All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and
keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such
information.
Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any
intellectual and/or industrial property rights of or concerning any of TAGSYS’ information.
This document can be used for informational, non-commercial, internal and personal use only provided that:
The copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all
copies.
This document shall not be posted on any network computer or broadcast in any media and no modification of
any part of this document shall be made.
Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities.
The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise
expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein.
The document could include technical inaccuracies or typographical errors. Changes are periodically added to the
information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications
data, information, and the like described herein, at any time.
Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software that
include TAGSYS products.
TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION
CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER
IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY
DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE,
DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT.
TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and
shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security
standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the
state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be
held liable for any third party actions, and in particular in case of any successful attack against systems or equipment
incorporating TAGSYS products.
TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result
from any use of its products. It is further stressed that independent testing and verification by the person using the
product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning
could result in damage to persons or property, denial of service, or loss of privacy.
TRADE MARKS. TAGSYS is a registered trademark of TAGSYS S.A, all rights reserved. ARIO, FOLIO and other
TAGSYS products referenced in these pages are either trademarks or registered trademarks of TAGSYS S.A. Other
products and company names mentioned in these pages may be the trademarks of their respective owners.
Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft
Corporation in the U.S.A. and/or other countries.
I-Code is a registered trademark of NXP.
Tag-It is a registered trademark of Texas Instruments.
Printed in France.
TAGSYS – 180 Chemin de St Lambert, F-13821 LA PENNE SUR HUVEAUNE, France.
Welcome to the TAGSYS L-SP3 Electronic Article Surveillance (EAS) system. This user’s guide is
designed to help you get up and running quickly using this high-quality Radio Frequency
Identification (RFID) Anti-Theft system. It describes all you need to know about how to install and
use the TAGSYS EAS/AFI system and its associated applications.
It provides a step-by-step guide for the following procedures:
Installation of the L-SP3 EAS/AFI anti-theft and RFID Data Retrieval system
Configuring the system for use in your library
Personalizing your product with your own preference settings
After you become familiar with the basic functions of the product, you can use the rest of this
handbook as a reference for less common tasks, for maintaining your system, and also as a
source of information if you have problems operating the system.
This End User’s Guide is designed for all CIT (Certified Integrators by TAGSYS) and for TAGSYS
Expert Network customers implementing a low-cost and high-performance RFID solution.
This document does not assume any in-depth knowledge of Radio Frequency Identification (RFID)
technology, but personnel in charge of pedestal installation need to follow a minimum training or
have previous experience in RFID equipment installation.
Conventions
Symbol Meaning
CAUTION: A note that advises users that a specific action could result in
loss of data or damage the hardware.
WARNING: A note that advises users that a specific action may result in
physical harm.
A note that provides additional information that helps the user
performing a task or obtaining the most out of the product.
April 2009 Revision 0.9 3/63
Library Security Pedestal 3 Clear
If you need assistance
Please contact your nearest TAGSYS sales representative or the TAGSYS Welcome Desk at:
Telephone: +33 (0) 4 91 27 57 00
Fax: +33 (0) 4 91 27 57 01
E-Mail: info@tagsysrfid.com
Website http://www.tagsysrfid.com
Contact for Comments
We welcome your feedback to help us provide high quality documentation.
For technical comments, please contact our Welcome Desk:
Telephone: +33 (0) 4 91 27 57 00
Fax: +33 (0) 4 91 27 57 01
E-Mail: info@tagsysrfid.com
Please remember to quote the Document Reference number DOC12984A9, your job title and your
company.
Quality Issues
TAGSYS implements stringent quality controls at all stages of its manufacturing process. However,
should you find a defect with this product, please notify your TAGSYS Quality Service
representative using the dedicated Product Return Form.
Telephone: +33 (0) 4 91 27 57 00
Fax: +33 (0) 4 91 27 57 02
E-Mail:
RMA@tagsysrfid.com
4/63 Revision 0.9 April 2009
Table of Contents
PUBLISHING INFORMATION __________________________________________________________ 2
The L-SP3 is designed to be rugged and reliable and to provide years of trouble-free
service. Please observe the following general tips:
Take care not to scratch the device. Keep the device clean. When working with the device,
use only TAGSYS-approved accessories.
This device is not waterproof and should not be exposed to rain or moisture. Under extreme
conditions, water may enter the circuitry.
Protect the device from extreme temperatures. For example, do not place the device in a
windowed area where the sun may cause extreme temperatures, and keep it away from
heaters and other heat sources.
Do not store or use the device in any location that is extremely dusty, damp, or wet.
Use a soft, damp cloth to clean the device. If the surface of the device becomes soiled,
clean it with a soft cloth moistened with a diluted window-cleaning solution.
1.2 Care and Maintenance
This device is a high end design and should be handled with care to maintain its
appearance in public locations. The suggestions below will further increase the lifetime and day
to day appearance of this device.
Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode
electronic circuits and tarnish transparent plastic parts.
