing technology by using two Ethernet connections.
In order to use Fault Tolerance or Load Balancing a secondary Ethernet cable is required. The second ca
ble is connected to position G. (
Figure
2-1)
A second Ethernet connection is not required unless Fault Tolerance and Load Balancing is needed. The second Ethernet connection is not required for the initial setup.
2.3
Connectors on the Ba
kStor 2000 (2U-Unit)
Figure
2-2
Connectors on the BakStor 2000
Function
Connector
Function
Connector
Power
J1 and J2
External tape device 1 K1
Ethernet 0
F
External tape devi
ce 2 K2
Ethernet 1
P
Power Alarm reset
L
Ethernet 2
O
Ethernet 3
N
Ethernet 4
M
Ethernet 5
G
2.3.1 Power
Connect the two 3-pin 100/240V AC power cable to positions J1 and J2. (Figure
2-3)
Note that the power supplies are redundant; if one should fail the BakStor will still be able to operate. In the case of a power supply failure an alarm will bet set off. The alarm can be reset by pushing button L. (Figure
2-4)
J1
J2
L
P
O
N M
K2
K1
G
F
Page 17
Tandberg Data
BakStor Installation and Administration Manual
15
2.3.2 Ethernet 0
Connect the BakStor to the existing LAN by plugging an Ethernet cable to position F. Figure 2-5)
The Ethernet connection can be a 10/100/1000 Mbps to match capabilities of the connecting LAN.
2.3.3 Ethernet 5
The BakStor also has the ability to manage Fault Tolerance and Load Balancing technology by using two Ethernet connections.
In order to use Fault Tolerance or Load Balancing a secondary Ethernet cable is required. The second cable is c
onnected to position G. (Figure
2-6)
A second Ethernet connection is not required unless Fault Tolerance and / or Load Balancing is needed. The second Ethernet connection is not required for the initial setup
.
2.3.4 Ethernet 1 - 4
The four Ethernet connections labeled M, N, O and P (Figure 2-7) are to be used for connecting BakStor 2000EX expansion units. Do not connect these four Ethernet connections to a LAN.
2.4
Mountin
g the BakStor
When mounting the BakStor ensure that the unit is oriented correctly. When viewing a BakStor unit from the front correct orientation is ensured when:
The blue LED on each disk caddie is located on the RIGHT side of the caddie. On a BakStor 1
000 the powerbutton and reset button are located ABOVE the disk caddies.
On a BakStor 2000 the powerbutton is located in the LOW and LEFT corner of the front panel.
When viewing a BakStor unit from the rear correct orientation is ensured when:
The power c
onnectors are located on the LEFT side of the unit
The external SCSI controller is located on the RIGHT side of the unit
The BakStor is designed to operate in a position where it is lying flat.
CAUTION!
DO NOT OPERATE A BAKSTOR MOUNTED IN A SIDEWAYS OR
UPSIDE DOWN
POSITION.
Page 18
Tandberg Data
16
BakStor Installation and Administration Manual
2.5
External Tape Device
The BakStor can be connected to an external tape device or tape library. The external tape device or tape library is connected to the LVD SCSI controller build into the BakStor. A LVD SCSI cable is connected to position K1 on the BakStor 1000 (
Figure
2-1) or to position K1 or
K2.on the BakStor 2000 (Figure
2-8)
Note:
Ensure that when connecting external SCSI devices that all power from both the BakStor
and external tape device or tape library is switched off.
Note:
Ensure that external SCSI devices are connected with proper SCSI cables and proper
SCSI termination.
Note:
The BakStor use SCSI ID number 7. Ensure that a correct and unique SCSI ID
is selected
on any SCSI devices connected to the BakStor.
Note:
In order to ensure correct behavior and performance ensure that correct SCSI cables and
termination is used.
Page 19
Tandberg Data
BakStor Installation and Administration Manual
17
This Page Intentionally Left Blank
Page 20
Page 21
BakStor Installation
and Administration Manual
19
3
Configuration
3.1
Install Disk
Drive
The BakStor uses SATA disk drives. These are installed in the caddies provided. The BakStor 1U can use up to 4 disk drives and the BakStor 2U up to 12 disk drives.
The BakStor comes with the disks preinstalled in the caddies. Should this not be the case the disks will need to be mounted in the caddies before they are inserted into the BakStor.
3.2
RAID Setup
The BakStor 1U and 2U products come with one or multiple RAID-
5 preinstalled.
3.3
Network Setup
The BakStor 1U and 2U products come with the Ethernet 0
(connector F) preconfigured with an
IP address of 192.168.0.6. Please ensure that this setting will not generate a network conflict on the existing LAN and that
computers on the LAN are capable of communicating with the BakStor at this address. Failing to ensure this can lead to network problems for the LAN as well as failure to connect to
the BakStor.
3.4
Power
Press the power switch on the front panel to boot the NAS (
Figure
3-1). The unit will boot and
be available at the default IP a
ddress.
Figure
3-1
Indicators on the BakStor 1U Model
Page 22
Tandberg Data
20
BakStor Installation and Administration Manual
3.5
Connecting to the BakStor for the First Time
In order to connect to the BakStor enter the IP address of the BakStor in an internet browser.
The factor
y set default IP address is 192.168.0.6.
After connection is established a login dialog box will appear. The defaults username and password are:
Username: admin Password: pass
After the username and password have been verified the BakStor Welcome scree
n will appear.
In order to prevent unauthorized access to the BakStor the default password should be changed.
Figure
3-2
. BakStor Welcome Screen
Note:
The BakStor web interface makes use of inline frames. If you observe problems with displaying the inline frames in your browser please use the link on the BakStor Welcome screen to select using the No Frames version of the web interface
Page 23
Tandberg Data
BakStor Installation and Administration Manual
21
3.6
Shutting Down the BakStor
The BakStor Unit should always be shut down via the Maintenance menu before switching off power to the unit. This ensures a correct and clean shutdown.
Choose
Maintenance
? Shutdown BakStor
As an alternative, if no network connection is available, the unit can be switched off by pressing the power sw
itch on the front panel.
Note:
Press the power switch only briefly to allow the software to perform a controlled
shutdown. Keeping the switch pressed turns the power off causing an uncontrolled shutdown.
Figure
3-3
The BakStor front panel layout with power switch top right
3.7
Setting Up a RAID
After connecting to the BakStor one or more RAIDs must be configured. A RAID (Redundant Array of Independent Disks) makes it possible to configure several disk
drives i
nto one volume and can be configured to ensure data integrity in the case of disk failure.
