Takagi T-KJr2-IN, T-K4-IN, T-D2-IN, T-KJr2-OS, T-K4-OS Installation Manual And Owner's Manual

...
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
-WHAT TO DO IF YOU SMELL GAS
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
-Installation and service must be performed by a qualified installer, service agency or the gas supplier.
FEATURING
ENDLESS HOT WATER ON DEMAND USAGE COMPACT, SPACE SAVING ENERGY CONSERVATION COMPUTERIZED SAFETY NO PILOT LIGHT EASY-LINK SYSTEM
510 (T-D2) models only
Gas Tankless Water Heater
Suitable for potable water heating a nd spa ce -heating
*
*Please refer to local codes for space-heating compliance.
If you have any questions, please
call or write to:
500 Tennessee Waltz Parkway Ashland City, TN 37015
Toll Free:
1-
877-737-2840
On-Demand Water Heater
Installation Manual and Owner’s Guide
Model
s
110 Indoor (T-KJr2-IN) ・110 Outdoor (T-KJr2-OS)
310 Indoor (T-K4-IN) ・310 Outdoor (T-K4-OS)
510 Indoor (T-D2-IN) ・510 Outdoor (T-D2-OS)
WARNING
If the information in these
instructions is not followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
ANSI
Z21.10.3
and CSA 4.3
510 (T
-
D2) models
only
Contents
2Page
CONTENTS
SPECIFICATIONS…………………………………………………………………………………………..………………………... INTRODUCTION…………………………………………………………………………………………………..…………………. SAFETY GUIDELINES…………….………………………………………………………………………………………..……….. INSTALLATION………………………………………………………………………………………………..…………………..…. General………………………………………………………………………………………………………………………..…..… Clearances……………………………………………………………………………………………………………………………
Included Accessories…………….………………………………………………………………………………………..….. Optional Items…………………………………………………………………………………………………………………….. High-Altitude Installations……………………………………………………………………………………………………
.
Venting Instructions……………………………………………………………………………………………………………
..
Gas Supply and Gas Pipe Sizing………......................................................................................
Water Connections……………..…………………………………………………………………………………………….…
Electrical Connections……………………………………………………………………..…………………………….......
Remote Controller Connections……..………………………………………………………………………………….
Pump Control Connections…………………………………………..………..………..
……………………………………
Easy-Link System...…………………………....…………………………………………………………………………..…..
..
APPLICATIONS...……………………………………………………………………………………………………………………… INITIAL OPERATION..………………………………………………………………………………………………………….……
OPERATING SAFETY………………………………………………………………………………………………………………… NORMAL OPERATION…………………………………………………………………………………………………………..…
General………..……….………….…………………………………………………………………………………………………
Temperature Settings.…….……..……………………………………………………………………………………………
Flow…………………………………………………………………………………………………………………………………….
Freeze Protection System…….…………………………………………………………………………………………..…
Maintenance and Service………………………………………………………………………………………………….…
Unit Draining and Filter Cleaning………………………………………………………………………………………… TROUBLESHOOTING……..……………………………………………………………………………………………………..…
General………..……….………….…………………………………………………………………………………………………
Error Codes.…………………….…..……………………………………………………………………………………………
COMPONENTS DIAGRAM……………………………………………………………………………………………………..… PARTS LIST………………….………………………………………………………………………………………………..………… OUTPUT TEMPERATURE CHART…………………………………………………………………………………………...…
LIMITED WARRANTY…………………………………………………………....…………………………………………….….
3 4 5 6 6 8 8 9 11
12 17 20 21 22 23 24 28 30
31
33 33 33 35 35 36 36 37 37 39 42 46 49 51
Installation Manual
Owner’s Guide
Specifications
3│Page
SPECIFICATIONS
Model
110
Indoor
(T-KJr2-IN)
110
Outdoor
(T-KJr2-OS)
310
Indoor
(T-K4-IN)
310
Outdoor
(T-K4-OS)
510
Indoor
(T-D2-IN)
510
Outdoor
(T-D2-OS)
Natural Gas Input
(Operating Range
)
Min: 19,500 Btu/h
Max: 1
40
,000 Btu/h
Min: 11,000 Btu/h
Max: 19
0
,000 Btu/h
Min: 11,000 Btu/h
Max: 199,000 Btu/h
Propane Input (Operating Range)
Min: 19,500 Btu/h Max: 140,000 Btu/h
Min: 11,000 Btu/h Max: 190,000 Btu/h
Min: 11,000 Btu/h Max: 199,000 Btu/h
Gas Connection
¾” NPT
Water Connections
¾” NPT
Water Pressure
15 - 150 psi*
Natural Gas
Inlet Pressure
Min. 5.0” WC
Max. 10.5” WC
Propane Inlet Pressure
Min. 8.0” WC
Max. 14.0” WC
Manifold Pressure**
Natural 2.0” WC 2.5” WC 2.0” WC 2.5” WC 2.0” WC 2.5” WC
Propane 2.5” WC 3.1” WC 3.7” WC 4.0” WC 3.7” WC 4.5” WC
Weight 33 lbs. 38 lbs. 39 lbs.
Dimensions
H20.5” x W13.8” x D6.7”
H20.5” x W13.8” x D8.5”
Ignition Electric Ignition
Electric
Supply 120 VAC / 60 Hz
Consumption
Operation
73.1 W / 0.61 A 87.6 W / 0.73 A 89.8 W / 0.75 A
Standby 6.2 W / 0.05 A 6.2 W / 0.05 A 6.2 W / 0.05 A
Freeze­Protection
111 W / 0.93 A 111 W / 0.93 A 111 W / 0.93 A
*40 psi or above is recommended for maximum flow
.
**The Manifold Pressure is the factory setting and generally should not need adjustment.
NOTE:
Check the rating plate to ensure this product matches your specifications. In accordance with ANSI Z21.10.3, CO emission does not exceed 400 PPM for
normal input.
The manufacturer reserves the right to discontinue, or change at any time,
specifications or designs without notice and without incurring obligations
.
I
I
I
n
n
n
s
s
s
t
t
t
a
a
a
l
l
l
l
l
l
a
a
a
t
t
t
i
i
i
o
o
o
n
n
n
M
M
M
a
a
a
n
n
n
u
u
u
a
a
a
l
l
l
Introduction
4Page
INTRODUCTION
*This diagram
illustrates tankless water heater design concepts only and does not accurately represent to the water heater’s physical description.
This manual provides information necessary for the installation, operation, and
maintenance of the water heater.
The model description is listed on the rating plate which is attached to the front panel
of the water heater.
Please read all installation instructions completely before installing this product.
If you have any problems or questions regarding this equipment, consult with the
manufacturer or its local representative.
This equipment is an on-demand, tankless water heater designed to efficiently supply
endless hot water for your needs.
The principle behind tankless water heaters is simple:
1. A hot water tap is turned on.
2. Water enters the heater.
3. The water flow sensor detects the water flow.
4. The computer initiates the fan motor and sends a signal to the igniter to create an ignition
spark.
5. The gas ignites and flames appear within the burner chamber.
6. Water circulates through the heat exchanger and then gets hot.
7. Using thermistors to measure temperatures throughout the water heater, the computer
modulates the gas and water valves to ensure proper output water temperature.
The 110 Indoor (T-KJr2-IN), 310 Indoor (T-K4-IN) and 510 Indoor (T-D2-IN) models are
to be only installed indoor (direct-vent convertible). The 110 Outdoor (T-KJr2-OS), 310
Outdoor
(T-K4-
OS) and 510 Outdoor (T
-D2-
OS) models ar
e to
be only installed outdoor.
Safety Guidelines
5Page
W
ater temperature
s over 125°F
(52°C)
can cause severe burns instantly or
death
from scalding. The water temperature is set at 122°F (50°C) from the factory to minimize any scalding risk. Before bathing or showering always check the water temperature.
Do not store or use gasoline or other flammables, vapors, or liquids in the vicinity
of this appliance.
Do not reverse the water and/or gas connections as this will damage the gas
valves and can cause severe injury or death. Follow the diagram on p. 20 when installing your water heater.
Do not use this appliance if any part has been in contact with or been immersed
in water. Immediately call a licensed plumber, a licensed gas fitter, or a professional service technician to inspect and/or service the unit if necessary.
Do not disconnect the electrical supply if the ambient temperature will drop
below freezing. The Freeze Prevention System only works if the unit has electrical power. The warranty will not be covered if the heat exchanger is damaged due to freezing. Refer to the section on the Freeze Prevention System on p. 35 for more
information
.
SAFETY GUIDELINES
SAFETY DEFINITIONS
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates an imminently hazardous situation which, if not avoided, could result in death or serious injury.
Indicates an imminently hazardous situation which, if not avoided, could result in minor or moderate injury.
GENERAL
1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the
National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the USA or CAN/CSA B149.1 Natural Gas, Propane Installation Code in Canada.
2. Properly ground the unit in accordance with all local codes or in the absence of local codes, with
the National Electrical Codes: ANSI/NFPA 70 in the USA or CSA standard C22.1 Canada Electrical Code Part 1 in Canada.
3. Carefully plan where you intend to install the water heater. Please ensure:
Your water heater will have enough combustible air and proper ventilation. Locate your heater where water leakage will not damage surrounding areas (please refer
to p. 7).
4. Check the rating plate for the correct GAS TYPE, GAS PRESSURE, WATER PRESSURE and ELECTRIC
RATING.
*If this unit does not match your requirements, do not install and consult with the manufacturer.
5. If any problem should occur, turn off all hot water taps and turn off the gas. Then call a trained
technician or the Gas Company or the manufacturer.
WARNING
CAUTION
DANGER
WARNING
Installation
6Page
INSTALLATION
GENERAL
1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the
National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the USA or CAN/CSA B149.1 Natural Gas, Propane Installation Code in Canada.
2. All gas water heaters require careful and correct installation to ensure safe and efficient
operation. This manual must be followed exactly. Read the “Safety Guidelines” section.
3. The manifold gas pressure is preset at the factory. It is computer controlled and should not
need adjustment.
4. Maintain proper space for servicing. Install the unit so that it can be connected or removed
easily. Refer to the Clearances Section on p. 8 for proper clearances.
5. The water heater must be installed in a location where the proper amount of combustible air
will be available to it at all times without obstructions.
6. The electrical connection requires a means of disconnection, to terminate power to the water
heater for servicing and safety purposes.
7. Do not install the unit where the exhaust vent is pointing into any opening in a building or where
the noise may disturb your neighbors. Make sure the vent termination meets the required distance by local code from any doorway or opening to prevent exhaust from entering a building (refer to p. 15).
8. Particles from flour, aerosols, and other contaminants may clog the air vent or reduce the
functions of the rotating fan and cause improper burning of the gas. Regularly ensure that the area around the unit is dust- or debris-free; regular maintenance is recommended for these types of environment.
9. If you will be installing the water heater in a contaminated area with a high level of dust, sand,
flour, aerosols or other contaminants/chemicals, they can become airborne and enter and build up within the fan and burner causing damage to the water heater.
10. For the 110 Indoor (T-KJr2-IN), 310 Indoor (T-K4-IN) and 510 Indoor (T-D2-IN) models:
These units may be converted to a direct-vent (sealed combustion) appliance by installing a
direct-vent conversion kit Part No. 9007667005 (TK-TV10) which will bring in all required combustible air from outside the building. When installing the direct-vent conversion kit, please follow all instructions included with the kit.
If the water heater is used as a direct-vent appliance, the unit requires a 3” combustible air
supply pipe. The intake pipe must be sealed airtight. Air supply pipe can be made of ABS, PVC, galvanized steel, corrugated aluminum, corrugated stainless steel or Category III stainless steel.
Terminating the venting through a sidewall is recommended for the direct-vent system. Running the exhaust vent and the intake pipe parallel is recommended. Terminating the exhaust and intake on the same wall / surface is recommended.
Terminating in the same pressure zone allows for pressure balancing, which prevents nuisance shutdowns.
11. For the 110 Outdoor (T-KJr2-OS), 310 Outdoor (T-K4-OS) and 510 Outdoor (T-D2-OS) models:
To be installed outdoors and only in areas with mild, temperate climates.
Installation
7Page
Installation and service must be performed by a qualified installer (for
example, a licensed plumber or gas fitter), otherwise the warranty will be void.
The installer (licensed professional) is responsible for the correct installation
of the water heater and for compliance with all national, state/provincial, and local codes.
The manufacturer does not recommend installing the water heater in a pit or
location where gas and water can accumulate.
Do not have the vent terminal pointing toward any operating window, door, or
opening into a building.
