Taiden HCS-4100MA/50, HCS-4100MA/FS/50, HCS-4100MB/50, HCS-4100MC/50 Installation And Operating Manual

HCS-4100/50 Series Fully Digital Congress System
Installation and Operating Manual
V 1.8
I
Remark:
All rights reserved for translation, reprint or reproduction Contents may change without prior announcement All technical specifications are guideline data and not guaranteed features TAIDEN Co., Ltd. is not responsible for any damage caused by imprope r use of this manual
The equipment must be connected to earth! This product conforms to the rules of the European directive 2004/108/EC. To protect your hearing, avoid high pressure level on earphones. Adjust to a lower and convenient level.
If any detailed information is needed, please contact your local agent or TAIDEN service center in your region.
Any feedback, advice and suggestion about the pro ducts is appreciated
TAIDEN is the registered trademark of TAIDEN Co., Ltd.
In order to extend the life time of the whole system, we strongly recommend that the congress system be
scheduled to shut down every day in the evening when not in use.
II
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus.
6. The MAINS plug serving as a disconnection device, should be easy to operate.
7. The apparatus should be connected to the MAINS socket-outlet with protective e ar th.
8. Clean only with dry cloth.
9. Do not block any ventilation openings. Install in accordance with the manufacturer’s inst ructions.
10. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
11. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized pl ug has two blades with one wider than the other. A ground ing type plug has two blades and a third grounding pro ng. The wide blade and the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
12. Protect the power cord from being walked on or pinched particularly at plugs, convenienc e receptacles, and the point where they exit from the appar atus.
13. Only use attachments/accessories specified by the manufacturer.
14. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus com bination to avoid injury from tip-over.
15. Unplug this apparatus during lightning stor ms or when unused for long periods of time.
16. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the appar atus has been exposed to rain or moisture, does not operate normally, or has been dropped.
17. Do not place the equipment on any uneven or unstable stand; original product package or appropriate package should be used to avoid damage caused by strong impacts during transportation.
18. Power supply cords: AC 100 V - 120 V 60 Hz or AC 220 V - 240 V 50 Hz
19. For service, please contact the nearest TAIDEN Service Center.
20. All TAIDEN products are guaranteed for definite time (see the WARRANTY CARD f or details) excluding the following cases:
A. All damage or malfunction caused by human
negligence;
B. Damage or malfunction caused by improper
operating by operator;
C. Parts damage or loss caused by disassembling
the product by non-authorized personnel.
21. Use ONLY specified connection cable to connect the system equipment.
22. Upon receipt of the product, please fill out the Warranty Card enclosed and post it to TAIDEN Service Center.
The lightning flash with an arrowhead symbol, with an equilateral triangle, is intended to alert the user to the presence of uninsulated ‘dangerous voltage’ within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
CAUTION: To reduce the risk of electric shock, DO NOT open covers, no user serviceable parts inside. Refer servicing to qualified service personnel only.
TO REDUCE THE RISK O
F FIRE OR ELECTRIC SHOCK,
DO
NOT EXPOSE THIS EQUI
PMENT TO RAIN OR MOISTURE.
TO REDUCE THE RISK O
F FIRE OR ELECTRIC S
HOCK, DO
NOT EXPOSE THIS EQUI
PMENT TO RAIN OR MOISTURE.
CAUTION: DO NOT use alcohol, ammon ia or petroleum solvents or abrasive cleaners to clean the devices.
III
Important Safety Instructions
The exclamation mark within an equilate ral triangl e is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Attention: Installation should be performed by qualified service personnel only in accordance with the National Electrical or applicable local codes.
Power Disconnect: Units with or without ON – OFF switch have power supplied to the unit whenever the power cord is inserted into the power source; however, the unit is operational only when the ON – OFF switch is in the ON position. The power cord is the main power disconnect for all units
WARNING:
The apparatus should be
connected to a mains socket outlet with a protective earthing connection.
WARNING: To reduce the risk of fire or electric shock, DO NOT expose units to rain or moisture.
IV
Contents
Installation & User Guide .........................................................................................................VIII
Chapter 1: Introduction ............................................................................................................... 1
1.1 Summary ........................................................................................................................................................... 1
1.2 System technology ............................................................................................................................................ 2
1.3 Functions .......................................................................................................................................................... 6
1.4 Features ............................................................................................................................................................ 8
Chapter 2: Congress main unit (CMU) ..................................................................................... 10
2.1 Fully Digital Congress System Main Unit ........................................................................................................ 11
2.1.1 Functions and instructions ......................................................................................................................................... 11
2.1.2 Installation ................................................................................................................................................................. 13
2.1.3 Connection ................................................................................................................................................................ 14
2.1.4 Configuration and operation ...................................................................................................................................... 16
2.2 Extension Main Unit ........................................................................................................................................ 39
2.2.1 Functions and instructions ......................................................................................................................................... 39
2.2.2 Installation ................................................................................................................................................................. 40
2.2.3 Connection ................................................................................................................................................................ 41
Chapter 3: Congress units ........................................................................................................ 42
3.1 Overview ......................................................................................................................................................... 42
3.2 HCS-48U6 series congress unit ..................................................................................................................... 48
3.2.1 Functions and indications .......................................................................................................................................... 48
3.2.2 Installation ................................................................................................................................................................. 51
3.2.3 Connection ................................................................................................................................................................ 54
3.2.4 Operation .................................................................................................................................................................. 56
3.3 HCS-48U7/U8/U9 series congress unit .......................................................................................................... 60
3.3.1 Functions and indications .......................................................................................................................................... 60
3.3.2 Installation ................................................................................................................................................................. 64
3.3.3 Connection ................................................................................................................................................................ 73
3.3.4 Operation .................................................................................................................................................................. 77
3.4 HCS-48U10 series congress unit ................................................................................................................... 83
3.4.1 Functions and indications .......................................................................................................................................... 83
3.4.2 Installation ................................................................................................................................................................. 85
3.4.3 Connection ................................................................................................................................................................ 87
3.4.4 Operation .................................................................................................................................................................. 89
3.5 HCS-4886/87/88 series congress unit ............................................................................................................ 93
3.5.1 Functions and indications .......................................................................................................................................... 93
3.5.2 Connection ................................................................................................................................................................ 96
3.5.3 Operation .................................................................................................................................................................. 98
3.6 HCS-4380/82/70/71 series congress unit ..................................................................................................... 105
3.6.1 Functions and indications ........................................................................................................................................ 105
3.6.2 Connection .............................................................................................................................................................. 108
3.6.3 Operation ................................................................................................................................................................ 110
V
3.7 HCS-4360/61/62/63 series congress unit ..................................................................................................... 116
3.7.1 Functions and indications ........................................................................................................................................ 116
3.7.2 Installation ............................................................................................................................................................... 119
3.7.3 Connection .............................................................................................................................................................. 120
3.7.4 Operation ................................................................................................................................................................ 122
3.8 HCS-4338N/50 series congress unit ............................................................................................................ 126
3.8.1 Functions and indications ........................................................................................................................................ 126
3.8.2 Connection .............................................................................................................................................................. 128
3.8.3 Operation ................................................................................................................................................................ 130
3.9 HCS-4860/4865/4866 series congress unit .................................................................................................. 134
3.9.1 Functions and indications ........................................................................................................................................ 134
3.9.2 Connection .............................................................................................................................................................. 139
3.9.3 Operation ................................................................................................................................................................ 141
3.10 HCS-4851/50 series congress unit ............................................................................................................. 145
3.10.1 Functions and indications ...................................................................................................................................... 145
3.10.2 Installation ............................................................................................................................................................. 147
3.10.3 Connection ............................................................................................................................................................ 149
3.10.4 Operation .............................................................................................................................................................. 150
3.11 HCS-4330/31/32/33/35 series congres s unit (HCS-4330/50 series) .......................................................... 153
3.11.1 Functions and indications ...................................................................................................................................... 153
3.11.2 Connection ............................................................................................................................................................ 156
3.11.3 Operation ............................................................................................................................................................... 158
3.12 HCS-4325/26/27 series congress unit ........................................................................................................ 162
3.12.1 Functions and indications ...................................................................................................................................... 162
3.12.2 Installation ............................................................................................................................................................. 165
3.12.3 Connection ............................................................................................................................................................ 170
3.12.4 Operation .............................................................................................................................................................. 172
