All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and
keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such
information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any
intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that:
§ the copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all copies.
§ this document shall not be posted on any network computer or broadcast in any media and no modification of any
part of this document shall be made.
Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities.
The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise
expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein.
The document could include technical inaccuracies or typographical errors. Changes are periodically added to the
information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications
data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software that
include TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION
CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER
IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY
DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE,
DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and
shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security
standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the
state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be
held liable for any third party actions, and in particular in case of any successful attack against systems or equipment
incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result
from any use of its products. It is further stressed that independent testing and verification by the person using the
product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning
could result in damage to persons or property, denial of service, or loss of privacy.
TAGSYS products referenced in these pages are either trademarks or registered trademarks of TAGSYS S.A. Other
products and company names mentioned in these pages may be the trademarks of their respective owners.
Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft
Corporation in the U.S.A. and/or other countries.
Printed in France.
TAGSYS – 180 Chemin de St Lambert, 13821 LA PENNE SUR HUVEAUNE, France.
Tel: +33 (0)4.91.27.57.00 / Fax: +33 (0)4.91.27.57.01
Document Reference: 10738A1
Read This First
Read This First
Welcome to the TAGSYS RFID System. This User's Guide is designed to help you get up and
running quickly using this high-quality Radio Frequency Identification (RFID) system. It describes
all you need to know about how to install and use the TAGSYS system and its associated
applications.
It provides a step-by-step guide for the following procedures:
§ Installation of the Textile Rental Stack Antenna
§ Configuring the product for use within your laundry system
This guide is designed for all TAGSYS partners and for TAGSYS Expert Network customers
implementing a low-cost and high-performance RFID solution.
This document does not assume any previous knowledge of Radio Frequency Identification (RFID)
technology.
Conventions
Symbol Meaning
CAUTION: A note that advises users that a specific action could result in the loss of data or
damage the hardware.
WARNING: A note that advises users that a specific action may result in physical harm.
A note that provides additional information that helps the user perform a task or obtain the
best performance from the product.
Abbreviations and Acronyms
AFI Application Family Identifier
AON All Or None
API Application Programming Interface
ASK Amplitude Shift Keying
CPU Central Processing Unit
CRC Cyclic Redundancy Check
DLL Dynamic-Link Library
DPU Digital Processing Unit
DSFID Data Storage Format Identifier
DSP Digital Signal Processor
EAS Electronic Article Surveillance
ETX End of Text
HPI Host Port Interface
L-SA2 8-Book Library Stack Antenna User's Guide
I/O Input/Output
IFD Interface Device
ILS Integrated Library System
LED Light Emitting Diode
LSB Least Significant Bit
MSB Most Significant Bit
OS Operating System
PC Personal Computer
PCB Printed Circuit Board
RAM Random Access Memory
RF Radio Frequency
RFID Radio Frequency IDentification
RFU Reserved for Future Use
RPU Radio Processing Unit
RTC Real Time Clock
SAM Security Access Module
STX Start of Text
TTF Tag Talks First
TTL Transistor-Transistor Logic
TTY TeleTYpe
UID Unique Identifier
Glossary
Anti-Collision Tag capability making it readable while other tags are present in the RF field.
Antenna An aerial that receives and/or transmits radio frequency signals. Aerials are
manufactured in a variety of forms, shapes and sizes.
Baud A unit of measure of data transmission speed representing the number of signal changes per
second.
BNC Connector Cylindrical metal connector with a copper core that is located at the tip of a
coaxial cable, and is used to connect cables together. It attaches by pushing and twisting the outer
cylinder on to two locking pins.
Coupler See Reader.
Data Storage Format Identifier Identifies the structure of the data stored in the smart label.
Digital Signal Processor This part of the Radio Processing Unit (RPU) performs real-time smart
label decoding and manages the Medio L200 configuration.
Dynamic-Link Library Executable routines that are stored as separate files with DLL extensions
and executed only when needed by the program.
Host Port Interface Interface used to access the DSP memory.
Read This First
IEC Connector Three-pin connector used on sockets that carry mains electricity to the computer.
All PCs use a male IEC connector and mains lead with a female IEC connector.
Interrogation Pulse A signal transmitted by the coupler to activate the smart label’s transponder.
Monitoring Port Parallel Port granting access to the HPI. It communicates directly with the Radio
Processing Unit
Multi-Read See Anti-Collision
Nibble Half a byte (4 bits)
Packaged Reader A reader in its casing.
Phase Shift Difference of phase between the 13.56 MHz field emitted by two antennas. This
feature is dedicated to rotating field applications and three-dimensional volume smart label
detection.
Protocol A set of rules governing a particular function, such as the flow of data/information in a
communication system (communication between a smart label and a reader or a reader and a PC
or host computer).
Radio Frequency Identification System (RFID) An automatic identification and data capture
system comprising one or more readers and one or more smart labels in which data transfer is
achieved by means of suitable modulated inductive or radiating electromagnetic carriers.
Radio Processing Unit This unit controls the main features of the Medio L200, such as the RF
channels, the multiplexer and the smart label decoding.
Reader Electronic system for the communication between smart labels and host computers.
Reader Talks First Chip protocol for exchanges between the reader and the chip, whereby the
chip waits for a command from the reader to which it responds.
RS-232 Electronic Industries Association (EIA) standard for serial interfaces between computers
and peripherals which defines the function, the electrical characteristics and the timing of signals.
RS-485 Electronic Industries Association (EIA) standard for multipoint, differential data
transmission. It allows multiple nodes to communicate bi-directionally over 1 or 2 twisted pairs.
Smart Label Small, flexible tag from the 13.56 MHz TAGSYS product line. A smart label is made
of a chip connected to an etched antenna.
Tag See Smart Label.
Tag Talks First Chip protocol for exchanges between the reader and the chip, whereby the tag
sends information continuously, without waiting for a specific command from the reader.
Transceiver A combined transmitter and receiver.
Transponder A combined receiver/transmitter that automatically transmits a signal when a ‘trigger’
is received by it. The trigger is often a pulse, called an interrogation pulse.
L-SA2 8-Book Library Stack Antenna User's Guide
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at:
Please remember to quote the Document Reference Number 10738A1, your job title and your
company.
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However,
should you find a defect with this product, please notify your TAGSYS Quality Service
representative using the dedicated Product Return Form.