The BakStor has been shipped with a default RAID configuration. Keeping this default RAID requires no action. Advanced RAID configuration is described in Chapter
4.
In order to view the current RAID set configuration choose
RAID Menu
? View RAID info
.
In order to view the current disk drive configuration choose
RAID Menu
? View drive info
.
Note: Accessible capacity
The size of a RAID reported by the BakStor is raw size. Total accessible capacity depends on operating environme
nt
Note: 2 TB limit
Note that the current version of the BakStor is not able to create a RAID larger than 2TB. Depending on the capacity of the disks in the BakStor this may mean that not all the disks can
be configured into a single RAID. In this case
multiple RAIDs must be configured.
3.8
Activating the RAID Storage
Before the RAID set can be used by the BakStor the RAID set needs to be activated. Choose
RAID Menu
? Add Array to BakStor
Select the correct RAID to activate from the menu. Note that already active RAID sets are not listed.
Page 24
Tandberg Data
22
BakStor Installation and Administration Manual
3.9
Choosing Slices or a Virtual Tape
A ‘slice’ is similar to a partition. Once a slice is created a computer will be able to access the slice over the iSCSI network as if it was a local disk drive.
A ‘Virtual Tape’ is a slice that emulates a standard LTO-2 tape drive allowing easy integration with current backup applications and infrastructures. Once the slice is created a computer will be able to access the slice as if it was a standard LTO-2 tape drive.
Please consult your system administrator in order to decide which is the most appropriate for your applications.
3.10 Creating Slices
When creating a slice simply define the name, capacity and whether the slice should be optimized for Windows or Linux / UNIX operating systems.
In order to create a slice choose
Storage menu
? Create a storage slice ? Create a disk slice
The following information needs to be entered:
Slice name. The
name for the slice.
Slice size. The size of the slice in MB.
Note: 1 GB (gigabyte) = 1024 MB (megabyte) 1 MB (megabyte) = 1024 kB (kilobyte) Optimize the slice (Windows/Linux)
Click the ACCEPT button to create the slice.
The screen will refresh and al
l defined slices will appear on the right side of the screen.
Figure
3-4
. Entering details for a disk slice
In order to create a Virtual Tape choose Storage menu ? Create a storage slice ? Create a virtual tape
Page 25
Tandberg Data
BakStor Installation and Administration Manual
23
The following information needs to be entered:
Slice name. The name for the slice. Slice size. This specified the maximum size the virtual tape can reach. Specifying 0
means no limit nd the vir
tual slice can grow until the RAID set underneath is full.
Click the ACCEPT button to create the virtual tape slice.
The screen will refresh and the virtual tape created will appear on the right side of the screen.
Figure
3-5
. Entering details for a tape slice
Note:
Tape Slice is allocated in 10GB blocks, so the size entered will be rounded up to the nearest 10GB. Entering 27000MB, for example, would make the actual size created be 30,000MB.
Page 26
Tandberg Data
24
BakStor Installation and Administration Manual
This Page Intentionally Left Blank
Page 27
Tandberg Data
BakStor User Manual
25
4
Advanced Configuration
4.1
Choosing a RAID Level
The BakStor is a disk based product which uses today’s industry approved disk management (RAID).
The advantages of choosing RAID are: Availability, Capacity and Performance. Choosing the right RAID level and drive failure management will give the right balance between Availability, Performance and Capacity.
Before the BakStor can allow disk availability to the user a RAID or logical drive must b
e
created. There are various levels of RAID that available with the BakStor:
RAID
-0
Disk striping
RAID
-1
Disk Mirroring
RAID-1 + hot spare
Disk Mirroring with dedicated ‘hot spare’ disk drive.
RAID
-5
Multiple Block Striping with Interspersed Parity
RAID-5 + hot spare Multiple Block Striping with Interspersed Parity and with
Dedicated ‘hot spare’ disk drive
4.1.1 RAID-0 (Disk Striping)
A RAID-0 allows multiple disks to be combined to create one large volume. Performance is greatly improved since all the disks are accessed in parallel and is considered to
be the fastest way to access multiple disks drives. A RAID-0 offers no protection against disk failure. If a single disk in the RAID-0 set should
fail, the entire RAID set will fail. If your environment depends on quick data access and less on protecting against disk drive
failure RAID-0 would be the best option.
Example:
In the BakStor there are 4 x 250GB capacity disk drives. By creating a RAID-0 one single logical drive with a size of 1000GB will be available instead of four single 250GB drives.
(4 x 250GB =1000GB usable)
Often RAID-0 is used for non-critical data that may only be an archive or second copy of data that is not accessed regularly and may be held for a short period.
2 TB limit
Note that the
current version of the BakStor is not able to create a RAID larger than 2TB.
Depending on the capacity of the disks in the BakStor this may mean that not all the disks can
Page 28
Tandberg Data
26
BakStor Installation and Administration Manual
be configured into a single RAID
-0.
For instance, with a disks size of 400GB, only
5 disks can be configured in a RAID-0 set.
In order to utilize all disks in a BakStor 2000, several RAID sets are needed.
4.1.2 RAID-1 (Disk Mirroring)
If your environment is more critical to data protection, RAID-1 offers protection against disk failure.
In a
RAID
-1 two disk drives are combined into a mirror configuration. All data written to the
mirror is then written to both disk drives. The upside to a RAID-1 configuration is that should one disk drive fail the second disk drive in
the mirror contains an ide
ntical mirror of the data.
The downside to a RAID-1 is the wastefulness of disk drives. Two disk drives are combined to offer the disk space of only one disk drive.
Note that a RAID-
1 setup will provide a RAID set that has the size of a single disk drive
even if more than two disk drives are specified for the RAID set. Specifying more than two disk drives will simply give multiple mirrors. For instance, specifying a RAID-1 with four disk drives will give a RAID set with four identical disk drives.
Example
:
In the BakStor there are 2x 250GB capacity disk drives. By creating a RAID-1 one single logical drive with a size of 250GB will be available instead of two single 250GB drives.
(2x 250GB – 1 x 250GB for mirror =250GB usable)
RAID-1 + hot spare (disk mi
rroring with dedicated replacement drive)
RAID
-1 + hot spare has the same instances as RAID-1 except it has a dedicated hot spare drive
that is not part of the Logical drive but stands by in case of a drive failure. In the case of a drive failure in one of
the two RAID-1 drives the BakStor will immediately start
the process of mirroring the data to the hot spare drive. RAID-1/RAID
-1 + hot spare are in use in critical access data applications, where capacity
comes second to data security and availability.