3.13 HCS-4341/50 series congress unit ............................................................................................................. 176
3.13.1 Functions and indications ...................................................................................................................................... 176
3.13.2 Installation ............................................................................................................................................................. 178
3.13.3 Connection ............................................................................................................................................................ 179
3.13.4 Operation .............................................................................................................................................................. 182
3.14 HCS-4841/42/43 series congress unit ........................................................................................................ 185
3.14.1 Functions and indications ...................................................................................................................................... 185
3.14.2 Installation ............................................................................................................................................................. 189
3.14.3 Connection ............................................................................................................................................................ 195
3.14.4 Operation .............................................................................................................................................................. 198
3.15 HCS-4368/50 series wired voting units ....................................................................................................... 202
3.15.1 Functions and indications ...................................................................................................................................... 202
3.15.2 Installation ............................................................................................................................................................. 204
3.15.3 Connection ............................................................................................................................................................ 205
3.15.4 Operation .............................................................................................................................................................. 206
3.16 HCS-1080 Series E-ink Nameplate ............................................................................................................ 209
3.16.1 Functions and indications ...................................................................................................................................... 209
3.16.2 Installation ............................................................................................................................................................. 210
3.16.3 Connection ............................................................................................................................................................ 211
3.16.4 Operation .............................................................................................................................................................. 213
VI
Chapter 4: Interpreter unit ...................................................................................................... 214
4.1 HCS-4385U/50 .............................................................................................................................................. 215
4.1.1 Functions and indications ........................................................................................................................................ 215
4.1.2 Installation ............................................................................................................................................................... 218
4.1.3 Connection .............................................................................................................................................................. 219
4.1.4 Setup ....................................................................................................................................................................... 221
4.1.5 Operation ................................................................................................................................................................ 226
4.2 HCS-8385/60 ................................................................................................................................................ 228
4.2.1 Functions and indications ........................................................................................................................................ 228
4.2.2 Installation ............................................................................................................................................................... 231
4.2.3 Connection .............................................................................................................................................................. 232
4.2.4 Setup ....................................................................................................................................................................... 234
4.2.5 Operation ................................................................................................................................................................ 239
4.2.6 HCS-8385HDMI ...................................................................................................................................................... 241
Chapter 5 System connection and basic setup procedure ..................................................... 243
5.1 System connection ........................................................................................................................................ 243
5.1.1 Connection principles .............................................................................................................................................. 243
5.1.2 Connection between the CMU/EMU and the contribution units ............................................................................... 248
5.1.3 Connection between the CMU/EMU and component contribution units .................................................................. 249
5.1.4 Connection between HCS-4100/50 system and automatic video tracking system .................................................. 250
5.1.5 Connection between HCS-4100/50 system and digital infrared language distri bution system ................................ 251
5.1.6 Connection between HCS-4100/50 system and network central control system .................................................... 253
5.1.7 Connection between HCS-4100/50 system and Conference Sign-in System ......................................................... 254
5.1.8 Combine/split congress rooms easily ...................................................................................................................... 255
5.1.9 Total system hot spare ............................................................................................................................................. 256
5.2 Basic configuration of a congress system .................................................................................................... 257
Chapter 6 Peripheral equipment and accessories .................................................................. 259
6.1 Microphone ................................................................................................................................................... 259
6.2 Earphones ..................................................................................................................................................... 261
6.3 Accessories ................................................................................................................................................... 262
Chapter 7 Working environment and maintenance ................................................................ 264
7.1 Public areas .................................................................................................................................................. 264
7.2 Technical rooms ............................................................................................................................................ 264
7.3 Interpreter booths .......................................................................................................................................... 264
7.4 System operator room .................................................................................................................................. 265
7.5 Ventilation ..................................................................................................................................................... 265
7.6 Cleaning ........................................................................................................................................................ 265
7.7 Storage.......................................................................................................................................................... 265
Chapter 8 Technical specifications ......................................................................................... 266
8.1 System specifications ................................................................................................................................... 266
8.2 Congress system main unit........................................................................................................................... 267
8.2.1 Congress main unit ................................................................................................................................................. 267
8.2.2 Extension main unit ................................................................................................................................................. 268
VII
8.3 Congress unit ................................................................................................................................................ 269
8.3.1 HCS-48U6 series congress unit .............................................................................................................................. 269
8.3.2 HCS-48U7/U8/U9 series congress unit ................................................................................................................... 271
8.3.3 HCS-48U10 series congress unit ............................................................................................................................ 273
8.3.4 HCS-4886/87/88 series congres s unit ..................................................................................................................... 274
8.3.5 HCS-4380/82/70/71 series congr es s unit ................................................................................................................ 275
8.3.6 HCS-4360/61/62/63 series congress unit ................................................................................................................ 276
8.3.7 HCS-4338N/50 series congress unit ....................................................................................................................... 277
8.3.8 HCS-4860/4865/4866 series congress unit ............................................................................................................. 278
8.3.9 HCS-4851/50 series congress unit .......................................................................................................................... 280
8.3.10 HCS-4330/31/32/33/35 series congress unit ......................................................................................................... 281
8.3.11 HCS-4325/26/27 series congress unit ................................................................................................................... 283
8.3.12 HCS-4341/50 series congress uni t ........................................................................................................................ 285
8.3.13 HCS-4340/50 series multi-func tion connector ....................................................................................................... 286
8.3.14 HCS-4841/42/43 series congres s unit ................................................................................................................... 287
8.3.15 HCS-4368/50 series wired votin g unit ................................................................................................................... 290
8.3.16 HCS-1080 series electronic nam eplate ................................................................................................................. 291
8.4 Interpreter unit ............................................................................................................................................... 292
8.4.1 HCS-4385U/50 ........................................................................................................................................................ 292
8.4.2 HCS-8385/60 .......................................................................................................................................................... 293
8.4.3 HCS-8385HDMI ...................................................................................................................................................... 294
8.5 Peripheral equipment and accessories ......................................................................................................... 295
8.5.1 Pluggable stem microphone .................................................................................................................................... 295
8.5.2 Earphone ................................................................................................................................................................. 296
8.5.3 Accessories ............................................................................................................................................................. 298
8.6 System connection ........................................................................................................................................ 299
8.6.1 Mains cables ........................................................................................................................................................... 299
8.6.2 Audio cables ............................................................................................................................................................ 299
8.6.3 Earphone ................................................................................................................................................................. 299
8.7 Display language list ..................................................................................................................................... 300
AppendixCustom-made cable ............................................................................................. 301
Appendix: Dedicated 6 PIN Extension Cable .................................................................................................. 301
VIII
Installation & User Guide
About this manual
This manual is a comprehensive guide to the installation and operation of
the TAIDEN HCS-4100/50
Fully Digital Congress System. It includes the detailed description of the functions and interfaces of the HCS-4100/50 system components, system connection and installation, system set-up and operation.
The manual is divided into the following chapters:
Chapter 1
Introduction
An introduction to the HCS-4100/50 system composition, technology, functions and features.
