Tamarack Technologies TC1000 User Manual

TC1000
T
CPG.3
All Weather
VENTILATOR
PRODUCT MANUAL & INSTALLATION GUIDE
Serial Number
Date of Purchase
Point of Purchase
The serial number is located on the shipping carton and on a label affixed to the upper housing.
Unpacking your TC:
TC1000-T
One (1) TC1000-T One (1) Line Voltage Thermostat
The TC 1000 can be installed in one of three ways:
• In a glazing system -
system, an internal spacer to match the thickness of the glazing must be factory installed, or one fabricated on the site. If a spacer is site fabricated, please note that it must be installed UNDER the fan.
• On a conventional or stress skin panel roof -
After a 12 1/2" x 27" rough opening is cut through the roof, a sheet metal "thimble" should be installed to line the opening The fan should be installed using standard skylight flashing techniques and an optional grille is recommended to cover the opening in the ceiling.
• On a vertical wall -
it hits the edge of the fan.
The TC 1000 must be installed by a qualified installer. If it is to be installed in a double glazing
We strongly suggest installing a piece of flashing above the TC 1000 to sweep the rain away before
When you have unpacked your TC carefully you will find the following:
TC1000-H
All Weather
The TC 1000 will have no internal spacer - its flanges will be 1/4" thick.
One (1) TC1000-H All Weather Ventilator
CA
W
UT
WARNI
READ AND SAVE THESE INSTRUCTIONS
NG
:
TO
R
ED
U
C
E TH
E R
ISK O
F FIR
E, ELEC
Use
th
i
s u
n
i
t i
n
th
e
ma
n
n
e
r
i
n
te
n
d
e
d
b
y th Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally device, such as a tag, to the service panel. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities. Never place a switch where it can be reached from a tub or shower. Do not use this fan over a tub or shower. Do not use this fan over cooking appliances.
ARNING:
ION: F
To Red
or General
u
c
Venti
. When the service disconnect cannot be locked, securely fasten a prominent warning
e The Risk of Fir
l
ation Us
e or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
e Onl
y. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors
e
ma
TR
IC
SH
O
C
K, O
R
IN
JU
R
Y TO
PER
SO
N
S, O
BSER
VE TH
E FO
LLO
WIN
n
u
fa
ctu
r
e
r. If yo
u
h
a
ve
a
n
y q
u
e
sti
o
n
s, co
n
ta
ct th
e
ma
n
u
fa
ctu
r
e
r.
320 Main Street • Buzzards Bay, Ma 02532
508-759-4660 / 800-222-5932 / Fax 508-759-6001
G
:
Installation
Installing the TC1000 in a Wall
You will need the following items:
• Two pieces of 2x stock to match your existing framing
• Saw to cut the hole in the wall
• Hammer or Screw Gun to attach the blocking to the existing frame
• Phillips head Screwdriver to attach the grille
• Weather strip material
• Low expansion Spray Foam sealant
Add framing as shown to create a box of 12 1/2” x 27 3/4”. This box will act to hold the unit as well as creating a plenum for air movement. (Figure 1)
16” OC
1. Create a box to hold the unit (Fig. 1).
2. Remove the sheathing that covers the box.
3. Attach TC1000, screwing through the mounting flange.
4. Install exterior finish materials over the mounting flange. Note: additional flashing may be required above the unit to divert rain.
5. Remove any interior materials covering the box.
6. Install interior finish materials to trim the frame.
7. Attach optional grille to finish installation.
Wiring
mportant- Wiring the TC is different than a normal ON/OFF fan. The TC damper is motorized and
I
requires a constant source of power; power to open and power to close. The TC1000-T comes with a wall
ounted, line voltage thermostat. This thermostat is surface mounted and should be positioned at eye
m level. The TC1000-H comes with a SPST wall switch that is mounted in a standard single gang electrical box. A 3-wire will need to be run between the control point and the TC regardless of the model. Please follow the instructions carefully. It is recommended that the wiring of the TC be done by a licensed electrician in accordance with local code requirements.
Be sure to turn off power before wiring the TC Ventilation Fan
Please note that if the TC 1000 is installed in an enclosure
with a spa or hot tub or pool, a humidistat (optional item)
as well as a thermostat must be installed.
We strongly recommend a non-chlorine based
chemical for over the water applications.
Single and
Multiple TC’s
with Single
Control
Single and
Multiple TC’s
with Dual
Control
Be sure to tighten the strain relief prior to replacing the baseplate.
Troubleshooting
he most common installation error is caused by incorrect
T wiring. Be sure that each of the 3 wires in the TC1000 are connected individually. There is a 30 second delay after the control is activated and the damper opens before the fan motors start.
Care
All the motors in the TC are permanently sealed and do not require oiling. To keep dirt, dust and debris from the fans we recommend that you periodically remove the grille from within the living space and dust the fan blades. Please remember to make sure that the electrical circuit is OFF before dusting the fan blades.
Specifications
Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 VAC, 60 HZ, 110 watts, 1.5 A
Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 CFM @ .1 high
Effective R value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R 10.0
Rough opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.5” x 27”
Cover Height above flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5”
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Years
Safety Tested . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UL and CUL
LIMITED WARRANTY
or malfunctions in normal home use, Tamarack Technologies, Inc. will repair or replace the Product, at its discretion. Customer is responsible for shipping charges.
If, within the period of three years from the date of purchase, the TC 1000 (the Product) is defective
CONDITIONS, EXCLUSIONS, AND LIMITATIONS
This Warranty is subject to the following conditions, exclusions and limitations: THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM INSTALLATION, OPERATION OR MAINTENANCE THAT HAS BEEN UN­DERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS. THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT (FURNACES, SOLARIA, ETC.); FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS OTHER THAN TAMARACK TECHNOLOGIES, INC.; FROM ABUSE, ACCIDENTAL OR SHIPPING DAMAGE OR ACTS OF GOD. THIS WARRANTY DOES NOT APPLY TO THE PRODUCT USED OUTSIDE THE UNITED STATES, ITS TERRITORIAL POSSESSIONS, AND CANADA. EXCEPT AS SET FORTH ABOVE, NO EXPRESS OR IMPLIED WARRANTY IS GIVEN OR AUTHORIZED BY TAMARACK TECHNOLOGIES, INC. AND ALL OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED. ANY WARRANTY OR MERCHANTABILITY OF FITNESS FOR ANY PAR­TICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER. MOREOVER, ANY LIABILITY OF TAMARACK TECHNOLOGIES, INC. FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT VALUE OF THE PRODUCT. IN NO EVENT SHALL TAMARACK TECH­NOLOGIES, INC. BE LIABLE FOR ANY INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGES, IR­RESPECTIVE OF THE CAUSE THEREOF, OCCURRING EITHER DURING OR AFTER THE WARRANTY PERIOD, INCLUDING WITHOUT LIMITATION ANY DAMAGES TO ANY PART OF A BUILDING OR ITS CONTENTS. NOTE: SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AND SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
PROOF OF PURCHASE REQUIRED.
320 Main Street • Buzzards Bay, Ma 02532
508-759-4660 / 800-222-5932 / Fax 508-759-6001