All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and
keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such
information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any
intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that:
The copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all
copies.
This document shall not be posted on any network computer or broadcast in any media and no modification of any
part of this document shall be made.
Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities.
The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise
expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein.
The document could include technical inaccuracies or typographical errors. Changes are periodically added to the
information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications
data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software which
includes TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION
CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER
IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY
DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE,
DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and
shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security
standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the
state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be
held liable for any third party actions, and in particular in case of any successful attack against systems or equipment
incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result
from any use of its products. It is further stressed that independent testing and verification by the person using the
product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning
could result in damage to persons or property, denial of service, or loss of privacy.
Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft
Corporation in the U.S.A. and/or other countries.
I-Code is a registered trademark of Philips.
Tag-It is a registered trademark of Texas Instruments.
TAGSYS and E-connectware are registered trademarks of TAGSYS
Printed in France.
TAGSYS – 180 Chemin de St Lambert, 13821 LA PENNE SUR HUVEAUNE, France.
Welcome to the TAGSYS range of products operating at the 13.56 MHz frequency. This range of
products is used to implement high-quality RFID systems for demanding applications.
This document provides information about how to install and use the Medio L400 reader.
Audience
This document requires familiarity with RFID technology. It is intended for people in charge of
installing and using the product.
Conventions
Symbol Meaning
CAUTION: A note that advises users that a specific action could result in the loss of data or
damage the hardware.
WARNING: A note that advises users that a specific action may result in physical harm.
A note that provides additional information that helps the user performs a task or obtains the
best performance from the product.
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at:
Telephone: +33 (0)4 91 27 57 00
Fax: +33 (0)4 91 27 57 01
E-Mail: info@tagsysrfid.com
Website: http://www.tagsysrfid.com
Contact for Comments
We welcome your feedback to help us provide high quality documentation.
For technical comments, please contact our welcome desk:
Telephone: +33 (0)4 91 27 57 00
Fax: +33 (0)4 91 27 57 01
E-Mail: info@tagsysrfid.com
Please remember to quote the Document Reference Number DOC12451A3, your job title and your
company.
February 2008 Revision 1.3 3/50
Medio L400
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However,
should you find a defect with this product, please notify your TAGSYS Quality Service
representative using the dedicated Product Return Form.
Telephone: +33 (0)4 91 27 57 36
Fax: +33 (0)4 91 27 57 02
4/50 Revision 1.3 February 2008
Read This First
Table of Contents
PUBLISHING INFORMATION __________________________________________________________ 2
DISCLAIMER AND LIMITATION OF LIABILITY___________________________________________________ 2
READ THIS FIRST ____________________________________________________________________ 3
AUDIENCE_____________________________________________________________________________ 3
CONVENTIONS _________________________________________________________________________ 3
IF YOU NEED ASSISTANCE ________________________________________________________________ 3
CONTACT FOR COMMENTS _______________________________________________________________ 3
QUALITY ISSUES _______________________________________________________________________ 4
1 FOR YOUR SAFETY _______________________________________________________________ 7
1.1 GENERAL USE ____________________________________________________________________ 7
1.2 CARE AND MAINTENANCE ___________________________________________________________ 7
1.3 IMPORTANT SAFETY INFORMATION ____________________________________________________ 8
7.2.1 GENERAL PROVISIONS ___________________________________________________________ 49
7.2.2 HOW TO RETURN DEFECTIVE PRODUCTS ____________________________________________ 49
6/50 Revision 1.3 February 2008
For Your Safety
1 For Y our Safety
1.1 General Use
The Medio L400 reader is designed to be reliable and to provide continuous, trouble-free service.
Please observe the following general tips:
Take care not to scratch the device. Keep the device clean. When working with the device,
use only TAGSYS-approved accessories.
This device is not waterproof and should not be exposed to rain or moisture. Under extreme
conditions, water may enter the circuitry.
Protect the device from extreme temperatures. For example, do not place the device in a
windowed area where the sun may cause extreme temperatures, and keep it away from
heaters and other heat sources.
Do not store or use the device in any location that is extremely dusty, damp, or wet.
Use a soft, damp cloth to clean the device. If the surface of the device becomes soiled,
clean it with a soft cloth moistened with a diluted window-cleaning solution.
1.2 Care and Maintenance
This device should be handled with care. The suggestions below will increase the lifetime of this
device.
• Keep the device and all parts and accessories out of the reach of small children.
• Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode
electronic circuits.
• Do not use or store the device in dusty, dirty areas. Its moving parts can be damaged.
