SYStronics STH-PR5N-F User Manual

STH-PR5N_F MANUAL
1
USER MANUAL
Temperature·Humidity Sensor for Record Output
VER:201805-1.0
STH-PR5N F
-
1404, 301, Bucheon Techno park, 345, Seokcheon-ro, Bucheon-si, Gyeonggi-do, Republic of Korea
Phone : +10-32-324-2777 Fax : +10-32-324-2717 Homepage : www.ss22.com
STH-PR5N_F MANUAL
2
Be sure to read and ensure that your safety precautions are used to protect your safety and prevent property damage. We shall not accept any liability for any loss caused by the use or carelessness caused by the use or handling of this manual.
Warning
If this product is not intended as a safety device, use a double safety device for fear of accidents, damage of critical peripheral equipment, and equipment that is feared to cause extensive property damage.
Safety instructions
1. Be sure to check the equipment after disconnecting mains.
2. Do not disassemble and repair this product ; it is not possible to manufacture any product.
3. Do not spray water directly or clean it with benzene, jazzy, or alcohol.
Notes on the environment
Do not install this product in the following locations and environments :
1. Places directly exposed to mechanical vibration or shock
2. Places exposed to corrosive gases or combustible gases
3. Position directly exposed directly to direct sunlight
4. Places affected by electromagnetic waves
5. Places where high temperature or humidity is high (sites with over 85 % of ambient humidity)
6. Places where dust and salt are plentiful
Precautions on installation
1. Make sure that the installation work is related to the installation or qualified personnel only.
2. Do not place any device or wiring that caused noise (NOISE) near the product.
3. Avoid near heating apparatus.
4. Disconnect all appliances (OFF) after disconnecting them from the wiring.
5. Do not work with wet hands. Risk of electric shock.
6. Install and use the method described in the User Manual as instructed in the Instructions for Use.
7. Do not turn on (power on) prior to the connection between the unit of manufacture of this unit.
8. Do not use any load exceeding the opening and closing capacity of the output contacts.
Immunity condition
1. In addition to the contents set forth herein, no warranties and responsibilities shall be made regarding this product.
2. Whether or not this product is likely to be unforeseen defects and natural disasters due to the use of this product, the user or the third person We shall not be held liable for any indirect damage.
Precautions
STH-PR5N_F MANUAL
3
Product Overview
It is a room type sensor that can incorporate a digital temperaturhumidity sensor element and
install it in equipment and favorite place. And It is easy to use in the field where the temperature and
humidity need to be precisely monitored such as the thermo-hygrostat, low-temperature warehouse. And It is
a product that can output temperature and humidity data as analog signals. In addition, it is easy
to monitor and set by placing FND and buttons on the front.
·Digital temperaturhumidity sensor
·Monitoring with front panel FND
·Temperaturhumidity data analog signal output
STH-PR5N_F MANUAL
4
Detailed Structure of Product
Product Component
Sensor probe
ABS
Body fastening screw 4EA
More than M3 × 8
FND Display
4 Digit FND x 2EA
Control unit
Button Key
Sensor body
ABS
Cable gland
PG9
STH-PR5N_F MANUAL
5
Temperature Sensor Specifications
Measuring Range -20.0 ~ 80.0
Accuracy ±0.3(Max ±0.4℃)
Resolution 0.015
Reaction Time 2.0 sec
Humidity Sensor Specifications
Measuring Range 0 ~ 100% RH
Accuracy ±3% RH (Max ±4.5% RH)
Resolution 0.01% RH
Reaction Time 8.0 sec
Product Specifications
Controller Specifications
Input Power DC 24Vdc
Power Consumption 75mA / 1.8W (at 24Vdc)
Output Spec. DC 1~5V / 4~20mA
Operating Temp. -20 ~ 80(Non condensing)
Operating Humi. 5 ~ 95% (Non condensing)
Storage Temp. 0 ~ 60(Non condensing)
Body Weight 268.0g (Cable basic 3M)
Cable Weight 94.0g
Cable Length Basic 3M (Can be changeable / AWG standard : More than 20)
Temperature Accuracy Graph
0.0
0.5
1.0
1.5
-40 -20 0 20 40 60 80 100 120
Temperature ()
±
±
±
±
T (℃)
0
1
2
3
4
5
6
7
8
0 10 20 30 40 50 60 70 80 90 100
Relative Humidity (%RH)
±
±
±
±
±
±
±
±
±
RH (%RH)
Humidity Accuracy Graph
Maximal Tolerance
Typical Tolerance
Maximal Tolerance
Typical Tolerance
Loading...
+ 11 hidden pages