Testing the ambient temperature
of the remote controller unit
TEMPSET
TEMPSET
TEMPSET
TEMPSET
TEMPSET
TEMP SET
A
A
A
A
A
A
C
C
C
C
C
C
Transmitter
Transmitting signals to the indoor unit,
the symbolwill appear on the top of
LCD.
1 HOUR TIMER button
Hi-power running button
Flap
Up-down adjustment
Sleep button
Press the button, the appliance
enter sleep mode.
A/C sensor button
Press the button of the remote
controller is liable to be afected by
the heater source such as electric
blanked, radiator or sun light,this
will use the sensor of indoor unit the
symbol will appear on the LCD.
1HOUR
1HOUR
1HOUR
1HOUR
1HOUR
1HOUR
1HR
FLAP
SLEEP
H.P.
A/C SENSOR
1
1
1
1
1
1
HOUR
HOUR
HOUR
HOUR
HOUR
HOUR
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
TEMP
ON
SET CANCEL
A
A
A
A
A
A
A
A
A
A
A
A
FAN
SPEED
ON/OFF
MODE
OFF
LCD
Displaying the running condition.
Fan speed selection button
On/Off button
Press the button to run,
press again to cease.
Temperature setting button
Press the button marked""or
"" to increase or decrease
the temperature.
Mode selection button
Autoheating
Fancooling
dehumidification
Timer on/off button
ACL
Setting the time of appliance on/off.
Set/cancel timer button
Set or cancel the time of appliance
on/off.
ACL
Reset button
Press the button after batteries are
loaded and indication appears on
LCD.
Sliding cover
(pull off the cover at THE BACK To expose the batteries.)
(Cover closed)
REMARK: :The remote controller transmits signal to indoor unit at 3 minutes intervals.If the indoor unit
has not received the signal for more than 10 minutes due to remote controller missing or other reason,
the sensor on indoor unit will be used for detecting indoor temperature automatically. Here ,ambient
temperature of remote controller is likely to slightly different from that detecting by the indoor unit ,
temperature will be ccompensated automatically. When the remote controller is missing or the batteries
are exhausted, please use the temporary switch.
2
1. PART NAMES AND FUNCTIONS
TGI-18H
INDOOR UNIT
Front panel
Air inlet
Horizontal vane
OUTDOOR UNIT
Air filter
Air fresh filter
Indoor coil sensor
Switch button
Power plugAir outletVertical vane
Display panel
Air inlet (rear and side)
Air outlet
Drainage hole (bottom)
Tube sand cable
Drainage hose
3
1. PART NAMES AND FUNCTIONS
Sensor
Testing the ambient temperature
of the remote controller unit
LCD
Displaying the running condition.
TGI-18H
REMOTE CONTROLLER
AUTO
T. SETTING
C
Transmitter
Transmitting signals to the indoor unit,
the symbolwill appear on the top of
LCD.
On/Off button
Press the button to run,
press again to cease.
1 HOUR TIMER button
Hi-power running button
Flap
Up-down adjustment
Timer on/off button
Setting the time of appliance on/off.
Set/cancel timer button
Set or cancel the time of appliance
on/off.
A/C sensor button
Press the button of the remote
controller is liable to be afected by
the heater source such as electric
blanked, radiator or sun light,this will
use the sensor of indoor unit the
symbol will appear on the LCD.
1ÑÁûÐ
1HOUR
HOUR
AUTO
ON
AUTO
OFF
1 HR
ON / OFF
HIGH
POWER
FLAPMODE
OFFON
FAN SPEED
CANCELSET
BATTERY
TEMP.
SLEEP
ACLA/C SENSOR
Temperature setting button
Press the button marked""or
"" to increase or decrease
the temperature.
Mode selection button
Autoheating
Fancooling
dehumidification
Fan speed selection button
Sleep button
Press the button, the appliance
enter sleep mode.
Reset button
Press the button after batteries are
loaded and indication appears on
LCD.
T. SETTING
A
Sliding cover
C
1ÑÁûÐ
1HOUR
HOUR
A
ON
A
OFF
1 HR
ON / OFF
TEMP.
HIGH
POWER
Battery compartment
(Cover closed)
REMARK: :The remote controller transmits signal to indoor unit at 3 minutes intervals.If the indoor unit
has not received the signal for more than 10 minutes due to remote controller missing or other reason,
the sensor on indoor unit will be used for detecting indoor temperature automatically. Here ,ambient
temperature of remote controller is likely to slightly different from that detecting by the indoor unit ,
temperature will be ccompensated automatically. When the remote controller is missing or the batteries
are exhausted, please use the temporary switch.