Chapter 2
Congress main unit
Detailed descriptions of the functions and indications, installation and connection, configuration and operation of the HCS-4100/50 congress main unit (CMU) and extension main unit (EMU).
Chapter 3
Congress unit
Detailed descriptions of the functions and indications, installation and connection, configuration and operation of the HCS-4100/50 series discussion units and the voting units.
Chapter 4
Interpreter unit
Detailed descriptions of the functions and indications, installation and connection, configuration and operation of the HCS-4385U/50 interpreter unit.
Chapter 5
System connection and basic
configuration
Detailed descriptions of the connection between system devices. An example is taken to introduce the basic configuration of the congress system.
Chapter 6
Peripheral equipment and accessories
An introduction to the HCS-4100/50 peripheral equipment and the accessories, e.g. stem microphones, earphones, etc.
Chapter 7
Environment and maintenance
An introduction to the work environment and the maintenance of HCS-4100/50 system.
Chapter 8
Specifications
Main technical parameters of HCS-4100/50 system.
IX
Installation & User Guid e
This manual is applicable to:
Congress main units HCS-4100MA/50
Fully Digital Congress System Main Unit (discussion, voting, 64 CHs, multi-mode optical fiber interface)
HCS-4100MA/FS/50
Fully Digital Congress System Main Unit (discussion, voting, 64 CHs, single-mode optical fiber interface)
HCS-4100MB/50
Fully Digital Congress System Main Unit (discussion, voting, 64 CHs)
HCS-4100MC/50
Fully Digital Congress System Main Unit (discussion, voting)
HCS-8300ME/FS
Fully Digital Congress System Extension Main Unit (with 2 single-mode optical fiber interfaces)
HCS-8300ME
Fully Digital Congress System Extension Main Unit
Congress units HCS-48U6 series congress units:
HCS-48U6CMICM
Fully Digital Congress System Chairman Unit (flush-mounting, HCS-48U6DVOT and HCS-48U6SPK can be connected, black)
HCS-48U6DMICM
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-48U6DVOT and HCS-48U6SPK can be connected, black)
HCS-48U6CMICS
Fully Digital Congress System Chairman Unit (flush-mounting, HCS-48U6SELM needed, black)
HCS-48U6DMICS
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-48U6SELM needed, black)
HCS-48U6SELM
Flush-mounting 64-Channel Selector (HCS-48U6MICS, HCS-48U6DVOT and HCS-48U6SPK can be connected, black)
HCS-48U6DVOTTW
Fully Digital Voting Unit (flush-mounting, 3 voting keys, contactless IC-Card reader, HCS-48U6SELM or HCS-48U6MICM needed, black)
HCS-48U6DVOTFW
Fully Digital Voting Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, HCS-48U6SELM or HCS-48U6MICM needed, black)
HCS-48U6SPK
Flush-mounting Loudspeaker Panel (HCS-48U6SELM or HCS-48U6MICM needed, black)
HCS-48U7 series congress units: HCS-48U7CMIC
Fully Digital Congress System Chairman Unit (flush-mounting, black)
HCS-48U7DMIC
Fully Digital Congress System Delegate Unit (flush-mounting, black)
HCS-48U7CVOTF
Fully Digital Voting System Chairman Unit (flush-mounting, 5 voting keys, 256x32 LCD, contactless IC-Card reader, black)
HCS-48U7CVOTFN/52
Fully Digital Voting System Chairman Unit (flush-mounting, 5 voting keys, 256x32 LCD, contactless IC-Card reader, can be connected with E-ink electronic nameplate, black)
HCS-48U7DVOTF
Fully Digital Voting System Delegate Unit (flush-mounting, 5 voting keys, 256x32 LCD, contactless IC-Card reader, black)
HCS-48U7DVOTFN/52
Fully Digital Voting System Delegate Unit (flush-mounting, 5 voting keys, 256x32 LCD, contactless IC-Card reader, can be connected with E-ink electronic nameplate, black)
HCS-48U7SEL
Flush-mounting 64-channel Selector (black)
HCS-48U7SPK
Flush-mounting Loudspeaker Panel (black)
HCS-48U7CMICSPK
Fully Digital Congress System Chairman Unit (flush-mounting, black)
HCS-48U7DMICSPK
Fully Digital Congress System Delegate Unit (flush-mounting, black)
HCS-4340CU/50
Multi-function Connector (for HCS-48U7 series, for connec tion to 1 chairman unit + 1 loudspeaker, black)
HCS-4340CUN/52
Multi-function Connector (for HCS-48U7 series, for connec tion to 1 chairman unit + 1 loudspeaker, can be connected with E-ink electronic nameplate, black)
HCS-4340DU/50
Multi-function Connector (for HCS-48U7 series, for connec tion to 1 delegate unit + 1 loudspeaker, black)
X
Installation & User Guid e
HCS-4340DUN/52
Multi-function Connector (for HCS-48U7 series, for connec tion to 1 delegate unit + 1 loudspeaker, can be connected with E-ink electronic nameplate, black)
HCS-48U8 series congress units: HCS-48U8CFF
Fully Digital Congress System Chairman Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, black)
HCS-48U8CFFN/52
Fully Digital Congress System Chairman Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, can be connected with E-ink electronic nameplate, black)
HCS-48U8DFF
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, black)
HCS-48U8DFFN/52
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, can be connected with E-ink electronic nameplate, black)
HCS-48U9 series congress units: HCS-48U9CFF
Fully Digital Congress System Chairman Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, black)
HCS-48U9CFFN/52
Fully Digital Congress System Chairman Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, can be connected with E-ink electronic nameplate, black)
HCS-48U9DFF
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, black)
HCS-48U9DFFN/52
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, can be connected with E-ink electronic nameplate, black)
HCS-48U9DVP
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 256x32 LCD, black)
HCS-48U10 series congress units: HCS-48U10CVS
Fully Digital Congress System Chairman Unit (flush-mounting, 3 voting keys, contactless IC-Card reader, 64 CHs, OLED, black)
HCS-48U10CVSN
Fully Digital Congress System Chairman Unit (flush-mounting, 3 voting keys, contactless IC-Card reader, 64 CHs, OLED, Electronic Nameplate can be connected ,black)
HCS-48U10DVS
Fully Digital Congress System Delegate Unit (flush-mounting, 3 voting keys, contactless IC-Card reader, 64 CHs, OLED, black)
HCS-48U10DVSN
Fully Digital Congress System Delegate Unit (flush-mounting, 3 voting keys, contactless IC-Card reader, 64 CHs, OLED, Electronic Nameplate can be connected ,black)
HCS-48U10DV
Fully Digital Congress System Delegate Unit (flush-mounting, 3 voting keys, contactless IC-Card reader, black)
HCS-48U10DDS
Fully Digital Congress System Delegate Unit (flush-mounting, 64 CHs, 2 channel selectors, OLED, dual IDs, black)
HCS-48U10DS
Fully Digital Congress System Delegate Unit (flush-mounting, 64 CHs, OLED, black)
HCS-4886/87/88 series congress units: HCS-4886CW/50
HCS-4886CW/52
Fully Digital Congress System Chairman Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD)
HCS-4886CWN_G/52
Fully Digital Congress System Chairman Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, can be connected with E-ink electronic nameplate)
HCS-4886DW/50 HCS-4886DW/52
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD)
HCS-4886DWN_G/52
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, can be connected with E-ink electronic nameplate)
HCS-4887DW/50 HCS-4887DW/52
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys, contactless IC-Card reader, 256x32 LCD)
XI
Installation & User Guid e
HCS-4888DE/50 HCS-4888DE/52
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys)
HCS-4886NX_S/50 HCS-4886NX_G/52
Fully Digital Congress System Operator Unit (tabletop, 256x32 LCD, for intercom/external communication)
HCS-4380/82/70/71 series congress units: HCS-4380SCW/50
Fully Digital Congress System Chairman Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, charcoal gray)
HCS-4380SDW/50
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, charcoal gray)
HCS-4382SD/50
Fully Digital Congress System Delegate Unit (tabletop, 5 voti ng keys, 256x32 LCD, charcoal gray)
HCS-4370SDWE/50
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys, contactless IC-Card reader, 64 CHs, charcoal gray)
HCS-4371SD/50
Fully Digital Congress System Delegate Unit (tabletop, charcoal gray)
HCS-4360/61/62/63 series congress units: HCS-4360CWE/50
Fully Digital Congress System Chairman Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, cover, charcoal gray)
HCS-4360DWE/50
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs, cover, charcoal gray)
HCS-4361DE/50
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, cover, charcoal gray)
HCS-4362D/50
Fully Digital Congress System Delegate Unit (flush-mounting, 64 CHs, cover, charcoal gray)
HCS-4363D/50
Fully Digital Congress System Delegate Unit (flush-mounting, cover, charcoal gray)
HCS-4338N series congress units: HCS-4338NCVS/50
Fully Digital Congress System Chairman Unit (tabletop, 3 voting keys, 64 CHs, OLED)
HCS-4338NDVS/50
Fully Digital Congress System Delegate Unit (tabletop, 3 voting keys, 64 CHs, OLED)
HCS-4338NDV/50
Fully Digital Congress System Delegate Unit (tabletop, 3 voting keys)
HCS-4338NCS/50
Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, OLED)
HCS-4338NDS/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, OLED)
HCS-4338NC/50
Fully Digital Congress System Chairman Unit (tabletop)
HCS-4338ND/50
Fully Digital Congress System Delegate Unit (tabletop)
HCS-4338NDDS/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, 2 channel selectors, dual IDs) Note: At choic e for all discussion units of this series: charcoal
gray panel or champagne panel.
