TAG SV-2002-X2 Operation Manual

TAG
Dulles, VA 20166
SV-2002-X2 Server Operations Manual 247-MNL-004
Operations Manual
1 Copyright © 2008 Technology Advancement Group®, Inc.
(TAG®)
All rights reserved. This publication and its contents are proprietary to TAG. No part of this publication may be reproduced in any form or by any means without the written permission of TAG, 22355 TAG Way, Dulles, Virginia 20166-9310.
TAG has made every effort to ensure the correctness and completeness of the material in this document. TAG shall not be liable for errors contained herein. The information in this document is subject to change without notice. TAG makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
1.1 Trademarks
All trademarks, marks, names, or product names referenced in this publication are the property of respective owners, and TAG neither endorses nor otherwise sponsors any such products or services referred to herein.
Product Number-247 MNL-004 Page 2 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
2 About TAG
2.1 Summary of Qualifications
TAG has served as a leading provider of IT solutions to DoD customers over the past 20+ years and has a long-standing and respected history of providing Systems Engineering, Electronic Equipment and Program Management support to US Military warfighters. Headquartered in Dulles, Virginia, TAG’s state-of-the-art 35,000 sq. ft. engineering and manufacturing facility provides all the infrastructure, equipment, and manpower necessary to engineer, design, test, manufacture, and certify products to the rugged requirements of the tactical combat theater. Our facilities in Dulles, VA, San Diego, CA, and St. Louis, MO, allow for rapid deployment of products and support across the globe.
TAG quickly, efficiently, and cost-effectively tailors rugged solutions for large DoD programs with specific MIL-STD requirements. TAG’s comprehensive Quality Assurance (QA) policy – enforced through application of our UL-registered ISO 9001:2000 certified processes – enables TAG to rapidly deploy systems and solutions that reliably withstand the stresses of the tactical environment. Today, there are over 20,000 TAG systems deployed across various weapons platforms throughout the US Military. TAG effectively balances all corporate assets – our people, expertise, infrastructure, and experience – to consistently and successfully execute and deliver to the DoD.
TAG’s success lies in focusing on the corporate Mission Statement and leveraging the tenets of
our business model to ensure the customer’s
expectations are exceeded throughout lengthy program lifecycles.
TAG’s Mission is to resolve our customers’ IT
challenges with World-Class:
Engineering; Manufacturing and Integration; and
Lifecycle Management
TAG has a proven track record in implementing these tenets to serve as a trusted advisor to our Government customers. TAG uses this foundation to ensure risk is mitigated, expectations are exceeded, and the customer can consistently rely on the company, our equipment, and our services.
Product Number-247 MNL-004 Page 3 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
2.2 Core Competences
2.2.1 Engineering
TAG’s engineering methodology is built upon Multi-Disciplinary Optimization (MDO) and rigorous design reviews. Although PMs drive the schedule at TAG, Engineering leverages Computer-Aided Design (CAD) tools, Computational Fluid Dynamics (CFD) models, rapid prototyping processes, and diverse test equipment and facilities to ensure requirements are being met at every step of the design. TAG Engineering follows a proven design-review process, ensuring all entrance and exit criteria are met at each stage. Rigorous documentation is compiled to demonstrate requirement compliance, risks are mitigated, and decisions are prudent – throughout the design process.
TAG prides itself on its engineering laboratories and facilities. Over the past three years, TAG has invested in several pieces of equipment that allow TAG to test and certify products directly onsite to the harshest environmental requirements of military standards – including the MIL-STD-810F and DO 160D.
TAG’s onsite test equipment currently includes a Highly Accelerated Lifecycle Testing (HALT) Chamber, an Electromagnetic Interference (EMI) test chamber, and a high-/low-temperature thermal test chamber. TAG’s facility also provides:
Floor plan designed to support a cellular manufacturing model with modular assembly
lines
A dedicated 24-hour system burn-in room A modern production status tracking and Enterprise Resource Planning (ERP) system
with external web collaboration capabilities
Dedicated Quality Assurance workstations for system compliance and validation
inspection
2.2.2 Manufacturing and Integration
TAG implements Cellular Manufacturing processes through our compartmentalized, state-of-the­art production facility to minimize waste byproducts and maximize production efficiency. TAG’s manufacturing facility is physically partitioned to model the major philosophies of Lean Manufacturing. Consistent with the model, each of TAG’s production cells are capable of operating in isolation; however personnel and tools are shared across all cells to streamline manufacturing operations, costs, and the production/integration schedule. TAG’s floor
Product Number-247 MNL-004 Page 4 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
technicians are cross-trained in multiple disciplines so they can be redistributed to any cell that encounters production bottlenecks, which ensures optimal efficiency.
2.2.3 Lifecycle Management
TAG’s world-class Program Management discipline models the renowned methodologies of the Project Management Institute (PMI) to ensure successful completion of the task at hand. Our Program Managers (PMs) serve as the voice of the customer – driving requirements to which the
rest of TAG’s organization answers. As an explicit tenet of TAG’s corporate mission statement, the PMs not only track cost, schedule, and technical compliance throughout a project’s period of
performance, but also ensure the customer is supported well beyond it.
Product Number-247 MNL-004 Page 5 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
2.3 About TAG
2.3.1 Summary of Qualifications.
Providing engineering services and solutions for our national defense and homeland security is a responsibility that we don't take lightly.
TAG is a recognized industry leader in developing defense technologies and advanced electronics that support some of the most complex solutions for battlespace information networks and management systems in the world.
Our customers depend on our expertise to translate functional requirements and performance objectives into specific design criteria for individual elements and sub­systems that comprise larger mission critical systems. For more than twenty years, we have dedicated our experience in engineering to the design of innovative rugged solutions for military and government, and to providing a wide range of enterprise services and Information Assurance in support of the Defense Information Systems Agency's (DISA) Net-Centric initiatives.
