Tagsys MEDIOL400CHAN4 User Manual

Medio L400
User's Guide
Revision 1.6
March 2008
Medio L400
Disclaimer and Limitation of Liability
All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that:
The copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all
copies.
This document shall not be posted on any network computer or broadcast in any media and no modification of any
part of this document shall be made.
Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities.
The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein. The document could include technical inaccuracies or typographical errors. Changes are periodically added to the information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software which includes TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE, DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be held liable for any third party actions, and in particular in case of any successful attack against systems or equipment incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result from any use of its products. It is further stressed that independent testing and verification by the person using the product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning could result in damage to persons or property, denial of service, or loss of privacy.
© 2000-2008 TAGSYS. All rights reserved.
Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the U.S.A. and/or other countries.
I-Code is a registered trademark of Philips.
Tag-It is a registered trademark of Texas Instruments.
TAGSYS and E-connectware are registered trademarks of TAGSYS
Printed in France.
TAGSYS – 180 Chemin de St Lambert, 13821 LA PENNE SUR HUVEAUNE, France.
Tel: +33 (0)4.91.27.57.00 / Fax: +33 (0)4.91.27.57.01
Document Reference: DOC12451A6
2/51 Revision 1.6 March 2008
Read This First
Read This First
Welcome to the TAGSYS range of products operating at the 13.56 MHz frequency. This range of products is used to implement high-quality RFID systems for demanding applications.
This document provides information about how to install and use the Medio L400 reader.
Audience
This document requires familiarity with RFID technology. It is intended for people in charge of installing and using the product.
Conventions
Symbol Meaning
CAUTION: A note that advises users that a specific action could result in the loss of data or
damage the hardware.
WARNING: A note that advises users that a specific action may result in physical harm.
A note that provides additional information that helps the user performs a task or obtains the best performance from the product.
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at:
Telephone: +33 (0)4 91 27 57 00
Fax: +33 (0)4 91 27 57 01
E-Mail: info@tagsysrfid.com
Website: http://www.tagsysrfid.com
Contact for Comments
We welcome your feedback to help us provide high quality documentation.
For technical comments, please contact our welcome desk:
Telephone: +33 (0)4 91 27 57 00
Fax: +33 (0)4 91 27 57 01
E-Mail: info@tagsysrfid.com
Please remember to quote the Document Reference Number DOC12451A6, your job title and your company.
March 2008 Revision 1.6 3/51
Medio L400
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However, should you find a defect with this product, please notify your TAGSYS Quality Service representative using the dedicated Product Return Form.
Telephone: +33 (0)4 91 27 57 36
Fax: +33 (0)4 91 27 57 02
4/51 Revision 1.6 March 2008
Read This First
Table of Contents
PUBLISHING INFORMATION __________________________________________________________ 2
DISCLAIMER AND LIMITATION OF LIABILITY___________________________________________________ 2
READ THIS FIRST ____________________________________________________________________ 3
AUDIENCE_____________________________________________________________________________ 3 CONVENTIONS _________________________________________________________________________ 3 IF YOU NEED ASSISTANCE ________________________________________________________________ 3 CONTACT FOR COMMENTS _______________________________________________________________ 3 QUALITY ISSUES _______________________________________________________________________ 4
1 FOR YOUR SAFETY _______________________________________________________________ 7
1.1 GENERAL USE ____________________________________________________________________ 7
1.2 CARE AND MAINTENANCE ___________________________________________________________ 7
1.3 IMPORTANT SAFETY INFORMATION ____________________________________________________ 8
1.3.1 OPERATING ENVIRONMENT ________________________________________________________ 8
2 CERTIFICATION___________________________________________________________________ 9
2.1 OCCUPATIONAL HEALTH AND SAFETY NOTICES _________________________________________ 9
2.2 REGULATORY NOTICES _____________________________________________________________ 9
2.2.1 IN EUROPE (CE AND RTTE DIRECTIVES) _____________________________________________ 9
2.2.2 FCC ID CROSS REFERENCE TABLE ________________________________________________ 10
2.2.3 IN USA (FCC DIRECTIVE) ________________________________________________________ 13
2.2.4 IN CANADA_____________________________________________________________________ 14
2.3 ROHS AND WEEE DIRECTIVES _____________________________________________________ 14
2.3.1 ROHS (RESTRICTION OF THE USES OF CERTAIN HAZARDOUS SUBSTANCES)_______________ 14
2.3.2 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT)____________________________ 14
3 OVERVIEW ______________________________________________________________________ 15
3.1 KEY FEATURES ___________________________________________________________________ 16
