THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LES PRODUIT ET
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS
WEBS-WM / WEBS-WM-12 Wall Mounts – Installation Instructions
I. Introduction
Model WEBS-WM / WEBS-WM-12 Wall Mount units are designed to house the Talk-A-Phone Blue Light; paging
amplifier and horns; and a Talk-A-Phone 400-Series or 500-Series ADA compliant hands-free Emergency Phone.
In addition to the Emergency Phone Station, this unit is designed to work as part of a Wide-Area Emergency
Broadcast System.
II. Installation
To install the Wall Mount, after site preparation (including telephone/data line and provision of power for the Blue
Light and faceplate light), follow these steps:
1. The Wall Mount is held to the wall with 4 #10 screws. Install two #10 screws in order to hold the top
section to the wall. Note that the screws should be located so that the Wall Mount will be at the
desired height and in the correct position to receive any conduit connections.
2. Electric power and the telephone/data line can be brought into the unit in one of two ways:
a. There is one large opening in the back of the unit to allow the unit to be mounted over a flush
mounted standard electrical outlet box and/or flush mounted telephone connector box.
b. There are two conduit openings available on the bottom of the unit to feed the power and/or
telephone/data line inside the unit (Note: Power and telephone/data lines cannot be ran in same
conduit).
3. Remove the cap lid from the Wall Mount by removing the four #10 spanner security screws located on
the side of the unit. DO NOT remove the Lexan shield from the unit. Mount the unit on the wall using
the two keyholes on the top rear of the unit to the two screws mounted to the wall in step 1.
4. Install two additional #10 screws of the appropriate type in the holes in the lower rear of the unit.
Tighten all four screws.
5. Install conduit over the bottom hole(s) of the unit if method (b) is being used (see step 2) and bring
Talk-A-Phone Co. • 7530 North Natchez Avenue • Niles, Illinois 60714-3804 Rev. 7/6/12
All prices and specifications are subject to change without notice.
power line and/or telephone/data line inside the unit.
Copyright 2012 Talk-A-Phone Co. All rights reserved.
Phone 773.539.1100 • Fax 773.539.1241 • info@talkaphone.com • www.talkaphone.com
Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.
WEBS-WM Wall Mounts – Installation Instructions
Faceplate LED Light
6. The LED light board operates on 12V up to 120V AC/DC and is non-polarity sensitive.
For the WEBS-WM, connect the Faceplate LED Light to the output of the power supply inside the unit.
Connect the input of the power supply 120VAC - 240VAC, 60Hz (wiring: brown - positive and blue neutral).
For the WEBS-WM-12 (12VDC power option), connect the Faceplate LED Light to the incoming
12VDC.
Blue Light
7. For the WEBS-WM connect the ETP-EL12/24 Blue Light power cable (white - positive and black negative) to 12VDC output voltage of the power supply provided inside the unit. Connect the input of
the power supply to 120VAC - 240VAC, 60Hz (wiring: brown - positive and blue - neutral).
For the WEBS-WM-12 (12VDC power option) connect the ETP-EL 12/24 to the incoming 12VDC.
Auxiliary Connections
8. When using the ETP-EL12/24 Blue Light with ETP-400 Series Emergency Phones, connect the
orange and black auxiliary control cable pair of the Blue Light to the orange and black wires of the
Emergency Phone. Refer to the Emergency Phone Manual for information regarding the programming
of your phone.
9. When using the ETP-EL12/24 Series Blue Light with VOIP-500 Series Emergency Phones, connect
the orange and black auxiliary control cable pair of the Blue Light to positions 3 and 4 (Aux. Output 2)
of the 6-pin connector plug of the VOIP-500 Series Phone. Refer to the Emergency Phone Manual for
information regarding the programming of your phone.
Paging Horns and Amplifier
10. The amplifier and horns are installed inside the unit prior to shipment. Connect the Amplifier Audio
Line Level Input to the Audio Line Level Output of either the VOIP-500 Series Emergency phones,
WEBS-CM-2 or the WEBS-ZPS.
11. Connect Amplifier Trigger pair (blue and orange) to either of the Aux. Outputs of the Emergency
Phone. Refer to the Emergency Phone Manual for information regarding the programming of your
phone.
12. For the WEBS-WM, connect the input power supply of the amplifier to 120VAC - 240VAC, 60Hz
(wiring: brown - positive and blue - neutral).
For the WEBS-WM-12 (12VDC power option), connect the amplifier to 12VDC (wiring: white - positive
and black - negative).
Talk-A-Phone Co. • 7530 North Natchez Avenue • Niles, Illinois 60714-3804 Page 2 of 3
Phone 773.539.1100 • Fax 773.539.1241 • info@talkaphone.com • www.talkaphone.com
All prices and specifications are subject to change without notice.
Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.
Copyright 2012 Talk-A-Phone Co. All rights reserved.