Plant I.D. 001-4225 EFFECTIVE: November 1, 2014
102-500
Instruction Sheet
554-7 Wireless Remote Transmitter & Receiver Kit
554-8 Wireless Transmitter Button
Model #: 554-7 Wireless Remote Transmitter & Receiver Kit
Kit Includes: 1 Remote Receiver
3 Wire Nuts
1 Remote Transmitter Button
INSTALLATION INSTRUCTIONS
1. The remote receiver is the small black rectangular box with three protruding wires
(white, black, green). Connect the white, black, and green wires from the remote
receiver directly to the corresponding white, black, and green wires on the TacoGenie
control box by twisting each same colored wire together with the wire nuts provided.
2. When installing the remote receiver under a sink, mount the remote receiver toward
the front of the cabinet (transmitter range is about 70’). If the transmitter button will
activate the pump from a short distance, but not from further away, the receiver may
need to be relocated for better reception. Strapping the receiver to the front of the
drain trap facing outward will optimize reception.
3. NOTE: The remote transmitter button included with the remote is synced for
use. It does not need programming.
4. For additional Wireless Remote Transmitter Buttons, use model 554-8.

Model #: 554-8 Wireless Remote Transmitter Button
Includes: 1 Remote Transmitter Button
6. Place the control board back into the remote receiver cover and reinstall the cover by
aligning the four plastic posts on the base with the four holes in the cover. Make sure
the white wire is properly inserted into the cover cutout. Gently snap the cover and
base together.
PROGRAMMING INSTRUCTIONS
1. Unplug the TacoGenie circulator from the 115V wall outlet.
2. Remove the remote receiver cover (rectangular black box wired to the TacoGenie circulator) separating the top cover from the base plate. A small straight tip screw driver
may be used if necessary. Lift the control board out from the case.
NOTE: The remote transmitter button is provided with a “coin” type lithium battery
installed in the remote transmitter and is ready for programming. 554-8 Remote
Transmitters purchased separately must be synced with the remote receiver.
3. Plug the TacoGenie circulator back into the 115V wall outlet. Circulator will automatically turn on and operate until hot water is detected at the TacoGenie temperature
sensor.
4. A red LED will light on the remote receiver electronic control board once the
TacoGenie is plugged into the wall outlet. The remote receiver must be powered with
the red LED on to properly sync remote receivers.
5. Next to the red LED is a small black button. Press and hold down the black button
and a yellow LED on the other side of the black button will light. While the yellow LED
is on, press and hold the 554-8 Remote Transmitter Button for 3 seconds. Release
the transmitter button, then release the remote receiver button and the yellow LED
will turn off. The Remote Transmitter Button is now synced and ready for operation.
Control BoardBase Cover
Black Button
Yellow LED
Red LED