Medio L40 - User's Guide
Publishing Information
Disclaimer and Limitation of Liability
All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that: The copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all
copies.
This document shall not be posted on any network computer or broadcast in any media and no modification of any
part of this document shall be made. Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities. The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise
expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein. The document could include technical inaccuracies or typographical errors. Changes are periodically added to the information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software which includes TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE, DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be held liable for any third party actions, and in particular in case of any successful attack against systems or equipment incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result from any use of its products. It is further stressed that independent testing and verification by the person using the product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning could result in damage to persons or property, denial of service, or loss of privacy.
© 2000-2011 TAGSYS. All rights reserved. Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft
Corporation in the U.S.A. and/or other countries. I-Code is a registered trademark of Philips. TAGSYS, MEDIO, E-connectware are registered trademarks of TAGSYS
Printed in France. TAGSYS – 785 Voie Antiope, Athélia III, 13600 La Ciotat, France. Tel: +33 (0) 4.42.18.89.00 / Fax: +33 (0) 4.42.18.89.01 Document Reference: DOC14467B3.
Medio L40 - User's Guide
Read This First
Welcome to the TAGSYS range of products operating at the 13.56 MHz frequency. This range of products is used to implement high-quality RFID systems for demanding applications.
This document provides information about how to install and use the Medio L40 reader.
Audience
This document requires familiarity with RFID technology. It is intended for people in charge of installing and using the product.
Conventions
Symbol Meaning
CAUTION: A note that advises users that a specific action could result in the loss of data or
damage the hardware. WARNING: A note that advises users that a specific action may result in physical harm.
A note that provides additional information that helps the user performs a task or obtains the best performance from the product.
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at:
Telephone: +33 (0) 4 42 18 89 00 Fax: +33 (0) 4 42 18 89 01 E-Mail: info@tagsysrfid.com Website: http://www.tagsysrfid.com
Contact for Comments
We welcome your feedback to help us provide high quality documentation. For technical comments, please contact our welcome desk:
Telephone: +33 (0) 4 42 18 89 00 Fax: +33 (0) 4 42 18 89 01 E-Mail: info@tagsysrfid.com
Please remember to quote the Document Reference Number DOC14467B3, your job title and your company.
July 2013 2.3 3/56
Medio L40 - User's Guide
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However, should you find a defect with this product, please notify your TAGSYS Quality Service representative using the dedicated Product Return Form.
Telephone: +33 (0) 4 42 18 89 00 Fax: +33 (0) 4 42 18 89 01
E-Mail: rma@tagsysrfid.com
4/56 Revision 2.3 July 2013
Medio L40 - User's Guide
Table of Contents
PUBLISHING INFORMATION __________________________________________________________ 2
D
ISCLAIMER AND LIMITATION OF LIABILITY
READ THIS FIRST ____________________________________________________________________ 3
A
UDIENCE
C
ONVENTIONS
I
F YOU NEED ASSISTANCE
C
ONTACT FOR COMMENTS
Q
UALITY ISSUES
_____________________________________________________________________________ 3
_________________________________________________________________________ 3
________________________________________________________________ 3
_______________________________________________________________ 3
_______________________________________________________________________ 4
1 FOR YOUR SAFETY _______________________________________________________________ 8
___________________________________________________ 2
1.1 G
1.2 C
1.3 I
1.3.1 O
ENERAL USE
ARE AND MAINTENANCE
MPORTANT SAFETY INFORMATION
PERATING ENVIRONMENT
_____________________________________________________________________ 8
___________________________________________________________ 8
________________________________________________________ 9
____________________________________________________ 9
2 CERTIFICATION __________________________________________________________________ 10
2.1 O
2.2 R
2.2.1 IN E
2.2.2 FCC ID C
2.2.3 IN USA (FCC D
2.2.4 IN C
2.3 ROHS
2.3.1 ROHS (R
2.3.2 WEEE (W
CCUPATIONAL HEALTH AND SAFETY NOTICES
EGULATORY NOTICES
UROPE
ANADA
AND
(CE
ROSS REFERENCE TABLE
_____________________________________________________________________ 15
WEEE D
ESTRICTION OF THE USES OF CERTAIN HAZARDOUS SUBSTANCES
ASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
____________________________________________________________ 10
AND
RTTE D
IRECTIVES
) ____________________________________________ 10
________________________________________________ 10
IRECTIVE
) _________________________________________________________ 14
IRECTIVES
______________________________________________________ 15
_________________________________________ 10
) _______________ 15