Do not install next to any source of airborne debris, such as a clothes dryer,
that can cause debris to be trapped inside the combustion chamber, unless the system is direct-vented.
The manufacturer does not recommend installing the water heater in an
attic due to safety issues. If you install the water heater in an attic:
Make sure the unit will have enough combustion air and proper ventilation. Keep the area around the water heater clean. When dust collects on the
flame sensor, the water heater will shut down on an error code.
If the above conditions cannot be met, use the direct vent conversion kit
Part No. 9007667005 (TK-TV10).
Place the unit for easy access for service and maintenance. A drain pan, or other means of protection against water damage, is
required to be installed under the water heater in case of leaks
.
The warranty will not cover damage caused by water quality.
Only potable water or potable water / glycol mixtures can be used with this
water heater. Do not introduce pool or spa water, or any chemically treated water into the water heater.
Water hardness levels must not exceed 7 grains per gallon (120 ppm) for
single family domestic applications or more than 4 grains per gallon (70 ppm) for all other types of applications. Water hardness leads to scale formation and may affect/damage the water heater. Hard water scaling must be avoided or controlled by proper water treatment.
Water pH levels must be between 6.5 and 8.5 Well water must be treated.
Do not install the unit where water, debris, or flammable vapors may get into
the flue terminal.
The manufacturer recommends using the direct vent kit when the water
heater is installed in a beauty salon. Some chemicals used in a beauty salon may affect the flame sensor. Water heater may not work properly.
Although the water heater is designed to operate with minimal sound, the
manufacturer does not recommend installing the unit on a wall adjacent to a bedroom, or a room that is intended for quiet study or meditation, etc.
Locate your heater close to a drain where water leakage will not do damage to
surrounding areas. As with any water heating appliance, the potential for leakage at some time in the life of the product does exist. The manufacturer will not be responsible for any water damage that may occur. If you install a drain pan under the unit, ensure that it will not restrict the combustion air
flow.
CAUTION
WARNING
Installation
8Page
CLEARANCES
Mode
l Top Bottom
Front
Back Sides
110 Indoor* (
T-KJr2-IN)* 12” 12” 24” 1” 2 “
110 Outdoor (
T-KJr2-OS) 36” 12” 24” 1” 2 “
Model
Top Bottom
Front
Back Sides
310 Indoor
* (T-K4-IN)* 12” 12” 24” 1” 2 “ 310 Outdoor (
T-K4-OS) 36” 12” 24” 1” 2 “
Model
Top Bottom
Front
Back Sides
510 Indoor* (
T-D2-IN)* 12” 12” 24” 1” 2 “
510 Outdoor (
T-D2-OS) 36” 12” 24” 1” 2 “
*Standard indoor installations and direct-vent indoor installations have the same clearances.
INCLUDED ACCESSORIES
Check that these items below are included with the water heater.
1. Installation Manual and Owner’s Guide
2.
Product Registration Card
3. Communication Cable
510 (T-D2) models only
Qty: 1
Qty: 1
Qty: 1
Bottom
Side Top
Side
Front
Back
Maintain a
ll clearances around
the water heater.
Installation
9Page
OPTIONAL ITEMS
Model
110 Indoor
(T-KJr2-IN)
110 Outdoor
(T-KJr2-OS)
310 Indoor
(T-K4-IN)
310 Outdoor
(T-K4-OS)
510 Indoor
(T-D2-IN)
510 Outdoor
(T-D2-OS)
9007666005
(TK-
RE02
)
9007603005
(TM-
RE30
)
9007678005
(TK-
BF01
)
9007667005
(TK-
TV10
)
9007670005
(TK-
PC01
)
9007671005
(TK-
PCJr2
)
90076
74005
(TK-
RB02
)
9007608005
(TK-KPWL4)
9007609005
(TK-
KPWH4
)
9007680005
(TK-
KPCT43
)
1. Temperature Remote Controller
:
9007666005
(TK-RE02)
The Temperature Remote Controller has two functions. It allows the output temperature from the water heater to be adjusted within the range of 99 °F to 167 °F, and it also
works as a diagnostic tool that will give a concise error code whenever there is a problem with the unit. The temperature options are 99°F, 100°F, 102°F, 104°F, 106°F, 108°F, 109°F, 111°F, 113°F, 115°F, 117°F, 122°F, 131°F, 140°F, 158°F, and 167°F. See the trouble shooting section
for information on possible error codes.
2. Temperature Remote Controller
:
9007603005
(TM-RE30)
The Temperature Remote Controller has two functions. It allows the output temperature from the water heater to be adjusted within the range of 99 °F to 185 °F, and it also
works as a diagnostic tool that will give a concise error code whenever there is a problem with the unit. The temperature options are 99°F, 100°F, 102°F, 104°F, 106°F, 108°F, 110°F, 111°F, 113°F, 115°F, 117°F, 122°F, 131°F, 140°F, 149°F, 158°F, 167°F, 176°F and 185°F. See the trouble shooting section for information on possible error codes.
3. Backflow Preventer: 9007678005 (TK-BF01)
The Backflow preventer prevents the backflow of air through the exhaust vent. This helps prevent harmful exhaust gases from entering the home, as well as
helping to prevent the unit from freezing in areas where cold air can be blown or drawn into the exhaust system. Install this vent damper in accordance with the installation instructions and any applicable codes.
4. Direct-Vent Conversion Kit: 9007667005 (TK-TV10)
This kit can be used to
convert the water heater from a standard vent system to a direct-vent (or sealed combustion) system. Install this
conversion kit in accordance with the installation instructions and any applicable codes.
Installation
10Page
5. Pipe Covers: 9007670005 (TK-PC01) and 9007671005 (TK-PCJr2)
The pipe cover protects the plumbing pipes to the water heater from unexpected adjustments. This pipe cover is fixed to the bottom of the water heater, which hides the plumbing and improves the visual aspects of the whole
installation
for the water heater.
6. Recess box: 9007674005 (TK-RB02)
The Recess box will allow for “clean” installations. The water heater fits inside the recess box, which hides and protects the whole water h
eater and plumbing.
The Recess box will fit in-between most wall studs.
7. T-Vent Wall Thimble with Termination: 9007608005 (TK-KPWL4) and 9007609005 (TK-KPWH4)
These terminations are used when venting out through the wall and are compatible with the T-Vent pipe system. These terminations are special stainless steel vents for gas appliances and are UL listed as Category II, III and IV. There are two types of terminations: the Louver termination and the Hood termination. For different wall thicknesses, there are two ranges of lengths available (refer to the venting brochure for details). Install these vent terminations in accordance with their installation instructions and any applicable local codes.
8. Direct-Vent Concentric Termination: 9007680005 (TK-KPCT43)
Used when terminating direct-vent (sealed-combustion) systems, with direct-vent models that require a 3” intake and a 4” exhaust. This concentric termination provides the convenience of only having to make one penetration through a sidewall instead of two separate penetrations for the intake and exhaust piping. The termination includes a bird screen, restricting small animals, pests, and foreign objects from entering into the vent system. This sidewall termination is available in three different sizes, to
cover all ranges of wall thicknesses
.
Direct
-
vent Concentric
Termination
Part#
Covering wall thickness
9007680005 (
TK-KPCT43
-1) 3.9” –
7.1”
9007772005 (
TK-KPCT43
-2) 6.9” –
10.1”
9007773005 (
TK-KPCT43
-3) 9.8” –
13.0”
Louver
Termination 9007608005
(TK-KPWL4)
Hood
Termination 9007609005 (TK-KPWH4)
Installation
11Page
DO NOT adjust any dipswitches on the right bank for the 510 (T-D2) models. The dark squares indicate the direction the dipswitches should be set to.
Dipswitches
HIGH-ALTITUDE INSTALLATIONS
Check the elevation where your water heater is installed. Set dipswitches shown in the table below depending on the altitude.
Altitude
0 to 2,000 ft
(DEFAULT)
2,000 to 4,000 ft
4,000 to 6,000 ft Over 6,000 ft
Switch No.3
OFF
ON
OFF
Consult our Technical Services Department at 1-877­737-2840
Switch No.4
OFF
OFF
ON
Altitude
0 to 2,0
00 ft
(DEFAULT)
2,000 to 4,000 ft
4,000 to 6,000 ft Over 6,000 ft
Switch No.4
OFF
ON
OFF
Consult our Technical Services Department at 1-877­737-2840
Switch No.5
OFF
OFF
ON
110 (T-KJr2) and 310 (T-K4) models
510 (T
-
D2) models (Left bank of dipswitches)
110 (T
-
KJr2) and 310 (T
-
K4) models
Computer board
WARNING
510 (T
-
D2) models Co
mputer board
Left bank of dipswitches
OFF
ON
1 2
3 4
5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6
O
FF
ON
1
2 3 4 5 6
OFF
ON
12345
6
Installation
12Page
Improper venting of this appliance can result in excessive levels of carbon
monoxide which can result in severe personal injury or death.
Improper installation can cause nausea or asphyxiation, severe injury or death from carbon monoxide and flue gases poisoning. Improper installation will void product warranty.
When installing the vent system, all
applicable national and local codes must be
followed. If you install thimbles, fire stops or other protective devices and they penetrate any combustible or noncombustible construction, be sure to follow all applicable national and local codes.
VENTING INSTRUCTIONS
-General-
The water heater must be vented in accordance with the section “Venting of Equipment" of the latest edition of the National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the United States and/or Section 7 of the CAN/CSA B149.1 Natural Gas and Propane Installation Code in Canada, as well as applicable local building codes. The manufacturer recommends the “T-Vent” line manufactured by TAKAGI (Refer to “T-Vent” brochure for details). However, the following are also UL listed manufacturers: ProTech Systems Inc. (FasNSeal), Flex-L Inc., Z-Flex Inc. (Z-Vent III), Metal-Fab Inc., and Heat-Fab Inc. (Saf-T Vent).
General rules for venting water heaters are:
Place the water heater as close as possible to the vent terminator. The vent collar of the water heater must be fastened directly to an unobstructed vent pipe. Do not weld the vent pipe to the water heater’s vent collar. Do not cut the vent collar of the unit. The vent must be easily removable from the top of the water heater for normal service and
inspection of the unit.
The water heater vent must not be connected to any other gas appliance or vent stack. Avoid using an oversized vent pipe or using extremely long runs of the pipe. For rooftop venting, a rain cap or other form of termination that prevents rain water from
entering into the water heater must be installed.
Do not common vent or connect any vent from other appliances to the water heater vent.
General rules for vent terminations:
Avoid locating the water heater vent terminator near any air intake devices. These fans can
pick up the exhaust flue products from the water heater and return them to the building. This can create a health hazard.
Locate the vent terminator so that it cannot be blocked by any debris, at any time. Most
codes require that the terminator be at least 12 inches above grade, but the installer may determine if it should be higher depending on the job site condition and applicable codes.
A proper sidewall terminator is recommended when the water heater is vented through a
sidewall.
Regarding the clearances from the exhaust terminator to the air inlet or opening, refer to
the next few pages.
CAUTION
DANGER
Installation
13Page
-Exhaust venting-
For the 110 Indoor (T-KJr2-IN), 310 Indoor (T-K4-IN) and 510 Indoor
(T-D2-IN) models
This is a Category III appliance and must be vented accordingly. The vent system must be sealed air tight. All seams and joints without gaskets must be sealed with high heat resistant silicone sealant or UL listed aluminum adhesive tape having a minimum temperature rating of 350°F. For best results, a vent system should be as short and straight as possible.
This water heater is a Category III appliance and must be vented accordingly with any 4” vent
approved for use with Category III or Special BH type gas vent.
Follow the vent pipe manufacturer’s instructions when installing the vent pipe. Do not common vent this appliance with any other vented appliance (Do not terminate vent
into a chimney. If the vent must go through the chimney, the vent must run all the way through the chimney with Category III approved or Special BH vent pipe).
When the horizontal vent run exceeds 5 ft., support the vent run at 3 ft. intervals with
overhead hangars.
The maximum length of exhaust vent piping must not exceed 50 ft. (deducting 5 ft. for each
elbow used in the venting system). Do not use more than 5 elbows.
Diameter
Max. No. of Elbow
Max. Vertical
and Horizontal
(Total) Vent
Length
4” 5 50 ft.
*For each elbow added, deduct 5 ft. from max. Vent length.
No. of
Elbows
Max.
Vertical or Horizontal Length
0
50 ft.
1
45 ft.
2
40 ft.
5
25 ft.