2.3.2 Core Competencies
TAG designs, manufactures, and supports advanced communications electronics as well as integrates, operates, and supports the users of defense communication and information networks for several technology programs in the United States and abroad. TAG has two operating segments consisting of the Rugged Systems and Information and Engineering Services business units;
Rugged Systems provides mechanical, electrical, and thermal engineering for the design and development of MIL-STD certified electronic data enabled systems that are built
SV-2002-X2 Server
Product Number-247 MNL-004 Page 6 of 84
Version 1.4. 01/12/2010
Operations Manual
for in-theater survivability and communication capability over joint enterprise platforms such as DSN, GIG, STEP, GBS, and JTRS. This includes the custom ruggedization of commercial-off-the-shelf (COTS) and non­developmental items (NDI). TAG's mechanical engineering division designs and fabricates custom hardened enclosures, using high performance metal materials, to house and protect a variety of sensitive devices and controls. TAG's electrical engineering division designs programmable power solutions and advanced sensor technologies including digital receivers, advanced digital signal processors and thermal detection systems. TAG's thermal engineering applies survivability techniques to ensure systems and instruments are designed to withstand harsh environmental conditions encountered by land-based, airborne, and shipboard system in operations
Information and Engineering Services provides a wide range of customer support operations, enterprise network and communications engineering services combining the experience and expertise required to achieve network and communication interoperability for component hardware and software elements. This includes design, simulation, analysis, and testing of the components or systems for the support of command and control operations. Our team of national security cleared network engineering professionals provides planning support for information systems, architectures, and networks while developing strategies that lay the groundwork for sound technical foundations for programmatic plans. Our expertise in analyzing, designing, implementing, and managing network, telecommunication and security solutions addresses the full lifecycle approach to providing mission oriented enterprise class services.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 7 of 84
Version 1.4. 01/12/2010
Date
Version Number
Updated By
Description of
Changes
01/29/2008
1.0
Alan Huckerby
Author
04/10.2008
1.1
Alan Huckerby
Author
10/01/09
1.2
Sean Legg
Draft Update
10/26/2009
1.3
Alan Huckerby
Update
01/12/2010
1.4
Alan Huckerby
Update
Operations Manual
Document Revision History
Product Number-247 MNL-004 Page 8 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
3 About This Manual
3.1 Scope and Audience
3.1.1 Organization:
This manual provides information on the SV-2002-X2
Server. The rugged SV-2002-X2 Server allows for up to 16
cores in a 2U chassis as well as up to 64GB of RAM. The Server meets military standards such as shock, vibration, and humidity. TAG built the SV-2002-X2 to relieve potential problems with a single failing power supply and to create a product that end users can rely on. Each Server features two 2.33GHz dual-core INTEL® XEON 5149 processors to maximize the processing power. The SV-2002-X2 is ideal for transit case and deployable situations where such high density computing minimizes size, weight, and power.
This manual is divided into the following chapters and appendix:
Chapter 1 provides Cautions and Warnings.  Chapter 2 provides detailed information on the external and
internal Server components.
Chapter 3 provides procedures for replacing Hot-Swappable
and LRU components, as well as for replacing or adding system memory.
Chapter 4 provides a high-level overview that defines RAID,
the advantages and disadvantages of various RAID levels, and guidelines to observe when implementing RAID.
Product Number-247 MNL-004 Page 9 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Table of Contents
Contents
1 Copyright © 2008 Technology Advancement Group®, Inc. (TAG®) ...................................... 2
1.1 Trademarks........................................................................................................................ 2
2 About TAG ............................................................................................................................. 3
2.1 Summary of Qualifications ................................................................................................ 3
2.2 Core Competences ............................................................................................................. 4
2.2.1 Engineering ................................................................................................................. 4
2.2.2 Manufacturing and Integration ..................................................................................... 4
2.2.3 Lifecycle Management ................................................................................................. 5
2.3 About TAG ....................................................................................................................... 6
2.3.1 Summary of Qualifications. ......................................................................................... 6
2.3.2 Core Competencies ...................................................................................................... 6
3 About This Manual.................................................................................................................. 9
3.1 Scope and Audience .......................................................................................................... 9
3.1.1 Organization: ............................................................................................................... 9
4 Safety Instructions ................................................................................................................... 15
4.1 Types of warnings used in this manual............................................................................... 15
4.1.1 Safety Symbols and Labels .......................................................................................... 15
4.1.2 Conventions ................................................................................................................. 16
5 Server Overview...................................................................................................................... 18
5.1 Product Information ........................................................................................................... 18
5.2 SV-2002-X2 Server ................................ ........................................................................... 19
5.2.1 Specifications .............................................................................................................. 19
5.2.2 Additional specifications .............................................................................................. 20
5.2.3 SV-2002-X2 Server Highlights .................................................................................... 20
5.2.4 SV-2002-X2 Server ..................................................................................................... 21
5.3 Server Components ........................................................................................................... 21
5.3.1 Motherboard Model and Type ...................................................................................... 21
5.4 System Memory ................................................................................................................ 22
5.4.1 Identifying System Memory......................................................................................... 22
5.5 Identifying your I/O Connectors ........................................................................................ 22
5.6 Standard Server Components ............................................................................................. 23
5.6.1 Floppy Drives .............................................................................................................. 23
5.6.2 SCSI HP 920 LTO-3 Ultrium tape drive ...................................................................... 23
5.6.3 D/DVD Drive .............................................................................................................. 24
5.6.4 Dual-redundant, auto-sensing power supply ................................................................. 25
5.7 PCI I/O Expansion Cards ................................................................................................... 27
5.7.1 Adaptec 5805 SAS/SATA RAID Controller ................................................................ 27
5.7.2 Adaptec 29320 ALP-R SCSI Controller ....................................................................... 28
6 Procedures ............................................................................................................................... 30
SV-2002-X2 Server
Product Number-247 MNL-004 Page 10 of 84
Version 1.4. 01/12/2010
Operations Manual
6.1 Server Startup .................................................................................................................... 30
6.2 Server Shutdown ............................................................................................................... 30
6.3 Identifying Server Components Using Device Manager ..................................................... 30
6.4 Working with Device Properties ........................................................................................ 33
6.5 Installing and Removing Hardware in Windows ................................................................ 35
6.5.1 Using the Add New Hardware Wizard ......................................................................... 35
6.6 Installing Legacy Peripherals ............................................................................................. 37
6.6.1 Removing Legacy Peripherals ...................................................................................... 37
6.7 TAG Approved BIOS ........................................................................................................ 40
6.7.1 Common BIOS Settings ............................................................................................... 40
6.8 Bios Configuration for SV-2002-X2 .................................................................................. 44
6.9 Upgrading Memory and Replacing Hot-Swap and LRU Components ................................ 53
6.9.1 Preventing Static Electricity ......................................................................................... 53
6.10 Replacing a Hot-Swap Power Supply Module.................................................................... 54
6.11 Replacing a Hot-Swap Hard Drive ..................................................................................... 55
6.11.1 146GB SAS Hard Drive ............................................................................................ 56
6.12 Removing the Server Cover ............................................................................................... 56
6.13 Adding or Replacing System Memory ............................................................................... 57
6.13.1 Install system memory. .............................................................................................. 58
6.14 Replacing the CMOS Battery............................................................................................. 58