HCS-4860 series congress units: HCS-4860CVE/50
Fully Digital Congress System Chairman Unit (tabletop, 3 voting keys)
HCS-4860DVE/50
Fully Digital Congress System Delegate Unit (tabletop, 3 voting keys)
HCS-4860CS/50
Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, OLED)
HCS-4860DS/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, OLED)
HCS-4860C/50
Fully Digital Congress System Chairman Unit (tabletop)
HCS-4860D/50
Fully Digital Congress System Delegate Unit (tabletop) Note: At choice for all congress units of this series: black, gold or .
silver microphone + black base.
XII
Installation & User Guid e
HCS-4860/2M series congress units: HCS-4860CS/50/2M
Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, OLED, rectangular columnar metal microphone, main microphone + backup microphone, silver microphone + black base)
HCS-4860DS/50/2M
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, OLED, rectangular columnar metal microphone, main microphone + backup microphone, silver microphone + black base)
HCS-4860C/50/2M
Fully Digital Congress System Chairman Unit (tabletop, rectangular columnar metal microphone, main microphone + backup microphone, silver microphone + black base)
HCS-4860D/50/2M
Fully Digital Congress System Delegate Unit (tabletop, rectangular columnar metal microphone, main microphone + backup microphone, silver microphone + black base)
HCS-4865 series congress units: HCS-4865CVE/50
Fully Digital Congress System Chairman Unit (tabletop, 3 voting keys)
HCS-4865DVE/50
Fully Digital Congress System Delegate Unit (tabletop, 3 voting keys)
HCS-4865CS/50
Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, OLED)
HCS-4865DS/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, OLED)
HCS-4865C/50
Fully Digital Congress System Chairman Unit (tabletop)
HCS-4865D/50
Fully Digital Congress System Delegate Unit (tabletop)
HCS-4866 series congress units: HCS-4866CVE/50
Fully Digital Congress System Chairman Unit (tabletop, 3 voting keys)
HCS-4866DVE/50
Fully Digital Congress System Delegate Unit (tabletop, 3 voting keys)
HCS-4866CS/50
Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, OLED)
HCS-4866DS/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, OLED)
HCS-4866C/50
Fully Digital Congress System Chairman Unit (tabletop)
HCS-4866D/50
Fully Digital Congress System Delegate Unit (tabletop)
HCS-4851 series congress units: HCS-4851C/50
Fully Digital Congress System Chairman Unit (flush-mounting, retractable array microphone)
HCS-4851D/50
Fully Digital Congress System Delegate Unit (flush-mounting, retractable array microphone) Note: At choice for all congress units of this series: black or
champagne.
HCS-4330/31/32/33/35 series congress units: HCS-4330CE/50
Fully Digital Congress System Chairman Unit (tabletop, 5 voting keys, IC-Card, 64 CHs)
HCS-4330DE/50
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys, IC-Card, 64 CHs)
HCS-4331CB/50
Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, speech timer indicator)
HCS-4331DB/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, speech timer indicator)
HCS-4332DE/50
Fully Digital Congress System Delegate Unit (tabletop, 5 voting keys)
HCS-4333CB/50
Fully Digital Congress System Chairman Unit (tabletop, speech timer indicator, charcoal gray)
HCS-4333DB/50
Fully Digital Congress System Delegate Unit (tabletop, speech timer & request-to-speak indicator)
HCS-4335D/50
Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, 2 channel selectors, dual predefined positions) Note: this series disc ussion unit has 2 colors available: charcoal
gray and silver.
XIII
Installation & User Guid e
HCS-4325/26/27 series congress units: HCS-4325U/50
Dual 64-Channel Selector (flush-mounting, black)
HCS-4325(N)/50
Dual 64-Channel Selector (flush-mounting)
HCS-4325(N)W/50
Dual 64-Channel Selector (flush-mounting, contactless IC-Card reader)
HCS-4326C(N)WE/50
Fully Digital Congress System Chairman Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs)
HCS-4326(N)DWE/50
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, contactless IC-Card reader, 64 CHs)
HCS-4326(N)DE/50
Fully Digital Congress System Delegate Unit (flush-mounting, 5 voting keys, 64 CHs)
HCS-4327HD/50
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4325/50 or HCS-4326/50 needed, black, handheld microphone)
HCS-4327HDA/50
Fully Digital Congress System Delegate Unit (with fixing clip, HCS-4325/50 or HCS-4326/50 needed, black, handheld microphone)
HCS-4327D/50
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4325/50 or HCS-4326/50 needed, black) Note: HCS-4325/26 series discussion unit has 2 colors available:
charcoal gray and silver.
HCS-4341/50 series congress units: HCS-4341CB/50
Fully Digital Congress System Chairman Unit (boundary, HCS-4340/50 needed, black)
HCS-4341DB/50
Fully Digital Congress System Delegate Unit (boundary, HCS-4340/50 needed, black)
HCS-4341HD/50
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4340/50 needed, black, handheld microphone)
HCS-4841/42/43 series congress units: HCS-4841NC/50
Fully Digital Congress System Chairman Unit (flush-mounting, HCS-4340/50 needed)
HCS-4841ND/50
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4340/50 needed)
HCS-4841CU/50
Fully Digital Congress System Chairman Unit (flush-mounting, HCS-4340/50 needed)
HCS-4841DU/50
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4340/50 needed)
HCS-4841CUA/50
Fully Digital Congress System Chairman Unit (flush-mounting, HCS-4340/50 needed)
HCS-4841DUA/50
Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4340/50 needed)
HCS-4842N/50
64-channel Selector (flush-mounting, HCS-4340/50 needed)
HCS-4842NA/50
64-channel Selector (flush-mounting, HCS-4340/50 needed)
HCS-4843NCTE/50
Fully Digital Voting System Chairman Unit (flush-mounting, 3 voting keys, HCS-4340/50 needed)
HCS-4843NDTE/50
Fully Digital Voting System Delegate Unit (flush-mounting, 3 voting keys, HCS-4340/50 needed)
HCS-4843NCFE/50
Fully Digital Voting System Chairman Unit (flush-mounting, 5 voting keys, HCS-4340/50 needed)
HCS-4843NDFE/50
Fully Digital Voting System Delegate Unit (flush-mounting, 5 voting keys, HCS-4340/50 needed) Note: this series disc ussion unit has 2 colors available: charcoal
gray and silver.