) ____________________________ 16
3 OVERVIEW_______________________________________________________________________ 17
3.1 K
3.2 D
3.3 P
3.3.1 F
3.3.2 R
EY FEATURES ELIVERY HYSICAL DESCRIPTION
RONT PANEL
EAR PANEL
___________________________________________________________________ 18
_______________________________________________________________________ 19
__________________________________________________________________ 19
___________________________________________________________________ 20
____________________________________________________________ 19
4 INSTALLATION ___________________________________________________________________ 21
4.1 M
4.2 C
4.3 U
4.3.1 I
4.3.2 U
4.4 U
4.5 U
4.6 R
July 2013 2.3 5/56
ECHANICAL ASPECTS ABLING REQUIREMENTS SING
USB I
NTERFACE
NSTALLING
SING THE
SING
RS-232 I
SING
10/100 E
ESTORING FACTORY CONFIGURATION
USB D
USB
NTERFACE
THERNET INTERFACE
____________________________________________________________ 21
___________________________________________________________ 21
____________________________________________________________ 22
RIVERS
INTERFACE
________________________________________________________ 22
_______________________________________________________ 22
_________________________________________________________ 23
_________________________________________________ 23
_______________________________________________ 24
Medio L40 - User's Guide
4.7 R
4.7.1 I
4.7.2 C
4.7.3 R
4.7.4 R
4.7.5 U
UNNING
NSTALLING TAGSYS EXPLORER
TAGSYS E
XPLORER FOR THE FIRST TIME
____________________________________ 24
____________________________________________________ 24
ONNECTING TO A DEVICE USING TAGSYS EXPLORER WIZARD EADING THE EADING AND WRITING PGRADING SYSTEM OR RADIO FIRMWARE
UID
OF
ISO 15693
ISO 15693
TAGS
_____________________________________________ 31
TAG MEMORY
_____________________________________ 32
__________________________________________ 33
__________________________ 26
5 ADVANCED NOTIONS ____________________________________________________________ 36
5.1 R
5.2 R
EADER ARCHITECTURE EADER TO HOST PROTOCOLS
___________________________________________________________ 36
______________________________________________________ 37
5.2.1 TAGSYS STXNG _______________________________________________________________ 37
5.2.2 H
5.2.3 T
5.2.4 S
5.2.5 S
5.3 R
5.3.1 N
5.3.2 N
EARTBEAT ELNET ERIAL CONSOLE TANDALONE MODE
EADER OPERATION PRINCIPLES
OTION OF READ MODES
OTION OF EVENTS
____________________________________________________________________ 37
________________________________________________________________________ 38
________________________________________________________________ 38
_____________________________________________________________ 39
_________________________________________________________ 40
______________________________________________________________ 40
_____________________________________________________ 39
6 TECHNICAL SPECIFICATIONS ____________________________________________________ 42
6.1 T
6.2 RS232 I
6.3 GPIO C
6.3.1 P
6.3.2 E
6.3.3 U
6.3.4 U
ECHNICAL DATA
NTERFACE
ONNECTOR IN ASSIGNMENT LECTRICAL CHARACTERISTICS
SING INPUTS SING OUTPUTS
_________________________________________________________________ 42
________________________________________________________________ 43
________________________________________________________________ 44 ________________________________________________________________ 44
__________________________________________________________________ 44
________________________________________________________________ 46
____________________________________________________ 44
7 ELECTRICAL CHARACTERISTICS _________________________________________________ 47
7.1 A
7.2 P
7.3 RS232 C
7.4 USB C
7.5 A
7.6 I
BSOLUTE MAXIMUM RATINGS OWER SUPPLY DC CHARACTERISTICS AND START-UP
OMMUNICATION PORT CHARACTERISTICS
OMMUNICATION PORT CHARACTERISTICS
NTENNA ELECTRICAL CHARACTERISTICS
NPUT / OUTPUT ELECTRICAL CHARACTERISTICS
______________________________________________________ 47
_____________________________________ 49
_______________________________________ 50
_____________________________________________ 50
_______________________________________ 51
__________________________________ 48
8 MECHANICAL CHARACTERISTICS ________________________________________________ 52
8.1 D
8.2 F
IMENSIONS AND GENERAL MECHANICAL INFORMATION
IXING THE PRODUCT
______________________________________________________________ 52
_________________________________ 52
9 WARRANTY CONDITIONS _________________________________________________________ 53
9.1 W
9.2 W
9.2.1 G
9.2.2 H
ARRANTY ARRANTY EXCLUSIONS
ENERAL PROVISIONS OW TO RETURN DEFECTIVE PRODUCTS
______________________________________________________________________ 53
___________________________________________________________ 53
___________________________________________________________ 54
____________________________________________ 54
10 MEDIO L40 PRODUCT END OF LIFE MANAGEMENT _______________________________ 56
6/56 Revision 2.3 July 2013
Medio L40 - User's Guide
July 2013 2.3 7/56
Medio L40 - User's Guide
1 For Your Safety
1.1 General Use
The Medio L40 reader is designed to be reliable and to provide continuous, trouble-free service. Please observe the following general tips:
Take care not to scratch the device. Keep the device clean. When working with the device,
use only TAGSYS-approved accessories.