4.1.3 RAID-5 (Multiple Block Striping with Interspersed Parity)
In today’s data environment there is a fine balance between cost, protection and transfer speed. In some cases transfer speed can be slightly compromised against cost and protection. RAID-5 offers a good cost effective solution with high level of protection but without the costs incurred in mirroring solutions. RAID-5 creates a multiple block striping with interspersed parity enabling a security level that will allow access to the logical even if a drive fails. Obviously because of this calculation, data access time can affect the overall performance of the logical drive, but adversely the failed drive can be replaced and rebuilt using this interspersed parity to recalculate and rewrite the missing drives information giving a high level of data protection. Using the examples above the capacity is compromised, in comparison to the RAID-0 but is not
Page 29
Tandberg Data
BakStor Installation and Administration Manual
27
as compromised as RAID
-1.
Example
In the BakStor there are 4 x 250GB capacity disk drives. By creating a
RAID-5 one logical drive
with a size of 750GB will be available instead of four single 250GB drives. (4 x 250GB – 1 x 250GB for parity =750GB usable)
RAID-5+hot spare (Multiple Block Striping with Interspersed Parity and dedicated spare drive)
RAID
-5 + hot spare has the same instances as RAID5 except it has a dedicated hot spare drive
that is not part of the Logical drive but stands by in case of a drive failure. In case of a drive failure the BakStor will immediately start the process of incorporating the
spare drive into the RAID
-5.
Typically RAID-
5/RAID
-5 + hot spare are the most popular cost effective RAID level used in
today’s industry environments.
2 TB limit
Note that the current version of the BakStor is not able to create a RAID larger than 2TB. Depending on the capacity of the disks in the BakStor this may mean that not all the disks can
be configured into a single RAID. For instance, with a disks size of 400GB, only 6 disks can be configured in single RAID 5 set. In order to utilize all disks in
a BakStor 2000, several RAID sets are needed.
4.1.4 Shared hot spare drive
On a BakStor 2000 there are enough disk drives (12) to create multiple RAID sets. In order to cut down on the number of disk drives used as hot spare drives it is possible to configure a disk drive as a “shared spare drive”. This way one single disk drive can act as a hot spare for multiple RAID sets. In the case of a failure in one RAID set the shared spare drive will be used in this RAID set. If there is a failure in the second RAID set as well there will be no spare drive available for the second RAID set and it will run in degraded mode until the faulty disk in the second RAID set has been replaced.
Page 30
Tandberg Data
28
BakStor Installation and Administration Manual
4.2
Creating a RAID
When creating a RAID it is vital for the system administrator to be familiar with the respective disk drive positions. This is even more important for fault diagnosis to ensure that the incorrect drive is not removed during replacement of a faulty drive.
The disk drive locations on the 1U and 2U are as shown:
Figure
4-1
1U Drive Positions
Figure
4-2
2U Drive Positions
In order to create a RAID set choose
RAID Menu
? Create a RAID
The following information is needed:
Desired RAID level Disk drives to be included in the RAID
Click the ACCEPT button to start the process of creating the RAID.
Drive Slot 0
Drive Slot 1
Drive Slot 2
Drive Slot 3
Drive Slot 4
Drive Slot 5
Drive Slot 6
Drive Slot 7
Dr
ive Slot 8
Drive Slot 9
Drive Slot 10
Drive Slot 11
Drive Slot 0
Drive Slot 1
Drive Slot 2
Drive Slot 3
Page 31
Tandberg Data
BakStor Installation and Administration Manual
29
Figure
4-3
. Creating a RAID
In order to check the status of the RAID creation, choose
RAID Menu
? View RAID info
.
Note the screen has to be manually refreshed to update status.
When the RAID has finished
building the status will be shown as online.
Figure
4-4
. Status of a RAID during building
Page 32
Tandberg Data
30
BakStor Installation and Administration Manual
4.2.1 Activate newly build RAID
After a RAID has finished the building process it has to be activated before it can be put to use and before slices can
be created on top of the RAID.
Choose
RAID Menu
? Add array to BakStor
in order to activate the new RAID. Choose the correct RAID to activate and click the ACCEPT button. At this point the RAID is available for new slices. See Section 3.10 for details on configuring
slices.
4.3
RAID Failure
In the case of a disk drive failure, the RAID info screen will display information regarding the failure.
Choose
RAID Menu
? View RAID info
Figure
4-5
Status sho
wing a degraded RAID
Information on the exact disk drive that has failed can be found in the drive info menu. Choose
RAID Menu
? View drive info
The failed disk drive will be displayed with a status of “no-response”. Make a note of the slot number of the
failed disk drive.
Page 33
Tandberg Data
BakStor Installation and Administration Manual
31
Figure
4-6 Disk status showing a failed disk in the RAID. In this case the disk in slot 0 has
failed.
4.3.1 Repairing a RAID
First the failed disk drive needs to be remov
ed from the BakStor.
To configure the BakStor to expect a faulty disk drive to be removed, choose RAID menu
?
Repair a RAID
? Remove faulty drive
All currently failed disk drives will appear in the Select slot pull-down menu. Choose the disk drive to be removed and click the ACCEPT button.
Figure
4-7
Selecting a faulty disk drive to be removed
Once accepted, it is safe to physically remove the faulty drive. Take great care to ensure that the disk drive is removed from the correct hardware slot position.
Page 34
Tandberg Data
32
BakStor Installation and Administration Manual
Caution!
Ensure that the
correct disk drive is removed.
Removal of incorrect disk drive will cause data to be permanently lost.
Once the failed disk drive has been removed insert the replacement disk drive. After installing the replacement disk drive the BakStor must be configured to make use of the
new disk drive. Choose
RAID Menu
? Repair a RAID ? Scan for drives
Figure
4-8
Replacement disk drive detected
The replacement disk drive can then be configure
d into the RAID.
For a BakStor 1000, choose
RAID Menu
? Repair a RAID ? Add spare drive to RAID
For a BakStor 2000, choose
RAID Menu
? Spare drive menu ? Add spare drive to RAID
Page 35
Tandberg Data
BakStor Installation and Administration Manual
33
Figure
4-9
Selecting a disk drive to be inserted into the RAID
Notice that only disk drives currently not assigned to any RAID will appear in the Select drive slot pull-down menu.