6.15 Ultrium 920 Tape Drive ..................................................................................................... 60
6.15.1 Remove Tape Drive ................................................................................................... 60
6.15.2 Install Tape Drive ...................................................................................................... 60
7 RAID ...................................................................................................................................... 63
7.1 RAID Defined ................................................................................................................... 63
7.1.1 RAID Level 5 .............................................................................................................. 64
7.2 Create a RAID 5 Array On Adaptec 5805 .......................................................................... 65
7.3 About RAID Global and Hot Spares .................................................................................. 83
7.4 Global and Dedicated Hot Spares ...................................................................................... 83
Product Number-247 MNL-004 Page 11 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
List of Figures
Figure 5-1 SV-2002-X2 (Front View) .................................................................................... 18
Figure 5-2 SV-2002-X2 Server Components and Connectors (Front View) .................... 21
Figure 5-3 I/O Connectors ..................................................................................................... 23
Figure 5-4 Low Profile Internal Floppy Drive ....................................................................... 23
Figure 5-5.5 Internal Tape Drive ........................................................................................... 24
Figure 5-6 Slot-loading low-profile DVD±R (DL)/-RAM/CD-RW Drive .............................. 24
Figure 5-7 Hot-Swap Power Supply ..................................................................................... 26
Figure 5-8 Adaptec 5805 RAID Card ................................................................................... 27
Figure 5-9 Adaptec 29320 ALP-R SCSI Controller ............................................................. 28
Figure 6-1 Control Panel........................................................................................................ 31
Figure 6-2 System Properties. .............................................................................................. 31
Figure 6-3 Device Manger ..................................................................................................... 32
Figure 6-4 Device Manager ................................................................................................... 33
Figure 6-5 Properties Dialog Box .......................................................................................... 34
Figure 6-6 Control Panel........................................................................................................ 36
Figure 6-7 Add hardware Wizard .......................................................................................... 36
Figure 6-8 Control Panel........................................................................................................ 37
Figure 6-9 System Properties ............................................................................................... 38
Figure 6-10 Device Manger ................................................................................................... 39
Figure 6-11 Quiet Boot........................................................................................................... 44
Figure 6-12 Load Optimized Defaults ................................................................................... 45
Figure 6-13 Enhanced Intel ................................................................ ................................... 46
Figure 6-14 Enhanced Intel, Disable .................................................................................... 47
Figure 6-15 Processor Confirmation Screen ....................................................................... 48
Figure 6-16 Deep C-state Support Screen .......................................................................... 49
Figure 6-17 USB Configuration ............................................................................................. 50
Figure 6-18 Intel Virtualization Technology ......................................................................... 51
Figure 6-19 Save and Reset ................................................................................................. 52
Figure 6-20 Grounding Wrist Strap ....................................................................................... 53
Figure 6-21 Hot-Swap of 2U Server Power Supply Module ............................................... 55
Figure 6-22 146GB SAS HDD (Removed from HD Carrier) .............................................. 56
Figure 6-23 DIMM Module Bank ........................................................................................... 58
Figure 7-1 Array Configuration .............................................................................................. 65
Figure 7-2 Initialize Drives ..................................................................................................... 66
Figure 7-3 Select Drives ........................................................................................................ 67
Figure 7-4 Initialization Warning ........................................................................................... 67
Figure 7-5 Initialized ............................................................................................................... 67
Figure 7-6 Create Array ................................................................ ......................................... 69
Figure 7-7 Select Drives ........................................................................................................ 70
Figure 7-8 RAID 5 .................................................................................................................. 71
Figure 7-9 Array Label ........................................................................................................... 72
Product Number-247 MNL-004 Page 12 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Figure 7-10 Array Size ........................................................................................................... 73
Figure 7-11 Stripe Size .......................................................................................................... 74
Figure 7-12 Read Caching .................................................................................................... 75
Figure 7-13 Cache Functionality ........................................................................................... 76
Figure 7-14 Write Caching ..................................................................................................... 77
Figure 7-15 Build/Verify ......................................................................................................... 78
Figure 7-16 Press Enter ......................................................................................................... 79
Figure 7-17 Cache Warning .................................................................................................. 80
Figure 7-18 Hot Spare Check ............................................................................................... 81
Figure 7-19 Exit Utility ............................................................................................................ 82
Product Number-247 MNL-004 Page 13 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Chapter 1
Cautions and Warnings.
Electronically distributed. Subject to user discretion when printed.
Product Number-247 MNL-004 Page 14 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
These warnings and cautions indicate situations or practice that might result in property damage or injury. These hazard indicators are not present on all TAG products; they are only present where applicable.
Operations Manual
4 Safety Instructions
4.1 Types of warnings used in this manual
Read this manual thoroughly, paying special attention to the cautions and warnings.
4.1.1 Safety Symbols and Labels
Product Number-247 MNL-004 Page 15 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
4.1.2 Conventions
4.1.2.1 Important Messages
Important messages appear where mishandling of components is possible or when work orders can be misunderstood. These messages also provide vital information associated with other aspects of system
operation. The word “important” is written as
IMPORTANT,” both capitalized and bold and
is followed by text in italics. The italicized text is the important message.
4.1.2.2 Warnings
Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously. Warnings are easy to recognize. The
word “warning” is written as “WARNING,” both
capitalized and bold and is followed by text in italics. The italicized text is the warning message.
4.1.2.3 Cautions
Cautionary messages should also be heeded to help you reduce the chance of losing data or damaging the system. Cautions are easy to
recognize. The word “caution” is written as
CAUTION,” both capitalized and bold and is
followed by text in italics. The italicized text is the
cautionary message.
4.1.2.4 Notes
Notes inform the reader of essential but non­critical information. These messages should be read carefully as any directions or instructions contained therein can help you avoid making mistakes. Notes are easy to recognize. The
word “note” is written as “NOTE,”
SV-2002-X2 Server
Product Number-247 MNL-004 Page 16 of 84
Version 1.4. 01/12/2010
Operations Manual
Chapter 2
SV-2002-X2 2U Server.
Electronically distributed. Subject to user discretion when printed.
Product Number-247 MNL-004 Page 17 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5 Server Overview
5.1 Product Information
This chapter provides an introductory overview of the TAG family of rugged Servers. TAG Servers are highly customizable; the specific components vary depending on the mission requirements. Your system may contain components not described in this chapter. For detailed information on these components, refer to the manufactures website or contact TAG Technical Support at
tech.support@tag.com.
TAG's rugged Servers combine two 2.33GHz dual-core Intel® Xeon processors with state-of­the-art mechanical, thermal and electrical engineering to create customized systems that perform above and beyond end user or program specifications. Our rugged Servers are designed to meet and exceed many MIL­STD requirements to ensure survivability in the field. Figure 5-1 shows a SV-2002-X2 with off the shelf standard configuration.
Product Number-247 MNL-004 Page 18 of 84
Figure 5-1 SV-2002-X2 (Front View)
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5.2 SV-200 2-X2 Server
All specifications detailed below are for the standardized version of the SV-2002-X2
5.2.1 Specifications Chassis & power supply:
2U Heavy-duty, 090inch
Aluminum/Magnesium alloy, rack-mount chassis
3.5”H x 19”W x 20”D (approx)  Redundant, Hot-Swap, auto-sensing power
supplies
Cooling system developed specifically for
harsh environments
Front accessible on/off switches (2) Front Accessible USB 2.0 Ports
Fan Controller Processor & Cache:
Intel 5000P Chipset, 1333MHz FSB
Motherboard and On-board Features:
On-board graphics controller with 16MB of
RAM.