-Venting Illustrations-
For the 110 Indoor (T-KJr2-IN), 310 Indoor (T-K4-IN) and 510 Indoor
(T-D2-IN) models
Horizontal Installation Diagram
Vertical Installation Diagram
Sidewall Vent
Terminator
Wall Backflow Preventer*
Vertical Condensation Drain
**
For details of the optional items, refer to the Installation manual for each Optional item.
Roof Vertical Condensation
Drain**
Roof Flashing
Rain Cap
Backflow Preventer *
Installation
14Page
*
Backflow Prevent
er
(Recommended for freezing weather conditions: 36
°F and below)
**Vertical Condensation Drain must be installed accordance with local codes.
Horizontal Installation Diagram With Direct-Vent Concentric Termination
Horizontal Installation Diagram (With direct-venting)
Vertical Installation Diagram (With direct-venting)
The water heater
Intake port of
Direct-Vent Conversion Kit
Installation Diagram of Direct-Vent Conversion Kit with water heater
Wall Direct
-
vent
Concentric Termination
Plate of Direct
-
Vent Conversion Kit
See the picture below for detailed
connection
instructions to the Direct-Vent Conversion Kit.
Vertical Condensation Drain
**
Backflow
Preventer *
Wall Sidewall
Vent Terminator
Roof Flashing
Vertical
Condensation Drain**
Backflow
Preventer *
Rain Cap
Roof Fire stop
Installation
15Page
-Vent termination clearances-
Canada
U.S.A
Direct vent and
other than Direct
Vent
Direct vent Other than Direct Vent
A
Clearance above grade, veranda, porch, deck,
or balcony.
1 foot 1 foot 1 foot
B
Clearance to window or door that may be opened.
3 feet 1 foot
4 feet from below or side
opening. 1 foot from
above opening.
C Clearance to permanently closed window
* * * D
Vertical clearance to ventilated soffit located
above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line
of the terminator.
* * *
E Clearance to unventilated soffit
* * * F
Clearance to outside corner
* * * G
Clearance to inside corner
* * * H
Clearance to each side of center line extended
abo
ve meter/regulator assembly
3 feet * *
I Clearance to service regulator vent outlet.
3 feet
* * J Clearance to non
-
mechanical air supply inlet
to building or the combustion air inlet to any
other application.
3 feet 1 foot
4 feet from below or side
opening. 1 foot from
above opening.
K Clearance to mechanical air supply inlet.
6 feet
3 feet
3 feet
L Clearance above paved sidewalk or paved
driveway located on public property.
7 feet * 7 feet
M
Clearance under veranda, porch deck, or
balcony.
1 foot * *
*For clearances not specified in ANSI Z223.1 / NFPA 54 or CAN/CSA
-
B149.1, please use clearances in accordance with
local installation codes and the requirements of the gas supplier.
Installation
16Page
Please follow all
local and national codes in regards to proper termination clearances.
In the absence of such codes, the following clearances can be used as guidelines. Local codes supersede these guidelines.
For sidewall terminations
Exhaust termination
1ft.
1ft. 2ft.
Inside
corner
For multiple sidewall exhaust
terminations (e.g. multi-unit systems), an exhaust termination must be at least 1 ft. away from another exhaust termination. An exhaust termination must also be at least 2 ft. away from an inside corner (if the adjacent wall is less than 2 ft. of length, the minimum required distance away from the inside corner will be equal to the length of that adjacent wall).
For direct
-
vent sidewall
terminations that use two separate penetrations for the intake and exhaust, distance the intake and exhaust terminations at least 3 ft. away from each other, no matter the orientation.
For multiple
-
unit, direct
-
vent sidewall
terminations that combine the intake and exhaust into a single penetration, space each direct-vent termination at least 1 ft. away from each other, no matter the orientation. A direct-vent termination must also be at least 2 ft. away from an inside corner (if the adjacent wall is less than 2 ft. of length, the minimum required distance away from the inside corner will be equal to the length of that adjacent wall).
For mul
tiple-unit rooftop terminations (whether for standard indoor or
direct-vent installations) space all exhaust and intake terminations in accordance with local codes. An exhaust termination must be spaced from a wall or surface in accordance with local codes as well. In the absence of such a code, an exhaust termination must be a horizontal distance of at least 2 ft. away from a wall or surface.
A: In accordance with local codes
For rooftop terminations
Air intake
Exhaust
termination
A
A
A
A
A
2ft.
Air intake
Exhaust
termination
Exhaust and/or d
irect-vent
sidewall terminations should be at least 2 ft. away from an opposite surface/wall. Do not place the termination directly in front of an opening into a building.
2ft.
Exhaust
termination
Air supply inlet
3ft.
3ft.
3ft.
Direct vent termination
1ft.
1ft.
Inside
corner
2ft.
CAUTION
Installation
17Page
Size the gas pipe appropriately to supply the necessary volume of gas required for the water heater using ANSI233.1/NFPA 54 in the USA or CAN/CSA B149.1 in Canada or local codes. Otherwise, flow capabilities and output temperatures will be limited.
Check that the type of gas matches the rating plate first.
Ensure that any and all gas regulators used are operating properly and
providing gas pressures within the specified range shown below. Excess gas inlet pressure may cause serious accidents.
Conversion of this unit from natural gas to propane or vise versa will void all
warranty. Contact your local distributor to get the correct unit for your gas type. The manufacturer is not liable for any property and/or personal
damage resulting from gas conversions.
GAS SUPPLY AND GAS PIPE SIZING
-General-
The minimum and maximum inlet gas pressures are:
Gas type
Inlet gas pressure
Natural Gas
Min. 5.0
” WC –
Max. 10.5
” WC Propane
Min. 8.0
” WC –
Max. 14.0
” WC
Gas pressure above this specified range for the water heater and/or insufficient gas volume will
adversely affect performance. These pressures are measured when the water heater is in full operation.
Inlet gas pressure must not exceed the above maximum values; gas pressure above the specified
range will cause dangerous operating conditions and damage to the unit.
Until testing of the main gas line supply pressure is completed, ensure the gas line to the water
heater is disconnected to avoid any damage to the water heater.
-Gas connections-
1. Install a manual gas shut-off valve between the water heater and the gas supply line.
2. When the gas connections are completed, it is necessary to perform a gas leak test (see below)
either by applying soapy water to all gas fittings and observing for bubbles or by using a gas leak detection device.
The water heater and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The water heater must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).
3. Always purge the gas line of any debris and/or water before connecting to the gas inlet.
WARNING
NOTICE
Installation
18Page
-Natural Gas Supply Piping-
Maximum Delivery Capacity of Cubic Feet of Gas per Hour of IPS Pipe Carrying Natural Gas of 0.60 Specific Gravity Based on Pressure Drop of 0.5” WC
Based on Energy Content of 1,000 BTU/Cubic Ft.: The water heater requires 140 Cubic Ft./hr for the 110 (T-KJr2) models, 190 Cubic Ft./hr for the 310 (T-K4) models, and 199 Cubic Ft./hr for the 510 (T-D2) models.
Unit: Cubic Feet per Hour
Pipe Size
Length
Diameter
10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’ 125’ 150’ 200’ ¾” 363 249 200 171 152 138 127 118 111 104 93 84 72 1” 684 470 377 323 286 259 239 222 208 197 174 158 135 1 ¼” 1,404 965 775 663 588 532 490 456 428 404 358 324 278
1 ½” 2,103 1,445 1,161 993 880 798 734 683 641 605 536 486 416 2” 4,050 2,784 2,235 1,913 1,696 1,536 1,413 1,315 1,234 1,165 1,033 936 801
-Propane (LP) Supply Piping-
Maximum Capacity of Propane (LP) Based on 11” WC supply pressure at a 0.5” WC pressure drop
Unit: kBTU per Hour
Pipe Size
Length
Diameter
10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’ 125’ 150’ 200’ ¾” 567 393 315 267 237
217 196 185 173 162 146 132 112 1” 1,071
732 590 504 448 409 378 346 322 307 275 252 213 1 ¼” 2,205 1,496
1,212
1,039
913 834 771 724 677 630 567 511 440 1 ½” 3,307 2,
299 1,858 1,559
1,417
1,275
1,181
1,086
1,023
976 866 787 675 2” 6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496
1,260
For more information, please see the below.
Based on Energy Conten
t of 1,000BTU/Cubic Ft:
Divide each appliance’s BTU requirement by 1,000BTU to get the appliances Cubic Ft. requirement.
Take into account the distance the appliance is from the gas meter, look in the above gas chart to properly size the line.
For sections of the gas line supplying gas to more than one appliance (Ex: Point A to Point B), add up the cubic ft. requirements of the appliances that are being supplied by that section, and size to the farthest appliance.
For Example: The section from A to B supplies gas to the furnace, range, and dryer. Adding up the BTU requirements and dividing by 1,000 yields a cubic ft. requirement of 220 cubic ft. of gas. The farthest appliance is the range, which is 50 ft. away from the meter. Looking at the above chart, and under the column of 50ft., Section A to B needs to be 1” in order to supply 220 cubic ft.
10’ Lengt
h
1” Pipe Size
C
Gas Sizing Example
(Natural Gas)
10’ Length
3/4” Pipe Size
15’ Length
1/2” Pipe Size
10’ Length
1/2” Pipe Size
Furnace
120,000BTU
Water
Heater
199,000BTU
5’ Length
1-1/4” Pipe Size
Range
65,000BTU
10’ Length
3/4” Pipe Size
Dryer
35,000BTU
15’ Length
1” Pipe Size
5’ Length
1-1/4” Pipe Size
Gas Meter
B
A
Installation
19Page
1. Turn off
all electric power to the water heater if serv
ice is to be performed.
2. Turn the manual gas valve located on the outside of the unit clockwise to
the off position.
-Measuring inlet gas pressure-
The water heater cannot perform properly without sufficient inlet gas pressure. Below are instructions on how to check the inlet gas pressure. THIS IS ONLY TO BE DONE BY A LICENSED PROFESSIONAL.
1. Shut off the manual gas valve on the supply gas line.
2. Remove the screw for the pressure port located on
the gas inlet of the water heater shown in the diagram to the right.
3. Connect the manometer to the pressure port.
4. Re-open the manual gas valve. Check to see that
there are no gas leaks. Open some of the fixtures that use the highest flow rate to turn on the water heater.
5. Check the inlet gas pressure. When the water heater
is on maximum burn, the manometer should read from 5.0” to 10.5” WC for Natural gas, from 8.0” to
14.0” WC for Propane.
Pressure port
Installation
20Page
Do not use this water heater if any part has been submersed under water.
Immediately call a licensed professional to inspect the water heater to replace any damaged parts.
Do not reverse the hot outlet and cold inlet connections to the water heater.
This will not properly activate the water heater.
WATER CONNECTIONS
All pipes, pipe fittings, valves and other components, including soldering materials, must be suitable for potable water systems.
1. A manual shut off valve must be installed on the cold water inlet to the water heater between
the main water supply line and the water heater.
2. In addition, a manual shut off valve is also
recommended on the hot water outlet of the unit. If the water heater is installed within, or subjected to, a closed loop water system, a thermal expansion tank must be installed.
3. Before installing the water heater, flush the
water line to remove all debris, and after installation is complete, purge the air from the line. Failure to do so may cause damage to the heater.
4. There is a wire mesh filter within the cold inlet
to trap debris from entering your heater. This will need to be cleaned periodically to maintain optimum flow.
-Pressure relief valve-
The water heater has a high-temperature shut off switch built in as a standard safety feature (called a Hi-Limit switch) therefore a “pressure only” relief valve is required.
This unit does not come with an approved pressure relief valve. An approved pressure relief valve must be installed on the hot water outlet. The pressure relief valve must conform to ANSI Z21.22 or CAN 1-4.4 and installation must follow
local code.
The discharge capacity must be at least 140,000 BTU/h for the 110 (T-KJr2) models, 190,000
BTU/h for the 310 (T-K4) models, and 199,000 BTU/h for the 510 (T-D2) models.
The pressure relief valve needs to be rated for a maximum of 150 psi. The discharge piping for the pressure relief valve must be directed so that the hot water cannot
splash on anyone or on nearby equipment.
Attach the discharge tube to the pressure relief valve and run the end of the tube to within 6"
from the floor. This discharge tube must allow free and complete drainage without any restrictions.
If the pressure relief valve installed on the water heater discharges periodically, this may be due
to a defective thermal expansion tank or defective pressure relief valve.
The pressure relief valve must be manually operated periodically to check for correct operation. No valve must be placed between the relief valve and the water heater.
