TAINET DT-128, DT-192 User Manual

TAINET
DT-128/DT-192
High-Speed Network Termination Unit
使用手册
The Professional Partner
TAINET COMMUNICATION SYSTEM CORP.
Headquarters:
V1.3 07007-00004 2004/03/24
Beijing Branch:
3F, A Building, 113 Zhi Chun Lu, HaiDian District, Beijing, China Zip Code: 100086 TEL: 86-10-62522081~87 FAX: 86- 10-62522077
THE TAINET DT-128 SERIES NTU 1-1
CONTENTS
CHAPTER 1 : THE TAINET DT-128/DT-192 Series NTU ............................................1
1.1 描述 ..................................................................................................................................1
1.2 技术规范 ..........................................................................................................................2
1.3 型号说明 ..........................................................................................................................3
CHAPTER 2 : щā 1
2.1 描述 ..................................................................................................................................1
2.2 拆封 ..................................................................................................................................1
2.3 工作环境需求 ..................................................................................................................1
2.4 地点选择 ..........................................................................................................................1
2.5 电源连接 ..........................................................................................................................2
2.6 与2/4线的连接 .................................................................................................................2
CHAPTER 3 : ࢬڕ෉āāځ ........................................................................................1
3.1 面板介绍 ..........................................................................................................................1
3.2 DT-128/DT-192操作说明................................................................................................2
3.3 各Menu及设定状态 .........................................................................................................4
3.4 各MENU的详细说明.......................................................................................................6
3.4.1 Test Menu测试菜单 ......................................................................................................6
3.4.2 Config NTU Menu设定菜单......................................................................................... 7
3.4.3 Config DTE Menu设定菜单 .........................................................................................8
3.4.4 Profile Menu参数档案菜单 ..........................................................................................9
CHAPTER 4 : āϡāā.....................................................................................................1
4.1 前言 ..................................................................................................................................1
4.2 2W/4W 无感双绞线........................................................................................................1
4.3 LT 模式 VS. NT 模式 ................................................................................................... 1
4.4 同步 VS. 异步 ................................................................................................................2
4.5 Configuration Profile Set-Up............................................................................................2
4.5.1 出厂设置 .......................................................................................................................2
4.6 远程设置 ..........................................................................................................................3
CHAPTER 5 : āā 1
5.1 描述 ..................................................................................................................................1
5.2 测试仪器 ..........................................................................................................................1
5.3 定期维护 ..........................................................................................................................1
5.4 故障排除步骤 ..................................................................................................................1
5.5 回厂修理 ..........................................................................................................................1
INFORMATION TO THE USER
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device. Pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and if not installed and used in accordance with the instructions may cause harmful interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This booklet is available from the US government Printing Office, Washington, DC 20402, Stock NO. 004-000-00345-4.