(2)USB 2.0 Ports at rear (2) 10/100/1000 Ethernet ports (2) PCI-Express slots (1) PCI-X Expansion slot One USB 2.0 Header brought out to front of
chassis
PS/2 Keyboard & Mouse port
Product Number-247 MNL-004 Page 19 of 84
Expandable to 64GB FB Dimm
System Components:
32GB DDR RAM (6) 146 GB Hot-Swap, removable SAS Hard
Drives with rugged metal carriers & receivers
Adaptec 5809 SATA/SAS Raid Controller Adaptec 29320ALP-R SCSI Controller
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Removable SCSI HP 920 LTO-3 Ultrium tape
drive
Low-profile DVD±RW(DL),-RAM,CD-RW drive
5.2.2 Additional specifications
Input voltage range: 115 Vrms nominal, 98 to
138 Vrms (-15%, +20%)
Input frequency range: 60 Hz nominal, 56.4 to
63.6 Hz (- 6%, + 6%)
Maximum operating power: 494.4 Watts Maximum operating current: 4.12 Amps Typical operating power: 410.4 Watts Typical operating current: 3.42 Amps Idle power: 367 Watts Idle current: 3.059 Amps AC Input Power connector: IEC 320 PFC: .97 typical Operating temp range: 0-50°C Non-operating temp range: -40-70°C Operating humidity: up to 90% non-condensing
5.2.3 SV-2002-X2 Server Highlights
The SV-2002-X2 is unlike any other Server that
is currently on the market. The SV-2002-X2 is ideal for use in deployable situations where the
product’s compact size, high density
computing, minimized size, weight, and power make for a highly portable, rugged and reliable system.
Product Number-247 MNL-004 Page 20 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5.2.4 SV-2002-X2 Server
Figure 5-2 SV-2002-X2 Server Components and Connectors (Front View)
5.3 Server Components
This section provides an overview of the most common components installed in TAG rugged Servers. Information is also provided on how to identify specific components within your Server. For detailed information on the specific components installed in your Server, refer the manufactures website.
5.3.1 Motherboard Model and Type
The version of an Intel Server motherboard can be determined by decoding the last three digits of the board part number.
For example: For the product C44686-703, the number following the "-" is as follows:
7 = Fabrication (FAB) Number 03 = Revision 3.
The board part number can be found on the motherboard. The board part number can also be determined by using Intel Server Management software.
Product Number-247 MNL-004 Page 21 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5.4 System Memory
The type and amount of system memory, or RAM (random access memory), on your Server depends on the motherboard installed and how it was configured.
5.4.1 Identifying System Memory
Refer to your Motherboard Model and Type. Once you have identified the motherboard, TAG technical support can assist you in determining the type and amount of system
memory in your system. See “Contacting
information on TAG on back page of this manual for information on how to contact Technical Support.
For information on replacing or upgrading your
system memory, refer to “Adding and
Replacing System Memory on page 62.”
5.4.1.1 Power Management
Modern motherboards provide Advanced Configuration and Power Management Interface (ACPI) settings such as wake-up, power button function and standby/suspend timers. These functions are configured in the CMOS Setup.
5.5 Identifying your I/O Connectors
Figure 5-3 shows a typical configuration of I/O connectors. Your configuration may vary depending on the motherboard installed in your Server; however, the color coding should remain consistent. I/O connectors are color­coded in compliance with PC 99 recommendations.
Product Number-247 MNL-004 Page 22 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Figure 5-3 I/O Connectors
5.6 Standard Server Components
The following sections provide information on the standard system components installed on TAG Servers
5.6.1 Floppy Drives
The floppy disk drive is a removable storage component and part of the storage subsystem. The drive style installed in your system is the Low Profile Internal Floppy Drive.
Figure 5-4 Low Profile Internal Floppy Drive
5.6.2 SCSI HP 920 LTO-3 Ultrium tape drive
Product Number-247 MNL-004 Page 23 of 84
The Ultrium 3 tape drive technology features a breakthrough in recording technology by
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
writing sixteen tracks simultaneously on a linear format of 704 tracks. The data is written in a serpentine pattern; the tape reverses direction after each set of eight tracks is written. This provides higher density recording, enabling customers to lower costs and increase efficiency by storing more data on a single tape in an industry standard format.
Figure 5-5.5 Internal Tape Drive
5.6.3 D/DVD Drive
The type of optical drive installed in your Server varies per configuration. Figure 5-6.
Figure 5-6 Slot-loading low-profile DVD±R (DL)/-RAM/CD-RW Drive
Product Number-247 MNL-004 Page 24 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5.6.4 Dual-redundant, auto-sensing power supply
Power for all the equipment in the system is a dual redundant, Hot-Swap AC input Power supply with an Input AC Voltage Range of 115 Vrms nominal, 98 to 138 Vrms (-15%, +20%).
Input Power Line Frequency
The system shall operate over the input power frequency range of 60 Hz nominal, 56.4 to 63.6 Hz (- 6%, + 6%).
Power Connector
The AC input power connector is IEC 320
WARNING
Power supplies contain dangerous voltages. Before attempting to work on any power supply always unplug the device and drain the power source by turning the Server on after the power supply has been disconnected. Failure to follow these instructions could result in serious injury due to electrical shock.
To satisfy reliability requirements, TAG Servers are designed with Hot-Swappable power supplies. If in the event of a power supply module failure or if the power source fails and only one module is receiving power, an audible alarm sounds. For procedures on how to Hot­Swap a power supply module, refer to the Procedures Section of this manual Replacing a Hot-Swap Hard Drive55.
Although most TAG power supplies for the 1U and 4U series Servers are similar in physical sizes, and physical characteristics, some Servers use smaller foot print power supplies. Figure 5-7 shows a typical Hot-Swap power supply.
Product Number-247 MNL-004 Page 25 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Figure 5-7 Hot-Swap Power Supply
NOTE: If your Server has two power input
receptacles, then the Server is equipped with a redundant Hot-Swap power supply.
Product Number-247 MNL-004 Page 26 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5.7 PCI I/O Expansion Cards
The following sections provide an overview of the PCI I/O components that may be included with your Server. For detailed information on these components, refer to the manufacturers' websites, or contact TAG Technical Support at
tech.support@tag.com. For more information,
See back page of this document.
5.7.1 Adaptec 5805 SAS/SATA RAID Controller
8 internal port, low profile, PCI-Express (PCIe) Unified Serial RAID controller with Intelligent Power Management delivers exceptional performance, advanced data protection, and maximum scalability for enterprise-class, high­density server applications
Product Number-247 MNL-004 Page 27 of 84
Figure 5-8 Adaptec 5805 RAID Card
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
5.7.2 Adaptec 29320 ALP-R SCSI Controller
The Adaptec SCSI Card 29320ALP-R is a low profile, 64-bit 133 MHz PCI-X, single-channel Ultra320 SCSI card with integrated HostRAID® RAID 0, 1 and 10 optimized for rack-mount servers. The Adaptec 29320ALP-R offers additional drivers for HostRAID and a new management tool. It provides worry-free data protection at the fastest SCSI speeds available up to 320 MByte/sec. The card has a 68-pin internal connector and a 68-pin VHDCI external connector for Ultra320 SCSI (LVD) hard disks drives.
