Takex PB-30TK, PB-60TK, PB-100TK Instruction Manual

PHOTOELECTRIC BEAM SENSOR
INSTRUCTION MANUAL
We appreciate your purchase of our photoelectric beam sensor. This sensor will provide long and dependable service when properly installed. Please read this Instruction Manual carefully for correct and effective use.
Please note: This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
We are not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.
[TRANSMITTER]
COVER
COVER
Terminals
Operational
LED
Lens
Lens
View finder
Terminals
Alarm LED
Attenuation
LED
Lens
Lens
View finder
Horizontal adjustment
Vertical adjustment screw
Response time adjustment
Monitor jack
Horizontal adjustment
Vertical adjustment screw
MOUNTING PLATE
MOUNTING PLATE
[OPTION PARTS]
Pole mounting plate: 2
Pole bracket: 2
[RECEIVER]
Attenuation sheet: 1
Tapping screw: 4
DO’S AND DONT’S
Remove all obstructions (trees, clothes lines, etc.) between Transmitter and Receiver.
Do not install the unit on places where it may be splashed by dirty water or direct sea spray.
Avoid strong light from the sun, automobile headlights etc. directly shining on Transmitter / Receiver. When strong light stays in optical axis for a long time, it does not cause malfunction but will affect the product life.
Do not install the unit on unsteady surfaces.
The protection distance (between Transmitter / Receiver)
should be placed in the rated range.
PB-30TK : Outdoor : 100’ (30m) / indoor : 200’ (60m) PB-60TK : Outdoor : 200’ (60m) / indoor : 400’ (120m) PB-100TK : Outdoor : 330’ (100m) / indoor : 660’ (200m)
Expansion of beam
Expansion of beam can be calculated as follows: A=0.03 x l
l A
66’ (20m) 2’(0.6m) 135’ (40m) 4’ (1.2m) 200’ (60m) 6’ (1.8m)
330’ (100m) 10’ (3.0m)
Transmitter
Receiver
Protection distance
POINTS OF INSTALLATION
Heights of installation
Install the sensor at a height of 31" to 39" (80 to 100cm) to catch human pattern.
Position of installation
Using the adjustments, the lens can move horizontally ( ±90 degrees) and vertically (±10 degrees) allowing the unit to work in all directions. ( example 1 to 3)
Vertical
adjustment
screw
±10˚
±90˚
Horizontal adjustment
Exemple 1 Exemple 2 Exemple 3
CAUTIONS ON INSTALLATION
Avoid overhead wiring
When installing indoors, wiring procedures similar to those for telephones or intercoms are acceptable. Outdoor wires should be placed inside pipes, or underground cable / metal shielded cable should be used.
Terminal configuration
Connection
Power
10V to 30VDC (non-polarity)
Power
10V to 30VDC
(non-polarity)
[Receiver]
[Transmitter]
Alarm
NC NC
COM NO
Alarm output Dry contact relay Output 1c 30V (AC/DC) 0.5A
When cover attached
Tamper output Dry contact relay Output N/C 30V (AC/DC) 0.5A
Wiring distance
model PB-30TK PB-60TK, PB-100TK
voltage 12V 24V 12V 24V
wire size
AWG22 720’ 6200’ 490’ 4200’
(Dia 0.65mm) (220m) (1890m) (150m) (1280m)
AWG20 1200’ 10500’ 830’ 7200’
(Dia 0.8mm) (366m) (3200m) (250m) (2200m)
AWG18 1800’ 16000’ 1200’ 10500’
(Dia 1.0mm) (549m) (4880m) (366m) (3200m)
AWG17 2200’ 20000’ 1450’ 13500’
(Dia 1.1mm) (670m) (6000m) (442m) (4000m)
Note 1) Maximum wiring distance when two or more sets are connected
is the value above divided by the number of sets.
2) The signal line can be wired to a distance of up to 3,300 ft. (1,000m) with AWG22 (dia 0.65mm) telephone wire.
Example connection 1
Example connection 2
Example connection 3
Transmitter Receiver
Control panel
(12VDC)
Power
Alarm signal
TR. RE. TR. RE.
TR. RE. TR. RE.
Control panel
(12VDC)
Power
Alarm signal
Control panel
(12VDC)
Power
Alarm (1ch.)
Alarm (2ch.)
31" to 39"
(80 to 100cm)
1) Remove cover from unit and slide the mounting plate to detach it.
2) Pull wire through on the installation site.
3) Break grommet on mounting plate and pull wire through it. Secure the plate with 4mm screws.
Pull wire through sensor body (back to front) and attach it to the mounting plate.
4) When exposed wired, break knockouts (2 positions) on the rear of unit, pull wire through as the figure and attach it to the mounting plate.
Wiring from the top
Grommet
Knockout
Knockout
Wiring from the bottom
5) After wiring is completed, adjust alignment, check operation and attach cover.
Note Sealing is not required for unit surround due to
rain-proof construction.
*
The grommet is compatible with a wire of ø0.12” (ø3mm) to ø0.24” (ø6mm) outer dia. When a wire of more than ø0.24” (ø6mm) outer dia. is used, cut off the dotted line portion on the below figure by pliers or the like. Then make corking to prevent insects from entering into the unit.
Grommet
()
View finder
View finder
Horizontal adjustment
Vertical adjustment screw Clockwise: Upward Counterclockwise: Downward
Further, fine tune until receiver attenuation LED is OFF.
When the unit is used outdoors, a tester is advisable to be used for adjustment. You can confirm the beam level by inserting a tester in monitor jack of Receiver.