This device is not waterproof and should not be exposed to rain or moisture. Under extreme
conditions, water may enter the circuitry.
Protect the device from extreme temperatures. For example, do not place the device in a
windowed area where the sun may cause extreme temperatures, and keep it away from heaters and other heat sources.
Do not store or use the device in any location that is extremely dusty, damp, or wet. Use a soft, damp cloth to clean the device. If the surface of the device becomes soiled,
clean it with a soft cloth moistened with a diluted window-cleaning solution.
MEDIO L40 shall be supplied by LPS (limited power source) power supply in accordance to
clause 2.5 of UL/IEC 60950-1 Edition 2 with following ratings 24Vdc, 1.6A min suitable for a minimum 40°C (104°F). Only use the recommended Powe r Supply Unit A2-50S18R-V manufactured by VP ELECTRONIQUE or VEH40US24 manufactured by XP Power.
1.2 Care and Maintenance
This device should be handled with care. The suggestions below will increase the lifetime of this device.
Keep the device and all parts and accessories out of the reach of small children.
Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode
electronic circuits.
Do not use or store the device in dusty, dirty areas. Its moving parts can be damaged.
Do not store in hot areas. High temperatures can shorten the life of electronic devices,
damage batteries and warp or melt certain plastics.
Do not store in cold areas. When the device warms up (to its normal temperature), moisture can form inside the device, which may damage electronic circuit boards.
Do not attempt to open the device. Non-professional handling of the device may damage it and will void the TAGSYS warranty.
Handle the device with care. Shock and vibration may break internal circuit boards.
Do not clean the device with harsh chemicals, cleaning solvents or strong detergents.
Gently wipe the device with a soft cloth slightly dampened in a mild soap-and-water solution.
Do not paint the device. Paint may clog the device’s moving parts and prevent proper operation. Paint with metallic contents may limit device performances.
If the device or any accessory are not working properly, take it to your nearest qualified TAGSYS representative.
8/56 Revision 2.3 July 2013
Medio L40 - User's Guide
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Please see section
and Electronic Equipment)
for more details.
2.3.2 WEEE (Waste Electrical
1.3 Important Safety Information
1.3.1 Operating Environment
When connecting the device or any accessory to another device, read its user’s guide for detailed safety instructions. Do not connect incompatible products.
As with all RF equipment, users are advised that the equipment should only be used in its normal operating mode described in this document.
July 2013 2.3 9/56
Medio L40 - User's Guide
2 Certification
2.1 Occupational Health and Safety Notices
TAGSYS Products have been designed not to exceed the limits given in the European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in conjunction with the European Standard EN 50357 describing how to evaluate the exposure level.
It is the responsibility of the TAGSYS Partner to install the Medio L40 as described in TAGSYS Documentation and with the appropriate antennas.
Modification of any TAGSYS System is prohibited without the written consent of TAGSYS. Unauthorized modifications may void the conformity of the equipment to safety standards and will void the TAGSYS warranty.
An RF fields survey has been carried out on all the TAGSYS System components, in accordance with AS/NZS 2771.1: Radio Frequency Radiation, Part 1. According to this standard the maximum allowable RF exposure levels (non-occupational) at 3 kHz to 300 GHz are 200 µW/cm2.
