TGL/DGL Installation Instructions
General
● These instructions are intended as general guidelines. The air conditioner must be installed by trained and authorized personnel.
● Use the following size copper tubing for connecting the outdoor and indoor units:
Models TGL/DGL 9, 11 - 3/8" and 1/4". Models TGL/DGL 15, 20, 25 - 1/4" and 1/2". Models TGL 30 - 3/8" and 5/8".
● Installation must be performed in accordance with the manufacturer’s specifications, using only approved tubing, original electrical
cables and accessories.
Standard Accessories
Mounting Bracket
Drain hose adapter
≠ ≠
for
≠ DGL/TGL 25-30
≠ ≠
6/7 stations according
to the model
Electrical terminal block
Drain hose adapter
≠ ≠
for
≠ DGL/TGL 9-20
≠ ≠
Long Screws
Remote Controller
Wall Plugs
START
STOP
1 2 3 SLEEP
DAILY
MODE FAN
SWEEP
WIRELESS DIGITAL REMOTE CONTROLLER
and Batteries
Absorption cushions
for DGL and TGL 25-30
Electrical Requirements
● The air conditioner must be directly connected to an
Outdoor sensor
connecting cable
Insulation for Fittings
Model Maximum tubing Maximum height
appropriate power source.
● Use 16A fuses for all Models TGL/DGL air conditioners.
● Use a single-length power cable, without extensions.
● When installing a Dual System air-conditioner of DGL
TGL-9, 11, 15, 20, 25, 30 15 (49') 10 (33')
DGL-9, 11, 15, 20 15 (49') 10 (33')
DGL-11/15 15 (49') 10 (33')
series (a single outdoor unit and two separate indoor units)
both indoor units must be connected to the mains power supply in order for the system to function properly.
Indoor and Outdoor Unit Location
The indoor and outdoor units should be installed as
close to each other as possible. Do not exceed the tubing
lengths and height differences which appear in the accompanying
table above:
Outdoor Unit
● Make sure to leave sufficient space around the unit. See Figure 1 for
minimum required distances between the unit and nearby walls.
● Install the unit in a location with convenient access for service and
maintenance purposes.
● Position the unit to minimize motor noise which reaches the customer
and neighbors.
● In heating mode, water can form in the condenser. A drainage hose may
be attached to the unit. Use the adapter shown Figure 1.
● For opening service door in models TGL 9-20, keep a minimum distance of
0.27m (10" 62') between the unit and the support's end.
● Make sure of installing the unit legs to the support.
Indoor Unit
● Make sure to leave sufficient space around the unit. See Figure 2 for minimum
required distances between the unit and the ceiling, floor and surrounding walls.
● Locate the unit to ensure free air flow around it.
● A 120 cm. power cable is supplied with the unit. We recommend placing the power
outlet near the unit, on its right side.
● Avoid installing the unit near a
source of heat, such as direct
sunlight, steam or a flame.
● Install the unit in a location
with convenient access to
refrigerant line connections
for service and maintenance
purposes.
Indoor Model
Dimensions TGL 9-20 TGL 25-30
mm (")
a 185 (32.3") 185 (45.3")
b 260 (12.6") 295 (13.8")
c 815 (6.7") 1080 (7.9")
0.15m(6")
min.
0.6m(2')
min.
c
WIRELESS DIGITAL REMOTE CONTROLLER
User's Manual
Remote Controller Rack
length in meters (ft) difference between unit
in meters (ft)
Insert the
drainage adapter
from the outside of
the outdoor unit
a
0.6m(2')
min.
0.15m(6")
min.
0.6m
(2')
m
in
b
.
0.15m(6")
min.
0.6m(2')
min.
a
c
TGL 9-20 DGL, TGL 25-30
Insert the
drainage adapter
from the inside of
the outdoor unit
0.6m(2')
min.
b
Outdoor Model
Dimensions TGL 9-20 TGL 25-30
mm (") DGL ALL Plastic Model
a 320 (32.3") 265 (45.3")
b 641 (12.6") 540 (13.8")
c 1100 (6.7") 730 (7.9")
0.15m (6") min.
