Video Communication Server Installation
116347 rev. 6
345
Connect the serial cable fr om the DATA port on the 1. VCS to the serial port on a PC.
Connect the Ethernet L AN cable from the LAN1 port 2. on the VCS to your net work.
Connect the p ower cable and turn the power on 1. using the power switch on the back right of the unit.
Press the sof t power but ton on the back left of the 2. unit.
6
The default IP A ddress of 192.168.0.100 will be visible in the display shor tly after power-up.
1
Unpack the unit.1. Remove the protective foil from the front panel.2.
VGA
o
I
192.168.0.100
2
Mount the rack ears and/or rubber feet, if applicable.1. Turn the unit back on its feet or mount it in the rack.2.
Video Communication Server Installation
8
Restart the system as follows:
Login with the username 1. adm in and your new password.
Press Enter to skip the inst allation wizard.2. Reboot the system by t yping the command3.
xcom ma nd bo ot. Disconnect the serial cable. 4.
Once the system has restarted you are now ready to begin configuring and using your TANDBERG Video Communication Server. Please refer to the CD that was shipped with your unit for full documentation.
116347 rev. 6
To connect to the VCS from the PC, start a terminal emulator progr am on the PC and configure it to use the PC’s serial port as follows:
baud rate: 115200 bits per second data bits: 8 parity: none stop bits: 1 flow control (hardware and sof tware): none
The terminal emulator p rogram on the PC will display the unit’s start up information, and af ter approximately 4 minutes you will get a login prompt. At the prompt:
Login with a username of 1. admin and the password TANDBERG.
Type 2. Y to start the installation wizard. Follow the prompts to set the password, IP protocol, 3.
IP Address, IP subnet mask, IP default gateway, ether­net speed, SSH and Telnet options.
When the installation wizard is finished, the following message will appear:
Setting other settings... OK. The system must be restarted for new settings to take effect.
TANDBERG recommends that if this
product is mounted in a rack you use
additional support accessories such
as rack side suppor t angles (rack
angle brackets) or rack shelves due
to the unit’s weight and depth.
Please contact your rack supplier to request the ac cessories best fitted
for your rack.