The reference follows:
Monitor output voltage Alignment (outdoor) Alignment (indoor)
700mV or more Best
Best
250mV to 700mV Good 60mV to 250mV Good Less than 60mV
Re-adjustment
Re-adjustment
Note: The above voltage shows attenuation sheet condition.
Supply power with cover detached.
Set Transmitter lens to Receiver lens. The view finder is placed between 2 lenses. Look through view finder on either side and line-up optics horizontally and vertically until the opposite unit is visible. (Hold the mental portion and change horizontal angle.)
Alarm Led Attenuation LED
Tester
Receiver
Attenuation sheet
For outdoor use, adjust with attenuation sheet on until attenuation LED is OFF. After adjustment, take out attenuation sheet.
Adjust response time as follows. The unit does not detect the passing object faster than the response time set. If the response time is set longer, the unit does not detect human beings. Adjust to a little longer response time in a site where large passing objects, such as birds, newspaper or carton box may move.
(Testing) Units should be tested on a regular monthly basis. To
test, walk in front of Receiver and watch to see if the walk test LED lights as the beam is blocked. Relay function should be confirmed by watching status light on control panel.
(Maintenance) Our photoelectric beams are virtually maintenance free,
with the exception of units that are located in dusty or dirty environments. Dirty units should be cleaned off with a damp cloth as necessary.
Response time (sec.)
0.05 (standard)
(0.3)
0.7
Response 0.05 sec.
Run at full speed
Response 0.3 sec.
Walk with quick steps
Response 0.7 sec.
Walking
Wall Mount
Symptom Possible Cause Remedy Operation LED 1. No power supply. 1. Turn on the power.
does not light 2. Bad wiring connection or broken wire, short. 2. Check wiring. Alarm LED does 1. No power supply. 1. Turn on the power supply.
not light when the 2. Bad wiring connection or broken wire, short. 2. Check wiring. beam is broken 3. Beam is reflected on another object and sent into the receiver. 3. Remove the reflecting object or change beam direction.
4. Two beams are not broken simultaneously. 4. Break two beams simultaneously.
5. The beam interruption time is shorter than the set response time. 5. Set the response time shorter.
Alarm LED continues 1. Beam alignment is out. 1. Check and adjust again. to light. 2. Shading object between Transmitter and Receiver. 2. Remove the shading object.
3. Optics of units are soiled. 3. Clean the optics with a soft cloth.
Intermittent alarms 1. Bad wiring connection. 1. Check again.
2. Change of supply voltage. 2. Stabilize supply voltage.
3. Shading object between Transmitter and Receiver. 3. Remove the shading object.
4. A large electric noise source, such as power machine, is located 4. Change the place for installation. nearby Transmitter and Receiver.
5. Unstable installation of Transmitter and Receiver. 5. Stabilize.
6. Soiled optics of Transmitter and Receiver. 6. Clean the optics with a soft cloth.
7. Improper alignment. 7. Check and adjust again.
8. Small animals may pass through the 2 beams. 8. Set the response time longer. (Impossible in a site
where an intruder can run at full speed.)
Model PB-30TK PB-60TK PB-100TK Detection system Simultaneous breaking of 2 beams
Infrared beam LED pulsed beam, Double modulation Protection distance
Outdoor 100’ (30m) or less Outdoor 200’ (60m) or less Outdoor 330’ (100m) or less
Indoor 200’(60m) or less Indoor 400’(120m) or less Indoor 660’(200m) or less
Max.beam range
Outdoor 1000’ (300m) or less Outdoor 2000’ (600m) or less Outdoor 3300’ (1000m) or less
(Approximation)
Indoor 1000’(300m) or less Indoor 2000’(600m) or less Indoor 3300’(1000m) or less
Response time 50msec.to 700msec. (Variable at pot) Supply voltage 10V to 30VDC (Non-polarity) Current
53mA or less 80mA or less
consumption
Dry contact relay output form C Contact action: Interruption time + delay time
Alarm output
(1 to 3 sec.)
Contact capacity: 30V AC/DC, 0.5A or less Dry contact relay N/C
Tamper output Action :
Activated when cover is detached.
Contact capacity:30V AC/DC, 0.5A or less
Alarm LED
Red LED (Receiver) ON: when an alarm is initiated
Attenuation LED
Red LED (Receiver) ON: when beam is attenuated
Functions
Monitor jack output AGC circuit, Frost proof cover
Ambient temperature
-13ºF to +140ºF (-25ºC to +60ºC)
range Mounting positions Indoor / Outdoor Wiring Terminals Weight Transmitter: 13.3oz (380g) Receiver:14oz (400g) Appearance PC resin (wine red)
Limited Warranty
All TAKEX Products are subject to 5 years warranty. All other warranty periods agreed are subject to a formal written agreement. During the warranty period, TAKEX Europe Ltd. will repair or replace, as its sole option, free of charge, any defective parts returned prepaid. Our warranty does not cover damage or failure caused by Acts of God, abuse, misuse, abnormal usage, faulty installation, improper maintenance, unauthorised customer modifications or any repairs other than those carried out by TAKEX Europe Ltd.
TAKEX EUROPE LTD.
Aviary Court, Wade Road, Basingstoke, HANTS RG24 8PE UK Tel. +44(0)1256-475555 Fax.+44(0)1256-466268 Email: sales@takexeurope.com Webpage: www.takexeurope.com
Knockout
Knockout
Grommet
PB-100TK IM-10/04 (CRI-174)
The specifications are subject to change without notice.
Loading...