NOTE: Serves as connection to Tape Drive
Figure 5-9 Adaptec 29320 ALP-R SCSI Controller
Product Number-247 MNL-004 Page 28 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Chapter 3
Procedures
Electronically distributed. Subject to user discretion when printed.
Product Number-247 MNL-004 Page 29 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
6 Procedures
The procedures within this Chapter contain relevant information to ensure your SV-2002­X2 Server maintains its maximum performance potential.
6.1 Server Startup
1. Check to make sure that all the cables are seated and connected correctly to the back of the unit such as keyboard, mouse, monitor VGA cable and both power cables.
2. Then Press the power switch ON to start the computer (power switch is located in the front of the unit)
3. Once the unit starts, System will go thru Power On self Test (POST) (no action is required at this time)
4. At windows dialog box press Ctrl, Alt, Delete at once to login
5. Type in the correct user name and password and then press enter to login
6. Once the operator is logged on to the unit they could use the computer as they wish.
NOTE: Assuming the Server is not connected to any network.
6.2 Server Shutdown
1. The operator needs save any data that is needed to be saved and then close application
2. Once all data is save and applications are closed, click on Start menu, select shutdown and then click OK to shutdown the computer.
6.3 Identifying Server Components Using Device Manager
The Device Manager is one of Windows' most useful diagnostic tools. It lets you see all of the devices attached to your computer, and which resources they are each using. To access the Device Manager do the following:
SV-2002-X2 Server
Product Number-247 MNL-004 Page 30 of 84
Version 1.4. 01/12/2010
Operations Manual
1. Click Start, point to Settings, and then click
Control Panel. (Figure 6-1).
Figure 6-1 Control Panel
2. Double-click the System icon. (Figure 6-2).
Product Number-247 MNL-004 Page 31 of 84
Figure 6-2 System Properties.
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
3. Click the Hardware tab, and then click the
Device Manager button. (Figure 6-3).
Figure 6-3 Device Manger
After opening Device Manager, you will see a list of all the devices Windows detected on your system. The Device Manager display is recreated each time the computer is started, or whenever a dynamic change to the computer configuration occurs, such as addition of a new device while the system is running.
NOTE: To include hidden devices, on the View menu, click Show hidden devices. A check mark next to Show hidden devices indicates hidden devices are showing. Click it again to clear the check mark. Hidden devices include non-PnP devices and devices that have been physically removed from the computer but have not had their drivers uninstalled.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 32 of 84
Version 1.4. 01/12/2010
Operations Manual
The devices shown represent the computer's current hardware configuration information. Any non-functioning devices are displayed with an exclamation point, indicating that a problem exists with the device; disabled devices are displayed with a small red "x" over the icon.
You can use Device Manager to enable or disable devices, troubleshoot devices, update drivers, use driver rollback, and change resources such as interrupt requests (IRQs) assigned to devices.
6.4 Working with Device Properties
To display a device's properties do the following:
1. Access the Device Manager as described in steps 1 through 3 (Figure 6-4).
Product Number-247 MNL-004 Page 33 of 84
Figure 6-4 Device Manager
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
2. In the Device manager dialog box (Figure 6-
5).double-click the device, or select the device and then click the Properties toolbar button
Figure 6-5 Properties Dialog Box
In the device's Properties dialog box, there might be several tabs. You can view the status and configuration information, as well as the device manufacturer, device type, and location in the upper portion of the General tab.
The Device status box in the middle of the General tab displays the status of the device, including any errors. If the device has any problems, the Device Status box briefly describes the problem, and usually describes the appropriate course of action to correct the problem.
3. Click Troubleshoot... to use the built-in mechanisms for detecting the nature of the problem.
Other tabs include the Driver tab, which displays the details of the driver being used.
Product Number-247 MNL-004 Page 34 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
This tab also lets you update or uninstall the driver. The Resources tab displays the hardware resources being used. This tab allows you to see and resolve any conflicts caused by non-PnP devices. Along with these tabs, some devices have additional advanced settings or tabs for device-specific settings.
6.5 Installing and Removing Hardware in Windows
Plug and Play (PnP) is a standard that makes installing new hardware devices easier. Prior to PnP, installing new hardware meant finding and installing peripheral drivers and making sure the new device didn't conflict with another device. Theoretically, if you have a computer designed for PnP and are using a PnP operating system (like Windows), installing a printer, sound card, modem, or other peripheral is a simple matter of plugging in the device.
6.5.1 Using the Add New Hardware Wizard
It's not always quite this simple. Assuming you are using a PnP computer, when you attach a PnP device, you may see a message indicating that Windows has recognized the new device­either immediately or the next time you start up your system. If Windows needs a driver that is not currently installed, you may at that point be asked to insert a disk or the Windows CD­ROM. If you don't see a message but the device appears to be working, you can assume that everything is fine.
If the device is not working properly, try using the Add New Hardware Wizard. To run this wizard, do the following:
Product Number-247 MNL-004 Page 35 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
1. From the Start menu, point to Settings and then click Control Panel. (Figure 6-6).
Figure 6-6 Control Panel
2. Double-click the Add Hardware icon. (Figure 6-7).
Product Number-247 MNL-004 Page 36 of 84
Figure 6-7 Add hardware Wizard
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
6.6 Installing Legacy Peripherals
When you install what Microsoft calls a legacy peripheral, you will need to use the Add
Hardware Wizard, as described “Error! Reference source not found.” on page
XXXX, to let Windows know about the new device.
NOTE: The term legacy refers to anything that's no longer on the cutting edge.
6.6.1 Removing Legacy Peripherals
When removing a legacy peripheral from your system, you need to let Windows know that the device is gone. This enables Windows to reuse the resources (places in memory and internal communications channels) that it previously allocated to that device.
To tell Windows that you have removed a legacy device, perform the following steps:
1. From the Start menu, point to Settings and then click Control Panel. (Figure 6-8).
Figure 6-8 Control Panel
Product Number-247 MNL-004 Page 37 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
2. Double-click the System icon. (Figure 6-9).
Figure 6-9 System Properties
3. Click the Hardware tab.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 38 of 84
Version 1.4. 01/12/2010
Operations Manual
4. Click the Device Manager button. (Figure 6-
10).
Figure 6-10 Device Manger
5. Click the name of the item you have removed from your system. If you don't see the item, look for a category heading that describes the type of device you removed, and then click the plus sign to its left to display a list of items in that category.
6. From the Action menu, click Uninstall.
7. Click OK.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 39 of 84
Version 1.4. 01/12/2010
Operations Manual
6.7 TAG Approved BIOS
The BIOS (basic input/output system) is the program stored on the CMOS that the Server's microprocessor uses to get the system started after you turn it on. The BIOS also manages data flow between the computer's operating system and attached devices such as the hard disk, video adapter, keyboard, and mouse.