1.2 The display screen consists of 4 LEDs,indicating : power , time set ,
operation and high power respectively.
1.3 Power indicator. When the airconditioner runs, the power indicator lamplights
up ; Compressor operation indicator. When the compressor runs , the
operation indicator lights up.
1.4 Timer indicator . When the timer function works , the timer indicator lamp
lights up.
1.5 High power indicator. When the airconditioner works in high efficient mode ,
the high efficient indicator lemp lights up.
2. Temporrary switch.
2.1 Press the temporary switch to start the unit, and press it once again to stop
the unit ; the control unit makes a judge according to the room temperature
to select the corresponding run mode .Once a run mode is sellected , it will
not be changed unless the unit is cut off and the power is on again.
A. When the room temperature > 26ºC , the unit starts in the cooling mode ; the
indoor controlled temperature is set at 26ºC , and the indoor fan speed is set
to automatic mode.
B. When the room temperature < 23ºC the unit starts in the heating mode ; the
indoor controlled temperature is set at 23ºC , and the indoor fan speed is set
to the automatic mode.
C. When 23ºC ≤ the room temperature ≤ 26ºC , the air blwing mode starts , and
the indoor fan speed is set to automatic.
2.2 When the airconditioner is powered on , hold down the temporary
Switch for 5 sec’ or longer , the control unit starts the test operation , when
the system is forced to run in the cooling mode regardless of the room
temperature.
2.3 Hold down the temporary switch and than turn the airconditioner , the buzzer
on the indoor unit rings two times , and the unit enters in the self – teststatus
.
2.4 If a signal has been received from the remote controller during the temporary
run , the system will operate according to the commands of the remote signal
.
30
9. CONTROL MODE
3. Automatic mode.
3.1 When the remote controller is set to start the unit in the automatic mode , the
airconditioner judges according to the differences between the room
temperature and temperature setting and selects a run mode.
Indoor temperature ≥ temperature setting , the unit runs in the cooling mode.
Indoor temperature < temperature setting , the unit runs in the heating mode.
3.2 The run mode is determined when the unit gets started at the first time. Once
the mode is selected , it will not change within 30 min’.
3.3 If the difference between the room temperature and temperature setting is
above 3ºC , the run mode can be changed immediately.
3.4 When the unit is turned off and restarted with the remote controller , these
conditions remain valid.
3.5 When powered off and powered on again , the airconditioner will reselect run
mode.
3.6 The indoor and outdoor and compressor control in the automatic mode are
same as that in the heating and cooling mode.
3.7 After being set to the cooling only type in EE, the heating mode doesn’t work.
4. Cooling mode
4.1 In the cooling mode , the temperature setting is selected by using the remote
controller from 16 - 30ºC
4.2 When powered on for the first time , the compressor can be started
immediately.After running off , the compressor must not be restarted until at
least 3 minutes later.
4.3 After turning on , the compressor must run for at least 5 minutes.
Indoor fan speed.
Fan speed TGI 07H-09H TGI 12H TGI 18H
Turbo 1,950 1,950 1,300
High 1,850 1,850 1,250
Low 1,700 1,700 1,050
Mute 1,600 1,600 900
Ultra low 1,500 1,500 850
31
9. CONTROL MODE
Automatic
T
setting-Troom
0ºC
1ºC
2ºC
3ºC
4ºC
F
an speed
Mute
Low
Low
Low
Low
T
setting-Troom
0ºC
1ºC
2ºC
3ºC
4ºC
F
an speed
Mute
Low
Low
Low
Low
≥5ºC High
≥5ºC High
Outdoor fan speed
Single speed motor starts or stop as soon as the compressor starts or stops.
4.4 The 4 way valve is interrupted.
4.5 Anti freeze routine : When the indoor coil temperature ≤ -1ºC and maintaining
for 5 minutes , both the compressor and outdoor fan are interrupted.The
resumption condition is that the indoor coil temperature ≥7ºC.
5. Dehumidification (Dry) mode
5.1 In the dry mode , the temperature setting is sellected by using the remote
controller . The temperature control ranges from 16 - 30ºC.The control unit
selects a run mode according to the temperature difference between the
room tempeature and temperature setting.
5.2 When the room temperature is above 2ºC higher than the temperature
setting , the system runs in the cooling mode.
5.3 When the difference between the room temperature and temperature setting
is equel to or lower than 2ºC , the system starts in Dry mode . In the Dry
mode , both the compressor and outdoor fan operate in the cycle of 10 min’
run and 6 min’ stop.