HCS-4368/50 series 5-key voting units: HCS-4368CF/50
Fully Digital V oting System Chairman Unit (tabletop, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V)
HCS-4368DF/50
Fully Digital Voting System Delegate Unit (tabletop, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V)
HCS-4368CFW/50
Fully Digital V oting System Chairman Unit (tabletop, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V, contactless IC-Card reader)
XIV
Installation & User Guid e
HCS-4368DFW/50
Fully Digital Voting System Delegate Unit (tabletop, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V, contactless IC-Card reader)
HCS-4368CF/FM/50
Fully Digital Voting System Chairman Unit (flush-mounting, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V, cover)
HCS-4368DF/FM/50
Fully Digital Voting System Delegate Unit (flush-mounting, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V, cover)
HCS-4368CFW/FM/50
Fully Digital Voting System Chairman Unit (flush-mounting, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V, contactless IC-Card reader, cover)
HCS-4368DFW/FM/50
Fully Digital Voting System Delegate Unit (flush-mounting, 5 voting keys, 256x32 LCD, waterproof, antistatic 12000 V, contactless IC-Card reader, cover) Note: this series tabletop voting unit has red color only; this
series flush-mounted voting unit has 2 colors available: red and silver.
HCS-4340/50 series multi-function connector HCS-4340CAT/50
Multi-function Connector (for connection to 1 chairman unit + 1 3-key voting unit + 1 channel selector, charcoal gray)
HCS-4340CAF/50
Multi-function Connector (for connection to 1 chairman unit + 1 5-key voting unit + 1 channel selector, charcoal gray)
HCS-4340DAT/50
Multi-function Connector (for connection to 1 d elegate unit + 1 3-key voting unit + 1 channel selector, charcoal gray)
HCS-4340DAF/50
Multi-function Connector (for connection to 1 d elegate unit + 1 5-key voting unit + 1 channel selector, charcoal gray)
HCS-4340HDAT/50
Multi-function Connector (for connection to 1 handheld delegate unit+ 1 3-key voting unit + 1 channel selector, charcoal gray)
HCS-4340HDAF/50
Multi-function Connector (for connection to 1 handheld delegate unit+ 1 5-key voting unit + 1 channel selector, charcoal gray)
HCS-4340HDAT/50P
Multi-function Connector (for connection to 1 condenser microphone + 1 3-key voting unit + 1 channel selector, +48 V phantom power, charcoal gray)
HCS-4340HDAF/50P
Multi-function Connector (for connection to 1 condenser microphone + 1 5-key voting unit + 1 channel selector, +48 V phantom power, charcoal gray)
HCS-4340B/50
Multi-function Connector (for connection to 4 pcs of channel selector, charcoal gray)
HCS-4340DT/50
Multi-function Connector (for connection to 2 delegate units+ 2 channel selectors, charcoal gray)
HCS-1080 series E-ink electronic nameplate HCS-1080
E-ink Electronic Nameplate (wired, U7/U8/U9/U10/4886N, HCS-4340UN/52 or HCS-1080T needed, black)
HCS-1080T
E-ink Electronic Nameplate Adapter (4 Electronic Nameplates can be connected)
Interpreter unit HCS-4385U/50
Fully Digital Congress System Interpreter Uni t (64 CHs, IC-Card, 256x64 LCD, microphone, loudspeaker)
HCS-8385/60
Fully Digital Congress System Interpreter Unit (64 CHs, 7.2” TFT LCD, microphone, loudspeaker)
HCS-8385HDMI/02
Video Converter, 2 HDMI outputs
HCS-8385HDMI/04
Video Converter, 4 HDMI outputs
Pluggable microphone MS24EMF1G/S
240 mm pluggable (gray/silver)
MS33EMF1G/S/B
330 mm pluggable (gray/silver/black)
MS41EMF1G/S/B
410 mm pluggable (gray/silver/black)
MS47EMF1G/S/B
470 mm pluggable (gray/silver/black)
Earphone EP-820AS
Single earphone
EP-829
Single earphone
EP-829SW
Single earphone (Built-in magnetic control switch)
EP-960AN
Interpreter headset (for HCS-8385/60)
EP-960AH
Interpreter headset (for HCS-4385U/50)
EP-960BH
Interpreter headphone
HCS-5100PA
Headphone
1
Chapter 1: Introduction
1.1 Summary
By using TAIDEN originated MCA-STREAM (Multi_Channel_Audio STREAM) digital processing and transmitting technologies, HCS-4100/50 Fully Digital Congress System revolutionizes conference systems technology by incorporating the latest fully digital technologies, audio technologies and network techniques. Furthermore, with perfect integration of TAIDEN Conference Sign-in System and Central Control System, HCS-4100/50 system takes the leadership in providing comprehensive and efficient digital conference system solutions. “Closed Loop - Daisy Chain” connection technology, to connect all congress units and simplifying installation, as well as dual connection backup have been opted for. In HCS-4100/50 Fully Digital Congress System, the
congress main unit can realize a “Closed Loop - Daisy Chain” connection, but only one – extension units do not offer this feature. By supporting 48 kHz audio sampling rate, all 64 channels feature a 30 Hz to 20 kHz frequency response. HCS-4100/50 Fully Digital Congress System consists of congress main unit, contribution units and application software. Congress main unit includes the congress control main unit (CMU) and the extension main unit (EMU). Contribution units include discussion units, voting units, simultaneous interpreter units, channel selectors, etc. The application software contains a number of software modules, performing different tasks.
Figure 1.1.1 System overview
2
1.2 System technology
MCA-STREAM digital audio processing and
transmission technology
TAIDEN proprietary MCA-STREAM technology is the essential data transmission technology in the HCS-4100/50 system, e.g. transmitting up to 64 CHs high quality digital, control and other information data over a single dedicated 100 Mbps high speed 6-pin cable. Every unit - congress main unit, congress unit, language distribution unit, interpreter unit - is equipped with a high performance CPU as the kernel of the advanced technology infrastructure.
Figure 1.1.2 Simple and reliable system connection
By virtue of using the MCA-STREAM technology, HCS-4100/50 Fully Digital Congress System carries out: Ease of system cabling and enhancement of system
reliability by utilizing a single dedicated 6-pin cable to transmit up to 64 CHs floor and interpretation language signals, avoiding the necessity to use complicated multi-core cables;
Prevention of noise caused by the ground wire in
stereo projects as well of interference brought by other equipment (such as stage lights, recording apparatus, etc.). SNR reaches 96 dB and isolation is better than 85 dB. The frequency response verges on 30 Hz - 20 kHz; making the system sound excelling CD quality;
Provision of Hi-Fi sound quality, even in long range
transmission, which makes the system widely suitable for various applications such as mini/medium type meeting rooms, large venues, stadiums, etc.
HCS-4100/50 system hardware structure
HCS-4100/50 system hardware is an embedded structure based on dual high performance CPUs. Even in stand-alone mode, HCS-4100/50 system is competent for the management of various meetings via several basic congress management facilities, such as basic microphone management, electronic voting, multilingual simultaneous interpretation, etc. In the figure below: Audio CODEC: Dedicated audio coding and decoding
chip of discussion unit and interpreter unit
TDN: Dedicated digital communication chip for TAIDEN
digital congress system networking
DAC: Digital-to-analog conversion chip RISC: Central processing chipset of congress main
unit, controlling the DSP and AD/DA conversion IC to provide 2-channel audio line in/out and record in/out facilities
Based on advanced hardware, HCS-4100/50 system features high security software, easy to operate, convenient to maintain and to upgrade. The meeting is fully controlled and monitored by the operator.