• Do not store in hot areas. High temperatures can shorten the life of electronic devices,
damage batteries and warp or melt certain plastics.
• Do not store in cold areas. When the device warms up (to its normal temperature), moisture
can form inside the device, which may damage electronic circuit boards.
• Do not attempt to open the device. Non-professional handling of the device may damage it
and will void the TAGSYS warranty.
• Handle the device with care. Shock and vibration may break internal circuit boards.
• Do not clean the device with harsh chemicals, cleaning solvents or strong detergents.
Gently wipe the device with a soft cloth slightly dampened in a mild soap-and-water
solution.
• Do not paint the device. Paint may clog the device’s moving parts and prevent proper
operation. Paint with metallic contents may limit device performances.
• If the device or any accessory are not working properly, take it to your nearest qualified
TAGSYS representative.
February 2008 Revision 1.3 7/50
Medio L400
1.3 Important Safety Information
1.3.1 Operating Environment
When connecting the device or any accessory to another device, read its user’s guide for detailed
safety instructions. Do not connect incompatible products.
As with all RF equipment, users are advised that the equipment should only be used in its normal
operating mode described in this document.
8/50 Revision 1.3 February 2008
Certification
2 Certification
2.1 Occupational Health and Safety Notices
TAGSYS Products have been designed not to exceed the limits given in the European Standard
EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic
Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in
conjunction with the European Standard EN 50357 describing how to evaluate the exposure level.
It is the responsibility of the TAGSYS Partner to install the Medio L400 as described in TAGSYS
Documentation and with the appropriate antennas.
Modification of any TAGSYS System is prohibited without the written consent of TAGSYS.
Unauthorized modifications may void the conformity of the equipment to safety standards and will
void the TAGSYS warranty.
An RF fields survey has been carried out on all the TAGSYS System components, in accordance
with AS/NZS 2771.1: Radio Frequency Radiation, Part 1. According to this standard the maximum
allowable RF exposure levels (non-occupational) at 3 kHz to 300 GHz are 200 µW/cm2.
2.2 Regulatory Notices
An RFID system typically composed of an RF emission device such as the Medio L400 is subject
to national regulations that may differ by country.
One important item to consider is the maximum permissible magnetic field intensity at a distance of
10 meters from the antenna that must not exceed 42 dBµA/m in Europe and 38 dBµA/m in US.
The Medio L400 meets these limits.
It is the responsibility of the TAGSYS Partner to install the Medio L400 as described in this
User’s Guide or in TAGSYS Documentation.
2.2.1 In Europe (CE and RTTE Directives)
The Medio L400 complies (CE Declaration of Conformity granted) with the European EMC
directive.
The Medio L400 complies with the requirements of the Telecommunication Terminal Equipment
Act (FTEG) and the RTTE Directive 1995/5/EC.
It is the responsibility of the TAGSYS Reseller to install the Medio L400 as described in this
Reference guide or TAGSYS Documentation.
Any modification of the Medio L400 is prohibited without the written consent of TAGSYS.
Unauthorized modifications may void the conformity of the equipment to CE and RTTE Directives
and will void the TAGSYS warranty.
If a Medio L400 is further integrated in a different product, it is the responsibility of the
manufacturer of this complementary product to obtain the required approvals for this product.
February 2008 Revision 1.3 9/50
Medio L400
2.2.2 FCC ID Cross Reference Table
It is the responsibility of the TAGSYS Partner to install the Medio L400 as described in the table
below, taking care of only installing the right antenna configuration with the right power settings.
Antenna
Configuration
Outside
Dimension
Channel Setting Multiplexing
Max. Output
Power
FCC ID
Aero LB
Antenna
Aero LC
Antenna
250X250 Single Channel No
400X500 Single Channel No
To comply with band edge regulation, when used in vertical upright position the Aero LB and
Aero LC antennas can read tags in the following RFID uplink protocols configurations
4W
2W
QHKMEDIOL400CHAN2
QHKMEDIOL400CHAN2
In I-Code 1 (C270) parameters window set the uplink parameters as follow:
Bit Coding: “Standard” (1 out of 256 pulse)
10/50 Revision 1.3 February 2008
Certification
In ISO15693 Parameters window set the uplink parameters as follow:
Command modulation depth: 10% (ASK)
EOF modulation depth: 10% (ASK)
Data coding mode: 1 of 256
February 2008 Revision 1.3 11/50
Medio L400
2.2.3 In USA (FCC Directive)
The Medio L400 has been designed to comply with Part 15 of the FCC Rules. Furthermore typical
configurations based on the use of Single Antenna like Aero LB at 4W and Aero LC at 2 Watts,
have been successfully tested with Part 15 of the FCC rules (FCC ID Numbers are listed on all
system-mounted TAGSYS Antennas).
