Taber 710 Operating Instructions Manual

Page 1
Multi-Finger
Scratch/Mar Tester
Model 710
Operating Instructions
INDUSTRIES
9001:2000ISO CERTIFIED
Page 2
WARRANTY
Any product or part which, under normal operat­ing conditions in the facility of the original pur­chaser, proves defective in material or workman­ship within one year from the date of shipment by the company, as determined by an inspection by Taber
®
Industries, will be repaired or replaced free of charge provided you promptly return the defective material. All claims must be sent to Taber Industries with transportation charges pre­paid, notice of the defect and verification the product has been properly installed, maintained and operated within the limits of rated and normal usage.
Replacement parts will be shipped FOB our plant. The terms of this warranty do not in any way extend to any product or part thereof that has a life, under normal usage, inherently short­er than the one-year indicated above. Said war­ranty in respect of replacement of defective parts and any such additional warranty or representa­tion expressly made, are in lieu of all other war­ranties expressed or implied, including any implied warranty of merchantability, or fitness for any particular purpose.
Taber Industries reserves the right to make changes without notice at any time in colors, material, specifications, and models, and to dis­continue models.
CLAIMS FOR SHORTAGES
We use extreme care in selection, checking, and packing to eliminate the possibility of error. If a shipping error is discovered:
1. Carefully examine the packing materials and
ensure nothing was inadvertently overlooked when the shipment was unpacked.
2. Notify the company you purchased the prod-
uct from and immediately report the shortage. The materials are packed at the factory, and should be complete if the box has not been opened.
3. Claims should be filed within 30 days from
shipment.
CLAIMS FOR DAMAGES
Claims for loss or damage in transit should be made promptly and directly to the transportation company.
CONTENTS
Contents of the shipping container should include the following:
• Multi-Finger Scratch / Mar Tester
• Spline Shaft Finger Assembly (5 each)
• Scratch Tip, 1.0mm Diameter Hemisphere (5
each)
• Mar Tip, 7.0mm Diameter Hemisphere (5 each)
• 9 Piece Weight Set - 2N, 3N, 4.5N, 5N, 6N, 7N, 10N, 15N, 20N
• Electronic Timer with Digital Display
• Specimen Clamp with T-Slot Nut, Stud and
Thumb Nut (set of 2)
• Quick Disconnect Socket for Air Supply, with female ¼" NPT thread
• 3/32" Hex Wrench
• Operating Instructions
1 710 Operating Instructions ver 1.1
Page 3
tion such that the scratch pin does not contact the specimen during testing.
Individual weights of varying loads mount to the top of each spline-shaft finger to exert a standard force on the surface of the test material. The standard 9-piece weight set includes loads that range from 2N to 20N. Optional weights are available to test up to 25N.
After lowering the scratch tips onto the specimen surface, compressed air drives the platform under the scratch tips to generate the damage on the specimen surface.
Interchangeable scratch tips include a precision tungsten carbide ball mounted to the contact end. The tips are 1.0mm diameter hemisphere for scratch testing and 7.0mm diameter hemisphere for mar testing. An optional holder permit s testing with a conical diamond scratch tool.
The distance between the bottom of the gantry and specimen table permits testing of flat speci­mens up to 22mm in thickness. Or, the 'free-float­ing' feature of the spline-shaft fingers enables you to evaluate slightly contoured specimens provided they are rigid or adequately supported. A spring­loaded specimen holder is standard and can be mounted to the end or side of the moveable plat­form. For narrow and odd shaped parts, adjustable hold-down clamps are available.
INSTRUMENT SET-UP
Remove all contents from the shipping container and verify that you have all the components.
1. Set the instrument on a flat, level surface. Four suction cup feet will secure the instru­ment to the surface.
2. Install the appropriate tips (scratch or mar) into the end of each spline-shaft finger. Do not over-tighten.
3. Insert the spline-shaft fingers into the guide bearings, by matching the pattern on the shaft and bearing. Each bearing has been pre­adjusted at the factory. If a shaft DOES NOT slide easily through the bearings, see MAINTE­NANCE - Spline Shaft Finger Adjustment.