5.4 When Dry mode is operated , the outdoor fan motor starts or stops as soon
as soon as the compressor starts or stops.
32
9. CONTROL MODE
6. Heating mode
6.1 In the heating mode , the temperature setting is determined with the remote
controller . The temperature control ranges from 16 - 30ºC.
6.2 When powered on for the first time , the compressor may be started
immediately. After turning off , the compressor must not be restarted until at
least 3 min’ later.
6.3 After turning on , the compressor must operate at least 5 min’.
6.4 When the airconditioner turns off , the compressor is interrupted ;the outdoor
4 way valve turns off after a 1 minute and 40 sec’ delay and the indoor fan
stops after a 40 sec’ delay to blow out the heat.
6.5 Cold air prevention . when the airconditioner turns on , the indoor unit does
not start immediately . When the heat exchanger temperature rises above
28ºC , the fan operates at the ultra low fan speed , and the flap is opened to
the first position; when the heat exchanger temperature ≥ 38ºC or runs for
over 4 minutes , the fan runs at a preset fan speed , and the fan is open to a
preset position. When the indoor heat exchanger temperature drops below
23ºC , the indoor fan motor stops.
6.6 When the unit is running , the indoor fan motor stops 40 seconds after the
compressor is interrupted because the room temperature has reached the
temperature setting . When the compressor is in operation again , the cold
air prevention function still works.
6.7 In the heating mode , the outdoor fan starts or stops as soon as the
compressor starts or stops unless the indoor heat exchanger overheat
protection starts.
6.8 After being set to cooling only type in EE the heating mode does not work .
6.9 The 4 way valve is activated.
6.10 Indoor heat exchanger overload protection : T
compressor is interrupted; T
resumption temperature for each of the control points is 50ºC.
Indoor fan speed
indoor coil
≥ 55ºC , outdoor fan motor stops. The
indoor coil
≥ 60ºC , the
Fan speed TGI 07H-09H TGI 12H TGI 18H
Turbo 2,000 1,950 1,300
High 1,900 1,850 1,250
Low 1,700 1,700 1,050
Mute 1,600 1,600 900
Ultra low 1,500 1,500 850
33
9. CONTROL MODE
Automatic
T
setting-Troom
1ºC
2ºC
3ºC
4ºC
5ºC
≥6ºC
an speed
F
Low
Medum
Medum
Medum
High
High
T
setting-Troom
F
1ºC
2ºC
3ºC
4ºC
5ºC
≥6ºC
an speed
Low
Low
Medum
Medum
Medum
Medum
7. Defrosting mode
7.1 Frost is removed by reverse of the 4 way valve.
7.2 Conditions for entering in the defrosting mode :
After the unit gets started (in the heating mode) or every time the
defrosting run ends , calculated from the time when the heating run
continues for 12 min’ , the drop in the coil temperature amount to at least “
6ºC ” and the coil temperature reaches below 40ºC.
In the heating mode , the difference between the coil temperature and
indoor ambient temperature (inlet air temperature) is less than 10ºC , and
maintains for at least 5 min’
The coil temperature < 40ºC and maintaines for at least 90 min’
The airconditioner will enter defrosting as long as any of the three conditions is
satisfied .
Defrost action
Both the compressor and the outdoor fan motor are interrupted.
50 seconds later the 4 way valve turns off (cooling mode).
5 seconds later , the compressor get started.
Defrosting starts . the longest defrosting time is 13 minutes.
3 minutes after defrosting starts the value of the compressor current is read .
If the compressor current is above 1.2A higher than the current at the end of
the first 3 minutes , the system quites defrosting 1 minute later.
30 seconds later the , the 4 way valve returnes on.
5 seconds later compressor starts.
3 seconds later , outdoor fan motor starts.
Defrost ends.
34
9. CONTROL MODE
8. Fan mode
When select the fan mode , only both the indoor fan and flap operate in a preset
mode . If the fan speed is set to automstic , the fan runs at the low speed.
9. Flap control
9.1 Press the up and down flap button , the flaps position is switched over
between the 8 statuses , i.e automatic flap , flap orientation where the flap
plate opens to 6 positions 1,2,3,4,5,6 from down to up , and flap swing .
9.2 Automatic flap : In heating mode , the flap swings between position 1 and
position 4 . In Cooling or Dry mode , the flap swings between position 3 and
position 6 . In Fan mode the flap is located at top position 5.
9.3 Flap orientation : The flap is set at a certain position by using the remote
controller.
