T30 V.2 Quick Start
digital charger, discharger and cycler
T30
V.2
Output Battery Connections
Connect the battery leads to the output connections of the charger
OUT 1 – OUTPUT1 can be used to charge NiCd, NiMH, Lithium Polymer,
Lead-Acid or LiFePo
4 batteries
Select Battery Type
Rotate the Dial and move the cursor to “Batt. Type” and push the Dial.
Then, select the type of battery (NiCd, NiMH, LiPo, Pb or LiFe).
Once selected, push the Dial to confirm.
Set Parameters for Charging/Discharging
Rotate the Dial and move the cursor to the following parameters. Push the Dial
to set the parameter and push the Dial for the second time to confirm the value.
Charging Setup Menu
Push and hold the Dial to display the charging method. Rotate the Dial to select:
Charge
D-charge
(denotes discharge)
Cycle
1.VC-CC (for LiPo, Pb and LiFePo4 )
1.Automatic
2.Nor mal
3.Linear
1.Char ge then Discharge
2.Dischar ge then Charge
Cycle Time: 1 – 10 cycles
Cool-off Delay time: 1 – 30 minutes
Start Charging, Discharging or Cycling
Push and Hold the Dial to start the selected operation.
View Data
You can view the charging or discharging data by pressing the
and buttons.
To stop the charging or discharging process, press and hold the
button for 5 seconds.
T30 V.2
Battery Setup Menu
Display Of Setup Menu
For The Different Battery Type
[0] BATTERY NAME..
BATT. TYPE : LiFe
BATT. VOLT:3S 9.9V
CAPACITY : 2100mAh
CHG CURR. : 2.1A
DCHG CURR. : 2.1A
DCHG VOLT. : 3.3V/C
CUT-TEMP:55ºC
MAX-CAP.:120%
T30V.2 INSTRUCTION MANUAL
8-line, 21 character large
graphic LCD with backlight
Heat sink cooling system
Intelligent cooling fan control system
Dial and Select (Push button)
1. Next menu
1. Previous menu
2. Stop operation
3. ESC (return to main menu)
Select Output
Data port for
Tahmazo T6B
For temperature sensor
Aluminium rugged case
Safety Fuse
Battery Output 1
Battery Output 2
4-8 cells Nicd/NiMH
Parameters of the Different Battery Type
Parameter Li-Polymer LiFe
Battery cells or voltage 3.7V(1S) ~ 44.4V(12S) 3.3V(1S) ~ 39.6V(12S)
Capacity 100 ~ 20000mAh 100 ~ 20000mAh
Charge current 0.1 ~ 10.0A 0.1 ~ 10.0A
Discharge voltage 0.1 ~ 5.0A 0.1 ~ 5.0A
Peak sensitivity Not Applicable Not Applicable
Trickle charge current CV-CC charge trickle CV-CC charge trickle
Temperature cut-off 10 – 65ºC 1ºC/step 10 – 65ºC 1ºC/step
50 – 150ºF 2ºF/step 50 – 150ºF 2ºF/step
Max-charge capacity 10% ~ 120% 10% step 10% ~ 120% 10% step
Pre-peak delay Not applicable Not applicable
Battery volt
(For LiPo, Pb and LiFePo4 )
Capacity
CHG CURR.
(Charging Current)
DCHG CURR.
(Discharging Current)
DCHG VOLT
Set the voltage of the battery pack
Set the capacity of the battery pack in mAh
Set the charging current in amp (A)
Set the discharging current in amp (A)
Set the cutoff voltage of each cell when
discharging the battery pack! REFER TO
THE SPECIFICATION OF THE BATTERY PACK
(from the battery manufacturer or agent).
DO NOT DISCHARGE THE BATTERY BELOW
THE ALLOWABLE VOLTAGE AS SPECIFIED
BY THE MANUFACTURER.
11-15v DC Input
plug/clips (provided)