Medio L400-2
WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNCIATIONS COMMISSION (FCC) RADIO
INTERFERENCE STATEMENT 47 CFR Section 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and if not installed and used in accordance with the instructions
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
▪ Reorient or relocate the receiving antenna.
▪ Increase the separation between the equipment and receiver.
▪ Connect the equipment into an outlet on a circuit different to that to which the receiver is
connected.
▪Consult the dealer or an experienced radio/TV technician for help.
NO UNAUTHORIZED MODIFICATIONS
47 CFR Section 15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without signed
written permission from TAGSYS SA. Unauthorized modification may void the equipment
authorization from the FCC and will void the TAGSYS warranty.
ANTENNA REQUIREMENT
47 CFR Section 15.203
CAUTION: This equipment must be professionally installed. The installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Nonprofessional installation or installation of the equipment with an improper antenna may void the
equipment authorization from the FCC and will void the TAGSYS warranty.
Operation is subject to the following two conditions: (1) The system devices may not cause harmful
interference, and (2) The system devices must accept any interference received, including
interference that may cause undesired operation.
12/50 Revision 1.3 February 2008
Certification
2.2.4 In Canada
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
2.3 RoHS and WEEE Directives
2.3.1 RoHS (Restriction of the uses of certain Hazardous Substances)
TAGSYS certifies that this product is compliant with the European Directive 2002/95/EC for the
restriction in Electric and Electronic Equipments (RoHS) of the use of the following hazardous
substances:
• Lead
• Mercury
• Cadmium
• Hexavalent Chromium
• Polybrominated biphenyl flame retardants
• Polybrominated diphenyl ether flame retardants
This declaration is based on information provided by our suppliers and subcontractors.
2.3.2 WEEE (Waste Electrical and Electronic Equipment)
This product bears the selective sorting symbol for waste electrical and
electronic equipment (WEEE)
This means that this product must be handled pursuant to European
Directive 2002/96/EC in order to be recycled or dismantled to minimize
its impact on the environment.
For further information, please contact your local or regional authorities.
February 2008 Revision 1.3 13/50
Medio L400
3 Overview
The Medio L400 is a long-range 13.56MHz RFID reader intended for RFID applications requiring a
high performance, long range RFID infrastructure.
The L400 uses advances in Digital Signal Processing (DSP) and RF Front End technology to
achieve breakthrough performance in read range and read speed with industry leading signal to
noise ratio. The L400 has been specifically designed to operate in noisy environments such as
manufacturing plants and distribution facilities while maintaining the highest levels of data integrity
for item level track and trace, inventory management and security. Designed as a network device,
the L400 conserves critical network bandwidth by filtering tag data to remove redundancies before
transmitting to enterprise systems.
With breakthrough sensor technology and self diagnostic capability, the L400 is the industry’s first
self-correcting intelligent RFID reader. The L400 can be remotely managed and administered to
ensure you get the highest levels of performance from your RFID infrastructure. The L400 and econnectware, TAGSYS’ comprehensive set of management and administrative tools, create an
intelligent platform to allow you to manage your RFID infrastructure just as you do a voice or data
network to enable scalable, secure and persistent RFID Quality of Service.
14/50 Revision 1.3 February 2008
Overview
3.1 Key Features
Table 1: Medio L400 Key Features
Description
Operating Frequency 13.56 MHz
Chip Compatibility ISO15693
Number of channels 2 (Medio L400-2)
RF Output Power 500mW to 5W (+/- 10%)
Communication Interfaces RS232 (up to 115200 bauds)
Communication Protocols TAGSYS StxNG
Medio L400
ISO18000-3 Mode 1
C370(I-Code SLI)
C270 (I-Code 1)
I-Code ePC
I-Code UID
Upgradable to the anticipated EPCglobal HF Gen2 Standard
4 (Medio L400-4)
USB 1.1
10/100 Ethernet
Telnet & Serial Console
Standalone Mode
Heartbeat
I/O Ports (GPIO) 4 Inputs
4 Outputs
User Interface LCD Screen With Backlight (2x16 Characters)
Keypad (Up, Down, Select)
Remote Monitoring Many health indicators are remotely accessible, such as :
. System uptime
. Read/Write count (per channel)
. RF power amplifiers consumption
. RF power amplifiers operating temperature
. Antennas tuning status,
. Real-time Raw signal capture, …
Firmware Remotely upgradeable
3.2 Delivery
The Medio L400 reader kit contains the following items:
February 2008 Revision 1.3 15/50