Figure 1.1.3 HCS-4100/50 system hardware structure
3
Figure 1.1.4 MCA-STREAM data stream format
Modular system structure
Any kind of configuration can be set up just by daisy-chaining HCS-4100/50 fully digital congress units. The modular system structure of HCS-4100/50 is applicable to any kind of congress and provides an accurate and efficient solution. Additional congress units can be added when needed. More system functions are available in connection with a PC and control software.
Dual congress main unit hot spare
HCS-4100/50 dual main unit hot spare is a disaster protective structure. Besides the main unit, the user can set another CMU as backup CMU and connect it to the system. If the main unit breaks down during the conference, the backup main unit substitutes the main unit and the system software will connect to backup CMU automatically, ensuring the consistency of the conference.
HCS-4100/50 system software infr astructure
HCS-4100/50 system software is designed for the prevalent Client/Server structure. Client and server communicate with each other by using TCP/IP network protocol, ensuring both data security and transmission efficiency. Client and server software can run on the same computer as well as on different computers in the same LAN, enabling the operator to manage the congress more flexibly. HCS-4100/50 system software imports the hot-spare dual server structure by using a main server and a back-up server. While the main server is processing, data are stored real time on the back-up server to prevent congress related information from loss in case of a crash of the main server. As a result, security and reliability of the congress system are improved vitally.
Duplicate and backup connection via “Closed
Loop - Daisy Chain” connection
For important meetings, especially those which consider connection reliability as their leading point, HCS-4100/50 Series Fully Digital Congress System adopts advanced “Closed Loop - Daisy Chain” connection topology, connecting the last unit in the loop back to the congress main unit. Therefore, any congress unit in the loop has two connection paths to the congress main unit. As a result, breakdown or replacement of a congress unit and connection failure of a cable will not influence other congress units. As such the system features the advantages of a daisy-chain connection system with its simpleness of cabling as well as the improvement of the system reliability through duplicate and backup connection functions. In HCS-4100/50 series system, the congress main unit can realize a “Closed Loop - Daisy Chain” connection, but only one – extension units do not offer this feature.
Advanced TCP/IP communication protocol in
PC control
In a PC controlled system, the congress main unit and the PC use the advanced TCP/IP protocol. Theoretically, the communication distance between the PC and the CMU can be infinite. This is decisively different to traditional RS-232 connection modes where the distance between the PC and the CMU cannot exceed 15 meters. TCP/IP enables remote control, remote diagnosis and remote update. By using network techniques, congress systems are tightly linked to the rapidly developing internet technology, computer science and communication technology. Users enjoy the convenience of the contemporary leading techniques, e.g. by using the
4
compatible wireless LAN techniques (802.11) - such as PDAs - which can be used to control a conference system wirelessly. The import of network topology also makes the conference system merge with intelligent building networks.
CMU and EMU
The congress main unit forms the core of the entire congress system. It provides power supply to all contribution units and serves as key component to link system hardware to application software. One CMU has two (6P-DIN) trunk-line cable outlets. If more congress units are needed, additional extension main units HCS-8300ME or HCS-8300ME/FS are required, each EMU has four (6P-DIN) trunk-line cable outlets. HCS-4100/50 system maximum capacity: 378 interpreter units (63 interpreter booths, 6 interpreter units in each), 4096 discussion/voting units and any number of channel selectors. In stand-alone mode without a PC, the CMU carries out basic management facilities, simultaneous interpretation, electric voting and 64 CHs digital audio transmission. By operating HCS-4100/50 application software in PC-controlled mode, more comprehensive management facilities can be implemented.
Contribution units
Contribution units are units used by participants to contribute to a conference and include: discussion unit (chairman/delegate), voting unit, interpreter unit, channel selector, etc. The basic contribution unit has discussion, voting or channel select facility. The upgraded units combine discussion, voting and channel select, furthermore built-in loudspeaker, IC-Card reader and graphic 256x32/256x64 LCD with back-lighting, forming a wide variety of product series. The chairman unit has microphone priority facility with a priority button to switch off or to mute speaking units. If required, different functions can be allocated to delegate stations, including listening, discussion, request to speak, voting, IC-Card sign-in, short message, information display, etc. Depending on the option, congress units can be divided into foldaway, tabletop, flush-mounted and component. Each style consists of various products, which significantly enriches users’ choices. Low power consumption design is adopted in
HCS-8300 and HCS-4100/50 series congress units, convenient for wiring and installation. All congress units of HCS-8300 and HCS-4100/50 series (except HCS-8338 and HCS-8348 series) are supplied by the main unit’s 6P-DIN interface. Since the power capacity of the 6P-DIN interface is limited, it must be ensured during installation that the added up values of a) the total power consumption of all congress units connected in each path and b) the power loss in extension cables do in no case exceed the maximum possible value delivered by each 6P-DIN interface. Otherwise the system will not work properly or automatic protection will be triggered. (see section
5.1.1
for details).
Application software
HCS-4100/50 application software is comprehensive, reliable and user-friendly. It is also an easy-care software system which helps the operator to manage the conference efficiently from the very beginning of a meeting until the post-meeting work. Once the PC installed and the HCS-4100/50 application software integrated into the HCS-4100/50 system, the operator manages all aspects of the conference centrally. The operation turns out to be easy and efficient. HCS-4100/50 application software is modular software with various functional modules: System Setup Management Module, Microphone Management Module, Voting Management Module, Simultaneous Interpretation Module, Intercom Software Module, Synchronous Audio Recording Management Module, Multi-User Conference Control Management Module, Dual PC Server Hot Spare Module, Agenda Control Module, Dual System Main Unit Hot Spare Module, etc.
5
Installation and transportation
Easy installation is another vital feature of HCS-4100/50 Series Fully Digital Congress System. All HCS-4100/50 series digital congress units are equipped with a 1.5-meter - 6P-DIN cable (with a male connector) and a 0.6-meter - 6P-DIN cable (with a female connector) except HCS-4330/50 series which has a 2.1-meter - 6P-DIN cable (with a male connector) and a socket on the housing. All congress units are connected together in a daisy chain configuration and connected to the main unit by the dedicated extension cable.
6
1.3 Functions
 Discussion
“Active microphones” (1/2/3/4), sets the number
of delegates permitted to speak at the same time, and sets speaking time limit function
Five discussion modes:
“Open” mode, microphone On/Off button with
request-to-speak registration (AUTO)
“Override” mode, microphone On/Off button
control with override of the active delegate microphones (FIFO)
“Voice” mode, acoustic active sensitivity and
automatic switch-off time adjustable continuously, built-in “flash-on” technology, immediate microphone activation on speaking
“Apply” mode, delegate applies to speak by
pressing microphone On/Off button, delegate only speaks when operator or chairman approved his application
“PTT” mode, press microphone On/Off button
to talk
VIP unit configurable:
By using TAIDEN conference management
system software, a maximum of 32 delegate units can be set as VIP units
VIP unit can be activated in any mode freely,
as long as the active microphone capacity is not full
Gain and EQ (5 band) of each microphone
adjustable separately, fitting the individual orator’s voice to achieve perfect speech pickup any time
Integrated high-pass filter (low-cut switch) to cut
low frequency elements from the audio when needed
64 CHs simultaneous interpretation
Supporting 48 kHz audio sampling rate, all 64
channels with a frequency response of 30 Hz - 20 kHz
HCS-4100/50 system can accommodate 378
interpreter units (63 interpreter booths, 6 interpreter units in each), and provide 64 CHs (including floor language) simultaneous interpretation
The interpreter unit is equipped with a
uni-directional electret condenser microphone. The gain of each microphone is adjustable, and with auto gain control. It features also 5 pre-defined input channels and 3 output interpretation channels with their corresponding short keys, a high-contrast 256×64 graphic LCD with back-lighting, a built-in IC-Card reader as well as an audio record & playback function
Delegates use channel select to listen to different
languages. In cooperation with channel selectors and/or infrared language distribution system, a larger listening audience is enabled to join the meeting
Voting
If the system is equipped with a chairman unit
with a graphic LCD, parliamentary voting (YES/NO/ABSTAIN) can be implemented even without a PC. The result is displayed on the LCD of every contribution unit.