0.2m
b
")
(8
min.
1.8−2.5m
(6'-8'3
")
c
min.
a
Fig. 2
0.15m(6")
min.
0.6m(2')
min.
Fig. 1
0.2m
")
(8
min.

Installing the Indoor Unit
40 mm
(1”57’)
50 mm (1”96’)
Refrigerant line routing
● The refrigerant lines may be routed in any of the four
directions shown in Figure 3.
1
Installing the mounting bracket
● Pull out the mounting bracket attached to the back of the unit. See Figure 4.
● Position the mounting bracket on the wall and level it using a spirit level.
● Mark the four drilling holes on the wall, as they appear in Figure 4.
● Drill the holes, insert the wall plugs and use the long screws to
attach the mounting bracket to the wall.
● Check that the bracket is level and securely fastened to the wall.
Drilling a hole in the wall
● If refrigerant routing No. 3 is chosen, a hole in the wall must be perform.
● Mark the center of the hole to be drilled according to the refrigerant
routing used and dimensions shown in Figure 4.
● Drill a 70 mm (3") hole in the wall for the refrigerant lines, drainage
hose and electric cables.
● If refrigerant line route nos. 1, 2 or 4 are used, use a small saw blade to
carefully remove the corresponding plastic covering on the side panel.
● Fill the remaining wall hole gap with an appropriate sealant material.
● Mount the indoor unit on the mounting bracket (see Figure 6).
● Make sure to drill outwards and downwards, so that the opening in the
outside wall is at least 10 mm lower than the opening on the inside.
● Make sure the drainage hose is at the bottom side of the hole.
Drainage water form
● Connect the unattached end of the drainage tube to the drainage hose outlet.
● Seal the drainage connection to prevent leakage.
● Make sure there are no kinks, "U" bends or flattened sections in the tube.
● Check that the drainage functions properly. Fill the pan below the unit’s coil
with water and observe that freely drains out. See Figure 5.
Wiring the indoor unit
● Remove the air conditioner cover by lifting the lower part and
then pulling it gently outward. See Figure 8.
● Remove the two screws from the plastic control cover
as shown in Figure 9.
● Route the inter-unit electric cable and the outdoor sensor
cable towards the lower right corner of the indoor unit.
● For TGL 30 model use a screwdriver to insert the bracketped wire
ends (7 mm) into the terminal block, as shown in Figure 9.
● For TGL 9-25 and DGL models insert the bracketped wire ends into
the terminal block and make sure that the screws are properly fastened.
● Make sure that the wires are connected in accordance with the wiring
diagram on the inside of the front cover.
● Attach the inter-unit electric cable with the cable clamp located on the unit.
● Connect the Outdoor Sensor TH3 connector to its mating connector (see Figure 9).
● Close the Plastic control cover with two screws. Keep the Electric cable and
Outdoor sensor cable in between. See Figure 9. If plastic control cover
will close not properly the wiring and cover could be damaged!
Ø 70mm(3")
INDOOR OUTDOOR
10mm(0.5")
min.
1
4
Fig. 3
Fig. 4
F
U
S
E
POWER/AIRCOND
TIMER
FILTER
IR
RECEIVER
Fig. 5
OUTDOOR SENSOR
CABLE
ELECTRICAL
CABLE
REFRIGERANT
LINES
DRAINAGE
TUBE
Fig. 6
Mount the indoor unit
on the mounting bracket
2
3
Attaching the Remote Controller Rack
● Use the two screws supplied to attach the rack to the wall in the
location selected by the customer.
● Please inform the customer to ensure proper operation of the
air conditioner timer program, there should be a clear "line of
sight" available at all times between the remote
controller and the air conditioner.
2
Gently push with
the arrow direction
Fig. 7