Pressure
Relief Valve
Hot
outlet
Cold
inlet
Gas
inlet
As Close as
Possibl
e
CAUTION
Installation
21Page
Follow the electrical code requirements of the local authority having jurisdiction. In the absence of such requirements, follow the latest edition of the National Electrical Code ANSI/NFPA 70 in the U.S. or the latest edition of CSA C22.1 Canadian Electrical Code, Part 1, in Canada.
When servicing
or replacing p
arts within the
water heater
, label all wires
prior to disconnection to facilitate an easy and error-free reconnection. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
ELECTRICAL CONNECTIONS
1. The water heater must be electrically grounded. Do not attach the ground wire to either the gas or
the water piping.
2. The water heater requires 120 VAC / 60 Hz electrical power supply that is properly grounded.
A proper disconnect (i.e. on/off switch, power plug, etc.) controlling the main power to the
water heater must be provided for service reasons. (Must comply with local codes).
Connect the power supply to the water heater exactly as shown in the wiring diagram;
3. A green screw is provided in the junction box to ground the connection.
4. Can be hardwired or wired to a plug-in.
5. The use of a surge protector is recommended in order to protect the unit from power surges.
CAUTION
WARNING
Connect Power supply
120 V
AC / 60 Hz
Ground
Bottom view of water heater
View of e
lectrical
connections of water heater
Green screw
Installation
22Page
REMOTE CONTROLLER CONNECTIONS
<How to connect the remote controller to the water heater>
1. Disconnect power supply from the water heater.
2. Take off the water heater’s front cover.
3. Locate the remote controller terminal, pictured below (located around the lower right-hand
side of the computer board).
4. Open the plastic cover of the remote controller, and then attach the two fork terminals to
connector base of the backside the remote controller with two screws. Make sure the terminals are firmly fixed.
5. Pull the remote’s wires through the hole at the bottom of the water heater’s casing.
6. Properly attach the remote’s wires to the remote controller terminal on the computer board.
(No polarity)
*Do NOT jump or short-circuit the wires or computer will be damaged.
7. Replace Front Cover securely.
8. Wires used for the remote controller connection must be:
Minimum 18AWG wire (No polarity) Maximum 400 feet long
*For detail
ed
connection
instructions
to the
remote controller
, refer to the
instructions that ar
e
packaged with the remote controller.
510 (T
-
D2) models
110 (T
-
KJr2) and 310 (T
-
K4) models
Front of remote
Back of remote
Connect other end to these terminals
Connect to these
terminals
9007666005 (TK-RE02)
Front of remote
Back of remote
Connect other end to these terminals
Connect to these
terminals
9007603005 (TM-RE30)
Installation
23Page
In an Easy-Link system, the pump must be connected to the “Pump” connector in the “PARENT” unit only. If the pump is connected to any of the “CHILD” units, the
pump will not work.
PUMP CONTROL CONNECTIONS
Available on the 510 (T-D2) models only
The 510 (T-D2) models water heaters can be used to control a recirculation pump. Proper pump control helps to preserve the life of the system and saves energy as well.
The water heater pump control port is a “normally open dry contact”, and therefore needs additional components to properly control a recirculation pump. To control a recirculation pump, connect the pump to the “Pump” connector in the water heater as shown in the diagram below. (In an Easy-Link system, connect the pump ONLY to the “PARENT” unit.) The pump is to be connected using suitable relays shown in the diagram below. Please make sure the relays are properly rated for the recirculation pump. Using the water heater’s internal thermistors as a temperature control, the recirculation pump will only turn on when recirculation is needed.
CAUTION
These components are
NOT in
cluded wit
h
the water heater
and
are
external to the unit. They must be acquired separately.
Connect to
this “Pump
connector”.
Recirculation
pump
Thermal
relay
120 VAC
220 VAC etc for relay
Power supply
for pump 120 VAC 220 VAC etc
Power supply
for relay
Installation
24Page
The Easy-Link system is limited up to 4 units. If you connect more than 4 units,
only the first 4 units will work as a part of the Easy-Link system. The other additional units will not work.
All units within an Easy-Link System must be of the same exact model.
Different models cannot combine together to form an Easy-Link System.
EASY-LINK SYSTEM
Available on the 510 (T-D2) models only
-General-
The 510 (T-D2) models water heaters can be connected with other heaters of the same model with communication cables to work as a multiple-unit manifold system.
The Easy-Link system allows up to 4 units to manifold together. A communication cable (gray color) comes with each 510 (T-D2) models.
You can manifold from 2 to 4 units without the need for a multi-system controller. A 4-unit system has full automatic modulation between 11,000 BTU/h and 796,000 BTU/h.
-Easy-Link Connection Procedures-
1. Verify the set temperatures of all units within the system. Every single water heater must be set to the same set temperature.
2. Select one unit to be the “PARENT” unit.
3. “PARENT” unit
Locate the two banks of dipswitches to the right of the 7-seg. LED on the computer board of the unit that you select to be the “PARENT” unit. Change dipswitch No. 1 on the right bank of dipswitches to the ON position. See the computer board diagram as shown in the next page. Do not change any dipswitches on any of the “CHILD” units.
Hot
Out
Cold
In
Gas
In
CAUTION
Installation
25Page
The dark sq
uares indicate the direction the dipswitches should be set to.
4. Between the “PARENT” and the “CHILD-1” units
Connect the “PARENT” connector of the “PARENT” unit to the “[1]” connector of the “CHILD-1” unit.
5. Between the “CHILD-1” and the “CHILD-2” units
Connect the “[2]” connector of the “CHILD-1” unit to the “[1]” connector of the “CHILD-2” unit.
6. Between the “CHILD-2” and the “CHILD-3” units
Connect the “[2]” connector of the “CHILD-2” unit to the “[1]” connector of the “CHILD-3” unit.
7. Make sure the 7-seg. LED of all the units’ computer boards display the unit #. The numbering system automatically allocates the unit # to each water heater in the Easy-Link system, in accordance with the table below.
Parent
unit Unit # : 1
Child
units
Unit # : 2, 3 and 4
(A) 510 (T
-
D2) models Computer board
(B) Ba
sic diagram of connections between the Easy
-
Link System units.
To change the dipswitch
settings for the Easy-Link system, locate the bank of dipswitches to the right of the 7-seg LED.
Do not adjust the left bank of dipswitches.
Easy-Link connectors are next to the
computer board
.
Easy-Link system
“Online” LED
Right bank of
dipswitches
Left bank of
dipswitches
7-Seg. LED
CAUTION
P A R E N T
1 234 5 6
Communication c able
Co n n e c t or s
Right bank of Dipswi tches
OFF
ON
OFF
ON
OFF
ON
OFF
ON
11
11
11
11
22
22
22
22
P A R E N T
P A R E N T
P A R E N T
1 234 5 6
Right bank of Dipswi tches
1 234 5 6
Right bank of Dipswitches
1 234 5 6
Right bank of Dipswitches
Co n n e c t or s Co n n e c t or s Co n n e ct o r s
PARENT unit CHILD
-
1 unit
CHILD
-
2 unit
CHILD
-
3 unit
Installation
26Page
A remote controller is not required for the Easy-Link system. If running the Easy-Link system without a remote controller, please make sure the
temperature settings on ALL the units are set to the same settings. Otherwise, the units will not operate properly.
If a remote controller is used, the temperature on all the units in the system will
automatically be set to the same temperature that is set on the remo
te.
CASE 1:
Unless you change dipswitch No.1 of the “PARENT” unit to the “ON” position, the
system will not work as an Easy-Link system. The units will operate as individual units.
CASE 2:
If you connect the “[1] (or [2])” connector of the “PARENT” unit to the PARENT (or [1])
connector of the “CHILD-1” unit, the system will not work as an Easy-link system. The units will operate as individual units.
Wrong dipswitch setting on the “PARENT” unit
Wrong connections between the “PARENT” unit and the “CHILD-1” unit
(C) Example
s of incorrect settings and/or connections
Prohibited
Prohibited
NOTICE
OR
W
rong S
etting
PARENT
unit CHILD
-
1 unit
Communication cable
OFF
ON
OFF
ON
212 1
212 1
P A R E N T
P A R E N T
Co n n ec t o r s C on n ec t o r s
1 2 3 4 5 6 1 2 3 4 5 6
Right bank of Dipsw itchesRight bank of Dipswitche s
Communication cable
OFF
ON
OFF
ON
212 1
212 1
P A R E N T
P A R E N T
Co n n e ct o r s Con n e c to r s
1 2 3 4 5 6
Right bank of Dipsw itches
1 2 3 4 5 6
Right bank of Dipsw itches
Wrong
Connections
PARENT
unit CHILD
-
1 unit
Communication cable
OFF
ON
OFF
ON
212 1
212 1
P A R E N T
P A R E N T
1
2 3 4 5 6
Right bank of Dips witches
1
2 3 4 5 6
Right bank of Dip switches
Co n n ec t o rsCo n n ec t o rs
Wrong
Connections
PARENT
unit CHILD
-
1 unit
Installation
27Page
Con
necting two “
PARENT
” connectors together from two separate units
may damage
the computer board. The communication cable has a female end and a male end so
it’s impossible to have a PARENT -to- PARENT connection with the communication cable. Do not splice or modify connectors.
Communication c able
OFF
ON
OFF
ON
OFF
ON
212 1
212 1
212 1
P A R E N T
P A R E N T
P A R E N T
Co n n e c to r s Co n n ec t o rs Con n e c to r s
1 2 3 4 5 6
Right bank of Dipsw itches
1 2 3 4 5 6
Right bank of Dip switches
1 2 3 4 5 6
Right bank of Dips witches
CASE 3:
If you connect the “PARENT” connector of the “CHILD-1” unit to the “[1]” connector of the
“CHILD-2” unit, the “CHILD-2” unit will operate as an individual unit, and will not be part of the
Easy-Link system.
CASE 4:
If a remote controller (optional) is used, it has to be connected to the “PARENT” unit. If the
remote controller is connected to a “CHILD” unit,
it will only control that particular individual
CHILD” unit and will not control the Easy-Link system as a whole.
Wrong connections between the “CHILD-1” unit and the “CHILD-2” unit
Remote controller connected to incorrect unit
WARNING
Prohibited
Prohibited
Wrong Connections
PARENT
unit
CHILD unit
Remote controller
Communicatio n cable
OFF
ON
OFF
ON
212 1
212 1
P A R E N T
P A R E N T
Co n n ec t o rs Co nn e c to r s
1 2 3 4 5 6
Right b ank of Dipswitc hes
1 2 3 4 5 6
Right b ank of Dipswitc hes
Wrong
Connections
PARENT
unit CHILD
-
1 unit
CHILD
-
2 unit
Installation
28Page
In order to purge air in water pipes within a closed-loop system, an air vent
and air separator should be installed in to the system. Required circulation flow rates are labeled next to each application diagram. These flow rate requirements must be followed.
Toxic chemicals used in boiler treatments such as alcohol, glycerol and glycol
groups must not be introduced into the system if the system incorporates an open-loop potable water system.
The water heater can be used to supply potable water and space heating and
shall not be connected to any heating system or component(s) previously used with non-potable water where any chemicals were added to the water heating appliances.
When the system requires water for space heating at temperatures higher
than required for other uses, a means such as a mixing valve shall be installed to temper the water for those other uses in order to reduce scald hazard potential.
Water temperature over 125 F (52°C) can cause severe burns instantly or
death from scalds.
Chemicals such as diluted Glycol can be used for radiant floor, Hydro/fan coil
air or Baseboard heating only. The diluted solution of glycol must contain between 25 and 55 % of Glycol. Be aware that in closed-loop glycol systems, low pressure in the heat exchanger can cause low-temperature boiling, resulting in excessive noise and damage to the water heater. Consult with the glycol maker for specifications prior to use.
This is a concept drawing only.
APPLICATIONS
-Space-Heating Applications-
* The
recirculation pump is to be controlled by:
-Dual-set aquastat (recommended w/timer) OR
-“Pump Control Connections” 510 (T-D2) models only.
Refer to p. 23. * The recirculation pump is to provide no less than 2 GPM and no more than 4 GPM through each activated unit in the system.
-Recirculation-
WARNING
Check valve
Check valve
Air
separator
Recirculation
pump
Hot water outlet to
fixtures
Air Vent
Unions
Gas supply
Ball v
alves Expansion tank
Y-
Strainer
Cold water
inlet
Hot Wate r Outl et
S
Cold Wate r Inle t
Gas Inle t
Installation
29Page
-Dual-purpose hot water heating­(Domestic and Space Heating):
Priority Control Devices such as a flow switch, an Aquastat or other electronic
controller can be used to prioritize the domestic water system over the heating system.