Cooperating with corresponding software
modules, multiform voting can be implemented:
For/Against Parliamentary: YES/NO/ABSTAIN Multiple choice/Opinion poll: 1/2/3/4/5 Audience response/Rating: --/-/0/+/++ Parliamentary (NPPV):
YES/NO/ABSTAIN/NPPV
Appraisal:
Satisfied (Four options: perfectly satisfied,
satisfied, basically satisfied, unsatisfied) (Three options: satisfied, basically satisfied, unsatisfied)
(Two options: satisfied, unsatisfied) Qualified (2/3/4 options) Competent (2/3/4 options)
7
Information display
By using the information display module of the
TAIDEN conference management system software, congress title, content, congress related information as well as meeting related notice can be displayed on a large screen display (or projector)
Contribution units equipped with graphic 256x32
LCD show:
Active microphone amount, request amount,
delegates’ signed-in and voting results, etc.
Messages Multilingual (simplified/traditional Chinese and
English, etc.) menu
Automatic video tracking system
Automatic video tracking can be carried out if video switch unit and camera are installed.
Remote control and remote diagnosis
Using advanced TCP/IP network protocol in the communication between the PC and the CMU - to implement remote control, remote diagnosis and remote update for the congress system - for easy central control of a multi-room configuration.
Intercom
If an operator unit is in the system, the built-in intercom facility allows bidirectional vocal communication between congress participants, interpreters and operators. Extra equipment is not required.
Multi-room configuration function
Several main units can be operated as several independent congress systems or be combined together easily as a large multi-room congress system configuration.
Integrated optical fiber interface
Optical fiber interface is integrated into the HCS-4100MA/FS/50 congress main unit, in cooperation with HCS-8300 series extension main unit, audio input interface or audio output device. Thus several mutually distant congress rooms can be combined and be operated as one venue.
Dual connection backup is implemented between the HCS-4100MA/FS/50 congress main unit and the HCS-8300ME/FS extension main unit via optical fiber and Cat.5 cable.
Seamlessly Integrated with Conference
Sign-in System and the Central Control System
The seamless integration of HCS-4100/50 Series Fully Digital Congress System wit h the TAIDEN Conference Sign-in System and the Central Control System provides comprehensive congress system solutions. Besides the basic congress management (discussion, voting, simultaneous interpretation, video tracking, etc.), it also provides congress sign-in and access control for the congress participants. Furthermore, it gives complete facilities to manage the congress system’s power supply and the peripheral multimedia equipment, surrounding lights, projector display and sound equipment. The easy incorporation of peripheral components upgrades the system into an advanced intelligent congress system with integrated solutions for conferencing, audio, lighting control etc.
Fully compatible with TAIDEN HCS-8300
Series New Generation Paperless Multi-media Congress System
Full compatibility also with TAIDEN HCS-8300 Series New Generation Paperless Multi-media Congress System: HCS-8300 series congress units can be connected to the HCS-4100/50 system, and HCS-4100/50 series congress units can be connected to the HCS-8300 system (exclusive functions are only available with HCS-8300 contribution units).
 Other facilities
With the 8 channel digital/analog audio output
device (several units cascadable), multi-channel digital/analog audio signals are available as output signals for the infrared language distribution system or for recording
Built-in self-detecting functions in each
contribution unit for automatic detection of microphone and keys
8
1.4 Features
System reliability
System reliability , as described below, has always been the guiding principle while designing HCS-4100/50 Fully Digital Congress System:
Dual congress main unit hot spare System software imports the hot-spare dual
server structure by operating the main server and the back-up server at the same time
Dual connection backup is implemented between
the HCS-4100MA/FS/50 congress main unit and the HCS-8300ME/FS extension main unit via optical fiber and Cat.5 cable
“Closed Loop - Daisy Chain” connection topology:
breakdown or replacement of a congress unit and connection failure of a cable will not influence other congress units
Built-in communication auto termination function
to prevent system collapse if the TCP/IP cable is pulled out
Auto recovery function, supports PnP If PC malfunction happens, the CMU will return to
control status automatically and take over control of the meeting, ensuring continuation of the meeting process
System technological progress
HCS-4100/50 Fully Digital Congress System - based on T AIDEN originated independent intellectual property rights digital processing and transmitting technologies MCA-STREAM - adopts em bedded hardware structure based on high performance dual CPU. TAIDEN conference management system software is based on Client/Server and hot-spare dual server structure. CMU and PC use advanced TCP/IP protocol for communication, perfectly integrated to benefit from modern technologies. Furthermore, Conference Sign-in System and Central Control System can be integrated into TAIDEN HCS-4100/50 Fully Digital Congress System to provide the first complete and efficient solution in the world.
System operability
CMU controls efficiently: basic microphone control, simultaneous interpretation, video tracking, voting ­without the intervention of an operator.
With a PC and TAIDEN conference management system software, more functions can be achieved, including enhanced microphone control, simultaneous interpretation, delegate information management, sign-in control, meeting data management and distribution, voting control and output audio processing. TAIDEN conference management system software can also be set up according to user requirements. TAIDEN conference management system software adopts Client/Server structure - the process of the meeting is controlled by the operator from any PC within the same LAN. If PC malfunction occurs, CMU will return to control status automatically and take over control of the meeting, ensuring continuation of the meeting.
Fine extensibility
The interpreter unit of HCS-4100/50 has a maximum of 64 channels (including floor channel) and satisfies the requirements of large-scale international meetings: allocating a language for each channel, selecting a channel, interlock facility. To avoid reciprocal interference and crosstalk the language of each channel can be released separately. The system supports a maximum of 4096 congress units and an infinite number of channel selectors. HCS-4100/50 system is modular: just daisy-chain HCS-4100/50 units to set-up a configuration. If extra system capacity is needed, units can be connected easily, starting from any access point.
Economical and convenient installation
In virtue of the fully digital techniques of HCS-4100/50 system, system installation becomes simple and economical, especially in conjunction with the economical and durable HCS-4100/50 system dedicated 6-PIN cable (substitutable by shielded Cat.5 cable). The cable, suitable for the requirements of any kind of meeting, transmits up to 64 high quality audio signals, control data and information simultaneously. Every delegate unit is assigned an individual ID for convenient setup and perpetual prevention of double ID.
9
System connection reliability is improved by the professional 6P-DIN standard plug and clasp which facilitates system installation as well as disassembly. As a result of the daisy-chain design of the contribution units, insertion into the system can be done at any desired point, simplifying equipment extension and maintenance significantly.
System maintenance
TAIDEN application software provides testing functions for online testing the operating conditions such as validity of the keys, LCD and microphones. A detailed test report is issued for quick and simple maintenance of the system device.