9.4 Flap swing : The flap swings between position 1 and position 6.
9.5 The default status is the automatic flap.
9.6 When powered on and off for the first time , the flap plate turns to the
maximum angle to ensure that the flap is closed ; When the unit starts , the
flap plate moves to the maximum angle , and returnes to the preset position
after the flap is completely closed.
10. Sense here function
10.1 The indoor control unit has two thermal for detecting the room
temperatures , one is installed in the remote controller , and the other at the
air intake of the indoor unit . The default air outlet settings is subject to the
remote controller’s detection .The remote controller detects the room
temperature every 20 seconds , and automatically transmits the signal at 3
minutes intervals or when it has detected a change in the room temperature .
If the indoor control unit has not received a remote signal for more than 10
minutes , the control function will be automatically switched over to the
temperature sensor at the air intake .
10.2 Neither turning on nor turning off operation will cancel the interface
communicatin function.
10.3 In default , the airconditioner is set to start the interface communication
function.
35
9. CONTROL MODE
11. Timer function
11.1 Timer on : When set to start in the set time with the remote controller ,
the air conditioner enters in the timer on status.When the set time is up the
air conditioner turns on and operates according to the preset conditions after
receiving the signal from the remote controller . If the air conditioner has not
received the signal of the remote controller when the set time is up , it will
automatically start and operate according to the preset conditions.
11.2 Timer off : When set to stop in the set time with the remote controller ,
the air conditioner enters the timer off status.When the set time is up , the air
conditioner turns off after receiving the signal from the remote controller. If
the air conditioner has not received the signal of the remote controller when
the set time is up , it will turn off automatically.
11.3 Neither turning on nor turning off operation will cancel the timer
function.
12. Sleep function
12.1 In heating or cooling mode press the sleep button on the remote
controller to start or cancel the sleep function in sequence.
12.2 In heating mode 1 hour after the sleep mode starts , the temperature
setting will decrease by 3ºC. After another 2 hours the temperature decrease
by 4ºC further.The air conditioner will continue to run for further 5 hours and
than stops automatically.
12.3 In cooling mode , 1 hour after the sleep mode starts , the setting will
rise by 1ºC. The air conditioner will continue to run for further 7 hours and
than automatically stops.
12.4 In default the preset status is to cancel the sleep function.Turning off
the air conditioner will also cancel the sleep function.
13. High power function
In the high power run mode , the indoor fan speed is switched over to the
high power indicator lemp on the display panel lights up.
When the control unit generates the protective action , press the sensor
switch – over button , the trouble code will be displayed on the LCD screen
on the indoor unit to help debug and repair : When the air conditioner gets
in trouble and brings about trouble codes are tabulated below
( ☻ means led lights up and stays on ; ☺ means led blinks ) :
Trouble description
Room temperature sensor
abnormal.
Indoor coil temperature
sensor abnormal.
Indoor coil frozen 3
Error
code
1
2
High
power
LED DISPLAY
Operatio Timer Power
☺
☺
☺ ☺
Indoor coil overheated 4
Power interruption 6
Compressor over current 7
Fan motor locked 8
Trouble with the Eeprom 13
☺☺☺☺☺
☺ ☺
☺ ☺ ☺
1. Compressor over current protection
Depends on the over current protection value of the overlpad
protection device in a model.
2. Indoor coil overheat protection.
Refer to the heating mode.
3. Indoor coil anti – freeze protection.
Refer to the cooling mode.
4. Time delay start protection : After turning off , the compressor will
not be restarted until 3 minutes later to protect the compressor.
5. Faulty indoor fan motor : If the indoor micro processor , according to
the position signal of the indoor fan motor rotor , judges that the
motor is not operating , locked or vibrating abnormally , it will cut off
the indoor fan motor’s drive signal , and restarts the motor 3 minutes
later ; If the fault accurs 4 times within 30 minutes , the air conditioner
turns off and displays the error code . The unit will not restart until
powered on.
38
12.DISASSEMBLYINSTRUCTIONS
TGI-07H ,TGI-09H ,TGI-12H
1 Remove the grille
1. Open the screw cover of the grille.
2. Take out the screws of the grille.
3. Hold both sides of the grille and drag it
upwards by moving it around the outlet grille.
Front Panel
Screws
2 Remove the electrical control box
1. Remove the cover of the electrical control box
2. Take the indoor coil sensor from the sensor bracket.
3. Remove the switching board.
4. Take out the screws of the terminal board and
remove the terminal board.
5. Disconnect the connectors of the printed circuit board.
6. Remove and check-up the printed circuit board.
7. Disconnect all the connectors of the electrical control box.
8. Take out the screws of the electrical control box and
remove the electrical control box.