3.2 DELIVERY _______________________________________________________________________ 16
3.3 PHYSICAL DESCRIPTION ___________________________________________________________ 17
3.3.1 FRONT PANEL __________________________________________________________________ 17
3.3.2 REAR PANEL ___________________________________________________________________ 21
4 INSTALLATION __________________________________________________________________ 22
4.1 MECHANICAL ASPECTS ____________________________________________________________ 22
4.2 CABLING REQUIREMENTS __________________________________________________________ 22
4.3 USING USB INTERFACE ____________________________________________________________ 23
4.3.1 INSTALLING USB DRIVERS________________________________________________________ 23
4.3.2 USING THE USB INTERFACE ______________________________________________________ 23
4.4 USING RS-232 INTERFACE _________________________________________________________ 23
4.5 USING 10/100 ETHERNET INTERFACE ________________________________________________ 23
March 2008 Revision 1.6 5/51
Medio L400
4.6 RESTORING FACTORY CONFIGURATION _______________________________________________ 24
4.7 RUNNING TAGSYS EXPLORER FOR THE FIRST TIME _____________________________________ 24
4.7.1 INSTALLING TAGSYS EXPLORER ___________________________________________________ 24
4.7.2 CONNECTING TO A DEVICE USING TAGSYS EXPLORER WIZARD __________________________ 26
4.7.3 READING THE UID OF ISO 15693 TAGS _____________________________________________ 32
4.7.4 READING AND WRITING ISO 15693 TAG MEMORY _____________________________________ 33
4.7.5 UPGRADING SYSTEM OR RADIO FIRMWARE __________________________________________ 34
5 ADVANCED NOTIONS ____________________________________________________________ 37
5.1 READER ARCHITECTURE ___________________________________________________________ 37
5.2 READER TO HOST PROTOCOLS______________________________________________________ 38
5.2.1 TAGSYS STXNG _______________________________________________________________ 38
5.2.2 HEARTBEAT____________________________________________________________________ 38
5.2.3 TELNET________________________________________________________________________ 39
5.2.4 SERIAL CONSOLE _______________________________________________________________ 39
5.2.5 STANDALONE MODE _____________________________________________________________ 40
5.3 READER OPERATION PRINCIPLES ____________________________________________________ 40
5.3.1 NOTION OF READ MODES _________________________________________________________ 40
5.3.2 NOTION OF EVENTS______________________________________________________________ 41
6 TECHNICAL SPECIFICATIONS ____________________________________________________ 43
6.1 TECHNICAL DATA _________________________________________________________________ 43
6.2 MECHANICAL DATA________________________________________________________________ 44
6.3 RS232 CONNECTOR ______________________________________________________________ 45
6.4 GPIO CONNECTOR _______________________________________________________________ 46
6.4.1 PIN ASSIGNMENT________________________________________________________________ 46
6.4.2 ELECTRICAL CHARACTERISTICS ___________________________________________________ 46
6.4.3 USING INPUTS __________________________________________________________________ 46
6.4.4 USING OUTPUTS ________________________________________________________________ 48
7 WARRANTY CONDITIONS ________________________________________________________ 49
7.1 WARRANTY ______________________________________________________________________ 49
7.2 WARRANTY EXCLUSIONS ___________________________________________________________ 49
7.2.1 GENERAL PROVISIONS ___________________________________________________________ 50
7.2.2 HOW TO RETURN DEFECTIVE PRODUCTS ____________________________________________ 50
6/51 Revision 1.6 March 2008
For Your Safety
1 For Y our Safety
1.1 General Use
The Medio L400 reader is designed to be reliable and to provide continuous, trouble-free service. Please observe the following general tips:
Take care not to scratch the device. Keep the device clean. When working with the device,
use only TAGSYS-approved accessories.
This device is not waterproof and should not be exposed to rain or moisture. Under extreme
conditions, water may enter the circuitry.
Protect the device from extreme temperatures. For example, do not place the device in a
windowed area where the sun may cause extreme temperatures, and keep it away from heaters and other heat sources.
Do not store or use the device in any location that is extremely dusty, damp, or wet.
Use a soft, damp cloth to clean the device. If the surface of the device becomes soiled,
clean it with a soft cloth moistened with a diluted window-cleaning solution.
1.2 Care and Maintenance
This device should be handled with care. The suggestions below will increase the lifetime of this device.
Keep the device and all parts and accessories out of the reach of small children.
Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode
electronic circuits.
Do not use or store the device in dusty, dirty areas. Its moving parts can be damaged.
Do not store in hot areas. High temperatures can shorten the life of electronic devices,
damage batteries and warp or melt certain plastics.
Do not store in cold areas. When the device warms up (to its normal temperature), moisture can form inside the device, which may damage electronic circuit boards.
Do not attempt to open the device. Non-professional handling of the device may damage it and will void the TAGSYS warranty.
Handle the device with care. Shock and vibration may break internal circuit boards.