CAUTION: The BIOS installed on your
Server was loaded and tested with all the devices initially installed in your system. If you desire to have the BIOS updated, consult TAG technical support in advance as updates to your approved BIOS may cause your system to become unstable or inoperable.
6.7.1 Common BIOS Settings
Printer Parallel Port-Uni., Bi-directional, Disable, Enable, ECP, EPP
6.7.1.1 Printer Parallel Port Uni. Bi-Directional, Disable, Enable, ECP, EPP.
Settings in the CMOS enable you to configure a parallel port to use Enhanced Parallel Port (EPP) or Enhanced Parallel Port (ECP). ECP. EPP and ECP are bi-directional standards, operate in 8-bit, and allow data transfer speed of approximately 2 MB/s. Some of the main differences are that ECP supports Direct Memory Access (DMA) and data compression, which enables higher transfer rates.
It is also possible to completely disable the parallel port in the BIOS. Most BIOS' allow you to set the DMA channel, when the port mode is set to ECP.
Product Number-247 MNL-004 Page 40 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
6.7.1.2 Com / Serial Port
Most personal computers have two serial ports. In the BIOS you can assign COM1/COM2/COM3/COM4 to serial port 1 or
2. Most BIOS' also allow you to set the I/O and
IRQ but this is mostly done automatically.
6.7.1.3 Floppy Drives
The floppy drive(s) can be enabled or disabled in the BIOS. The BIOS also allows you to choose the capacity of the media.
360 KB 5.25-inch 1.2 MB 5.25-inch 720 KB 3.5-inch 1.44 MB 3.5-inch 2.88 MB 3.5-inch
Some BIOS' allow you to swap A: and B: and disable seeking a floppy disk for a boot sector during startup.
6.7.1.4 Hard Drives
Most modern BIOS' allow automatic detection of disk parameters. The settings can be individually configured for the primary master and slave device and the secondary master and slave device. The following are some of the primary settings that apply to hard drives as well as CD/DVD-ROM drives, tape backup drive, etc.
Common disk types are:
User-defined Cylinders, Heads, Sectors (CHS)
values
Auto-automatically detects hard disks
parameters at every startup
1-46-predefined combinations of CHS values
Product Number-247 MNL-004 Page 41 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
CDROM-used for AT Attachment Packet
Interface (ATAPI) CD-ROM drives
ARMD-used for ATAPI ZIP and LS 120 drives DVDROM
Size - Determines the capacity of the drive CHS
values:
Number of Cylinders Number of Heads Number of Sectors LBA (Large Block Addressing)-technology to
overcome the 528 MB limit
6.7.1.5 Boot Sector Virus
A common setting related to hard drives. When enabled, the BIOS issues a warning message/beep if an attempt is made to write to the boot sector or partition table of a hard disk.
6.7.1.6 Memory
Parity adds an extra bit (odd or even) to the 8­bit data-string to ensure data integrity in memory modules. Its successor, ECC, provides improved data integrity by adding information about individual bits.
6.7.1.7 Boot Sequence
This setting is used to control the order that the BIOS uses during the boot process to look for a boot device from which to load the operating system. For example:
CD Floppy Hard Disk
6.7.1.8 Date and Time
The Date and Time is set in the BIOS, stored in CMOS, and maintained by CMOS battery.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 42 of 84
Version 1.4. 01/12/2010
Operations Manual
6.7.1.9 Passwords
In most cases a user (startup) password and a supervisor (setup) password can be set in the CMOS. When a Setup password is required, the computer will prompt for it when you try to access the BIOS setup. When a Startup password is configured, the computer will prompt for it at every startup.
The CMOS password can be reset by shortening the "CMOS restore to factory defaults jumper" or by temporarily removing the CMOS battery.
6.7.1.10 Plug and Play BIOS
Today's BIOS' are Plug_and_play (PnP)­aware. This means they are able to automatically assign resources such as IRQ and DMA to PnP devices.
Information about PnP devices is stored in a separate area of non-volatile CMOS memory, called the Extended System Configuration Database (ESCD). Both the PnP BIOS and the operating system can access this area and communicate with each other about resource settings assigned to PnP devices as well as non-PnP devices. For example, when a fixed interrupt request (IRQ) is manually assigned to a particular device using Device Manager, Windows will write this information to the ESCD on shutdown thereby preventing the BIOS from assigning the same IRQ to a PnP device at startup.
You can also reserve IRQs for non-PnP devices in the CMOS setup, this will prevent the BIOS from assigning these reserved resources to PnP devices, a common example is a legacy sound card that needs IRQ 5.
Product Number-247 MNL-004 Page 43 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
6.8 Bios Configuration for SV-2002-X2
1. Press F2 to access the Main BIOS Page. On the Main Page, Select Quiet Boot then select
Enable and press Enter. (Figure 6-11).
Product Number-247 MNL-004 Page 44 of 84
Figure 6-11 Quiet Boot
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
2. Back at the Main Screen press F9. On the drop down menu select and press YES. (Figure 6-12).
Figure 6-12 Load Optimized Defaults
SV-2002-X2 Server
Product Number-247 MNL-004 Page 45 of 84
Version 1.4. 01/12/2010
Operations Manual
3. In the Advanced Menu scroll down and select
Enhanced Intel press Enter. (Figure 6-13).
Figure 6-13 Enhanced Intel
SV-2002-X2 Server
Product Number-247 MNL-004 Page 46 of 84
Version 1.4. 01/12/2010
Operations Manual
4. In the Enhanced Intel drop down menu select
Disable and press Enter.. (Figure 6-14).
Figure 6-14 Enhanced Intel, Disable
SV-2002-X2 Server
Product Number-247 MNL-004 Page 47 of 84
Version 1.4. 01/12/2010
Operations Manual
5. In Processor Confirmation screen select Deep C-state Support and press Enter. (Figure 6-15).
Figure 6-15 Processor Confirmation Screen
SV-2002-X2 Server
Product Number-247 MNL-004 Page 48 of 84
Version 1.4. 01/12/2010
Operations Manual
6. In Deep C-state Support screen select Disable and press Enter. (Figure 6-16).
Figure 6-16 Deep C-state Support Screen
SV-2002-X2 Server
Product Number-247 MNL-004 Page 49 of 84
Version 1.4. 01/12/2010
Operations Manual
7. In Processor Confirmation screen select
Intel Virtualization Technology and press Enter. (Figure 6-17).
Figure 6-17 USB Configuration
SV-2002-X2 Server
Product Number-247 MNL-004 Page 50 of 84
Version 1.4. 01/12/2010
Operations Manual
8. In Intel Virtualization Technology drop down menu select Enabled and press Enter. (Figure 6-18).
Figure 6-18 Intel Virtualization Technology
SV-2002-X2 Server
Product Number-247 MNL-004 Page 51 of 84
Version 1.4. 01/12/2010
Operations Manual
9. In Processor Confirmation screen drop down menu Save and Reset select Yes and press
F10. (Figure 6-19)
Figure 6-19 Save and Reset
SV-2002-X2 Server
Product Number-247 MNL-004 Page 52 of 84
Version 1.4. 01/12/2010
Operations Manual
6.9 Upgrading Memory and Replacing Hot-Swap and LRU Components
6.9.1 Preventing Static Electricity
This section provides procedures for replacing all Hot-Swappable and LRU components, including procedures for replacing or adding system memory.