Follow all local codes, or in the absence of local codes, follow the most recent
edition of the National Standard Code, ANSI Z21.10.3.
This illustration is a concept design only. The reference to the 1/8
th
hole in check is only for the State of Massachusetts. There are a wide variety of variations to the application of controls and equipment presented. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practice. For more details, contact the manufacturer.
NOTICE
*
The circulation pump is to provide no less
than 2 GPM
and no more than 4 GPM
throug
h eac
h activated
unit in the system.
Takagi
P
T
An approved Pressure Only
Relief Valve, Tie to Location
approved by Local Codes and Must Meet BTU Rating of Takagi Model Used
Unions
4" Gas Exhaust Vent (Discharge Must Comply with Local and State Codes). Can Not Be Common Vented with Other Appliances
Atmospheric Vacuum Breaker
Pump (Must Be Sized Properly With Each Application). Pump Shall Run 60 Seconds Every 6
Hours
Pressure
Gauge
Apply Correct Thermal Expansion Tank-Size Per Application
Tempered Water To House
Cold Inlet
Shut-Off
Valve
Check Valve Will Have 1/8" Hole in Check, As Per Mass. Code
Thermometer
Thermostatic Mixing Valve
Shut-Off Valves
Check Valve
Hot
Water
Outlet
Cold Water Inlet
T-Handle Gas Shut-Off Valve
**Maximum allowable distance of 50-Ft. from water heater and heating panel
Heating Coil
(used with air-handler)
Diagramatic Layout of Radiant Heating and
Domestic Water Heater Per Mass. Code
Thermometer
Check Valves
Gas Inlet
Drain Plug
Water
Filter
120 VAC Switch or Outlet
**Maximum allowab le
distance of 50 ft. from water heater and heating panel
An approved Pressure Only Relied
Valve, Tie to Location approved By Local Codes and Must Meet BTU Rating of water he ater Model Used
Initial Operation
30Page
Check the GAS and WATER CONNECTIONS for leaks before firing unit for the first time. Open the main gas supply valve to the unit using only your hand to avoid any spark. Never use
tools. If the knob will not turn by hand, do not try to force it; call a qualified service technician. Forced repair may result in a fire or explosion due to gas leaks.
Be sure to check for the presence of leaking gas toward the bottom of the unit because some
gases are heavier than air and may settle towards the floor.
Check the GAS PRESSURE. Refer to p. 19. Do not try to light the burner manually. It is equipped with an electronic ignition device which
automatically lights the burner.
Check for PROPER VENTING and COMBUSTIBLE AIR to the water heater. Purge the GAS and WATER LINES to remove any air pockets. Do not use this water heater if any part has been submersed under water. Immediately call a
qualified service technician to inspect the water heater and to replace any damaged parts.
INITIAL OPERATION
1. Once the above checks
have been completed, please clean filter of any debris. Refer to p. 36 for instructions.
2. Fully open the manual
water control valve on the water supply line.
3. Open a hot water tap to
verify that water is flowing to that tap.
Then close the hot water tap.
4. Fully open the manual gas
control valve installed.
5. Turn on the 120 volt 60 Hz
power supply to the water heater.
6. Now you are ready to
enjoy hours of endless hot water.
FOR YOUR SAFETY, READ BEFORE OPERATING
IF YOU SMELL GAS:
Do not try to start the water heater. Do not touch any electric switches; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
WARNING
Operating Safety
31Page
OPERATING SAFETY
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This water heater does not have a pilot. It is equipped with an ignition device that
automatically lights the burner. Do not
try to light the burner by hand.
B. BEFORE OPERATING smell all around the water heater area for evidence of leaking gas. Be
sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS.
Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to turn the gas valve knob. Never use tools. If the knob will not turn by
hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire of explosion.
D. Do not use this water heater if any part has been under water. Immediately call a qualified
service technician to inspect the water heater and to replace any damaged parts.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above or in the Owners Manual.
2. Turn off all electric power to the water heater.
3. Do not attempt to light the burner by hand.
4. Turn the manual gas valve located on the outside of the unit clockwise to the off position.
5. Wait five (5) minutes to clear out any gas. If you then smell gas. STOP! Follow "B" in the safety
information above on this label. If you don't smell gas, go to next step.
6. Turn the manual gas valve located on the outside of the unit counter clockwise to the ON
position.
7. Turn on all electrical power to the water heater.
8. If the water heater will not operate, follow the instructions “to Turn Off Gas to water heater"
and Call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Turn off all electric power to the water heater if service is to be performed.
2. Turn the manual gas valve located on the outside of the unit clockwise to the off position.
O
O
O
w
w
w
n
n
n
e
e
e
r
r
r
s
s
s
G
G
G
u
u
u
i
i
i
d
d
d
e
e
e
Operating Safety
32Page
DANGER
Vapors from flammable liquids will explode and catch fire causing death or severe burns.
Do not use or store flammable products such as gasoline, solvents or adhesives in the same room or area near the water heater.
Keep flammable products:
1. Far away from heater
2. In approved containers
3. Tightly closed
4. Out of children's reach
Vapors:
1. Cannot be seen
2. Vapors are heavier than air
3. Go a long way on the floor
4. Can be carried from other rooms to the main
burner by air currents
WARNING: Do not install water heater where flammable products will be stored.
Read and follow water heater warnings and instructions. If owner’s manual is missing, contact the manufacturer.
WARNING
The outlet hot water temperature of the water heater is factory set at 122°F (50°C). Use this heater at your own risk. The set outlet water temperature can cause severe burns instantly or death from scalds. Test the water before bathing or showering. Do not leave children or an infirm person in the bath unsupervised.
DANGER
Hot Water temperature over 125°F (52°C) can cause severe burns instantly or death from scalding. Children, disabled and elderly are at the highest risk of being scalded. Feel water temperature before bathing or showering. Temperature limiting valves are available. Ask a professional person.
WARNING: California Proposition 65 lists chemical substances known to the state to cause cancer, birth defects, death, serious illness or other reproductive harm. This product may contain such substances, be their origin from fuel combustion (gas, oil) or components of the product itself.
Normal Operation
33Page
Flow rate to activate the water heater : 0.5 gallons per minute at the
default set temperature
Flow rate to keep the water heater running : 0.4 gallon per minute
Hot Water temperatures over 125F (52°C) can cause severe burns instantly or
death from scalding.
The outlet hot water temperature of the water heater is factory
set at 122°F (50°C).
Feel the water temperature before bathing or showering.
NORMAL OPERATION
GENERAL
1.
Open a hot water tap.
*
2.
Mix cold water with the hot to get
the correct temperature water.
3.
Close the hot water tap.
*If a remote controller installed, turn the remote controller ON by pressing the power ON/OFF button
on the remote controller and then set the temperature by pressing the HOT/COLD buttons before opening a hot water tap. The temperature is displayed when the remote controller is turned ON.
TEMPERATURE SETTINGS
-Without remote controller-
Depending on the model, there are 4 or 8 temperatures that you can select from by changing the dipswitch settings on the computer board without the remote controller. See the table below.
Model
Temperatures available
110 (
T-KJr2)
310 (T-K4)
113F 122F 131F 140F
510 (T-D2)
104F 113F 122F 131F 140F 158F 176F 185F
For detailed dipswitch settings for each temperature, refer to the next page.
The temperature has been preset at the factory to 122°F (50°C). If temperatures other than the ones listed above are required, the remote controller can
provide several more temperature options. Refer to p. 9 for a list of available temperatures on the remote controller.
This water heater is an on-demand, tankless water heater designed to efficiently supply
endless hot water without reference to temperature settings.
NOTICE
WARNI
NG
Normal Operation
34Page
DO NOT set to 185 °F if you use your water heater in a recirculation
system. This will cause damage to the heater and void the warranty. (This temperature setting is only available on the 510 (T-D2) models.)
DO NOT adjust the left bank of dipswitches. For the 510 (T-D2) models. Turn off the power supply to the water heater before changing the
dipswitch settings.
Only change the switches with the dark squares. The dark squares indicate
which direction the dipswitch should be set to.
510 (T
-
D2) models
110 (T
-
KJr2) and 310 (T
-
K4) models
510 (T
-
D2) models
110 (T
-
KJr2) and 310 (T
-
K4) models
Location of the bank of dipswitches on the c
omputer board
WARNING
Dipswitches
Right bank of
dipswi
tches
Left bank of
dipswitches
7-Seg. LED
-
Dipswitch settings for each temperature on the computer board
-
(45
OFF
ON
C)
113 F
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
(50 C)
122 F
DEFAULT
(55
OFF
ON
C)
131 F
1 2 3 4 5 6 7 8
(60
OFF
ON
C)
140 F
1 2 3 4 5 6 7 8
Temperature Settings
Temperature Settings
<Right bank of dipswitches>
(45 C)
113 F
(40
OFF
ON
C)
104 F
(70 C)
158 F
(60 C)
140 F
(85 C)
185 F
(80 C)
176 F
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
OFF
ON
1 2 3 4 5 6
(45 C)
113 F
OFF
ON
1 2 3 4 5 6
(50 C)
122 F
DEFAULT
OFF
ON
1 2 3 4 5 6
(55 C)
131 F
OFF
ON
1 2 3 4 5 6
Normal Operation
35Page
Only pipes within
the water heater are protected by the freeze protection
system. Any water pipes (hot or cold) located outside the unit will not be protected. Properly protect and insulate these pipes from freezing.
Household Flow Rates
Taken from UPC 2006
FLOW
The flow rate through the water heater is limited to a
maximum of 6.6 GPM for the 110 (T-KJr2) models, 8.0 GPM for the 310 (T-K4) models, and 10.0 GPM for the 510 (T-D2) models.
The temperature setting, along with the supply
temperature of the water will determine the flow rate output of the unit.
Please refer to the temperature vs. gallons per minute
chart on p. 48-49 to determine the likely flow rates based on your local ground water temperature and your desired outlet water temperature.
Based on the United States Department of Energy method of testing water heater output, the water
heater is rated for gallons per hour (GPH) or gallons per minute (GPM) for Natural Gas and Propane, when raising the water temperature by 77F (from 58F to 135F). See the diagram below.
Refer to the table to the top right for typical household plumbing fixture flow rates to determine
what the water heater can do in a household application.
FREEZE PROTECTION SYSTEM
This unit comes equipped with heating blocks to protect it against damages associated with freezing. For this freeze protection system to operate there has to be electrical power to the unit. Damage to
the heat exchanger caused by freezing temperatures due to power loss is not covered under the warranty. In cases where power losses can occur, consider the use of a backup power supply.
The freeze protection system will activate when the surrounding and/or outside temperatures drop
below 36.5°F (2.5°C).
For the 110 Indoor (T-KJr2-IN), 310 Indoor (T-K4-IN) and 510 Indoor (T-D2-IN) models:
In any areas subject to freezing temperatures, the manufacturer highly recommends an
indoor installation with an indoor model. In such an installation, freezing issues can only occur if cold air enters through the venting into the heat exchanger, whether by negative pressures within the installation location or by strong outside winds.
The manufacturer also highly recommends the use of a back flow vent damper to minimize
the amount of cold air entering through the exhaust venting when the water heater is off.
 It is the installer’s responsibility to be aware of freezing issues and take all preventative measures.
The manufacturer will not be responsible for any damage to the heat exchanger as a result of freezing.
If you will not be using your heater for a long period of time:
1. Completely drain the unit of water. Refer to p. 36.
2. Disconnect power to your heater.
This will keep your unit from freezing and being damaged.
Appliance / Use
Flow R
ate (GPM)
Lavatory Faucet
1.0 Bath Tub
4.0 –
10.0 Shower
2.0 Kitchen Si
nk
1.5 Dishwasher
1.5 Washing machine
4.0
Model
110 Indoor
(T-KJr2-IN)
110 Outdoor
(T-KJr2-OS)
310 Indoor
(T-K4-IN)
310 Outdoor
(T-K4-OS)
510 Indoor
(T-D2-IN)
51
0 Outdoor
(T-D2-OS)
GPH GPM
GPH GPM
GPH GPM
GPH GPM
GPH GPM
GPH GPM
Natural Gas
172 2.9 180
3.0 244 4.1 242 4.0 254 4.2 255 4.3 Propane
184 3.1 179
3.0 250 4.2 249 4.2 256 4.3 255 4.3
CAUTION
Normal Operation
36Page
Turn off the electrical power supply and close the manual gas shutoff valve and the manual water control valve before servicing.
