Talbsys Basic Vortex, Standard Vortex, Advanced Vortex, Pulsing Vortex Instruction Manual

INSTRUCTION MANUAL
INSTRUCTION MANUAL
Basic Vortex Mixer
Standard Vortex Mixer
Advanced Vortex Mixer
Pulsing Vortex Mixer
table of contents
Package Contents . . . . . . . . . . . . . . . 1
Warranty . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . 2
Maintenance & Servicing . . . . . . . . . . . . . . . 2
Environmental Conditions . . . . . . . . . . . . . . . 2
Safety Instructions . . . . . . . . . . . . . . . 3
Standards & Regulations . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . 4
Digital & Pulsing Vortex Mixer Control Panel . . . . . . . . . . . . . . . 5
Introduction . . . . . . . . . . . . . . . 6
Operating Instructions . . . . . . . . . . . . . . . 6-7
Head/Accessory Installation Instructions . . . . . . . . . . . . . . . 8-9
Troubleshooting . . . . . . . . . . . . . . . 10
Accessories . . . . . . . . . . . . . . . 11-12
Package contents
Fixed Speed, Analog, Digital or Pulsing Vortex Mixer 72” (183cm) power cord * (1) cup head * (1) 3” (7.6cm) head * (1) 3” (7.6cm) rubber head cover Instruction manual Warranty card
* These accessories come with all units except the Pulsing Vortex Mixer which is
supplied with a 1.5 to 2mL Micro-Tube Holder with built-in cup head.
1
Warranty
Manufacturer warrants this product to be free from defects in material and workmanship when used under normal conditions for five (5) years. Please complete and return the enclosed warranty card. For your reference, make a note of the serial number, date of purchase and supplier here.
Serial Number: _______________________________________________________
Date of Purchase: ____________________________________________________
Supplier: ____________________________________________________________
installation environmental conDitions
Upon receiving the Talboys’ Vortex Mixer, check to ensure that no damage has occurred during shipment. It is important that any damage that occurred in transport is detected at the time of unpacking. If you do find such damage the carrier must be notified immediately.
After unpacking, place the Vortex Mixer on a level bench or table, away from explosive vapors. Ensure that the surface on which the unit is placed will withstand typical heat produced by the unit. Always place the unit on a sturdy work surface.
The Vortex Mixer is supplied with a power cord that should be plugged into a properly grounded outlet. If the supplied power cord does not meet your needs, please use an approved power cord that suits local codes and electric supply. Replacement of the plug must be made by a qualified electrician.
maintenance & servicing
The Vortex Mixer is built for long, trouble-free, dependable service. No lubrication or other technical user maintenance is required.
The unit should be given the care normally required for any electrical appliance. Avoid wetting or unnecessary exposure to fumes. Spills should be removed promptly. DO NOT use a cleaning agent or solvent on the front panel which is abrasive or harmful to plastics, nor one which is flammable. Always ensure the power is disconnected from the unit prior to any cleaning. If the unit ever requires service, contact your Talboys’ representative.
Operating Conditions: Indoor use only. Temperature: 4 to 40°C (39.2 to 104°F) Humidity: 20% to 85% relative humidity, non-condensing Altitude: 0 to 6,562 ft. (2000 M) above sea level
Non-Operating Storage:
Temperature: -20 to 65°C (-4 to 149°F) Humidity: 20% to 85% relative humidity, non-condensing
Installation Category II and Pollution Degree 2 in accordance with IEC 664.
equiPment DisPosal
This equipment must not be disposed of with unsorted waste. It is your responsibility
to correctly dispose of the equipment at life-cycle-end by handing it over to an authorized facility for separate collection and recycling. It is also your responsibility to decontaminate the equipment in case of biological, chemical and/or radiological contamination, so as to protect the persons involved in the disposal and recycling of the equipment from health hazards.
For more information about where you can drop off your waste of equipment, please contact your local dealer from whom you originally purchased this equipment. By doing so, you will help to conserve natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health.
2
safety instructions stanDarDs & regulations
Please read the entire instruction manual before operating the Vortex Mixer.
WARNING! DO NOT use the Vortex Mixer in a hazardous atmosphere or with hazardous materials for which the unit was not designed. Also, the user should be aware that the protection provided by the equipment may be impaired if used with accessories not provided or recommended by the manufacturer, or used in a manner not specified by the manufacturer.
Always operate unit on a level surface for best performance and maximum safety.
DO NOT lift the Vortex Mixer by the head. All heads, including cup head, are removable. They can pop off if lifted by them.
CAUTION! To avoid electrical shock, completely cut off power to the unit by disconnecting the power cord from the wall outlet. Disconnect unit from the power supply prior to maintenance and servicing.
Spills should be removed promptly. DO NOT immerse the unit for cleaning.
DO NOT operate the unit if it shows signs of electrical or mechanical damage.
Earth Ground - Protective Conductor Terminal
Alternating Current
Henry Troemner LLC hereby declares under it’s sole responsibility that the construction of this product conforms in accordance with the following standards:
Associated EU guidelines:
EMC directive 2004/108/EC LVD directive 2006/95/EC Machine directive 98/37/EC
Safety standards:
IEC 61010-1 Safety requirements for electrical equipment for measurement,
control and laboratory use. Part I: General Requirements.
IEC 61010-2-051 Part II: Particular requirements for laboratory equipment for
mixing and stirring.
UL Std. No. 61010-1
EMC standards:
EN 45501 IEC 61000-4-3 EN 55022A IEC 61000-4-4 IEC 6100-3-2 IEC 61000-4-5 IEC 61000-3-3 IEC 61000-4-6 IEC 61000-4-2 IEC 61000-4-11
3
fixeD sPeeD vortexer mixer sPecifications Digital & Pulsing vortexer mixer sPecifications
Overall dimensions (L x W x H): 8 x 5 x 5.25” (20.3 x 12.7 x 13.3cm)
Electrical (50/60 Hz): 120V: 1.2 amps, 150 watts 230V: 0.6 amps, 150 watts
Speed range*: 3200rpm ** Orbit: 0.194” (4.9mm) Duty rating: intermittent duty Controls: none Ship weight: 14.4lbs (6.5kg)
analog vortexer mixer sPecifications
Overall dimensions (L x W x H): 8 x 5 x 5.25” (20.3 x 12.7 x 13.3cm)
Electrical (50/60 Hz): 120V: 1.2 amps, 150 watts 230V: 0.6 amps, 150 watts
Speed range*: 300 to 3200rpm ** Orbit: 0.194” (4.9mm) Duty rating: intermittent duty Controls: auto/off/on rocker switch,
speed knob: variable 1 to 10 dial marks
Ship weight: 14.4lbs (6.5kg)
Overall dimensions (L x W x H): 8 x 5 x 5.25”
(20.3 x 12.7 x 13.3cm) Electrical (50/60 Hz): 120V: 1.2 amps, 150 watts
230V: 0.6 amps, 150 watts
Speed range*:
On mode: 500 to 3000rpm ** Auto mode: 1000 to 3000rpm ** Pulse mode: 3000rpm **
Timer: 1 second to 9999 minutes (increased in 1 second increments)
Orbit: Digital unit: 0.194” (4.9mm) Pulsing unit: 0.098” (2.5mm)
Duty rating: intermittent duty Controls: see page 5 Ship weight: 14.4lbs (6.5kg)
* Maximum speed will vary depending on accessory being used. ** 230V units maximum speed: 2500rpm
4