The components inside your computer are extremely sensitive to static electricity, also known as electrostatic discharge (ESD). ESD can permanently damage electrostatic discharge­sensitive components in your Server.
To prevent ESD damage, follow these guidelines before opening the Server case:
1. Turn off the Server and unplug the power cord before opening the case.
2. Wear a grounding wrist strap and attach it to a bare metal part of the Server, workbench, or other grounded connection.
Product Number-247 MNL-004 Page 53 of 84
Figure 6-20 Grounding Wrist Strap
3. Do not insert any object into the vent holes on the case or the power supply. Touch a bare metal surface on the back of the computer, a bare metal surface on your workbench, or other grounded object before handing DIMMs or other components.
Before working with computer components, follow these guidelines:
Avoid static-causing surfaces such as carpeted
floors, plastic, and packing foam.
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Remove components from their antistatic bags
only when you are ready to use them. Do not lay components on the outside of antistatic bags because only the inside of the bags provide electrostatic protection. Always hold memory modules and components by their edges or their metal mounting brackets.
Avoid touching the edge connectors and
components on the cards. Never slide memory modules or components over any surface.
6.10 Replacing a Hot-Swap Power Supply Module
Your TAG Server was designed with the ability to Hot-Swap a power supply module without disconnecting system power. Refer to Figure 4­12 and the steps that follow to Hot-Swap a power supply module.
NOTE: If you need to remove both modules, you must shutdown the system, unplug the power source from the unit and drain the systems onboard battery by pressing the on/off switch and holding it in place for approximately 10 seconds to drain any charge that might be retained by the systems motherboard.
1. Obtain certified replacement module from TAG. For more information on contact information see document back page.
2. Depending on the series of your Server, either a retention bracket or filtering cover that is secured with thumb screws will need to be removed first.
NOTE: In some cases a screw driver (Philips head) might be required to remove a retention bar that is screwed into the power supply.
3. Loosen the thumb screws on the desired module to be replaced.
4. Depress the module safety latch and gently pull the handle as shown in Figure 5-42
SV-2002-X2 Server
Product Number-247 MNL-004 Page 54 of 84
Version 1.4. 01/12/2010
Operations Manual
Figure 6-21 Hot-Swap of 2U Server Power Supply Module
5. Slide the replacement module into the power supply.
6. Press firmly and evenly on the power module until you feel the module seat in the back of the power supply
6.11 Replacing a Hot-Swap Hard Drive
The system's hard drive Hot-Swap feature enables you to remove a hard drive without shutting down the operating system or turning off the system power. The way in which you remove a hard drive depends on the application you are using and whether you are replacing a drive, adding a new one, or removing a drive permanently.
When you remove a drive using the Hot-Swap operation, you need to stop the hard drive and take it offline to remove the logical software links to the hard drive, and to reconfigure the file system so that it will now ignore the removed drive. You might also have to reconfigure your application software to operate without the removed drive. Therefore it is strongly recommended that you contact TAG Technical Support at tech.support@tag.com before attempting to Hot-Swap a hard drive. For more information on contact information see document back page.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 55 of 84
Version 1.4. 01/12/2010
Operations Manual
6.11.1 146GB SAS Hard Drive
Figure 6-22 146GB SAS HDD (Removed from HD Carrier)
6.12 Removing the Server Cover
CAUTION
The location of the mounting screws securing the Server cover varies per Server model. To remove the cover, use a Phillips screwdriver to remove all screws from the sides and top of the cover.
NOTE: It is important to make note of the location from which screws are removed since different screw lengths may be used to secure the cover.
It is not safe to operate TAG Servers without the cover in place. Failure to take this precaution may result in personal injury and system damage.
Product Number-247 MNL-004 Page 56 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
6.13 Adding or Replacing System Memory
This section lists the procedures for adding or replacing system memory.
WARNING
Ensure that the system is powered-down and all power sources have been disconnected from the Server prior to removing or replacing system memory. Failure to do so could result in serious injury from electrical shock.
CAUTION
Printed circuit boards and hard drives contain electronic components that are extremely sensitive to static electricity. Ordinary amounts of static from your clothes or the work environment can destroy components. Do not touch the components or any metal parts without taking
proper antistatic precautions.
AG's rugged Servers combine Intel® Xeon® technology with state-of-the-art mechanical, thermal and electrical engineering to create customized systems that perform above and beyond end user or program specifications. Our rugged Servers are designed to meet and exceed many MIL-STD requirements to ensure survivability in the field.
SV-2002-X2 Server
Product Number-247 MNL-004 Page 57 of 84
Version 1.4. 01/12/2010
Operations Manual
6.13.1 Install system memory.
Unlatch both DIMM socket levers, as shown in Figure 4-14.
Figure 6-23 DIMM Module Bank
1. Note the location of the alignment notch.
2. Align the notches on the new module with the notches on the memory and press it firmly into the bank.
NOTE: The tabs on the sides of the memory module should secure the DIMM automatically. When the DIMM locks into place, you will hear a click.
6.14 Replacing the CMOS Battery
This section lists the procedures for replacing the motherboard CMOS Battery.
1. Boot up the Server and enter set-up mode.
2. Record all the settings from the various BIOS menus.
3. Power off the Server.
4. Remove the lid from the Server.
5. Locate the CMOS battery on the motherboard (ref. Figure , Notation “H”).
6. Remove the old battery.
7. Replace it with the new battery.
8. Replace the lid and power on the Server.
9. Enter the set-up mode of the Server.
Product Number-247 MNL-004 Page 58 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
10. Re-enter any applicable settings through the various BIOS menus.
Product Number-247 MNL-004 Page 59 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
6.15 Ultrium 920 Tape Drive
The Ultrium 920 delivers a compressed storage capacity of 800GB per data cartridge and a compressed data transfer rate of 432GB per hour. The Ultrium 920 Tape Drive is fully read and write.
6.15.1 Remove Tape Drive
1. Turn off all power to the server and remove power cables from their power source.
2. Unscrew the four (4) thumb screws holding the Tape Drive into place.
3. Pull the Tape Drive body slightly toward the front of the server and then tilt upward.
Note: Pulling slightly forward will take it from under the Server top cover.
4. When Tape drive body is in the upright position remove all cable connections. Then remove Tape Drive.
5. Pull the top cover off the tape drive body.
6. Remove the four (4) retaining screws that are holding the bottom cover on to the Tape Drive.
6.15.2 Install Tape Drive
7. Install the bottom cover and its four (4) retaining screws.
Product Number-247 MNL-004 Page 60 of 84
8. Replace the Tape Drive top cover.
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
9. Slide the cover end of the new Tape Drive under the servers top cover and tighten all four
94) thumb screws.