Do not store the device in dusty, dirty areas. Its moving parts can be damaged.
Regularly dust the large transparent part using a soft cloth and antistatic liquid.
Do not store in hot areas. High temperatures can shorten the life of electronic devices,
damage batteries and warp or melt certain plastics.
Do not store in cold areas. When the device warms up (to its normal temperature), moisture
can form inside the device, which may damage electronic circuit boards.
Do not attempt to open the device during operation, outside installation and maintenance
periods. Non-professional handling of the device may damage it.
Handle the device with care. Shocks may break internal circuit boards.
Do not paint the device. Paint may clog the device’s moving parts and prevent proper
operation. Paint with metallic contents may limit device performances.
If the device or any accessory are not working properly, take it to your nearest qualified
TAGSYS representative.
Do not clean the device, particularly the transparent plastic parts, with harsh
chemicals, cleaning solvents or strong detergents. Gently wipe the device with a soft
cloth slightly dampened in a mild soap-and-water solution. Eliminate any residual
moisture with another clean and wet soft cloth.
Also regularly apply specific antistatic products for Acrylic Surfaces.
10/63 Revision 0.9 April 2009
1.3 Important Safety Information
1.3.1 Operating Environment
When connecting the device or any accessory to another device, read its user’s guide for
detailed safety instructions. Do not connect incompatible products.
As with any RF equipment, users are advised that the equipment should only be used in its normal
operating position.
April 2009 Revision 0.9 11/63
Library Security Pedestal 3 Clear
2 Certification
2.1 Occupational Health
TAGSYS L-SP3 EAS System has been designed and tested to be in conformity with the
European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from
devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and
similar applications” in conjunction with the European Standard EN 50357 describing how to
evaluate the exposure level.
2.1.1 Public Exposure
The Library RFID pedestals are designed assuming that patrons cross the detection area within a
couple of seconds on their way in and out of the Library at a normal walking pace. General public
should not stand in the detection area for more than 10 to 20 seconds.
Librarian should make sure that nobody stands still in the Gate
Detection Area in between two RFID Pedestals to avoid unnecessary
prolonged Exposure to Electromagnetic Field.
2.1.2 Employees Exposure
The operators are located apart from the principal detection zone and as a matter of fact,
not subject to exposure.
(Please see section 4.3.2 “Placement of Pedestals”)
For servicing operations it is recommended to deactivate the RFID
system.
2.2 Safety Notices
The L-SP3 has been tested to be in conformity with the EN standard 60950-1: “Information
Technology Equipment Safety”
It is the responsibility of the CIT (Certified Integrators by TAGSYS) to install the L-SP3 as
described in TAGSYS Product Manuals or TAGSYS Documentation.
Modification of any TAGSYS Library System is prohibited without the written consent of TAGSYS.
Unauthorized modifications may void the conformity of the equipment to safety specifications and
will void the TAGSYS warranty.
2.3 Regulatory Notices
An RFID system typically composed of an RF emission device such as the L-SP3 connected
to an antenna is subject to national regulations that may differ by country.
One important item to consider is the maximum permissible magnetic field intensity at a distance of
10 meters from the antenna that must not exceed 60dBµA/m in Europe and 38dBµA/m in US.
The L-SP3 meets these limits.
12/63 Revision 0.9 April 2009
2.3.1 In Europe (CE and RTTE Directives)
The L-SP3 complies (CE Declaration of Conformity granted) with the European EMC
directive.
The L-SP3 complies with the requirements of the Telecommunication Terminal Equipment Act
(FTEG) and the RTTE Directive 1995/5/EC.
It is the responsibility of the TAGSYS Reseller to install the L-SP3 as described in this User’s
Guide or TAGSYS Documentation.
Any modification of the L-SP3 is prohibited without the written consent of TAGSYS. Unauthorized
modifications may void the conformity of the equipment to CE and RTTE Directives and will void
the TAGSYS warranty.
It is the responsibility of the CIT (Certified Integrators by TAGSYS) to
install the L-SP3 as described in this Reference Guide or in TAGSYS
Documentation.
If an L-SP3 is further integrated in a different product, it is the
responsibility of the manufacturer of this complementary product to
obtain the required approvals for this product.
April 2009 Revision 0.9 13/63
2.3.2 In USA (FCC Directive)
L-SP3 Clear
WARNING TO USERS IN THE UNITED STATES
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO
INTERFERENCE STATEMENT 47 CFR Section 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and if not installed and used in accordance with the
instructions may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
▪ Reorient or relocate the receiving antenna.
▪ Increase the separation between the equipment and receiver.
▪ Connect the equipment into an outlet on a circuit different to that to which the receiver is
connected.
▪Consult the dealer or an experienced radio/TV technician for help.
NO UNAUTHORIZED MODIFICATIONS
47 CFR Sections 15.21
CAUTION: This equipment may not be modified, altered, or changed in any way without signed
written permission from TAGSYS SA. Unauthorized modification may void the equipment
authorization from the FCC and will void the TAGSYS warranty.