The shielded RS-232 cable is to be used in order to ensure compliance with FCC Part 15, and it is the responsibility of the user to provide and use shielded RS-232 cable from NTU to personal computer.
CAUTION: Any changes of modifications not expressly approved by the grantee
of this device could void the user's authority to operate the equipment.
内容
1.1 描述
1.2 技术规格
1.3 型号说明
CHAPTER 1
THE TAINET DT-128/DT-192 SERIES NTU
CHAPTER 1 : THE TAINET DT-128/DT-192 Series NTU
CHAPTER 1 : THE TAINET DT-128/DT-192 Series NTU
1.1 描述
TAINET DT-128/DT-192 DT-128N/DT-192N 是高速、同/异步,全双工网络
终端设备 (NTU)。 The DT-128/DT-192 是台式客户端设备, 而 DT-128N/ DT-192N 为卡片式可插入能容纳 16 片 NTU 卡的 TRS32 机框中。
DT-128 DT-128N 在 2/4 wire 无感双绞线可实现同步 2400bps-128Kbps,
异步 300bps -38.4Kbps 的全双工传输, DT-192 和 DT-192N 实现同步 2400bps-19.2kbps, 异步 300bps-19.2kbps, 它采用 2B1Q 线路编码和回波抵 消技术, 完全符合 ANSI T1.601 标准。
DT 系列, 两线或四线方式时, 0.4mm 线径可传输 6 公里, 0.5mm 线径可传输
7.8 公里。
• DT 系列, 在 LT 模式时可提供内, 外两种时钟, 以适应不同的应用环境。
• DT 系列, 具有仿真环路测试,数字环路测试(本地及远程), 误码测试功能。
DT 系列在前面板 LED 显示器可显示 PWR, DTR, DSR, RTS, CTS, TXD,
DCD, RXD, ACT TST 信号状态。
通过 D 信道可实现远程遥控功能。
通过前面板的 2*16 字符背光液晶(LCD)显示屏和五个按键可完全实现 NTU
的监控设置功能。
通过基于 Windows 平台的台联网络管理系统(TAINET MANAGER for
Windows) 可将指令直接传输到 TRS-32 的控制模块, 完成对 DT-128N/ DT-192N 的监控、管理。
CHAPTER 1 : THE TAINET DT-128/DT-192 Series NTU
1.2 技术规范
DT-128/DT-192 DT-128N/DT-192N NTU 完全符合 ANSI T1.601标准。
DTE 速度
(1) Synchronous : 128K/64K/38.4K/*19.2K/*9600/*4800/*2400 bps (2) Asynchronous : 38.4K/*19.2K/*9600/*4800/*2400/*1200/*600/*300 bps
:*代表DT-192/N所支持的速率
线路需求 : 2 wire or 4 wire 无感双绞线
传输范围
2/4-wired 模式
(1) Up to 6.0 Km over 26 gauge wire (2) Up to 7.8 Km over 24 gauge wire
线路编号 : 2B1Q
输出电平 : 13 -3 dBm
线路阻抗 : Balanced 135Ω
线路接口 : RJ11 Connector
均衡 : Adaptive Equalizer
测试功能
(1) Analog Loopback (2) Digital Loopback (Local or Remote) (3) Remote Configuration (4) BERT - Bit Error Rate Test with Test Pattern and Error Count
时钟 LT : Internal or External clock
NT : Loopback clock
电源需求 : 90 ~ 265 VAC auto range, 47 ~ 63 Hz
直流电源 : -36 ~ -72 VDC option (for Rack) Dual Redundant AC or DC Power Supply option (for Rack)
功率消耗 : Less than 7 Watts (Stand Alone Type) Less than 6.5 Watts (Rack Mount Type) Less than 110 Watts (Full Shelf Equipped)
CHAPTER 1 : THE TAINET DT-128/DT-192 Series NTU
工作温度 : 0 °C ~ 50 °C 储存温度 : -25 °C ~ 70 °C 相对湿度 : up to 95 % (non-condensing)
尺寸重量
(1) Stand-alone Type (DT-128/DT-192) - 194 W x 60 H x 316 D mm, Weight
1.5kg
(2) Rack-mounted Type (DT-128N/DT-192N) - 220 W x 26 H x 328 D
mm,Weight 0.6kg
(3) Shelf (TRS32 RACK) - W - 19", H - 5RU, D - 380 mm, Weight 8 kg
DTE 接口
(1) EIA RS-232D, ITU-T V.28, 25pin D type, female (2) EIA RS-530 25pin D type, female (3) V.35 - 34 pin, female (4) X.21/V.11 - 15pin, female (5) G.703 64kbps codirectional (DT-128/DT-128N only)
1.3 型号说明
DT-128 High speed 128Kbps NTU (stand alone type)
DT-128N Rack mount type DT-128
DT-192 High speed 19.2kbps NTU (stand alone type)
DT-192N Rack mount type DT-192
NMC32 NMS Control unit
TRS32 19" width rack for up to 16 DT-128N or DT-192N cards
PW-132A 90 ~ 265 VAC 132W power unit for rack
PW-132D -36 ~ -72 VDC 132W power unit for rack
Interface option V.35, V.24/RS-232, RS-530, X.21/V.11, G.703 64Kbps co-directional
网络管理系统(NMS) TAINET Manager for Windows
CSR NMS control unit with LAN and PPP interface
内容
2.1 描述
2.2 拆封
2.3 工作环境需求
2.4 地点选择
2.5 电源连接
2.6 与 2/4 线的连接
CHAPTER 2
CHAPTER 2 : 安装
2.1 描述
本章告诉使用者安装TAINET DT-128/DT-192所需的注意事项, 以保证机器的正 常工作。 有关 DT-128N/DT-192N ( 机架式) 的相关内容, 使用者可以从 TAINET TRS32 Shelf 用户手册中得到。
2.2 拆封
拆开包装后, 请保存包装盒及保护材料, 以便于您以后库存或运输的需要。 每一 台完整的 DT-128/DT-192 包装应包括下列物品:
一本 DT-128/DT-192 用户使用手册。 一根2m模块式电话线, 两端为RJ11插头。 一个为双绞线应用提供的六芯接线盒。
传输不良是大部分DT-128/DT-192损坏的原因, 当您收到本产品后, 请仔细检查 是否有因运输而到至的损坏。 如有, 请与运输者接洽。
其它的损坏或少了任一附件, 请与经销商或本公司直接联系。
2.3 工作环境需求
FCC规定各种通信设备都必须包括防止电气冲击的设计。 TAINET DT-128/ DT-192完全符合FCC的规定,但使用者必须依照下列注意事项才可保证您的设备 安全:
确定使用正确的电源接地系统(参照 article 250 of the National Electrical Code
handbook) 正确的接地系统应包括:
接地棒(Ground Rod)至少深入地表2.44m以上。建筑物的水管配置最好使用金属材料的水管, 在分流处使用铜质的接头。 装设突波接收器(Surge Protecotr)DT-128/DT-192AC电源座间。如有任何机器与DT-128/DT-192直接或间接相连, 如计算机、打印机等, 这
些设备电源线都需使用同组电源座。
确定线路是否装有Surge Protector
2.4 地点选择
DT-128/DT-192与您的DTE设备之间的最大距离为15.24m, AC电源之间的最 大距离1.83m
N
N
将DT-128/DT-192安装于一个洁净的区域内, 为了保证对前面板的操作和后面电 源线的连接, 至少需要有前面15.24 cm, 后面10.2 cm 的距离。 不要将 DT-128/DT-192放置于其它设备之上。
注意: 为防止DT-128/DT-192过热, 在其四周2.54 cm之内不要放置任何物品,
也不要将DT-128/DT-192侧置。
2.5 电源连接
检查DT-128/DT-192底盖标签上的电源要求。一旦您确认您的电源符合要求, 訧 可以 将电源插头插入DT-128/DT-192。
如果您的DT-128/DT-192已经上述步骤正确的安装完成, 您可以打开电源开关。 DT-128/DT-192 会在前面板的液晶上显示提示信息之前, 进行自我检测。
2.6 2/4线的连接
按照下列步骤进行2/4 线的连接:
1) 将四芯电缆插入RJ11接口。
2) 进入Config NTU MENU"Line type",选择所需之线路模式2W/4W/4W Att
RJ11 各接脚定义如下:
Pin No. Color 2-Wire 4-Wire
1
/A
RX2 Black
TXTX/RX3 Red
TXTX/RX4 Green
RX5 Yellow
DTE
/A
Line
6
ON OFF
Fig 2-1 : 2 线/4 线 连接