MAINTENANCE AND SERVICE
Clean the cold-water inlet filter. (Refer to diagram below) Be sure that all openings for combustion and ventilation air are not blocked. The venting system should be checked annually for any leaks, corrosion, blockages or damage. The burner should be checked annually for dust, lint, grease or dirt. Keep the area around the water heater clear. Remove any combustible materials, gasoline or any
flammable vapors and liquids.
In accordance with all local codes and common safety practices, Water discharged from the pressure
relief vale can cause severe burns instantly from scalding. DO NOT touch the pressure relief valve.
If the relief valve discharges periodically, it may be due to thermal expansion in a closed water supply
system. Contact the water supplier or local plumbing inspector on how to correct this situation.
Visual check of burner flames (see below) through the burner window in the burner assembly located
at the middle of the water heater.
The manufacturer recommends having the unit checked once a year or as necessary by a licensed technician. If repairs are needed, any repairs should be done by a licensed technician.
UNIT DRAINING and FILTER CLEANING
1. Close the manual gas shut off valve.
2. Turn off power to the unit and wait a couple of
seconds. Turn on again.
3. Wait 30 seconds, and then turn off power to the unit,
yet again.
4. Close the water shut off valve.
5. Open all hot water taps in the house. When the
residual water flow has ceased, close all hot water taps.
6. Have a bucket or pan to catch the water from the
unit’s drain plugs. Unscrew
the two drain plugs (Large
and small) to drain all the water out of the unit.
7. Wait a few minutes to ensure all water has
completely drained from unit.
8. Clean the filter: Check the water filter located within
the cold inlet. With a tiny brush, clean the water filter of any debris which may have accumulated and reinsert the filter back into the cold water inlet.
9. Securely screw the drain plugs back into place. Hand-
tighten only.
WARNING
Drain Plug
with Filter (Large)
Water Valve
Drain Plu
g
(Small)
Gas Valve
Unsatisfactory
Satisfactory
Unsatisfactory
Blue flame
Red or Yellow
flame
F
lame
blowing up
Troubleshooting
37Page
GENERAL
TROUBLESHOOTING
-TEMPERATURE and AMOUNT OF HOT WATER-
PROBLEM SOLUTIONS
It takes long time to get hot water at the fixtures.
The time it takes to deliver hot water from the water heater to
your fixtures depends on the length of piping between the two. The longer the distance or the bigger the pipes, the longer it will take to get hot water.
If you would like to receive hot water to your fixtures quicker, you
may want to consider a hot water recirculation system. (p. 28)
The water is not hot enough.
Compare the flow and temperature. See the charts on p. 48-49. Check cross plumbing between cold water lines and hot water
lines.
Is the gas supply valve fully open? (p. 30) Is the gas line sized properly? (p. 18) Is the gas supply pressure enough? (p. 19) Is the set temperature set too low? (p. 33-34)
The water is too hot.
Is the set temperature set too high? (p. 33-34)
The hot water is not available when a fixture is opened.
Make sure the unit has 120 VAC / 60 Hz power supply. If you are using the remote controller, is the power button turned
on?
Is the gas supply valve fully open? (p. 30) Is the water supply valve fully open? (p. 30) Is the filter on cold water inlet clean? (p. 36) Is the hot water fixture sufficiently open to draw at least 0.5 GPM
through the water heater? (p. 33)
Is the unit frozen? (p. 35) Is there enough gas in the tank / cylinder? (For Propane models)
The hot water turns cold and stays cold.
Is the flow rate enough to keep the water heater running? (p. 33) If there is a recirculation system installed, does the recirculation
line have enough check valves? (p. 28)
Is the gas supply valve fully open? (p. 30) Is the filter on cold water inlet clean? (p. 36) Are the fixtures clean of debris and obstructions? Check if the flow rate is too low. (p. 33-34)
Fluctuation in hot water temperature.
Is the filter on cold water inlet clean? (p. 36) Is the gas line sized properly? (p. 18) Is the supply gas pressure sufficient? (p. 19)
Check for cross connection between cold water lines and hot water lines.
Troubleshooting
38Page
- WATER HEATER -
PROBLEM SOLUTIONS
Unit does not ignite when water goes through the unit.
Is the flow rate over 0.5 GPM? (p. 33) Check for the filter on cold water inlet. (p. 36) Check for reverse connection and cross connection. If you use the remote controller, is the power button
turned on?
Check if the inlet temperature is too high.
The fan motor is still spinning after operation has stopped.
This is normal. After operation has stopped, the fan motor
keeps running from 15 to 70 seconds in order to re-ignite quickly, as well as purge all the exhaust gas out of the flue.
Unit sounds abnormal while in operation
Contact the manufacturer at 1-877-737-2840.
-Remote controller- (OPTIONAL)-
Remote controller does not display anything when the power button is turned on.
Make sure the unit is supplied with power. Make sure the connection to the unit is correct. (p. 22)
-9007603005 (TM-RE30) only-
If the green LED lights up, the remote controller has been turned ON. When the unit has not operated for five minutes
or more, the display turns off to conserve energy.
An ERROR code is displayed.
Please see p. 39-41.
-EASY-LINK SYSTEM- 510 (T-D2) models only
How are the unit numbers assigned?
For an Easy-Link system, the Parent unit is always labeled
#1 and all other subsequent Child units are numbered randomly.
To check which numbers are assigned to which Child units,
push the button on the computer board of any Child unit as shown below. The unit number will be displayed on the 7-Seg LED. (Refer to p.24 to 27)
7-Seg LED
Button to check
unit numbers
When ON, green
LED is lit.
Troubleshooting
39Page
ERROR CODES
The units are self diagnostic for safety and convenience when trouble shooting.
If there is a problem with the installation or the unit, depending on the model or if there is a
remote controller installed, it will either display a numerical error code on the 7-Seg LED on the computer board (for the 510 (T-D2) models only), display a blinking red LED (for the 110 (T-KJr2) and 310 (T-K4) models), or the error code will display on the remote controller if it is installed.
Consult with the table on the following page for the cause of each error code.
-Single unit installations-
Example: If your unit displays the “321” error code (which signifies an inlet thermistor failure)
110 (T-KJr2) and 310 (T-K4) models:
The red LED on the computer board will be blinking two times.
If the remote controller 9007666005 (TK-RE02) is installed: “32” will display on the screen in its
entirety.
510 (T-D2) models: The 7-seg. LED on the computer board will display “3”…”2”…”1” in that
order one digit at a time and continually repeat.
If the remote controller 9007603005 (TM-RE30) is installed: “321” will display on the screen in
its entirety.
-Easy-Link system for the 510 (T-D2) models only-
Error codes will display differently with units installed within an Easy-Link System, not only to show what the error code is, but to also indicate which unit within the system has the error code. Below is a sample of how the same error code is displayed in an Easy-Link System.
Example:
If Unit #2 has the “321” error code (inlet thermistor failure)
Parent unit: It will display “3”…”2”…”1”…”0”…”2” one digit at a time on the 7-Seg LED. The first
3 numbers indicate the error code. The last two numbers indicate that Unit #2 has the error code.
Unit #2: It will display “3”…”2”…”1
on the 7-Seg LED, just like in the Single Unit example.
Unit #3 and #4: These units will not
display anything, as the error code does not pertain to them.
Remote controller 9007603005
(TM-RE30): It will display “232” on its screen. The first “2” indicates that Unit #2 has the error. The “32” indicates the first two digits of the “321” error code.
Error code on
the
remote controller 9007666005 (TK-RE02)
110 (T
-
KJr2) and 310 (T
-
K4) models
Error code on th
e
computer board
Red LED
510 (T
-
D2) models
Error code on th
e
computer board
7-Seg LED
Error code on
the
remote controller 9007603005 (TM-RE30)
9007603005 (TM
-
RE30)
PARENT
CHILD
CHILD
CHILD
Troubleshooting
40Page
-FAULT ANALYSIS OF ERROR CODES-
110 (T-KJr2) and
310 (T-K4)
510
(T-D2)
Malfunction
description
Diagnosis
Red
LED
Remote Remote
One
Time
03 031
Incorrect dipswitch setting
Check the dipswitch settings on the PCB. (Part
#701)
Five
Times
10 101
Warning for the “991” error code
Check the gas type of the water heater.
Check if there is any blockage in the intake air
and/or exhaust.
If the water heater is installed as a direct-vent
system, check whether there is enough distance between the intake air terminal and the exhaust terminal.
Check the altitude/elevation of area of where the
water heater installed.
Check if there is grease and/or dirt in the burner (Part #101) and the fan motor (Part #103), especially if the
water heater has been installed in a contaminated
area.
Three Times
11 111
Ignition failure
C
heck i
f the Hi
-
limit switch (Part #412
) is properly
functioning.
 Check for connection/breakage of wires (Part #413,
708, 709, 710, 712), burn marks on the computer board (Part #701), and/or soot on the flame rod (Part #108).
Check if there is a buzzing spark ignition sound
coming from the burner (Part #101) when water heater prepares for combustion.
Listen for the double “clunk” sound coming from
gas valve assembly (Part #102) when water heater goes into combustion.
Che
ck if there is leaking from h
eat exchanger. (Pa rt #401
)
Three Times
12 121
Loss of flame
Check i
f the Hi
-
limit switch (Part #412
) is properly
functioning.
 Check for connection/breakage of wires (Part #413, 708,
709, 710, 712), burn marks on the computer board (Part #701), and/or soot on the flame rod (Part #108).
Ch
eck if there is leaking from h
eat exchanger. (Pa rt #401
)
Two
Times
31 311
Output thermistor
failure
Check for connection/breakage of wires and/or
debris on thermistor. (Part #407, 408, 411, 716)
32 321
Inlet
thermistor
failure
N/A N/A 331
Mixing
therm
istor
failure
Two
Times
39 391
Air –fuel Ratio Rod failure
Check for connection/breakage of wires (Part
#709) and/or soot on the AFR rod. (Part #108)
If the error code displayed on the computer board of the Water heater or remote controller,
please check the following. After checking, Consult with the manufacturer.
Troubleshooting
41Page
110 (T-KJr2)
and 310 (T-K4)
510
(T-D2)
Malfunction description
Diagnosis
Red
LED
Remote Remote
N/A N/A 441
Flow Sensor Failure
(Easy-L
ink
System only)
Check for connection/breakage of wires and/or debris
on the flow sensor impeller. (Part #402, 717)
Six
Times
51 510
Abnormal
Gas
Solenoid Valve
Check
for connect
ion/breakage of wires (Part #708
)
and/or burn marks on the computer board (Part
#701).
Six
Times
55 N/A
Abnormal Main Gas Valve
Check
for connect
ion/breakage of wires (Part #708
)
and/or burn marks on the computer board (Part
#701).
Four
Times
61 611
Fan Motor Fault
Check
for connection/brea
kage of wires, dust bui
ldup
in the fan motor (Part #103) and/or burn marks on the computer board (Part #701).
Check for frozen/corrosion of connectors
(Part #103
).
N/A N/A 651
Flow
adjustment Valve Fault
(Easy-Link
S
ystem
only)
Inspect the flow adjustment valve (Part #402), for
connection/breakage of wires (Part #718), locked motor drive due to scale buildup, and/or water leakage.
One
Time
70 701
Computer board Fault
Check for
connection/b
reakage of wires (Part #714
)
and/or burn marks on the computer board (Part #701).
Check the power supply of the water heater.
Six
Times
72 721
False Flame Detection
For indoor models
, check if
condensate drain
is
installed on the vent collar of the water heater.
Check if there is leaking from heat exchanger (Part
#401
).
N/A 74 741
Miscommunication
between Water heater and remote
controller
Check the model type of the remote controller.
 Inspect the connections between the water heater
and remote controller.
Ch
eck the power supply of the water heater.
N/A N/A
761
Misco
mmunication in
Easy-L
ink system
Check if the connections betwe
en the parent
unit and
the child
units are correct. Refer to p.24 to 27.
Five
Times
99 991
Imperfect combustion
Check the gas type of the water heater.
Inspect the environment around the water heater.
Determine how long the unit has been installed.
Check the altitude/elevation of the area of where the
water heater installed.
Check if there is any blockage in the intake air and/or
exhaust.
If the water heater is installed as a direct-vent system,
check whether there is enough distance between the intake air terminal and the exhaust terminal.