INTRODUCTION
The Taber®Multi-Finger Scratch /Mar Tester is used to measure the relative resistance or sus­ceptibility of a material surface to scratching, marring, gouging, scraping and other similar physical damage not classified as ordinary wear.
Useful in quality control, materials development and product development, applications for this instrument are diverse. They include plastics; rigid organic materials; paints and coatings; soft metals; linoleum, plus many others. The most common usage has been in the automotive industry, including smooth or grained plastics used in ornamentation or trim.
PRODUCT DESCRIPTION
The design of the Multi-Finger Scratch / Mar Tester is based on the five-finger (five-arm) scratching device described in popular automo­tive test methods.
The instrument includes a pneumatically driven, moveable platform to which the test sample is mounted. The platform moves in a linear fashion and is operated by a control knob, for one or mul­tiple pass testing. An electronic timer displays the rate of speed, which is controlled by reducing or increasing air pressure.
A gantry supports five independent spline-shaft fingers, which provide a constant, vertical load on interchangeable scratch tips (1.0mm or 7.0mm diameter hemisphere). Offering a stable platform to ensure the rigidity for the scratch tips, the gantry system includes a handle to raise and lower the spline-shaft fingers. In addition, five support rests are incorporated to allow one or more fingers to be moved to an upright, rest posi-
2 710 Operating Instructions ver 1.1
Mar Tip Scratch Tip
Page 4
4. Select the weights to be used for testing, and mount to the top of the spline-shaft finger. Align so there is not any contact with the adja­cent weight(s) and tighten in place using the hex wrench. Weights should be mounted from lowest to highest load, to permit ease of evaluation.
X WARNING: To prevent damage to the scratch tips, turn the handle to raise the spline-shaft fingers after the weights are assembled.
5. Attach the quick disconnect socket (sleeve­lock, with female ¼" NPT thread) to the air supply hose, using Teflon tape to seal the threads. If a local air supply is not available, it is acceptable to use a compressor that pro­vides 80 to 100 PSI pressure and has at least a 2 gallon tank capacity. Fasten the hose to the Multi-Finger Scratch / Mar Tester air intake.
6. Connect the electronic timer, matching the green and black cables to their respective sockets (the red socket is not utilized). Insert one AAbattery , ensuring the correct polarity.
SPECIMEN SIZE
To provide for an accurate assessment, speci­mens should be flat panel or regions cut from a sufficiently flat part. The recommended speci­men size is 125mm x 300mm, with a thickness no greater than 22mm. If taken from finished parts, smaller or slightly contoured samples may be used.
To test specimens that exceed the 22mm thick­ness, spacer blocks may be inserted into the support arms of the gantry.
OPERATING PROCEDURES
Prior to testing, it is recommended that all sam­ples be preconditioned in a controlled atmos­phere (such as 23 ±2° C and 50 ±5% relative humidity) for not less than 24 hours. Samples should be tested under the same conditions.
Conducting a Test
• Using the handle, raise the 'fingers' to the
upright position.
• Place a sample on the platform so the surface to be tested is facing upward and is located under the spline-shaft fingers. Taking care not to deform the specimen, secure it using the spring clamp or other specimen clamps.
X WARNING: To prevent movement of the specimen during testing, ensure the specimen contacts a 'stop plate'. The spring clamp can serve this purpose when mounted on the end of the platform. The stop plate should be locat­ed on the opposite side of travel.
• If not already done, install the appropriate scratch (mar) tips and weights.
• Using the red button reset the electronic timer.
• Lower the scratch (mar) tips onto the speci-
men surface and actuate the moveable plat­form by turning the control knob in the direc­tion the table will travel. If one or more scratch fingers are not required, a rest block is provided to raise the finger out of position.