Once the new disk drive has been successfully added to RAID the rebuild process will start automatically. The progress of the rebuild process can be monitored in the “view RAID Info” and “view drive info” screens.
Page 36
Tandberg Data
34
BakStor Installation and Administration Manual
4.3.2 Deleting a RAID
Before deleting a RAID ensure that all data has been removed from the slices located on the RAID set.
Caution!
Deleting a RAID set will cause any data on the RAID set to be permanently lost.
Then delete any disk slice or virtual tape slice located on the RAID set. Choose Storage Menu ? Delete a storage slice
and choose the slice(s) to delete.
The name of the slice must be entered twice to confirm. Click the ACCEPT button to delete the slice.
To delete a RAID choose
RAID Menu
? Delete a RAID
Choose the correct RAID set to delete and choose “Yes” for “Are you sure”.
Then click the ACCEPT button to delete t
he RAID.
Figure 4-10
Confirming the intention to delete a RAID
Page 37
Tandberg Data
BakStor Installation and Administration Manual
35
4.4
Snapshots
A snapshot makes it possible to take a point-in-time image of a disk slice. It is not a full copy of the disk slice, rather it is an image of what the disk slice looked like at the moment the snapshot was taken. As the original disk slice is modified the snapshot can be used to "go back in time" to the time the snapshot was taken. A snapshot can be exported and mounted on an iSCSI initi
ator computer just like a regular disk slice. The snapshots on a BakStor are both readable and writeable.
Since the only disk space used by a snapshot is the parts of the slice that has changed on either the original slice or the snapshot, the snapshot and the original slice share the majority of the disk space.
However, as the difference between the original slice and the snapshot increases the amount of space used for the snapshot will increase. If the BakStor runs of space to accommodate the growth of a snapshot the snapshot will become unavailable. The BakStor will intelligently allocate space for the snapshot on the RAID sets most suitable.
The BakStor has two methods for Snapshots: Scheduled and Instant
4.4.1 Creating Instant Snapshots
To create an instan
t snapshot, choose
Snapshot
? Create a snapshot
The following information must be provided:
Slice name
. The slice to take a snapshot of.
Snapshot size. This is the amount of disk space the snapshots starts with. The size is
specified as a percentage of the slice to take snap
shot of. If taking a snapshot of a disk slice of size 500GB and 10% is specified 50GB will initially be reserved for the snapshot.
Snapshot name. If the snapshot name is not defined the slice
-name date and time will be
used as the name of the snapshot
Then
click the ACCEPT button to create the snapshot.
Page 38
Tandberg Data
36
BakStor Installation and Administration Manual
Figure 4-11
Configuring an instant snapshot
4.4.2 Scheduling Snapshots
Snapshots can also be scheduled to run at a given time. To create a s
cheduled snapshot choose
Snapshot
? Schedule a snapshot
The following information will be needed
Slice name.
The slice to take a snapshot of.
Snapshot size. This is the amount of disk space the snapshots starts with. The size is
specified as a percentage o
f the slice to take snapshot of. If taking a snapshot of a disk slice of size 500GB and 10% is specified 50GB will initially be reserved for the snapshot.
Snapshot name.
If the snapshot name is not defined the slice-name date and time will be used
as the n
ame of the snapshot
The hour the snapshot will be taken. The day in the month the snapshot will be taken The month the snapshot will be taken
The snapshot schedule has now been set and will take place at the scheduled time/day/month.
Page 39
Tandberg Data
BakStor Installation and Administration Manual
37
Figure 4-12
Configuring a scheduled snapshot
If the snapshot name is not defined the slice-name date and time will be used as the name of the snapshot
Page 40
Tandberg Data
38
BakStor Installation and Administration Manual
4.5
Creating an AiiR Process
In addition to making a single snapshot (either instant or scheduled) the BakStor has an option for scheduling multiple snapshots to be scheduled.
The BakStor’s ‘AiiR’ module contains a snapshot scheduler that can configure and run up to 100 snapshots.
To set up an AiiR schedule choose AiiR
? Create an AiiR process
Info to enter:
Slice name. The slice to take a snapshot of. Snapshot capacity. The amount of space allocated for the AiiR process. Defined as
percent of the size of the slice to be taken snapshots of.
Number of rotations.
Number of snapshots to be taken. Start at time. The hour when the first snapshot in the schedule will be taken. Interval (hours/minutes). Time between the snapshots in the schedule. Skip between repetitions. Time between repetitions of the schedule Repeat
. Specify if the AiiR process repeat itself once completed
Click the ACCEPT button.
Figure 4-13
Configuring an AiiR process
The figure shows an example configuration for a 7-day cycl
e. The schedule uses five snapshots. The first snapshot is taken at 20:00 hours on the first day The process repeats for 5 cycles (in this case there are 24 hours between the snapshots). There is
then a skip of the next 48 hours (2 days), and then the sch
edule starts again.
Page 41
Tandberg Data
BakStor Installation and Administration Manual
39
4.5.1 Starting an AiiR Process
After having defined an AiiR process, the process must be started. Choose AiiR
? Start an AiiR process
Info to enter:
Slice name. The name of the slice for which the AiiR process has been defined.
Click the ACCEPT button.
Note: While an AiiR daemon is running the BakStor will monitor for free disk space available for the daemon. If more than 75% of the space allocated for the AiiR snapshots is used, the BakStor will automatically attempt to increase the snapshot space by 1GB. If there is not enough free disk space to increase the snapshot space the AiiR daemon will fail and no further snapshots will be made.
Page 42
Tandberg Data
40
BakStor Installation and Administration Manual
4.6
Adding Secure Authentication (CHAPs)
The BakStor 1U and 2U products both support secure authentication (CHAPs). This allows to set password protection on both the BakStor unit and also on individual slices and virtual tap
es.
4.6.1 Setting a Password for the BakStor
Setting a username and a password for the entire BakStor will prevent iSCSI initiators that do not have the username and password from connecting to the BakStor.
In order to set secure authentication for the BakStor unit choose Storage menu ? Access
control
? Set AC for BakStor
The following information is required:
Username. Using the name of the computer intended as the iSCSI initiator will help in
the administration of the iSCSI network.
Password
Click the ACCEPT button to activate the changes.
