SyxthSense SST-A24-302, SST-A24-304, SST-A24-306, SST-A230-302, SST-A230-304 User Manual

...
Online store: www.syxthsense.com
Enquiries: T: 0844 840 3100 F: 0844 840 3200
PS TH6.90 - 1/5
SST Series Digital Thermostats
SST series are elegant thermostats with a large clear LCD screen. The thermostats are operated with five high quality buttons. The SST range is available with a range of models to suit most heating applications.
The SST thermostats can be extensively applied for residential, indu
strial and commercial environment. The thermostats have switching rating of up to 16A 230V making them suitable for both wet systems and electrical heating systems.
Depending on the model, the thermostats can operate using inter
nal or external sensor and can have an additional high limit floor sensor.
The SST range has RS485 communication capability making them idea
l for multi-zone and for high energy efficiency applications.
Features
• 24VAC or 230VAC Power Supply
• Large Digital Display with Back-Light
• Flush Mounted for Sophiticated Look
• Switching rating up to 16A 230V
• Celcius / Fahrenheit Display
• Low Temperature Protection
• Unique Lockable Keypad
• RS-485 Modbus Communication Network
• All temperature readings and settings ava
ilable via Network
Product sheet TH6.90
Thermostat Type SST
Model Type Model Description
SST-A24-302 Digital Thermostat, 24Vac, Floor Sensor
SST-A24-304 Digital Thermostat, 24Vac, Internal/External Sensor
SST-A24-306 Digital Thermostat, 24Vac, Internal/External and Floor Sensor
SST-A230-302 Digital Thermostat, 230Vac, Floor Sensor
SST-A230-304 Digital Thermostat, 230Vac, Internal/External Sensor
SST-A230-306 Digital Thermostat, 230Vac, Internal/External and Floor Sensor
SST-RB-01 Flying Lead Floor Temperature Sensor
SST-RC02 Infrared Remote Control for the Room Thermostats
TEFM-NTC100K Flush Mounted NTC100k Temperature Sensor
Technical Data Power Supply A24 Models: AC24V ± 10%, DC24V
A230 Models: AC230V ±10% 50/60Hz
Power Consumption < 1W
Switching Voltage AC220V ± 10% 16A SPST N/O (Resitive Load)
Output Signal ON/OFF
Measurement Range 5..95°C
Accuracy 0.5°C/F
Working Temperature 0..70°C
Sensor Characteristics NTC100kOhm
Setpoint Range 5 to 95°C/F
Terminals Max 2.5 mm
2
(min 0.5mm2)
Communication RS485 Modbus RTU, up to 32 devices (logical address range 1..32)
Modbus Settings 9600 baud, 8 Data Bits, None Parity, 1 Stop Bit, Maximum Setpoint
Writes 100,000 Cycles (Holding Register)
Color White with Glass Panel
SyxthSense Ltd
Copyright © 2013 SyxthSense Ltd. All rights reserved - 02/2013
PS TH6.90 - 2/5
Online store: www.syxthsense.com
Enquiries: T: 0844 840 3100 F: 0844 840 3200
Operating Instructions Unit On/Off
UP button
DOWN button
CLOCK button (not in use)
HOLD button
OFF button
H
20
5
INSIDE
SET TEMP
20
°C
Current Setpoint (Resolution 1°C)
Current Temperature (Display Resolution 0.5°C)
Press OFF button to turn ON or OFF the thermostat.
Temperature Setting
When the thermostat is ON, press UP or DOWN butto
ns to set the desired temperature. If the temperature is set at "- -", the thermostat is disabled.
Manual Temperature Override
When the thermostat is ON, press the button H t
o display the HOLD icon. The thermostat is overridden ON at the current setpoint until the override has been cancelled. The HOLD button is a quick way to freeze the current setpoint.
Keypad Lock Function
Simultaneously press UP and DOWN buttons for 1
0 seconds to lock the thermostat. The LOCK icon is displayed on the thermostat. In this mode it is not possible to adjust the temperature setpoint. As default it is possible to switch the thermostat OFF. All user interactions can be disabled via advanced configuration parameters.
To unlock the thermostat, press UP and DOWN buttons again simultaneously for 10 seconds. The LOC
K icon on the thermostat disappears.
Thermostat ON/OFF Timer (with Remot
e Control only)
When this function has been set via remote control, the
TIMER icon is displayed together with the
counting down time.
Error Display
When errors occur on the themostat, the ERROR ico
n is displayed together with error code. The
following list describes the error codes.
1 =Internal Temperature Sensor Error
2 =External Temperature Sensor Error (if re
quired change the sensor selection under the
advanced configuration options)
3 = Floor Temperature Sensor Error
10 = Internal Data Storage Display
Communication Display
When the COMMUNICATION icon is displayed, the ther
mostat is communicating with the network
master.
Low Temperature Protection The thermostats has low temperature protection feature.
If the measured temperature drops below the frost setpoint (default 7°C), the thermostat relay is switched ON even if the thermostat has been turned off from the ON/OFF button.
The Low Temperature Protection feature can be disabled in the Advanced Configur
ation Parameters.
Housing ABS Flame Retardant
Mounting
Flush Mounting (wall mounting using a separate box)
Dimensions W86 x H86 x D14.5 mm
Environmental Conditions Operating Temp 0..+50°C
Humidity Limits 0..95% rH non-condensing
Storage Temp -20..+50°C, Humidity <95% rH
Environmental Standards
IEC721-3-3, Climatic Conditions Class 3K5 EN 60730