10. Restore all power cables to their power source. .Power up the server and test the new Tape Drive.
Product Number-247 MNL-004 Page 61 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Chapter 4
RAID.
Electronically distributed. Subject to user discretion when printed.
Product Number-247 MNL-004 Page 62 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
7 RAID
RAID is an acronym for Redundant Array of Inexpensive (or Independent) Disks. This section provides a high-level overview that defines RAID, the advantages and disadvantages of various RAID levels, and guidelines to observe when implementing RAID.
7.1 RAID Defined
RAID is a way of storing data on two or more physical disks for the purpose of redundancy, improved performance, or both. The combined physical disks make up what is called an array. This array appears on the host system as one disk. For example, if you have physical disk 1 and physical disk 2, those two disks appear to the host system as one disk.
RAID consists of different levels, which determine how the data is placed in the array. Each RAID level has specific data protection and system performance characteristics. The following are commonly used SCSI RAID levels:
1. RAID Level 0: Striping, good performance, no redundancy
2. RAID Level 1: Mirroring, one-to-one redundancy
3. RAID Level 5: Striping with parity striped across all drives; offers performance and redundancy
4. RAID Level 10: Mirroring and striping; best redundancy and best performance
5. RAID Level 50: Parity striped across all drives in a mirrored set; redundancy and performance
You can manage RAID arrays with a RAID controller (hardware RAID) or with software alone (software RAID).
SV-2002-X2 Server
Product Number-247 MNL-004 Page 63 of 84
Version 1.4. 01/12/2010
Operations Manual
7.1.1 RAID Level 5
RAID Level 5 maps the data across the drives and stores parity information for each data stripe on different drives in the array. The parity data, labeled P in Figure , is distributed. This lessens the data congestion that occurs if all of the parity data is written to one drive. A RAID 5 array can preserve data if one drive fails. However, if two drives fail, all data in the array is lost.
Product Number-247 MNL-004 Page 64 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
7.2 Create a RAID 5 Array On Adaptec 5805
1. Power up your computer. When prompted, press Ctrl A to enter the ARC Utility.
NOTE: During boot up, if your system has insufficient memory the following message will display. “Adaptec RAID Configuration
Utility will load after, system initialization. Please wait. Or press <Enter> Key to attempt loading the utility forcibly
[Generally, not recommended]”
2. Select Array Configuration Utility from the menu and press Enter. (Figure 7-1).
Product Number-247 MNL-004 Page 65 of 84
Figure 7-1 Array Configuration
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
3. Select Initialize Drives, and then press
Enter. (Figure 7-2).
Figure 7-2 Initialize Drives
4. Select Initialize all Hard Drives for the array, press Insert for each selected disk drive, then press Enter. (Figure 7-3).
Product Number-247 MNL-004 Page 66 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Figure 7-3 Select Drives
5. During initialization, all data is deleted from the disk. Before continuing back up any data you want to keep. (Figure 7-4).
Figure 7-4 Initialization Warning
6. Press YES to continue. (Figure 7-5).
Product Number-247 MNL-004 Page 67 of 84
Figure 7-5 Initialized
7. Press any key to continue
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
Product Number-247 MNL-004 Page 68 of 84
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
8. On the ACU screen select Create Array from the Main Menu and press Enter. (Figure 7-6).
Figure 7-6 Create Array
SV-2002-X2 Server
Product Number-247 MNL-004 Page 69 of 84
Version 1.4. 01/12/2010
Operations Manual
9. Select the first Five (5) Hard Drives that were just initialized, press Insert for each selected disk drive, then press Enter. (Figure 7-7).
Figure 7-7 Select Drives
SV-2002-X2 Server
Product Number-247 MNL-004 Page 70 of 84
Version 1.4. 01/12/2010
Operations Manual
10. In Array Type select RAID 5 press Enter. (Figure 7-8).
Product Number-247 MNL-004 Page 71 of 84
Figure 7-8 RAID 5
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
11. In Array Label type a name and press
Enter. (Figure 7-9).
Figure 7-9 Array Label
SV-2002-X2 Server
Product Number-247 MNL-004 Page 72 of 84
Version 1.4. 01/12/2010
Operations Manual
12. Array Size Press Enter, then press Enter again to use the default granularity of GB. (Figure 7-10).
Product Number-247 MNL-004 Page 73 of 84
Figure 7-10 Array Size
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
13. In Stripe Size scroll down and select (25 KB). (Figure 7.11).
Figure 7-11 Stripe Size
SV-2002-X2 Server
Product Number-247 MNL-004 Page 74 of 84
Version 1.4. 01/12/2010
Operations Manual
14. In Read Caching scroll down and select
Enable Max ID. (Figure 7-12).
Product Number-247 MNL-004 Page 75 of 84
Figure 7-12 Read Caching
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
15. In Cache Warning press Enter. (Figure 7-
13).
Product Number-247 MNL-004 Page 76 of 84
Figure 7-13 Cache Functionality
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
16. In Write Caching select Disable and press
Enter. (Figure 7-14).
Product Number-247 MNL-004 Page 77 of 84
Figure 7-14 Write Caching
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
17. In Create RAID select (Build/Verify) and press Enter. (Figure 7-15).
Product Number-247 MNL-004 Page 78 of 84
Figure 7-15 Build/Verify
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
18. Press Enter to continue. (Figure 7-16).
Product Number-247 MNL-004 Page 79 of 84
Figure 7-16 Press Enter
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
19. When a cache warning message displays, type Y. (Figure 7-18).
Product Number-247 MNL-004 Page 80 of 84
Figure 7-17 Cache Warning
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
20. Check that a Global Hotspare is available. (Figure 7.18).
NOTE: Ensure you have previously only selected five (5) of the available six (6) drives this will ensure you have a Hot Spare.
21. After viewing the response press any key to return to the ACU Menu.
Product Number-247 MNL-004 Page 81 of 84
Figure 7-18 Hot Spare Check
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
22. Press Escape. The Exit utility window will appear. Select YES and press Enter. (Figure 7-19).
Product Number-247 MNL-004 Page 82 of 84
Figure 7-19 Exit Utility
23. Your Computer Restarts
SV-2002-X2 Server
Version 1.4. 01/12/2010
Operations Manual
7.3 About RAID Global and Hot Spares
A hot spare is a drive that is on standby in case another drive fails. Depending on how the array is configured, the drive is either picked up automatically and the array is rebuilt, or you manually select the drive (or insert a new drive in the same slot as the failed drive) and rebuild the array.
How the hot spare works depends on how the array is configured. When a drive fails, the array rebuilds automatically using the hot spare. This is assuming that automatic rebuild is enabled. If automatic rebuild is disabled, you must manually start the rebuild process.
During a rebuild you may notice degraded performance on the drives.
7.4 Global and Dedicated Hot Spares
A dedicated hot spare is assigned to one or more arrays, whereas a global hot spare can be used for any array that is on the same controller as the hot spare. Also, dedicated hot spares that reside in the same storage enclosure typically have better performance
than global hot spares.