Figure 4-14
Configuring username and password for iSCSI login to the BakStor
Note:
Microsoft secure authentication requires that the password must have between 12 and 16
chara
cters with no space
Page 43
Tandberg Data
BakStor Installation and Administration Manual
41
4.6.2 Setting a Password for an Individual Slice
Instead of or in addition to restricting access to the entire BakStor access control can be configured for each defined slice.
This allows for even greater control over what iSCSI initiators can access a given resource on the BakStor.
In order to set secure authentication for an individual slice choose Storage Menu ? Access
control
? Set AC for a defined slice
The following information is required:
Slice name User name. Using the name of the co
mputer intended as the iSCSI initiator will help in
the administration of the iSCSI network.
Password
Figure 4-15
Configuring username and password for iSCSI login to an individual
slice on the
BakStor
Note:
Microsoft secure authentication requires that the password must have between 12 and 16
characters with no space
.
Page 44
Tandberg Data
42
BakStor Installation and Administration Manual
This Page Intentionally Left Blank
Page 45
Tandberg Data
BakStor User Manual
43
5
Connecting and Using External Units
5.1
Connecting a BakStor Expansion Unit
The BakStor Expansion Unit allows for more storage space to easily be added to the BakStor solution. The BakStor Expansion Unit is a 2U unit with 12 internal disk drives that compliments the BakStor 2000. In such a configuration the BakStor 2000 will be referred to as a BakStor Master Unit.
The BakStor Expansion Unit connects to the BakStor Master Unit by the use of a crossover Ethernet cable. This means that no new connection to the network is required. The BakStor Expansion Unit is managed from the same web interface and IP address that is used to manage the existing BakStor 2000.
Note that a dedicated Ethernet port is needed on the BakStor Master Unit for the BakStor Expansion Unit.
Multiple BakStor Expansion Units can be connected to a BakStor Master Unit by dedicating multiple Ethernet ports on the BakStor Master Unit, one Ethernet port for each BakStor Expansion Unit.
5.1.1 Preparing the BakStor Master Unit
Before connecting the BakStor Expansion Unit the current BakStor 2000 must be configured to act as a BakS
tor Master Unit.
Make sure that the firmware version running on the BakStor 2000 is capable of acting as a BakStor Master Unit.
Choose
Maintenance
? Show license info
The firmware version should end in “_master” in order to be an BakStor Master Unit. Also
verify that the top level menu option BakStor EX
is present.
An internal network will be configured between the two units, so the BakStor Master must have at least one available Ethernet port.
In order to configure the chosen Ethernet port as an Expansion
Port, choose
Configuration
? Network configuration ? Set Expansion port
From the menu choose the port to be configured as an Expansion port. Then click the ACCEPT button.
Note that any port already configured as Expansion ports are not available from the menu.
5.1.2 Connecti
ng the BakStor Expansion Unit
Use the crossover cable that came with the BakStor Expansion Unit and connect Ethernet port 0 on the BakStor Expansion Unit to the correct Ethernet port on the BakStor Master Unit.
The Ethernet port on the BakStor Master Unit
must have been configured as an Expansion port.
Page 46
Tandberg Data
44
BakStor Installation and Administration Manual
Ensure that the BakStor Master Unit is powered on and then power up the BakStor Expansion Unit.
When both units are running they will negotiate the settings to form a private network.
Caution!
The BakStor M
aster Unit and the BakStor Expansion Unit must be connected by the
means of an Ethernet crossover cable only.
Do not attempt to use an Ethernet switch or hub between the two units
5.1.3 Detecting and Configuring the BakStor Expansion Unit
In order to configure the BakStor Expansion Unit use the menu on the BakStor Master Unit and choose
BakStor EX
? Discover BakStor EX’s
This will probe for BakStor Expansion Units on all Ethernet port previously defined as Expansion Ports.
All discovered BakStor Expansion Units will be listed with the Ethernet port number to which they are connected.
Once
the BakStor Expansion Units are discovered they can be configured with RAID sets.
Choose BakStor EX
? Config / View BakStor EX
Then select the BakStor Expansion Unit to configure and click on the link in order to connect to the specified BakStor Expansion
Unit.
Once the web interface of the BakStor Expansion Unit has loaded choose
RAID Menu
? View RAID info
This will show any RAID that already may exist. If a new RAID set has to be created choose
RAID Menu
? Create a RAID
.
The RAID configuration menu for the BakStor Expansion Unit is identical to the RAID configuration menu for the BakStor Master Unit and the BakStor 2000. See Section 4.2
for more
details on configuring a RAID.
5.1.4 Activating RAID Sets on BakStor Expansion Unit
Aft
er configuring the desired RAID sets on the BakStor Expansion Unit choose
Master
BakStor
to move back to the web interface for the BakStor Master Unit.
To activate the new RAID choose
BakStor EX
? Attach / Detach EX storage
A list of RAID sets available will be listed. Choose the correct RAID to activate and click the ACCEPT button.
Page 47
Tandberg Data
BakStor Installation and Administration Manual
45
The RAID will now be available for creating disk and virtual tape slices. The disk and virtual tape slices are created from the web interface for the BakStor Master Unit. The process is identical to the normal process of creating slices. The RAID sets located on the BakStor Expansion Unit will be available just like RAID sets located on the BakStor Master Unit.
Note:
Once slices have been defined on the RAID sets located on the BakStor Expansion Unit the unit can no longer be detached from the BakStor Master Unit. If detachment is required the slices must be deleted. All data located on the slices will be lost.
5.1.5 Powering
down a BakStor Expansion Unit
Once slices have been created on the BakStor Expansion Unit it is an integrated part of the BakStor and cannot independently be powered down.
If it is required to power down the BakStor Expansion Unit (for example in order to physically relocate it) both the BakStor Expansion Unit and the BakStor Master Unit must be powered down.
In this case it is recommended to power down the BakStor Expansion Unit first, then power down the BakStor Master Unit. It is strongly recommended to
use the power-down option in the
menu system to shut the units down.
If it is required to permanently remove a BakStor Expansion Unit all slices located on the BakStor Expansion Unit must be deleted. All data located on these slices will be lost.
Choose
Storage Menu ? View slice location
to observe what slices are located on the BakStor
Expansion Unit Choose Storage menu ? Delete a storage slice
to delete the slices that are located on the
BakStor Expansion Unit
Note: All data located on these slices will be lost
Cho
ose
BakStor EX
? Attach / Detach EX storage
. Then click on “detach” for the RAID sets
located on the BakStor Expansion Unit. At this point the BakStor Expansion Unit can be powered down and removed.
Caution!