Check if there is grease and/or dirt in the burner (Part
# 101) and the fan motor (Part # 104), especially if the water heater has been installed in a contaminated area.
Components Diagram
42Page
COMPONENTS DIAGRAM
Case assembly
110 Indoor (T
-
KJr2
-
IN) 110 Outdoor
(T-
KJr2
-
OS)
310 and 510 Indoor (T-K4-IN and T-D2-IN)
310 and 510 Outdoor (T-K4-OS and T-D2-OS)
00 2
05 0
70 2
05 2
00 7
70 4
00 6
00 5
05 3
06 6
05 3
05 2
05 2
00 1
00 4
05 6
00 4
00 1
00 2
05 0
70 2
05 2
00 7
704
006
005
053
066
05 3
052
05 2
05 6
05 2
00 4
001
05 2
00 3
00 2
05 0
702
05 2
00 7
70 4
00 6
00 5
05 3
06 6
05 2
05 2
05 6
05 1
00 2
05 0
70 2
05 2
00 7
70 4
00 6
00 5
05 3
06 6
05 2
05 2
05 2
00 3
05 2
00 1
00 4
05 6
05 1
Components Diagram
43Page
Burner assembly
110 (T
-
KJr2) models
Burner assembly
Manifold
assembly
10 610 7
10 8
10 9
11 0
06 5
71 2
70 1
05 3
12 0
05 3
71 2
7 11
05 3
71 4
06 2
05 5
11 9
15 1
11 8
05 2
12 1
70 3
05 3
70 4
70 5
40 1
10 4
10 5
10 1
70 9
11 1
05 2
05 3
11 2
11 3
11 4
70 8
05 3
06 7
05 5
05 3
70 6
05 3
05 9
10 3
11 5
05 8
71 3
15 0
06 1
On l y T- K J r2 - I N
05 9
10 1
70 9
11 1
10 2
110 Indoor
(T-
KJr2-IN) only
Components Diagram
44Page
310 (T
-
K4) models and 510 (T
-
D2) models
Fan motor section for outdoor models
Power control
section
Burner assembly
Fan motor
section
for indoor models
Manifold
assembly
11 6
11 7
05 3
10 3
05 4
11 5
05 7
05 8
71 3
10 610 7
10 8
10 9
11 0
06 5
71 2
12 1
70 3
05 3
70 6
70 4
70 5
12 0
05 3
71 1
05 3
71 4
06 2
05 5
05 3
11 7
T- K 4 - O S T- D 2 - O S
12 1
70 3
05 3
70 4
70 5
40 1
05 9
06 0
10 3
40 1
10 4
10 5
05 2
05 3
11 2
11 3
11 4
70 8
06 7
06 6
05 5
06 2
05 3
A
A
70 6
05 3
11 6
A
15 0
06 1
T- D 2 - IN T- D 2 - OS
T- K 4 - IN T- K 4 - OS
T- K 4 - IN T- D 2 - IN
T- D 2 - IN T- D 2 - OS
11 9
15 1
11 8
05 2
10 1
70 9
11 1
10 1
70 9
11 1
70 1
05 3
05 3
71 2
10 2
05 3
310 (T-K4)
models
510 (T-D2)
models
510 (T-
D2)
models
3
10 Indoor
(T-K4-
IN)
510 Indoor (T-D2-IN)
3
10
Out
door (T-K4-OS)
510 Outdoor (T-D2-OS)
Components Diagram
45Page
Water way assembly
110 (T
-
KJr2) models
310 (T
-K4) models
510 (T
-
D2) models
110 (T-KJr2) and 310 (T-K4) models
510 (T
-
D2) models
70 7
71 0
70 8
71 5
10 3
71 7
71 8
70 1
70 9
71 9
71 6
70 1
70 7
70 9
71 4
71 0
70 8
10 3
40 240 2
40 740 871 9
Computer
board Assembly
Exhaust section (
outdoor
model)
Water outlet section
Water inlet section
Bypass
section
40 2
46 1
45 8
05 2
41 5
06 4
46 0
45 6
40 4
40 6
40 5
45 4
40 7
45 7
45 6
46 0
40 9
45 5
41 0
45 4
40 8
06 4
40 3
46 2
45 8
46 0
45 6
45 4
41 1
45 9
05 3
15 3
15 4
15 2
46 3
41 3
45 2
45 0
45 3
45 1
41 4
41 4
46 3
41 3
45 2
45 0
45 3
B
C
C
B
B
C
40 1
40 1
46 3
41 3
45 3
41 4
41 2
06 3
45 1
B
C
40 1
41 4
45 2
45 0
41 4
41 4
45 1
41 2
06 3
41 2
06 3
40 1
Output Temperature Chart
46Page
PARTS LIST
Item#
Description
Part#
110, 310,
510 models
T-KJr2, T
-
K4,
T-D2 models
001
Case assembly
for 110 Indoor (
T-KJr2-IN)
for 110 Outdoor (T-KJr2-OS) for 310 and 510 Indoor (T-K4-IN and T-D2-IN)
for 310 and 510 Outdoor (T
-K4-
OS and
T-D2-OS)
319143
-
159
319143-172 319143-151
319143
-
211
EK415
EK432 EK402
EKK41
002
F
ront cover for
110 Indoor (
T-KJr2-IN)
for 110 Outdoor (T-KJr2-OS)
for 310 Indoor (T-K4-IN)
for 310 Outdoor (T-K4-OS)
for 510 Indoor (T-D2-IN)
for 510 Outdoor (
T-D2-OS)
319143
-
163
319143-173 319143-152 319143-371 319143-174
319143
-
175
EK
419
EK433 EK403 EK409 EK434
EK435
003
004
Air blockage plate
for 110 Indoor (
T-KJr2-IN
), 310 Indoor (
T-K4-IN
)
and 510 Indoor (T-D2-IN)
Bracket
319143
-
150
319143
-
184
EK401
EK
J09
005
006
Junction b
ox
Junction box inner plate
319143
-
014
319143
-
128
EK
J64
EKJ66
007
Back guard panel for 110
(T-KJr2)
models
Back guard panel for 310
(T-K4
) and
510 (T-D2) models
319143
-
338
319143
-
221
EX00M
EKK5H
050
051 052
053
S
crew M4
×12
(W/Washer)
Screw M4×10 (W/Washer)
Screw M4×10 (Coated)
Screw M4x10
319143
-
025
319143-325 319143-026
319143
-
060
EW000
EW001 EW002
EW003
054
055
056
Hex head s
crew M4
×12 (W/Washer)
Hex head screw M4x8
Screw M4x10
319143
-
326
319143-063
319143
-
372
E
W004
EW005
EX014
057
058
059
Screw
M3x6 SUS3
Screw M3x10
Pan screw M4x12 (W/Washer)
319143
-
330
319143-327
319143
-
061
EW00B
EW008
EW00H
060
061 062 063
064
Pan screw M4x10 FEZN
Tap tight screw M4x12 FEZN
Pan screw M4x10
Screw M3x6
Screw M4x6
319143
-
332
319143-201 319143-062 319143-087
31914
3-328
E
W024
EKK31 EW006 EW00A
EW009
065
066
067
Pan screw M4x8
Nylon clamp
Wire clamp 60
319143
-
059
319143-143
319143
-
048
EW00D
EC00X
EM167
101 Burner
assembly for 110
(T-KJr2)
models
Burner assembly for 310
(T-K4
) and
510 (T-D2) models
319143
-
161
319143
-
030
EK417
EKH5W
102 Manifold with gas valve assembly LP
for 110 (
T-KJr2)
models
Manifold with gas valve a ssembly LP for 310 (T-K4) and 510 (T-D2) models
Manifold with gas valve assembly NA for 110 (T-KJr2) models
Manifold with gas valve assembly NA f
or
310 (T-K4) and 510 (
T-D2)
models
319143
-
169
319143-046 319143-165
319143
-
368
EK
429
EKH6T
EK421
EKK5K
103
Fan motor for 110
(T-KJr2)
models
Fan motor for 310 Indoor (T-K4-IN) and 510 Indoor (T-D2-IN)
Fan motor for
310 Outdoor (
T-K4-OS
) and 510 Outdoor (
T-D2-OS)
319143
-
347
319143-043
319143
-
217
EX02E
EKK25
EKK54
Output Temperature Chart
47Page
Item#
Description
Part#
110, 310,
510 models
T-KJr2, T
-
K4,
T-D2 models
104 Burner holder gasket for 110
(T-KJr2)
models
Bu
rner holder gasket for 3
10 (T-K4) and
510 (T-D2) models
319143
-341
319143
-
032
EX00V
EKK0G
105
106
107
Burner gasket
Burner window
Rod holder gasket
319143
-
031
319143-033
319143
-
034
EKK2X
EKK2V
E
KK2W
108
Flame rod for 110
(T-KJr2)
models
Flame rod for 310 (
T-K4
) and
510 (T-D2) models
319143
-
339
319143
-
035
E
X00R
E
KK0E
109 Igniter rod for 110
(T-KJr2)
models
Igniter rod for 310 (T-K4) and 510 (T-D2) models
319143
-
373
319143-037
E
X00S
EKK0F
110
111
Rod holder for 110
(T-KJr2)
models
Rod holder for 310 (T-K4) and 510 (T-D2) models
Rod cap
319143
-
340
319143-036
319143
-
038
EX00U
EKK32
EKN61
112
Burner damper for 110
(T-KJr2)
models
Burner damper for 310 (
T-K4
) and
510 (T-D2) models
319143
-
170
319143
-
156
E
K430
EK412
113
114 115
Manifold gasket A
Manifold gasket B
Fan damper for 110 Indoor (T-KJr2-IN)
Fan damper for 310
In
door (
T-K4-IN
) and
510 Indoor
(T-D2-IN)
319143
-
044
319143-045 319143-160
319143
-
367
EKK2Y
EKK2K
EK416
TU001
116
117
Pressure port for 310
(T-K4
) and
510 (T-D2) models
Combustion chamber tube for 310 Indoor (T-K4-IN) and 510 Indoor (T-D2-IN)
Combustion chamber tube for 310 Outdoor (T-K4-OS) and
510 Outdoor (
T-D2-OS)
319143
-
042
319143-041 319143-344
EKK2D
EKK2N
EX019
118
119
120
Gas inlet
Gas inlet ring
Igniter plate
319143
-
050
319143-049
319143
-
051
EKK1E
EKK2Z
EKK1B
121 S
urge box plate for 110 (
T-KJr2
) a
nd
310 (T-K4) models
S
urge box plate for 510
(T-D2)
models
319143
-
213
319143
-
176
E
KK4H
EK436
150
151 152
O-ring P
18 NBR (Black)
O-ring P20 NBR (Black)
Silicon ring for 110 Outdoor (T-KJr2-OS)
Silicon ring
for 310 Outdoor (
T-K4-OS
) and 510 Outdoor (
T-D2-OS)
319143
-
350
319143-057 319143-370
319143
-
206
EZP18
EK042
EK442
EKK3G
153
Rain protection plate in Exhaust chamber for 110
Outdoor
(T-
KJr2-OS), 310
Outdoor (
T-K4-OS
) and
510 Outdoor
(T-D2-OS)
319143
-
216 EKK53
154 Exhaust port
319143
-
219 EKK56
401 Heat exchanger assembly for 110 Indoor
(T-KJr2-IN)
for 110 Outdoor (T-KJr2-OS)
for 310 Indoor (T-K4-IN)
for 310 Outdoor (T-K4-OS)
for 510 Indoor (T-D2-IN)
for 510 Outdoor
(T-D2-OS)
319143
-
162
319143-166 319143-153 319143-157 319143-369
319143
-
177
E
K418
EK426
EK406
EK413
TU002
EK437
402 Flow adjustment valve/Flow sensor
for 110 (T-KJr2) and 310 (T-K4) models
Flow adjustment valve/Flow sensor for 510
(T-D2)
models
319143
-
167
319143
-
178
EK427
EK438
403
404 405
406
Bypass valve for 510
(T-D2)
models
Water inlet
Inlet drain plug
Inlet water filter
319143
-
186
319143-193 319143-197
319143
-
198
EKK0U
EKK1U
EKK2B
EKK2C
407 Inlet thermistor for 110
(T-KJr2
) and
310 (T-K4) models
Inlet thermistor for 510
(T-D2)
models
319143
-
214
319143
-
085
EKK4J
EKK38
Output Temperature Chart
48Page
Item#
Description
Part#
110, 310,
510 models
T-KJr2, T
-
K4,
T-D2 models
408
Outlet thermistor for 110
(T-KJr2)
and
310 (T-K4) models
Mixing thermistor for 510
(T-D2)
models
319143
-
218
319143
-
190
EKK55
EKK1A
409
410
411
Water outlet
Outlet drain plug
Output thermistor for 510
(T-D2)
models
319143
-
194
319143-199
319143
-
096
EKK1V
EKK2E
EKK2T
412 Hi-Limit switch for 110 (
T-KJr2
) and
310 (T-K4) models
Hi-Limit switch for 510
(T-D2)
models
319143
-
228
319143
-
095
EM212
EKN34
413
414
415
Overheat
-
cut-off
fuse
Heater
Inlet heater
319143
-
149
319143-200
319143
-
078
EK333
EKK2R
EKK2P
450
451 452 453
454
Pipe heater fixing plate
Heater fixing plate 16
Fuse fixing plate 18 Fuse fixing plate 14
O-ring P4 FKM
319143
-
088
319143-125 319143-066 319143-146
319143
-
082
EK
K27
EK031
EKK26
EK029
EZM04
455
456
457
O-ring P6 FKM
O-ring P14 FKM
O-ring P15 FKM
319143
-
080
319143-100
319143
-
091
EZM06
EZM14
EZM15
458
459 460 461 462
463
O-ring P16 FKM
Fastener “4-11” for 510 (T-D2) models
Fastener “14-22”
Fastener “16A”
Fastener “16-25A” for 510 (T-D2) models
Silicon ring
319143
-
083
319143-097 319143-105 319143-226 319143-205
319143
-
065
EZM16
EKH30
EKK24 EM192
EKK39
EKN50
701
702
Computer board for 110
(T-KJr2)
models
for 310 (T-K4) models for 510 (T-D2) models
Transformer
319143
-
164
319143-158 319143-179
319143
-
182
E
K420
EK414
EK439
EKH09
703
704
Surge box
AC120V wire for 110 (T-KJr2) models
AC 120 V wire for 310
(T-K4
) and
510 (T-D2) models
319143
-
168
319143-222
319143
-
138
EK
428
EKK5M
EKK3C
705 Transformer wire for 110 (
T-KJr2)
models
Transformer wire for 310 (T-K4) and 510 (T-D2) models
