1) DO'S AND DON'TS
2) Height of installation
Install the unit at a height of 3.3' (1m), ground to center of microwave sensor, to detect human being walking or running through the beam.
Do not install the unit at places
Do not install the unit a street side
or in parking lots where many cars may pass by. Installation must be at 5ft. (1.5m) away from the automobiles trafc.
Do not install the unit on
unsteady surfaces.
When installing the unit along
the side of a building or fence, installation must be at least
3.3ft. (1m) away from said constructions.
3.3'
(1m)
3) Check the environment of the installation site
The microwaves are affected by electric waves reected from buildings, fences, and or the ground. The beam reception level of the microwaves depends on how the unit is installed in the area, especially by the height of installation. Find the position (height) of the sensor for transmitter and receiver respenctively where the maximum signal reception level can be obtained before the nal.
3.3' (1.0m)
3.3' (1.0m)
5'
(1.5m)
Pole cover
3
CAUTIONS ON INSTALLATION
2
PARTS DESCRIPTION
1
PRODUCT DESCRIPTION
InstructionManual
We appreciate your purchase of the TAKEX microwave sensor. This sensor will provide long and dependable service when properly installed. Please read this instruction manual carefully for correct and effective use. Please note : This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary or a crime preventing device. TAKEX is not responsible for damage, injury or loss caused by accident, theft, Acts of God (including inductive by lightnin surges), abuse, misuse, abnormal usage faulty installation or improper maintenance.
MICROWAVE SENSOR
MW-100AL
This Product consists of a transmitter which sends 24GHz band of microwave and a receiver which receives the beam. It will initiate an alarm signal when the receiver detects a drop in the beam reception level due to interruption of objects interrupt between the transmitter and receiver. Compared to a photoelectric beam, the wavelength of microwaves is extremely long, which prevent the sensor from being affected by weather such as torrential rainfall, snowfall, fog or frost especially during cold winters. Stable detection performance is possible. Two types of frequencies, MW-100AH and MW-100AL are available.
Cover
Knockout
Top and bottom
Accessories
Tapping screw
(φ4×30mm6
Countersunk screw
(M4×20mm4
Bracket2
Optional (BP-100MW)
3.3' (1m) or less
Vertical angle adjustment screw
Adjustment dial
Adjustment mode switch
Monitor jack Receiver only
Tamper switch
Response time adjustment potentiometer
Transmitter:
Transmission LED
Receiver :Alarm LED
LED
Receiver only
Receiver only
Antenna
View finder
Install the sensor at a proper height and position otherwise detection area could be widened over 6.6' (2m). This could cause the sensor to detect movements of cars or vegetations near the area and lead to frequent false alarms.
Note:
A core detection area is approximately φ2' (0.6m) as indicated above as A, when the alignment is correctly adjusted. It is suggested to make at least 3.3' (1m) open space on either side of detection area to prevent faise alarm.
Please check the detection area by walking test. 
Do not stack the sensors vertically.
16.5'to330'(5mto100m)
A
Don't install this unit in location where it is exposed to direct sunlight or halogen light. It may become a cause of malfunction.
Don't face the mirror unit to the sun directly during installing or replacing.It may become a cause of malfunction.
Don't install other than correct direction. (at slant, at upside down)
It is buried in snow etc.
Freezing
φapprox
3.3'to6.6' (1to2m)
φapprox2'(0.6m)
Don't operate less than 3.3' (1m) detection distance between transmitter and receiver even for operation checking.
When two or more sets are used, two frequencies (L and H types) should be used in order to avoid cross talk or interference. Refer to the following example.
H type should be used for TR3 and RE3 when TR1 and RE1 are L type.
Do not install the transmitter and the receiver at a same corner. Microwave sensor with the same frequency can be used for this case.
Mounting
3) Wall mount
4) Pole mount
5) Pole mounting back to back.
Make holes in the wall.
Place the mounting plate the wall as a template for drilling
and mark the screw holes. (Allow a space of 1" (25mm) above and below the plate. This will provide easy detachment of the cover after installation.)
Install the sensor.
Insert tapping screws to 0.59" (15mm) under the screw head.Install the mounting plate on the
wall after pulling the wire through it.
Connect terminals.Attach cover.
Install sensor on the pole.
Attach the U brackets to pole and x the mounting plate
with screws.
Fix the sensor the body to the mounting plate.Connect the terminals.Attach the sensor and pole covers.
(Break the knockouts on the cover and pole cover to adapt to pole's diameter and conguration.)
Attach the two U brackets to
the poles, one on top of the other, facing opposite directions.
(See illustration.)
Make a wiring hole in the pole. Pull
through wire.
2) Turn the anntenna of each unit by 90 degrees right or left. Then loosen the screws (2 places) to remove the mounting plate from the body.
1) Detach cover with a screw driver.
Wood
φ
0.12"
(φ3mm)
Concrete
Use plug etc.
Installation example
Linear protection (long distance)
Perimeter protection
1.38" (35mm) or more
1" (25mm) or more
0.59" (15mm)
The grommet is compatible with a wire of φ0.12" (φ3mm)
to φ0.24" (φ6mm) outer diameter.
When a wire of more than φ0.24"
(φ6mm) outer dia. is used, cut off the dotted line portion as illustrated using pliers or the like. Then use caulking to prevent insects from entering into unit.
Grommet
4
INSTALLATION
Pre-drill in wall.
Concrete wall : Refer to specications of the securing plug used.
Wooden wall : 0.12" (3mm) diameter.
TR1
TR
TR
TR
TR
TR3
TR2
RE2
(Ltype)
(Ltype)
(Htype)
330' (100m)
330' (100m)
330' (100m)
1' (0.3m)
1'to16.5'
(0.3mto5m)
RE1
RE3
RE
RE
RE
RE
(Ex.1) (Ex.2) (Ex.3)
Protected site
Do not use different frequencies (H and L) in a detection line.Use a pair of same frequency : TR(H) and RE(H) OR TR(L) and RE(L).Do not stack the sensors vertically.
(Top view)
(Top view)
±90°
±10°
90°
90°
(Option)
Knockout
φ1.77"(φ45mm) φ1.50"(φ38mm)
Loading...
+ 2 hidden pages