Powering down or disconnecting a BakStor Expan
sion Unit that has attached RAID sets
will cause the BakStor Master Unit to be non-operational
5.1.6 Failover Ethernet for Expansion Unit
The BakStor Expansion Unit is provided with two Ethernet connections. By using a second crossover cable the connection between the BakStor Master Unit and the BakStor Expansion Unit can be configured for failover (AFT).
Configure the BakStor Expansion Unit first, then the BakStor Master Unit.
1. Using the web interface for the BakStor Expansion Unit, choose
Configuration
?
Page 48
Tandberg Data
46
BakStor Installation and Administration Manual
Network configuration
? Global Configuration
Select Adapter Fault Tolerance (AFT) and click the ACCEPT button.
Note:
At this point the connection to the BakStor Expansion Unit may be disrupted. This is not a problem. When the BakStor Master Unit is completely configured the connection will be reestablished.
Note:
Only Adapter Fault Tolerance (AFT) is supported for the second Ethernet connection. Do not attempt to configure any other failover mode.
2. Using the web interface for the BakStor Master Unit, choo
se
Configuration
?
Network configuration
? Remove Expansion Port
Select the port currently assigned as an Expansion port for the given BakStor Expansion Unit. Click ACCEPT.
3. Choose
Configuration
? Network configuration ? Create a team
Select the two ports that are to form the AFT link to the BakStor Expansion Unit. Then select AFT as the mode. Click ACCEPT and ignore any error messages.
4. Choose
Configuration
? Network configuration ? Set Expansion Port
Select the team port from the list of ports and click the
ACCEPT button.
5. Choose
Configuration
? Network configuration ? Change IP configuration
Study the information frame on the right. At the bottom of this frame there is a list of all team ports. Locate the newly created team and
make a note of what port is lis
ted as Primary.
Make sure that the current crossover cable is connected to this port. (And not the other port in the team). If the current crossover cable is connected to the Secondary port move the cable to it is connected to the Primary port)
6. Choose
BakS
tor EX
? Discover BakStor EX’s
The BakStor Expansion Unit should be listed. If not listed rerun the discovery
7. Choose BakStor EX
? Config / View BakStor EX
Click on the link provided and connect to the BakStor Expansion Unit. Wait for the web interface for the Bak
Stor Expansion Unit to load.
8. From the menu on the BakStor Expansion Unit choose
Configuration
? Network
configuration
? IP configuration
The ports should be listed as being in Fault Tolerance Mode.
Make a note of what port is listed as Primary port. Ensure that the current crossover cable is connected to this port. If the current crossover cable is connected to the Secondary port move the cable to the Primary port and go back to step 6.
9.
When the crossover cable is confirmed connected to the correct port on
both the BakStor Master Unit and the BakStor Expansion Unit connect the second crossover cable. This cable is to be connected between the second port defined to be a member of the team on the BakStor Master Unit and the remaining port on the BakStor Expans
ion Unit.
At this point the connection between the BakStor Master Unit and the BakStor Expansion Unit will be in Adapter Failover Mode. This allows for the failure of one cable between the two units. Choose
BakStor EX ? Discover BakStor EX’s
to verify the connection between the BakStor
Master Unit and the BakStor Expansion Unit.
Page 49
Tandberg Data
BakStor Installation and Administration Manual
47
Should one of the Ethernet cables be disconnected the other cable will be used for communication between the two units. The failover will be transparent to any iSCSI initiators conn
ected to the BakStor.
Page 50
Tandberg Data
48
BakStor Installation and Administration Manual
5.2
Using an External Tape Device
The BakStor unit can be connected to an external SCSI tape device using the SCSI connections. This allows for moving data from the BakStor for offsite or archival storage. Standalone tape drives, ta
pe libraries and autoloaders can be used.
5.2.1 Connecting and Configuring a Stand-Alone Tape Device
In order to use an external tape device it first needs to be connected to the BakStor:
1.
Power down the BakStor.
2.
Connect the external tape device to the SCSI port on the BakStor. Make sure that proper SCSI cables and SCSI termination is used.
3.
Power up the external tape device.
4.
Power up the BakStor.
The tape device is now connected to the BakStor. Verify that the SCSI tape device was correctly recognized by the BakS
tor.
Choose
Backup Menu
? Tape control menu ? Scan for new tape device
This will provide a list of all tape devices recognized by the BakStor. If a tape library is connected a tape map of the library will be displayed as well.
If the tape device is
not r
ecognized
select yes and click the accept button to force the BakStor to
rescan the SCSI bus. If the tape device is still not recognized power down the BakStor and check the SCSI cables and
the SCSI termination on the SCSI bus.
5.2.2 Formats for moving data to
a physical tape
The BakStor can be used to move both diskslices and tapeslices to a physical tape. For diskslices a direct blocklevel copy of the data from the slice to the physical tape is
performed. The data can be restored from the physical tape to a
diskslice on the BakStor.
The data can be moved back to any BakStor unit should the original BakStor unit not be available.
The BakStor does have an option for encrypting the data before copying the data to a physical tape. If this option is used a password will be required before data can be copied from the physical tape.
For tapeslices (Virtual Tapes) there are two options for what format to use when copying data from the slice to the tape.
The data can either be copied in
native
mode or in
application mode.
Native mode creates a physical tape that is native to the BakStor. This creates a physical tape
Page 51
Tandberg Data
BakStor Installation and Administration Manual
49
that can only be restored on a BakStor unit. As with diskslices the data can be encrypted before it is copied to the physical tape.
Application mode creates a physical tape in a format of the application that was used to write to the Virtual Tape. Most backup software use a proprietary format when writing to a physical tape. Using the application mode allows the BakStor to create a physical tape that uses
this
proprietary format. A physical tape created in application mode can be restored on any computer that is fitted with a
physical tape drive capable of reading from the physical tape and backup software capable of reading the format used by the original
backup software.
Note that a physical tape created in application mode cannot be restored back to a BakStor unit. The physical tape can only be restored on a computer with the correct backup software and a correct physical tape drive.
5.2.3 Selecting encryption
method for moving data to physical tape
When copying a slice to physical tape the data may be encrypted. Different encryption algorithms are available for the data encryption.
Choose
Configuration -> Encryption configuration -> Select encryption method
Th
e different algorithms available are:
RC2 Blowfish CAST CAST5 DES Tripple-DES RC4
Page 52
Tandberg Data
50
BakStor Installation and Administration Manual
5.2.4 Checking contents of a physical tape
Before using a tape for backup purposed the contents of the tape should be checked. This prevents accidentally overwriting a tape contai
ning data that should be saved.