10
Chapter 2: Congress main unit (CMU)
The Congress Main Unit (CMU) forms the core of the HCS-4100/50 Fully Digital Congress System, and provides power supply to all contribution units, meanwhile, serving as the key component to link up hardware with application software. In stand-alone mode without a PC, the CMU only carries out basic management facilities; while more comprehensive management facilities can be implemented in PC-controlled mode. The devices that can be controlled by CMU includes: discussion units (chairman unit/delegate unit), voting units, interpreter units, channel selectors and video switcher for a utomatic video tracking, etc. By cascade connecting EMUs, the HCS-4100/50 system can reach its maximum capacity: 378 interpreter units, 4096 discussion/voting units and an infinite number of channel selectors.
Product types: HCS-4100MA/50
Fully Digital Congress System Main Unit (discussion, voting, 64 CHs, multi-mode optical fiber interface)
HCS-4100MA/FS/50
Fully Digital Congress System Main Unit (discussion, voting, 64 CHs, single-mode optical fiber interface)
HCS-4100MB/50
Fully Digital Congress System Main Unit (discussion, voting, 64 CHs)
HCS-4100MC/50
Fully Digital Congress System Main Unit (discussion, voting)
HCS-8300ME/FS
Fully Digital Congress System Extension Main Unit (with 2 single-mode optical fiber interfaces)
HCS-8300ME
Fully Digital Congress System Extension Main Unit
11
2.1 Fully Digital Congress System Main Unit
2.1.1 Functions and instructions
2.1.1.1 Front panel
Figure 2.1.1 Front panel of HCS-4100M/50 CMU
Figure 2.1.1
1. Power light
a. Switches to red in standby mode; b. Switches to blue when operating.
2. “STANDBY” button
3. “MENU” button
a. The LCD displays the initial
user interface: press
this button to enter the LCD set-up
menu;
b. The LCD displays the set-up
user interface: press this button to select the highlighted item or enter the submenu;
c. The LCD displays the network
configuration: press
this button to select/deselect the numeric value.
4. “
” (Left) button
In standby state, press this button to display
current input audio spectrum;
In the set-up interface of the LCD menu, press this
button to cursor to the left.
5. “
” (Right) button
In standby state, press this button to select the
number of maximum active microphones;
In the set-up interface of the LCD menu, press this
button to cursor to the right.
6. “EXIT” button In standby state, press this button to select the
operation mode of the microphones;
In the set-up interface of the LCD menu, press this
button to exit current menu.
7. LINE IN 1 Vol.
Electric level adjustment knob
8. A type USB interface
To plug-in a USB stick.
9. Mini USB interface
For connecting to PC.
10. “MASTER VOLUME”
Knob to adjust the master volume of the floor
audio channel for the congress units.
11. Monitoring earphone interface
Earphone jack (Ø 3.5 mm).
12. Microphone operation mode indicator (“OPEN” /“OVERRIDE”/“VOICE”/“APPLY”/“PTT.”)
Corresponding indicator lights up according to
selected mode.
13. Menu display
256×32 LCD displays main unit status and
configuration menu.
12
2.1.1.2 Backside
Rear panel of HCS-4100MA/50 CMU
Rear panel of HCS-4100MA/FS/50 CMU
Rear panel of HCS-4100MB/50 and HCS-4100MC/50 CMU
Figure 2.1.2 Rear panel of HCS-4100M/50 CMU
Figure 2.1.2
14. Fiber interface
HCS-4100MA/50: multi-mode optical fiber, SC
connector;
HCS-4100MA/FS/50: single-mode optical fiber,
SC conector;
Connecting the conference main units of several
distant conference rooms to combine as one conference room (bridging distance can reach tens of kilometers).
15. Ethernet interface (LAN)
For communication between the conference main
unit and the PC under TCP/IP protocol to realize remote controlling; furthermore, it enables remote controlling by wireless touch panel through central control system.
16. Extension interface
To connect CMU to EMU and interconnect with
audio input interface and audio output device; devices cascadable.
17. Contribution units ring connection LED
When output works properly ( 1 contribution unit
connected), LED will flash;
When no contribution unit is connected, LED is off.
18. Contribution units output interface (1-2, two routes)
19. Video switcher interface
When cooperating with video switcher and dome
camera, auto video tracking can be realized.
20. Fire alarm linked trigger interface
+5 V voltage application: all congress units will
be switched off and display “ALARM”;
No voltage input or too low voltage: congress
units will return to the status preceding “ALARM”.
21. Power supply
22. Mains switch
23. “LINE OUT 2” (RCAx2 unbalanced output)
24. “LINE OUT 1” (3-cord XLR balanced output)
25. “LINE IN 2” (RCAx2 unbalanced input)
26. “LINE IN 1” (3-cord XLR balanced input)
13
27. RS-232C port x 2
“COM” port is used for connecting to a central
control system for central controlling, as well as for system diagnosis;
“TEST” port is used for updating and monitoring.
2.1.2 Installation
The CMU can be fixed in a standard 19-inch cabinet. The CMU is equipped with a pair of fixing brackets . First unscrew the lateral screws from the housing. Then fasten the brackets with these screws and put the CMU in the cabinet. Finally fix the four holes up with screws.
Figure 2.1.3 Installation of the CMU
In addition, 1U metal stripes are included as decoration to be installed between the CMUs in the cabinet. It is also good for the ventilation and cooling off. Fix up the four holes ③ with screws.
Figure 2.1.4 Decoration of cabinet
14
2.1.3 Connection
2.1.3.1 To congress units
HCS-4100/50 series CMU has 2 outlet (6P-DIN) trunk-line cable sockets for connecting to congress units. HCS-4100/50 series congress units are equipped with a cable with a standard 6P-DIN male connector. When connecting the CMU to the congress units, just connect the male connector of the first unit to the socket of the CMU. For a longer distance between the congress unit and the CMU(EMU), CPL6PS extension cable can be used. One end of this cable is equipped with a 6P-DIN male connector, and the opposite end with a female connector. Just connect the female connector of the cable to the next congress unit, and connect the male connector to the output of the main unit.
Figure 2.1.5 Congress unit connected t o the CMU/EMU
For “Closed Loop - Daisy Chain” connection, just connect the last congress unit back to the CMU via a CBL6PP extension cable (both ends of this cable are equipped with a 6P-DIN male connector). In HCS-4100/50 system, the congress main unit can realize a “Closed Loop - Daisy Chain” connection, but only one – extension units do not offer this feature.
Figure 2.1.6 “Closed Loop - Daisy Chain” connection
topology
Each outlet connector of the HCS-4100/50 CMU can output 60W. Since the power capacity of a 6P-DIN interface is limited, it must be ensured that, during the installation, the sum of the total power consumption of all the congress units connected to every single 6P-DIN interface plus the power loss in the extension cables does not surpass the power limit of each 6P-DIN interface. Otherwise the system will not work properly or automatic protection will occur (see section
5.1.1
for details).
2.1.3.2 To PA
The CMU of the HCS-4100/50 system has a pair of RCA symmetrical audio outputs “LINE OUT 2” and a 3-cord XLR balanced output “LINE OUT 1”, to be connected to a PA. Connecting the RCA symmetrical audio outputs or the 3-cord XLR balanced output of the CMU to the input port of the PA via an audio wire.
15
a. RCA audio output to PA
b. 3-cord XLR balanced output to PA
Figure 2.1.7 CMU connecting to PA
2.1.3.3 To fiber device
HCS-4100MA/50 has a pair of fiber interfaces, and can be connected to the HCS-4100MA/50, HCS-8300 series CMU/EMU, to the Audio Input Interface and to the Audio Output Device. Two distant meeting rooms (distance can reach tens of kilometers) can be combined as one meeting room. The connection between the fiber interfaces is shown in the following figure:
Fiber equipment 1 Fiber equipment 2
Figure 2.1.8 Connecting between CMUs via fiber cable
Loading...