3 710 Operating Instructions ver 1.1
Page 5
SUGGESTION: For soft materials, it is recom­mended to test within 3 seconds after lowering the scratch pins onto the specimen surface.
• Mark the direction of movement of the scratching device on the panels, taking care not to mark the surface just tested.
• Evaluate the extent of the damage on the sample.
Speed Adjustment
Prior to conducting any tests, you will need to adjust the speed of the platform. A sliding veloc­ity of approximately 100mm per second (± 10) is normally recommended.
• Turn the knob on the air regulator/lubricator to an air pressure between 80 - 100 psi. To increase air pressure, turn the knob clockwise (to decrease turn counterclockwise).
• Using the handle, raise the 'fingers' to the upright position.
• Press the red button to reset the electronic timer.
• Actuate the moveable platform by turning the
control knob in the direction the table will trav­el. The number displayed on the timer, indi­cates the time in seconds it takes the platform to travel 100mm.
• To adjust platform speed, turn the flow control valves found on the right hand side of the instrument. Turning the valve counter-clock­wise will increase the speed, while turning it clockwise will decrease the speed. If you are testing in both directions, ensure the platform travels at the same rate. The valve toward the front of the instrument controls the speed when the platform is moving to the left. The valve toward the back, controls the speed when the platform is moving to the right.
• After adjusting the flow control valve, lock in place by tightening the lock thumbnut.
• Lower the scratch (mar) tips onto a ‘dummy’ test specimen, and verify the speed adjustment.
X WARNING: It is possible for the speed of the platform to exceed the capacity of the automatic Start/Stop of the electronic timer. Should this occur, disconnect the timer and operate electronic timer by hand using the Green button to Start and Stop.
Weight Adjustment
If you are not following a test method that indi­cates which weights are required, start with 3N, 5N, 7N, 10N, and 15N. Loads can be increased or decreased accordingly.
CALCULATION OF RESULTS
Depending on the type of material under evalua­tion, the visual appearance of a scratch normally involves changes in surface topography, color, or brightness. Three methods are normally used:
Method A - Visual Evaluation:
Using a controlled light source, hold the sample such that the scratch lines are in a horizontal posi­tion to the observer. The scratch line caused by the highest weight should be at the upper position.
Rotate the sample, so the angle of observation changes. The observer should be checking each scratch line individually, and noting the point at which the scratch lines emerge at the clearest vis­ibility. Do not use the starting and ending point of the scratch lines (approx. 10mm) in this evaluation.
Examine all scratch lines and rate according to a Rating Scale 1 to 5 (1 = no scratch line at all; 5 = severe scratch line). For plastic materials, indi­cate if the line exhibits signs of whitening.
Report the tip diameter, stylus loading level, and Rating Number for each line on the surface of the sample.
SUGGESTION:
A lightbooth with North Sky Daylight (D65) has been recommend as a lighting source for automotive specifications.
4 710 Operating Instructions ver 1.1
Page 6
Method B - Width/Depth:
Measure the width or depth of the scratch (grooves) using an optical measuring device.
Method C - Image Analysis:
The scratch mark intensity may also be evaluat­ed by using Image Analysis techniques.
NOTE: Detailed descriptions are recommended when depicting scratch or mar damage. Items that might be described include surface topogra­phy, material deformation, material removal, and color changes. The following examples have been used to describe damage in plastics:
- scratch is shallow (or deep)
- scratch is smooth, with a well defined shape
(or rough and deformed)
- scratch includes plastic flow of the material (or cutting, tearing, cracking, chipping, crazing)
- scratch includes visible ripple marks at the bottom (i.e. chevron or parabolic shaped)
- strain whitening is visible (or no change in color)
INFLUENCES ON RESULTS
For comparable and reproducible tests, it is rec­ommended the operations be performed under conditions covered by an established test proce­dure. The following factors are known to affect the scratch resistance of materials, and could potentially impact your test results:
Test methodologyTest conditions (i.e. temperature or humidity)Scratching speedGeometry and condition of scratch tip or
indenter tool
Applied load Material (i.e. filler type; additives; lubricant;
polymer type)
Surface roughness and grain directionType and thickness of surface treatmentElastic properties of the specimen
Method of scratch assessmentLength of time between scratch and evaluation
Plastics
The properties of plastic materials can greatly influence the evaluation of scratch and mar resistance. It is important to be aware of the fol­lowing factors and take them into consideration:
1. Many plastics have elastic recovery upon removal of applied stress.
2. Many plastics have visco-elastic properties and the stresses in the plastics may relax dur­ing loading.
3. Plastics may change structure during material flow, which can also change the mechanical properties of plastics.
Irregular Surfaces
The existence of 'chatter' in a scratch path may indicate a non-uniform composition or the pres­ence of surface irregularities. An irregular sur­face may also cause a scratch pin to 'bounce' on the specimen surface, resulting in additional impact force at landing points and additional damage to the surface.
MAINTENANCE
Taber recommends annual factory calibration at which time the unit will be thoroughly checked.
Care of the Scratch Tips
The precision cutting edge of the scratch (mar) tips is fragile, and must be handled with care. Depending on the material being tested, tips can provide months of satisfactory service.
» Do not scrape the cutting edge of the scratch
tip against a hard surface, such as steel. Doing so may prematurely dull the tool.
to drop against the specimen or platform. Carefully lower them against the specimen just prior to making a test.
The scratch tip will eventually become dull through use. It is recommended that several spare tips be kept on hand for replacement and standardization purposes.
5 710 Operating Instructions ver 1.1
Page 7
Spline Shaft Finger - Adjustment
The following procedure describes the correct way to adjust the spline-shaft fingers.
1. Using hex wrench supplied, loosen set screw and remove weight from spline-shaft finger.
2. If upper bearing (#5) is assembled tightly in gantry and locked with bottom set screw (#4), continue with step 3. Otherwise,
a. Remove spline shaft (#1) from bearing
assembly.
b. Hand-tighten upper bearing (#5) and
lock with bottom set screw (#4A).
c. Adjust lower bearing (#2) into beam until
shoulder of bearing is in contact with gantry .
d. Slide spline shaft (#1) into upper bearing
until shaft stops against lower bearing. Lightly twist lower bearing clockwise until spline grooves align into lower bearing and slide freely.
3. Loosen two adjustment set screws (#4B & C) approximately ½ to ¾ turn.
4. Apply light tension between spline shaft and lower bearing by slightly twisting lower bear­ing counter-clockwise.
5. Using hex wrench, apply a light tightening force to top set screw (#4B) locking lower bearing into place. WARNING, DO NOT OVER TIGHTEN SET SCREW. Spline shaft will no longer move freely through bearings.
7. Re-attach weight and tighten set screws.
Load on Specimen Surface
To check the loading forces, measure directly under the scratch (mar) tip, using a spring bal­ance or equivalent. If necessary, adjust the weight(s) to meet the required scratch force(s) on the surface of the sample.
Lubricator / Regulator
The maximum inlet pressures and temperatures are as follows:
150 psig (10.3 bar) 125° F (51.7° C)
Given normal operating conditions this unit will be trouble-free. It is recommended that you serv­ice the unit at least every six months.
CLEANING: To clean bowl assembly: a. Depressurize unit. b. Remove bowl and bowl guard assembly by
turning counterclockwise.
ed seals. Replace with original manufacturers approved seals and bowls.
d. If bowl becomes dirty, replace it or clean it by
wiping the bowl with a soft dry cloth or a mild detergent.
e. Before returning to service, ensure that all
seals have been reinstalled or replaced.