Choose
Backup Menu
? Restore menu ? Check tape contents
If the tape has previously been used to back up a slice from the BakStor the name of the slice will be displayed.
5.2.5 Defining a backup policy
Choose
Backup menu
? Defin
e / Redefine a BP
The following information needs to be entered:
Slice name. Specify the slice to be backed up. Do snapshot yes/no. If selected, the BakStor will make a snapshot of the slice to be
backed up before starting the backup process. The snapshot
will then be copied to tape and deleted once the copy process is done. This allows the slice to stay online and be used by an iSCSI initiator during the tape backup process. Any changes made to the slice after the snapshot is made will not be backed up to
the tape, but this option makes it
easier to control the state of the slice when it is copied to tape.
Tape drive. In the case of multiple tape drives this allows a specific device to be used for
the backup job.
Library slot. In the case of a tape library
this allows a specific slot in the library to be used. The BakStor will communicate with the library to ensure that the tape from the correct slot is loaded for the job.
Click the ACCEPT button to activate the BP
Note: There are some restrictions on back
ing up to physical tape:
1.
Only one slice can be backed up to one physical tape.
2.
The slice must be equal to or smaller than the physical tape. The BakStor will not span physical tapes. (This restriction includes spanning tapes in a tape library)
3.
The BakStor
performs a block level backup of the slice. The BakStor has no means of accessing the file system created by the iSCSI initiator and as such cannot perform a file level backup. This means the entire slice will be backed to tape, even if the slice contains
little or no actual data.
4.
If a diskslice is backed up to the tape containing the backup can only be restored on a BakStor unit.
5.
If a tapeslice is backed up and “native mode” is selected the tape containing the backup can only be restored on a BakStor unit.
6.
If a tapeslice is backed up and “application mode” is selected the tape containing the backup can not be restored on a BakStor unit, but must be restored on a computer outfitted with a correct physical tapeunit and correct backup software.
Page 53
Tandberg Data
BakStor Installation and Administration Manual
51
Figure
5-1
. Configuring a backup policy
Once the backup policy has been defined, it can be run immediately or scheduled to run at a later time.
To run the backup immediately, choose
Backup Menu
? Ru
n a defined backup now
.
Then choose the name of the slice to be backed up. Click the ACCEPT button to start the backup.
Figure
5-2
Starting a defined backup
Page 54
Tandberg Data
52
BakStor Installation and Administration Manual
5.3
Scheduling a Backup
To schedule a backup policy (BP) choose Backup Menu ? Perform Backup ? Set / Change schedule backup
The following information will be needed:
Slice name. Only slices that already have a backup policy listed are candidates for
backup scheduling.
Backup at (time). Specify the time for the backup. Date (day). Specify the day in the month for the backup Date (month). Specify the month for the backup Repeat. The backup can be specified to run once or be repeated. For repeat backup jobs
there are several options for the repeat interval:
Hourly. The job
is run once every hour at the minutes past full hour specified. Daily. The job is run every day at the hour and minutes specified Weekly. The job is run every seventh day, starting at the date and time specified. Monthly. The job is run once a month at th
e date and time specified.
Click the ACCEPT button to activate the changes.
Note:
With repeat jobs the backup job will use the tape present in the drive or library slot specified. No check will be done to verify if the tape contains data and any data already on the tape will be overwritten.
The backup schedule has now been created with start at the entered time/day/month.
Figure
5-3
Configuring a scheduled backup
Page 55
Tandberg Data
BakStor Installation and Administration Manual
53
5.4
Restoring from a Phy
sical Tape
After a successful backup to a physical tape the data can be restored should there be a need for it. The BakStor offers two different ways to restore from a tape, depending on whether or not the original slice still exists.
If the slice does ex
ist the BakStor can overwrite the current data on the slice with the data stored
on the physical tape. If the slice is no longer available on the BakStor or there is a need to restore the data on a
different BakStor unit it is possible to recreate the enti
re slice from physical tape.
5.4.1 Restoring data to a slice from a Physical Tape
In order to restore data to a slice from a physical tape select the slice to restore to. Choose
Backup Menu
? Restore Menu ? Restore by slice name
.
This will replace the data o
n the slice with the data on the physical tape.
If a contents check is needed for the physical tape choose Backup Menu ? Restore Menu ?
Check tape contents.
This will list the name of the slice contained on the tape. Do not use the “restore this slice” link as this is used for restoring the entire slice, not just the data.
Figure
5-4
Restoring data from a physical tape to an existing slice
Note: There are some restrictions on restorin
g data from a physical tape:
1.
Only restore the backup from tape to the same slice the backup was made from. Attempting to restore the data to a different slice may cause the slice to be corrupted.
2.
The original slice must exist and be available. If the origi
nal slice is deleted the
procedure for restoring a slice must be used.
Page 56
Tandberg Data
54
BakStor Installation and Administration Manual
5.4.2 Restoring a slice from a Physical tape
To restore a slice that no longer is present on the BakStor unit choose Backup Menu -> Restore Menu -> Check tape contents
This shows the name of the slice located on the physical tape. A link labeled “restore this slice” will be available. This restore process will generate a slice with the name of the slice on tape and restore the data to this slice.
Note:
There are some restrictions on restori
ng data from a physical tape:
1. When restoring a slice from a physical tape the original slice or a slice with the same name must not be present. The presence of a slice with the same name as the slice on the tape will cause the restore process to fail
2. There
must be sufficient space on the BakStor to allow the slice to be created.
Page 57
Tandberg Data
BakStor Installation and Administration Manual
55
6
Configuration Options
All models of the BakStor have at least two network ports. Some models may be equipped with more than two ports.
These network ports can be configured in
a number of various modes.
The BakStor can be configured to allow connections on different networks; it can be configured for distributing the load over a number of network connections; it can be configured to allow failover between network connections; its can be connected to BakStor EX units to increase the storage capacity.
6.1
Global Network Configuration
The global configuration menu allows configuring the mode of the network connections. Choose
Configurati
on
? Network configuration ? Global configuration
BakStor name. The iSCSI Target name used to identify this BakStor. In a setup with multiple
BakStor units it is recommended that each unit be given a unique name.
MODE Normal - In this mode both network ad
apters can have different network addresses
and so can operate on different networks
AFT – (Adapter fault Tolerance) Only one network adapter is active at a time. If the
Primary connection fails, the secondary takes over.