Do not clean the device with harsh chemicals, cleaning solvents or strong detergents.
Gently wipe the device with a soft cloth slightly dampened in a mild soap-and-water solution.
Do not paint the device. Paint may clog the device’s moving parts and prevent proper operation. Paint with metallic contents may limit device performances.
If the device or any accessory are not working properly, take it to your nearest qualified TAGSYS representative.
March 2008 Revision 1.6 7/51
Medio L400
1.3 Important Safety Information
1.3.1 Operating Environment
When connecting the device or any accessory to another device, read its user’s guide for detailed safety instructions. Do not connect incompatible products.
As with all RF equipment, users are advised that the equipment should only be used in its normal operating mode described in this document.
8/51 Revision 1.6 March 2008
Certification
2 Certification
2.1 Occupational Health and Safety Notices
TAGSYS Products have been designed not to exceed the limits given in the European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in conjunction with the European Standard EN 50357 describing how to evaluate the exposure level.
It is the responsibility of the TAGSYS Partner to install the Medio L400 as described in TAGSYS Documentation and with the appropriate antennas.
Modification of any TAGSYS System is prohibited without the written consent of TAGSYS. Unauthorized modifications may void the conformity of the equipment to safety standards and will void the TAGSYS warranty.
An RF fields survey has been carried out on all the TAGSYS System components, in accordance with AS/NZS 2771.1: Radio Frequency Radiation, Part 1. According to this standard the maximum allowable RF exposure levels (non-occupational) at 3 kHz to 300 GHz are 200 µW/cm2.
2.2 Regulatory Notices
An RFID system typically composed of an RF emission device such as the Medio L400 is subject to national regulations that may differ by country.
One important item to consider is the maximum permissible magnetic field intensity at a distance of 10 meters from the antenna that must not exceed 42 dBµA/m in Europe and 38 dBµA/m in US.
The Medio L400 meets these limits.
It is the responsibility of the TAGSYS Partner to install the Medio L400 as described in this User’s Guide or in TAGSYS Documentation.
2.2.1 In Europe (CE and RTTE Directives)
The Medio L400 complies (CE Declaration of Conformity granted) with the European EMC directive.
The Medio L400 complies with the requirements of the Telecommunication Terminal Equipment Act (FTEG) and the RTTE Directive 1995/5/EC.
It is the responsibility of the TAGSYS Reseller to install the Medio L400 as described in this Reference guide or TAGSYS Documentation.
Any modification of the Medio L400 is prohibited without the written consent of TAGSYS. Unauthorized modifications may void the conformity of the equipment to CE and RTTE Directives and will void the TAGSYS warranty.
If a Medio L400 is further integrated in a different product, it is the responsibility of the manufacturer of this complementary product to obtain the required approvals for this product.
March 2008 Revision 1.6 9/51
Medio L400
2.2.2 FCC ID Cross Reference Table
It is the responsibility of the TAGSYS Partner to install the Medio L400 as described in the table below, taking care of only installing the right antenna configuration with the right power settings.
Table 1: Medio L400-2 FCC ID Cross reference Table
Antenna Configuration
Aero LB Antenna
Aero LC Antenna
TR-HA1 Antenna
TR-SA1 Antenna
Outside Dimension
Channel Setting Multiplexing
250X250 Single Channel No
400X500 Single Channel No
200X100 Single Channel No
400X500 Single Channel No
L-SA3 Antenna 250X330 Single Channel No
L-SA4 Antenna 220X220 Single Channel No
Aero LI Antenna
250X250 Single Channel No
Max. Output Power
4W
2W
2W
2W
1.5W
1W
1W
FCC ID
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
Antenna Configuration
TR-CAU Antenna
Aero LB Antenna
To comply with band edge regulation, when used in vertical upright position the Aero LB and Aero LC antennas can read tags in the following RFID uplink protocols configurations
Table 2: Medio L400-4 FCC ID Cross reference Table
Outside Dimension
Channel Setting Multiplexing
170X900 Quad-Channel Yes
250X250 Quad-Channel Yes
Max. Output Power
2W
2W
FCC ID
QHKMEDIOL400CHAN4
QHKMEDIOL400CHAN4
To comply with band edge regulation, when used in vertical upright position the Aero LB antenna can read tags in the following RFID uplink protocols configurations
10/51 Revision 1.6 March 2008
Certification
To comply with band edge regulation, when reading ISO15693 tags TR-CAU antenna can read tags in the following RFID uplink protocols configurations
In I-Code 1 (C270) parameters window set the uplink parameters as follow:
Bit Coding: “Standard” (1 out of 256 pulse)
March 2008 Revision 1.6 11/51
Medio L400
In ISO15693 Parameters window set the uplink parameters as follow:
Command modulation depth: 10% (ASK)
EOF modulation depth: 10% (ASK)
Data coding mode: 1 of 256
12/51 Revision 1.6 March 2008
Certification
2.2.3 In USA (FCC Directive)
The Medio L400 has been designed to comply with Part 15 of the FCC Rules. Furthermore typical configurations listed section 2.2.2 have been successfully tested with Part 15 of the FCC rules (FCC ID Numbers are listed on all system-mounted TAGSYS Antennas).