319143
-
155
319143-180
EK408
EK440
706
707
AC120V Power ON
-
OFF switch
Switch wire for 110 (T-KJr2) models
Switch wire for 310
(T-K4
) a
nd
510 (T-D2) models
319143
-
141
319143-154
319143
-
181
EKK4V
EK407
EK441
708 Gas
valve wire for 11
0 (T-
KJr2
) and
310 (T-K4) models
Gas
valve wire for 510
(T-D2)
models
319143
-
207
319143
-
188
EKK3K
EKK10
709 Flame rod wire for 110
(T-KJr2)
models
for 310 (T-K4) models
for 510
(T-D2)
models
319143
-
171
319143-208
319143
-
189
EK431
EKK3L
EKK11
710 EH-IG wire for 110
Indoor (
T-KJr2-IN
) and
310 Indoor
(T-K4-IN)
EH-IG wire with freeze protection thermostat for 110 Outdoor
(T-KJr2-OS), 310 Outdoor (T-K4-OS) and 510 Outdoor (T-D2-OS)
EH-IG wire for 510 Indoor
(T-D2-IN)
319143
-
209
319143-210
319143
-
187
EKK3R
EKK40
EKK0Z
711
712
Igniter
High voltage igniter cable
319143
-
052
319143
-
039
EKN74
EKK2M
Output Temperature Chart
49Page
OUTPUT TEMPERATURE CHART
Output Temperature vs. GPM (Max. 6.6 GPM) with Various Inlet Water Temperature
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
Out Put Hot Water GPM
40 F 50 F 60 F 70 F
40 F
3.8 3.5 3.3 3.1 2.9 2.7 2.5 2.4 2.3 2.1 1.9 1.8
50 F
4.6 4.2 3.8 3.5 3.3 3.1 2.9 2.7 2.5 2.3 2.1 2.0
60 F
5.7 5.1 4.6 4.2 3.8 3.5 3.3 3.1 2.9 2.5 2.3 2.2
70 F
6.6 6.6 5.7 5.1 4.6 4.2 3.8 3.5 3.3 2.9 2.5 2.4
100 105 110 115 120 125 130 135 140 150 160 165
Item#
Description
Part#
110, 310,
510 models
T-KJr2, T-K4,
T-D2 models
713 Freeze protection thermostat for 110 Indoor (T-KJr2-IN),
310
Indoor (
T-K4-IN
) and
510 Indoo
r (T-D2-IN)
319143-185 EKJ59
714 Proportional gas valve wire for 110 (T-KJr2) and 310 (T-K4) models
Proportional gas valve wire for 510
(T-D2)
models
319143-220
319143
-
133
EKK58
EKK12
715 716 717
718
Pump and multi cable for 510 (T-D2) models
Thermistors wire for 510 (T-D2) models
RS-VG wire for 510 (T-D2) models
Water valves wire for 510
(T-D2)
model
s
319143-204 319143-195 319143-203
319143
-
202
EKK36
EKK1Z
EKK35
EKK33
719 Computer board cover for 110 (T-KJr2) and 310 (T-K4) models
Computer board cover for 510
(T-D2)
models
319143-212
319143
-
191
EKK49
EKK1M
110 (T
-
KJr2) models
Chart is based on properly sizes gas line
Output Temperature Chart
50Page
Output Temperature vs. GPM (Max. 8.0 GPM) with Various Inlet Water Temperature
0.0
2.0
4.0
6.0
8.0
10.0
Out Put Hot Water GPM
40 F 50 F 60 F 70 F
40 F
5.2 4.8 4.4 4.1 3.9 3.7 3.5 3.3 3.1 2.8 2.6 2.5
50 F
6.2 5.7 5.2 4.8 4.4 4.1 3.9 3.7 3.5 3.1 2.8 2.7
60 F
7.8 6.9 6.2 5.7 5.2 4.8 4.4 4.1 3.9 3.5 3.1 3.0
70 F
8.0 8.0 7.8 6.9 6.2 5.7 5.2 4.8 4.4 3.9 3.5 3.3
100 105 110 115 120 125 130 135 140 150 160 165
Output Temperature vs. GPM (Max. 10.0 GPM) with Various Inlet Water Temperature
0.0
2.0
4.0
6.0
8.0
10.0
12.0
Out Put Hot Water GPM
40 F 50 F 60 F 70 F
40 F
5.4 5.0 4.7 4.3 4.1 3.8 3.6 3.4 3.3 3.0 2.7 2.6 2.5 2.4 2.3 2.2
50 F
6.5 5.9 5.4 5.0 4.7 4.3 4.1 3.8 3.6 3.3 3.0 2.8 2.7 2.6 2.5 2.4
60 F
8.1 7.2 6.5 5.9 5.4 5.0 4.7 4.3 4.1 3.6 3.3 3.1 3.0 2.8 2.7 2.6
70 F
10.0 9.3 8.1 7.2 6.5 5.9 5.4 5.0 4.7 4.1 3.6 3.4 3.3 3.1 3.0 2.8
100 105 110 115 120 125 130 135 140 150 160 165 170 175 180 185
*When the set temperature i
s 131°F or higher, maximum flow rate is limited to
8.0 GPM.
510 (T
-
D2) models
310 (T
-
K4) models
Warranty
51Page
LIMITED WARRANTY
1. General terms of limited warranty:
This limited warranty gives you specific legal rights, and you may also have other rights which vary from State to State. The manufacturer will honor the warranty to the original retail buyer at the original location only, and it is not transferable.
THIS WARRANTY COVERS ONLY FAILED MECHANICAL AND ELECTRICAL PARTS DUE TO FACTORY DEFECTS UNDER NORMAL USAGE FOR THE PRODUCT’S INTENDED PURPOSES AND WITHIN THE APPLICABLE PERIOD SPECIFIED IN THE FOLLOWING TABLES. ONLY DIRECT DAMAGES SHALL BE RECOVERABLE BY A CLAIMANT UNDER THIS LIMITED WARRANTY AND, IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, BREACH OF WARRANTY, TORT LIABILITY (INCLUDING NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR OTHERWISE WILL BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR INDIRECT CONSEQUENTIAL DAMAGES INCLUDING PROPERTY DAMAGE, PERSONAL DAMAGES, LOSS OF USE, OR INCONVENIENCE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITA TION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY NO T APPLY TO YOU.
2. Warranty for models: 510 (T-D2) models
[Unit: Year]
Application
HX
(1)
Parts Labor
Single Family
Domestic Hot
Water
No Recirculation
12
5
1
(3)
On-Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
5 Pump Control
Timer Only
3 3
No Pump Control (24 hr.)
Commercial
or
Multi-Family
Domestic Hot
Water
No Recirculation
5 5
1
(3)
On-Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
Pump Control
Timer Only
3 3
No Pump
Control (24 hr.)
Heating
(4)
All Types
5 5
1
(3)
Warranty for models: 110 (T-KJr2) and 310 (T-K4) models
[Unit: Year]
Application
HX
(1)
Parts Labor
Single Family
Domestic Hot
Water
No Recirculation
12 5
1
(3)
On-Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
3 3
Pump Control
Timer Only
1 1
No Pump Control (24 hr.)
Multi-Family
Domestic Hot
Water
No Recirculation
3 3
1
(3)
On-Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
Pump Control
Timer Only
1 1
No Pump Control (24 hr.)
Heating
(4)
All Types
1 1
1
(3)
Commercial
All Types
1 1
1
(3)
(1) Heat exchanger (2) An on-demand recirculation system is a system that utilizes either a push-button or other type of
manual activation (as opposed to automatic activation with a temperature sensor or timer) to activate the circulation pump. An on-demand recirculation system can use either the existing cold water line as the return line or have its own dedicated return line.
Warranty
52Page
(3) Limited Labor Coverage
The manufacturer will provide for reasonable labor charges associated with warranty repairs
or replacements within one (1) year from the date of purchase. The manufacturer will only pay directly to the service provider.
Warranty service must be performed by an authorized Service Representative. A list of
authorized Service Representatives is available upon request.
All warranty claims and warranty service must be authorized and approved by the
manufacturer.
(4) Includes dual-purpose applications (combination heating and domestic).
3. Repair, Replacement or Refund:
The manufacturer or its authorized Service Representative will, at its sole discretion, repair or replace any failed or defective mechanical or electrical parts, or components thereof, or, if the manufacturer or its authorized Service Representative cannot replace said parts, and repair is not commercially practicable, the manufacturer or its authorized Service Representative will refund the purchase price. The manufacturer or its authorized Service Representative may, at its sole discretion, use new, refurbished or reconditioned parts.
4. Limitation on Duration of Implied Warranties:
ANY IMPLIED WARRANTIES ARISING UNDER STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, SHALL IN NO EVENT EXTEND PAST THE EXPIRATION OF ANY WARRANTY PERIOD HEREUNDER. SOME STATES DO NO ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
5. THIS WARRANTY WILL NOT COVER THE FOLLOWING:
Any product that is not installed by a licensed plumber, gas installer, or contractor. Damages due to accidents, abuse, misuse, improper installation, misapplication, or incorrect sizing. Damages due to fires, flooding, freezing, electrical surges, or any Acts of God. Damages due to unauthorized alterations, attachments, and/or repairs. Damages due to a lack of maintenance (e.g. water filter, water treatment system, vent blockage, etc.) Any product installed in an improper environment (e.g. corrosive, dusty, chemically contaminated,
excessive lint, etc.).
Freeze damage that occurs without taking proper preventive measures as described in the installation
manual.
Condensate damage due to improperly installed or lack of a condensate trap (drain). Any product not installed in compliance with all applicable local & state codes, ordinances, and good
trade practices.
Any product sold to or installed in areas outside of the fifty states (and the District of Columbia) of the
United States of America and Canada.
Any product installed in applications that cause the water heater to activate more than 300 times per
day (this averages to an activation every 5 minutes in a 24-hour period).
Any failures that are not due to defects in materials or workmanship (mechanical and/or electrical parts). Damages due to improper installation:
Gas: incorrect gas pipe sizing, incorrect gas meter sizing, incorrect gas type, and/or gas pressures
that fall outside the product’s specified range.
Water: incorrect water pipe sizing, water pressures that fall outside the product’s specified range, recirculation flow rates that fall outside the product’s specified range (air removal), and/or lack of proper methods of air removal in a closed-loop, circulation system (see installation manual for details).
Electric: supply power voltages that fall outside the product’s specified range.
Damages due to water quality:
Introduction of liquids other than potable water or potable water / glycol mixtures into the product.
Introduction of pool water, spa water, or any chemically treated water into the product.
Introduction of hard water measuring more than 7 grains per gallon (120 ppm) for single family domestic applications or more than 4 grains per gallon (70 ppm) for all other types of applications into the product.
Introduction of untreated or poorly treated well water into the product.
Introduction of water with pH levels less than 6.5 and greater than 8.5 into the product.