2.2 Regulatory Notices
An RFID system typically composed of an RF emission device such as the Medio L40 is subject to national regulations that may differ by country.
One important item to consider is the maximum permissible magnetic field intensity at a distance of 10 meters from the antenna that must not exceed 42 dBµA/m in Europe and 38 dBµA/m in US.
The Medio L40 meets these limits.
It is the responsibility of the TAGSYS Partner to install the Medio L40 as described in this User’s Guide or in TAGSYS Documentation.
2.2.1 In Europe (CE and RTTE Directives)
The Medio L40 complies (CE Declaration of Conformity granted) with the European EMC directive. The Medio L40 complies with the requirements of the Telecommunication Terminal Equipment Act
(FTEG) and the RTTE Directive 1995/5/EC. It is the responsibility of the TAGSYS Reseller to install the Medio L40 as described in this
Reference guide or TAGSYS Documentation. Any modification of the Medio L40 is prohibited without the written consent of TAGSYS.
Unauthorized modifications may void the conformity of the equipment to CE and RTTE Directives and will void the TAGSYS warranty.
If a Medio L40 is further integrated in a different product, it is the responsibility of the manufacturer of this complementary product to obtain the required approvals for this product.
2.2.2 FCC ID Cross Reference Table
It is the responsibility of the TAGSYS Partner to install the Medio L40 as described in the table below, taking care of only installing the right antenna configuration with the right power settings.
10/56 Revision 2.3 July 2013
Medio L40 - User's Guide
Table 1: Medio L40 FCC ID Cross reference Table
Antenna
Aero LB Antenna
Aero LC Antenna
L-SA3
Antenna
L-SA4
Antenna
MAT
Antenna
Outside Dimension
250X250
400X500
250X330
220X220
130X480
Channel Setting
Single Channel
Single Channel
Single Channel
Single Channel
Single Channel
Multiplexer
Single RF
Port
Single RF
Port
Single RF
Port
Single RF
Port
Single RF
Port
Max. Output Power
5W
5W
1.5W
1W
5W
Power Supply FCC ID
A2-50S18R-V
VEH40US24
QHKMEDIOL40
A2-50S18R-V
VEH40US24
A2-50S18R-V
VEH40US24
A2-50S18R-V
VEH40US24
A2-50S18R-V
VEH40US24
QHKMEDIOL40
QHKMEDIOL40
QHKMEDIOL40
QHKMEDIOL40
Laundry
Stack
Antenna
Antenna
Aero LB
Antenna
Aero LC Antenna
640x430
Single Channel
2W
Single RF
Port
A2-50S18R-V
VEH40US24
QHKMEDIOL40
To comply with band edge regulation, when used in vertical upright position the Aero LB and Aero LC antennas can read tags in the following RFID uplink protocols configurations
Table 2: Medio L40 FCC ID Cross reference Table
Outside Dimension
250x250
Channel Setting
Quad­Channel
Multiplexer
Active
Max. Output Power
5W
Power Supply FCC ID
A2-50S18R-V
VEH40US24
QHKMEDIOL40
5W
A2-50S18R-V
VEH40US24
QHKMEDIOL40
400X500
Quad­Channel
Active
5W
A2-50S18R-V
VEH40US24
QHKMEDIOL40
MAT
Antenna
July 2013 2.3 11/56
130x480
Quad­Channel
Active
Medio L40 - User's Guide
TR-CAU Antenna
Tunnel antenna
998x418
500X500
Two­Channel
Quad­Channel
3.5W
Active
2W
Active
A2-50S18R-V
VEH40US24
A2-50S18R-V
VEH40US24 TBL 060-124
ABL 7RM24025
QHKMEDIOL40
QHKMEDIOL40
To comply with band edge regulation, when used in vertical upright position the Aero LB antenna can read tags in the following RFID uplink protocols configurations
To comply with band edge regulation, when reading ISO15693 tags TR-CAU antenna can read tags in the following RFID uplink protocols configurations
In I-Code 1 (C270) parameters window set the uplink parameters as follow: Bit Coding: “Standard” (1 out of 256 pulse)
12/56 Revision 2.3 July 2013
Medio L40 - User's Guide
In ISO15693 Parameters window set the uplink parameters as follow: Command modulation depth: 10% (ASK) EOF modulation depth: 10% (ASK) Data coding mode: 1 of 256
July 2013 2.3 13/56
Medio L40 - User's Guide
2.2.3 In USA (FCC Directive)
The Medio L40 has been designed to comply with Part 15 of the FCC Rules. Furthermore typical configurations listed section 2.2.2 FCC ID Cross Reference Table have been successfully tested with Part 15 of the FCC rules (FCC ID Numbers are listed on all system-mounted TAGSYS Antennas).