ANTENNA REQUIREMENT
47 CFR Sections 15.203
CAUTION: This equipment must be professionally installed. The installer shall be responsible for
ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Nonprofessional installation or installation of the equipment with an improper antenna may void the
equipment authorization from the FCC and will void the TAGSYS warranty.
The L-SP3 has been designed to comply with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) The system devices may not cause harmful
interference, and (2) The library system devices must accept any interference received, including
interference that may cause undesired operation.
April 2009Revision 0.9 14/63
Figure 1: FCC power and uplink settings
CAUTION: In any case, for operational configuration this value should not exceed 4W to be in
compliance with FCC. The “Antennas and Power” parameter in “Advanced Configuration” Tab
does not allow setting a higher power value than 4.0W at most. Please see above Figure 1:
FCC power and uplink settings.
CAUTION: ISO15693 uplink data rate you should not exceed 1.65kbits/s in order to comply
with FCC standard certification. To do so, set the “Region” parameter in “Advance
Configuration” Tab to “FCC”. See above Figure 1: FCC power and uplink settings.
April 2009 Revision 0.9 15/63
Library Security Pedestal 3 Clear
3 System Overview
3.1 Features
Being a standalone solution, TAGSYS security pedestal do not need to be linked to the
library database, and can still operate when the Integrated Library System (ILS) is down or under
maintenance. The security pedestal does not require additional equipment to operate.
The L-SP3 pedestal features:
Multi-protocol features which makes it compatible with ISO15693 chips
EAS mode supported for the C370 (NXP SLI), C370-L (NXP SLI-L) chips
AFI mode supported, with configurable AFI value (Multiple AFI values, up to 4)
Multiple items Read-Memory supported in EAS mode for C370 (NXP SLI), C370-L
(NXP SLI-L)
Standard Multiple items Read-Memory supported in AFI mode using the optional
command Read Multiple Blocks as described by the ISO15693-3
Enhanced Multiple items Read-Memory supported in AFI mode for C370 (NXP SLI),
Read-Memory Data Model: up to 512-bits (16 blocks)
One electronic system block embedded into bottom of Pedestal
A remotely accessible people counter based on dual photoelectric sensors coupled to a
reflector, allowing in and out traffic monitoring.
Ethernet Networking Link communication for set up, database and patron counter value
retrieval
Trigger input to quickly power up and down remotely the pedestals using light cells
before and after the pedestal area. This lowers down the radio emission levels to the
strict minimum necessary.
One Extra Open Drain Output to drive External Alarm Device: Webcam, Extra Remote
Display or Sound…
This is a low-cost security system as it only requires a single RFID tag for both anti-theft and
identification purposes.
16/63 Revision 0.9 April 2009
3.2 Brief L-SP3 Clear Description
Figure 2: LSP3 Clear Panel Overview
April 2009 Revision 0.9 17/63
Library Security Pedestal 3 Clear
The components of the L-SP3 EAS system are contained within the L-SP3 pedestal. At
least two pedestals are required for each EAS gate. A set of pedestals is known as a gate and may
consist of several pedestals. Please see section 4 “Installation” for more information.
The L-SP3 is built in a one frame:
An L-SP3 Electronics unit is used to control each pedestal. This electronics unit
generates the RF signal transmitted by the antennas and picks up the reply from the
RFID tag. If an activated RFID tag is detected, the electronics unit will activate the
LED/buzzer alarm
These antennas are sensitive receivers used to detect the theft bit status and the AFI
value of the RFID tag as it passes through the EAS gate
Visual and audible warning devices
A remotely accessible people counter equipped with dual light barrier photoelectric
sensors.
To operate, the L-SP3 will only need an IEC power supply cable, avoiding unnecessary mains
cable wiring up.
An IEC Mains Supply Cord Outlet is available to allow daisy chaining. A series of up to 5 pedestals
can be powered up from a single wall socket.
18/63 Revision 0.9 April 2009
4 Installation
4.1 Recommendations before Installation
4.1.1 Wire Feed Sheaths
Within the framework installation you need at least a power supply cable sheath and an
Ethernet cable sheath to connect to the Ethernet network. These sheathed cables will be located at
the bottom center of the pedestal as shown in Figure 8.
If needed according to the installation configuration, extra sheathed cables need to placed
for wire synchronization, Trigger cable and to remotely switch the RF on & off and I/O cables to
drive external devices (Camera, Remote alarms…).
The L-SP3 is delivered without any IEC terminated plug power supply cable or Telecommunication
cable. It is up to the Local installation personnel to use the appropriate IEC Power Cord according
to local electrical regulations.
Use appropriate IEC power cord according to the local regulations to
power up and interconnect the pedestals.
The Power Supply Cord is the LSP3 Product Main Disconnecting Device,
It should be easily accessible at any time to Disconnect the pedestals
from the mains power supply.
April 2009 Revision 0.9 19/63