ALB – (Adaptive Load Balancing)
The transmission load is shared amongst both
adapters.
802.3ad – (Intel Link Aggregation) All adapters simultaneously transmit and receive
data. This includes fault tolerance and load balancing. Requires a switch that supports Intel Link Aggregation, Cisc
o Fast Ether Channel or Static 802.3ad.
Jumbo
Allows larger frame sizes to be used on network. Jumbo frames can only be
used if these frame sizes are supported by other hosts on network.
Please consult your
network administrator before emnabling Jumbo f
rames.
Page 58
Tandberg Data
56
BakStor Installation and Administration Manual
6.2
IP Configuration
Choose
Configuration
? Network configuration ? IP configuration
This allows the IP address of the different network connections on the BakStor to be configured.
Figure
6-1
Configuring IP a
ddress and settings
Page 59
Tandberg Data
BakStor Installation and Administration Manual
57
6.3
System Configuration
This menu allows for configuration of some system settings for the BakStor.
6.3.1 Setting a Password for the Administrator
This allows for setting and changing the password used to access the HTTP interface of the BakSto
r
Choose
Configuration ? Administrator Settings
Enter the new password 2 times and click the ACCEPT button. Note that the password needs to be between 4 and 16 characters and can only include the
characters [aA –zZ] and [0 –9]
6.3.2 Setting the System Time
Choose
Configu
ration
? Set Date/Time
The BakStor products use an internal clock that display time in UTC (Universal Time Coordinates). When setting the clock ensure that correct time is entered in UTC.
6.3.3 Setting an Email Address for Notifications
The BakStor can be configured to send emails for system events. Choose
Configuration
? Set Email notification
The following information is needed:
Email address of the recipient Address of a server that will accept SMTP requests Port number that the mail server will accept SMTP re
quests on
Email sender, an email alias for the BakStor. This can help the reception when setting up
mail filters etc.
Emails can be configured to be send for all system events (Always), just system failures (Failure) or never (Never)
Page 60
Tandberg Data
58
BakStor Installation and Administration Manual
6.4
iSCSI Configuration
6.4.1
S
tarting / Restarting the iSCSI Service
Choose
Configuration ? iSCSI configuration ? Start/Restart iSCSI Service
The iSCSI service is the service running on the BakStor that is responsible for exporting the defined slices. The service is automatically started when the BakStor starts, this menu options allows the se
rvice to be manually started / restarted at a later point should this be needed.
6.4.2 Stopping the iSCSI Service
Choose
Configuration
? iSCSI configuration ? Stop iSCSI Service
This option allows for a stop of the iSCSI service without shutting the BakStor down. iSCSI service is stopped the slices can no longer be accessed from an iSCSI initiator, but the webinterface is still accessable
6.4.3 Configuring iSCSI iSNS server
Choose
Configuration
? iSCSI configuration ? Set iSCSI iSNS server
This options allows for the configuration of an iSNS nameserver. The IP address of the iSNS server needs to be entered.
An iSNS server is an optional component for a larger iSCSI setup. It is an independent daemon running on a server connected to the LAN. This daemon allows iSCSI targets and iSCSI initiators to register with it and thus providing a single point to inquary for information regarding iSCSI devices.
Using such a daemon simplyfies the configuration of iSCSI initiators in a setup with multiple iSCSI targets since the iSCSI initiator only has to be configured to inquary the iSNS instead of being configured with the IP address of every iSCSI target
Page 61
BakStor User Manual
59
7
Maintenance
7.1
Update Code
The firmware in the BakStor can be upgraded can be upgraded to accommodate new features. Place the fil
e containing the upgraded firmware in a directory on your computer.
On the BakStor, choose
Maintenance ? Show license info
Choose "Browse" and locate the file containing the firmware. Then choose "Send File" to transfer the file to the BakStor.
Figure
7-1
Sending an upgrade file to
the BakStor
Browse allows searching of local system for updated firmware file.
Note: During the upgrade the webpage should not be refreshed. When the file is completely transferred a new page will appear with instructions to go to the main page and perform a reboot of the BakStor.
Page 62
Tandberg Data
60
BakStor Installation and Administration Manual
This Page Intentionally Left Blank
Page 63
BakStor User Manual
61
8
Appendix
8.1
iSCSI Initiator Installation
To make the created slice or virtual tape device available an iSCSI initiator must be installed. Depending on the operating system, this can be an iSCSI HBA adapter or an iSCSI software initiator.
Below is an example of how a Microsoft software initiator can be installed and utilized. The example used MS iSCSI initiator version 1.06. This iSCSI initiator can freely be downloaded from the Microsoft homep
age.
After downloading the appropriate version of software from the Microsoft website, installation is completed when the iSCSI initiator process is started in the services setup. This can be done automatically or manually depending on your preferred star
t up process
Please consult your system administrator for further information.
For computers running other Operating Systems there are several iSCSI initiator software packets available, both commercial and free as well closed and open source.
Page 64
Tandberg Data
62
BakStor Installation and Administration Manual
8.2
Importing
a Slice to a Windows iSCSI Initiator
1.
Start the iSCSI initiator program
2.
Select the “target portal” tab and add the IP address of the BakStor
3.
Select the “available targets” tab and choose the desired target
4.
Log On to the target
Page 65
Tandberg Data
BakStor Installation and Administration Manual
63
The slice is now available for the OS. If the slice is a diskslice it will show up as a normal SCSI raw disk. Use the normal disk
management tools to create partitions and filesystems on the disk. If the slice is a tapeslice (Virtual Tape) it will show up as a SCSI LTO tape device. Windows
may prompt for the installation of the appropriate tape device drivers. Once the appropriate device driver is installed the virtual tape device is ready for use.
Please
consult your administrator for device driver information if needed.
Page 66
Tandberg Data
64
BakStor Installation and Administration Manual
8.3
Using a Firewall
If there is a firewall located on the network between the iSCSI initiator and the BakStor ensure that the iSCSI traffic can be routed through the firewall. If firewall software is in use on the iSCSI initiator this may require configuration in order to allow iSCSI traffic.
By default TCP port 3260 is reserved for iSCSI traffic. The BakStor does not allow for changing the
default port.
If Internet Storage Name Service (iSNS) is in use, TCP port 3502 is the default port for this traffic.
Page 67
Tandberg Data
BakStor Installation and Administration Manual
65
This Page Intentionally Left Blank
Loading...