Medio L40
WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNCIATIONS COMMISSION (FCC) RADIO
INTERFERENCE STATEMENT 47 CFR Section 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. ▪ Increase the separation between the equipment and receiver. ▪ Connect the equipment into an outlet on a circuit different to that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
NO UNAUTHORIZED MODIFICATIONS
47 CFR Section 15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without signed written permission from TAGSYS SA. Unauthorized modification may void the equipment authorization from the FCC and will void the TAGSYS warranty.
ANTENNA REQUIREMENT
47 CFR Section 15.203
CAUTION: This equipment must be professionally installed. The installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Non­professional installation or installation of the equipment with an improper antenna may void the equipment authorization from the FCC and will void the TAGSYS warranty.
Operation is subject to the following two conditions: (1) The system devices may not cause harmful interference, and (2) The system devices must accept any interference received, including interference that may cause undesired operation.
14/56 Revision 2.3 July 2013
Medio L40 - User's Guide
2.2.4 In Canada
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This radio transmitter (IC: 7562A-MEDIOL40) has been approved by Industry Canada to
operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 7562A-MEDIOL40) a été approuvé par Industrie Canada
pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
The Medio L40 device has been designed to operate with the antennas listed below, and
having a maximum gain of -25 dBi. Antenna not included in this list or having a gain greater than
-25 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Aero LB, Aero LC, LSA3, LSA4, Mat Antenna, Laundry Stack and TR-CAU antennas meet
this requirement with a gain less than -25dBi. Le lecteur Medio L40 a été conçu pour fonctionner avec les antennes citées ci-dessous et
ayant un gain maximum de -25dBi. Les antennes non inclus dans cette liste ou ayant un gain supérieur à -25dBi sont strictement interdites pour un usage avec ce lecteur. L’impédance de l’antenne doit être de 50 ohms. Les antennes Aero LB, Aero LC, LSA3, LSA4, Mat antenna, Laundry Stack et TR-CAU satisfont à cette exigence avec un gain inférieur à -25dBi.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
2.3 RoHS and WEEE Directives
2.3.1 RoHS (Restriction of the uses of certain Hazardous Substances)
TAGSYS certifies that this product is compliant with the European Directive 2002/95/EC for the restriction in Electric and Electronic Equipments (RoHS) of the use of the following hazardous substances:
Lead
July 2013 2.3 15/56
Medio L40 - User's Guide
Mercury
Cadmium
Hexavalent Chromium
Polybrominated biphenyl flame retardants
Polybrominated diphenyl ether flame retardants
This declaration is based on information provided by our suppliers and subcontractors.
2.3.2 WEEE (Waste Electrical and Electronic Equipment)
This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment. For further information, please contact your local or regional authorities.
16/56 Revision 2.3 July 2013
Medio L40 - User's Guide
3 Overview
The Medio L40 is a long-range 13.56MHz RFID reader intended for RFID applications
requiring a high performance, long range RFID infrastructure.
The L40 uses advances in Digital Signal Processing (DSP) and RF Front End technology to achieve breakthrough performance in read range and read speed with industry leading signal to noise ratio. The L40 has been specifically designed to operate in noisy environments such as manufacturing plants and distribution facilities while maintaining the highest levels of data integrity for item level track and trace, inventory management and security. Designed as a network device, the L40 conserves critical network bandwidth by filtering tag data to remove redundancies before transmitting to enterprise systems.
With breakthrough sensor technology and self-diagnostic capability, the L40 is the industry’s first self-correcting intelligent RFID reader. The L40 can be remotely managed and administered to ensure you get the highest levels of performance from your RFID infrastructure. The L40 and e­connectware, TAGSYS’ comprehensive set of management and administrative tools, create an intelligent platform to allow you to manage your RFID infrastructure just as you do a voice or data network to enable scalable, secure and persistent RFID Quality of Service.
July 2013 2.3 17/56
Loading...
+ 39 hidden pages