Tahoe TI9000LXU Operation Instructions And Parts Manual

- 1 -
- 2 -
Contents
1. Safety Point for Attention......................................................................................................................................................................................1
2. Parts & Subassemblies ..........................................................................................................................................................................................2
4. Starting of generator..............................................................................................................................................................................................6
5. Usage of Generator................................................................................................................................................................................................9
6. Stopping of generator..........................................................................................................................................................................................12
7. Maintenance .........................................................................................................................................................................................................13
8. Storage...................................................................................................................................................................................................................16
9. Troubleshooting....................................................................................................................................................................................................17
10. Technical data.....................................................................................................................................................................................................19
11. Battery Unit........................................................................................................................................................................................................20
12. Wheel Unit..........................................................................................................................................................................................................23
13. Automatically Gasoline Generator Manual.....................................................................................................................................................27
- 1 -
1. Safety Point for Attention
1) Do not use it indoors 2) Do not open it in wet 3) Do not connect it to the line for house Environment appliance
4) keep flammables 1m 5) Do not overfill to cause over­ Min. away from it flowing while fueling
6) Do not smoke while fueling 7)Stop the engine on fueling
- 2 -
2.. Parts & Subassemblies
1) Fuel indicator 9)Starting handle
2)Fuel tank up 10)Fuel filter cup
3)AC socket 11)Fuel valve
4)AC breaker 12)Air filter
5)Voltmeter 13)Choke handle
6)Machine oil plug gap 14)Exhaust silencer
7)Engine switch 15) Spark plug
8)Discharging bolt 16)Grounding terminal
- 3 -
3.. Check-ups before Operation
····Scope of temperature the genertor set is appli­Cable for.-15
555℃℃℃
℃ to 40
to 40 to 40
to 40℃℃℃℃....
·
··
·Scope of humidity the generator is applicable
For Not over 95%.
·
··
·The generator will output the rated power when
Running in areas within 1000m above the sea level but Lower power than that in areas higher than 1000m above The sea level.
1. Level of machine oil
Caution: Remember that check-ups must be carried Out on an even ground with the engine stopped. A. Insert the oil plug gage into the machine oil filling
HHHHole without turning and check the oil level.
ole without turning and check the oil level.ole without turning and check the oil level.
ole without turning and check the oil level.
B. When the oil level is too lower,refill the machine with machine Oil but not over the upper limit mark. Recommended machine oil: Machine oil Class SE or SF of API of SAE10W-30 Corresponding to Class SG C. Remount the machine oil plug gage securely.
- 4 -
2
..
Level of fuel
A. Check the fuel level on the fuel indicator
B. If the fuel level is too low,serew off the fuel tank cap fill it with Fuel to the shoulder of the filter. Waring: Do not overfill to avoid fuel overflowing.
C. Remount the cap
3. Air filter A. Remove the filter cover. B. Check the filter elemebt to make sure it is clean and intact.
- 5 -
C...It is dirty ,take out the element for cleaning
·
··
·Wash it in solvent
·
··
·Squeeze dry
·
··
·Drop some drips of machine oil into it.
·
··
·Squeeze it dry again.
D. Remount the filter element and put it on filter cover.
4.Battery
Check to make sure that the electrolyte levelin every call is Between the upper and lower limit lines.
1) Upper limit line
2) Lower limit line
- 6 -
4..Starting of generator
Starting with kick starter
1. Remove all loads from the AC output terminal.
2. Turn off the AC circuit breaker.
3. Open the fuel valve
4. Turn the choke handle to “CLOSE” positioon
Caution: DO not close the choke when starting a hot engine.
5.Turn on the engine switch.
- 7 -
6...Gently hold the starting pull handle till some resistance is felt and then Pull it abruptly. Waring: Never let the starting pull handle retract suddenly but return it gently.
7. When the engine is warmed up,set the choke handle to “Open” position
Electric start
1. Remove all loads from the output terminal
2. Turn of the AC breaker.
3. Open the fuel valve.
- 8 -
4... Set the choke handle to “Close” position
Caution: Do not close the choke when starting a hot engine
5: Turn on the electronic start switch.
6. Release the electric start.
7: When the engine is warmed up,set the cloke handle to “Open” position
- 9 -
5. Usage of Generator
To keep the generator in optimal con- Dition mechanically and electrically the Following points shall be observed. Warning: The generator has to be Ground for fear that any mistake would Be made electrically.
The total power of electric load shall not exceed the rated power of the generator. Electric appliances: motor driven de­Vices esp.produce large current on starting. The following table is for reference to be ma­De when the devices. Lised below are connected to the generator.
Loading...