6 710 Operating Instructions ver 1.1
Page 8
f. Reinstall bowl and bowl guard assembly and
rotate bowl guard clockwise to securely lock in place. Align arrow on bowl guard with arrow on lubricator body.
Occasionally, liquid water will get trapped in the lubricator bowl. Since water is denser than oil, the water will migrate to the bottom of the bowl. Periodically clean bowl to remove the liquid water.
ADDING OIL
: Use clean oil, preferably SAE 10 or lighter. Do not use phosphate ester or diestor based fluids in lubricators.
The lubricator can be filled under pressure by removing the fill-plug slowly, allowing the pres­sure in the bowl to vent to atmosphere. After the pressure is bled off, the fill plug may be removed completely and oil poured into the fill port. When the fill plug is removed, a small amount of air will be venting from the fill port. This is to serve as an audible signal denoting that the unit is in fact under pressure. If faster filling is desired, slowly remove the fill plug to vent the bowl pressure to atmosphere. Then remove the bowl and bowl guard assembly by turning counterclockwise. Fill the bowl, reposition the bowl o-ring seal and rein­stall the bowl into the body and turn clockwise to securely lock in place. Reinstall the fill plug. The unit is ready for use.
ADJUSTING DELIVER
Y RATE: The oil delivery rate will change automatically to deliver more oil during increase airflow demand and less oil for airflow lower than the original setting. To adjust and set oil delivery rate, the unit must be pressur­ized and flowing air. Turn the transparent sight dome counter-clockwise to initiate/increase oil delivery. Turn the sight dome clockwise to decrease/stop oil delivery.
If the oil delivery rate should drop, the lubricator should be inspected and cleaned to remove con­taminates.
Electronic Timer
The electronic timer has been designed to offer accurate time measurement over a long period provided the following cautionary steps are main­tained,
are very hot or humid.
• Do not use abrasive or corrosive substances
to clean.
• It should not be dropped or shaken vigorously.
FACTORY SERVICE
Should your Multi-Finger Scratch / Mar Tester require repair or adjustment, carefully pack it in a rugged container with plenty of cushioning mate­rial. After obtaining a return authorization num­ber from the factory, the unit should be shipped, transportation charges prepaid, to:
TABER Industries
455 Bryant Street North Tonawanda, New York 14120 USA
7 710 Operating Instructions ver 1.1
Page 9
CONSUMABLES / ACCESSORIES
Description Model Number Part Number
Scratch Tip, 1.0 mm diameter hemisphere (each) 132347 Scratch Tip, 1.0 mm diameter hemisphere (set of 5) 132532 Mar Tip, 7.0 mm diameter hemisphere (each) 132348 Mar Tip, 7.0 mm diameter hemisphere (set of 5) 132533 Diamond Tool Holder, includes 121006 conical diamond tool
w/90° 3 mil (0.003”) radius point 132892 Diamond Tool Holder, includes 121006-1 conical diamond tool
w/90° 3.5 mil (0.0035”) radius point 132891 Conical Diamond Tool, with 90° 3 mil (0.003”) 139-55 121006 Conical Diamond Tool, with 90° 3.5 mil (0.0035”) 139-56 121006-1 Precision Weight Kit (Used to achieve 0.6N) 132740 Optional Weight Set (8N, 13N, 18N) 132401 Optional Weight (25N) 132352-5 Standard Specimen Hold-Down Clamp Kit (each) 132455 Oversized 'EZY' Specimen Hold-Down Clamp (each) 132399 Specimen Platform Protective Guard, Replacement 132451 3/32" Hex Wrench, Replacement 130808
TABER®Industries 455 Bryant Street North Tonawanda, New York 14120 USA
Toll-Free: 800.333.5300 Phone: 716.694.4000 Fax: 716.694.1450 E-mail: [email protected] WebSite: www.TaberIndustries.com
www.OrderTaber.com
8 710 Operating Instructions ver 1.1
Page 10
NOTES:
Loading...