Medio L400-2 and Medio L400-4
WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNCIATIONS COMMISSION (FCC) RADIO
INTERFERENCE STATEMENT 47 CFR Section 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different to that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
NO UNAUTHORIZED MODIFICATIONS
47 CFR Section 15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without signed
written permission from TAGSYS SA. Unauthorized modification may void the equipment authorization from the FCC and will void the TAGSYS warranty.
ANTENNA REQUIREMENT
47 CFR Section 15.203
CAUTION: This equipment must be professionally installed. The installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Non­professional installation or installation of the equipment with an improper antenna may void the equipment authorization from the FCC and will void the TAGSYS warranty.
Operation is subject to the following two conditions: (1) The system devices may not cause harmful interference, and (2) The system devices must accept any interference received, including interference that may cause undesired operation.
March 2008 Revision 1.6 13/51
Medio L400
2.2.4 In Canada
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p) is no more than that permitted for successful communication.
The Medio L400-2 device has been designed to operate with the antennas listed below, and having a maximum gain of -25 dBi. Antenna not included in this list or having a gain greater than ­25 dBi are striclly prohibited for use with this device. The require antenna impedance is 50 ohms.
Aero LB and Aero LC antennas meet this requirement with a gain less than -25dBi.
2.3 RoHS and WEEE Directives
2.3.1 RoHS (Restriction of the uses of certain Hazardous Substances)
TAGSYS certifies that this product is compliant with the European Directive 2002/95/EC for the restriction in Electric and Electronic Equipments (RoHS) of the use of the following hazardous substances:
Lead
Mercury
Cadmium
Hexavalent Chromium
Polybrominated biphenyl flame retardants
Polybrominated diphenyl ether flame retardants
This declaration is based on information provided by our suppliers and subcontractors.
2.3.2 WEEE (Waste Electrical and Electronic Equipment)
This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE) This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment. For further information, please contact your local or regional authorities.
14/51 Revision 1.6 March 2008
Overview
3 Overview
The Medio L400 is a long-range 13.56MHz RFID reader intended for RFID applications requiring a high performance, long range RFID infrastructure.
The L400 uses advances in Digital Signal Processing (DSP) and RF Front End technology to achieve breakthrough performance in read range and read speed with industry leading signal to noise ratio. The L400 has been specifically designed to operate in noisy environments such as manufacturing plants and distribution facilities while maintaining the highest levels of data integrity for item level track and trace, inventory management and security. Designed as a network device, the L400 conserves critical network bandwidth by filtering tag data to remove redundancies before transmitting to enterprise systems.
With breakthrough sensor technology and self diagnostic capability, the L400 is the industry’s first self-correcting intelligent RFID reader. The L400 can be remotely managed and administered to ensure you get the highest levels of performance from your RFID infrastructure. The L400 and e­connectware, TAGSYS’ comprehensive set of management and administrative tools, create an intelligent platform to allow you to manage your RFID infrastructure just as you do a voice or data
network to enable scalable, secure and persistent RFID Quality of Service.
March 2008 Revision 1.6 15/51
Medio L400
3.1 Key Features
Table 3: Medio L400 Key Features
Description
Operating Frequency 13.56 MHz
Chip Compatibility ISO15693
Number of channels 2 (Medio L400-2)
RF Output Power 500mW to 5W (+/- 10%)
Communication Interfaces RS232 (up to 115200 bauds)
Communication Protocols TAGSYS StxNG
Medio L400
ISO18000-3 Mode 1 C370(I-Code SLI) C270 (I-Code 1) I-Code ePC I-Code UID Upgradable to the anticipated EPCglobal HF Gen2 Standard
4 (Medio L400-4)
USB 1.1 10/100 Ethernet
Telnet & Serial Console Standalone Mode Heartbeat
I/O Ports (GPIO) 4 Inputs
4 Outputs
User Interface LCD Screen With Backlight (2x16 Characters)
Keypad (Up, Down, Select)
Remote Monitoring Many health indicators are remotely accessible, such as :
. System uptime . Read/Write count (per channel) . RF power amplifiers consumption . RF power amplifiers operating temperature . Antennas tuning status, . Real-time Raw signal capture, …
Firmware Remotely upgradeable
3.2 Delivery
The Medio L400 reader kit contains the following items:
16/51 Revision 1.6 March 2008