System Cleaners MS5, MS7, PS1, PS5, PS7 User Manual

...
Version 9 (02.2018. EN)
MANUAL
MS5 and MS7 PS1, PS3, PS5 and PS7
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 2 of 48
General
For safety during installation and later use it is very important that installation, operating and maintenance instructions are carefully followed.
You are requested to keep this instruction manual at a location where it will be available at all times, and it should be submitted to the person who is responsible for this product. In the event that the instruction manual is lost, you are welcome to order a new one from your dealer.
If any doubt should arise with regard to the content of these instructions, please contact the distributor.
Proper use
System Cleaners’ system is exclusively designed to transport and pressure-increase of water to satellite stations. All other forms of application or use not within the scope of the above are considered to be improper and inconsistent with the requirements and regulations, and may lead to hazardous situations.
System Cleaners A/S cannot be held liable for consequential damage resulting from improper use of the equipment.
Proper use includes the following:
The instructions, regulations and recommendations concerning the system stated in the instruction manual Observance of the specified inspection and maintenance intervals Correct maintenance of good operating condition of the system Observance of the specified environmental and operating conditions
Proper use also includes observance of all information that is stated in this instruction manual. This applies in particular to the specified safety instructions.
Liability
Each user must handle and use the system in a responsible manner.
It is therefore of great importance that this instruction manual is available to the sanitation employee concerned at all times.
Safety
The design of the system complies with generally accepted technical regulations and provisions concerning the working environment and accident prevention. Despite this, risks can occur during use that can lead to physical inconvenience for the user or a third party or have an impact on the machine or other equipment.
The system must therefore be in prime technical condition before use and may only be used in accordance with its purpose and with strict observance of the safety requirements and operating instructions. In particular, malfunctions and irregularities that can affect safety must be remedied immediately.
Warranty
For a period of 24 months from the date of delivery, your dealer will honor a warranty on parts that do not function properly due to material defects or manufacturing faults. The warranty does not cover wearing parts. The warranty will cover replacement or repair of the defective part. Costs with regard to dismantling, forwarding and reassembly are defrayed by the purchaser. Any return shipments from System Cleaners A/S following completed repairs are defrayed by System Cleaners A/S. The defective parts remain the property of System Cleaners A/S.
Claims that may be made for legal reasons, ordinary wear and tear, as well as damage to parts that can be attributed to negligent or improper handling are not covered by the warranty. The warranty will be void if the system has been exposed to frost. The warranty will also be void if modifications or repairs have been carried out by unauthorized personnel. Warranty claims will only be accepted if they are reported to System Cleaners A/S immediately after damage has been discovered. The warranty is terminated if there is a change of ownership of the machine. System Cleaners A/S and its dealers cannot be held liable for personal injury, damage to equipment, loss of earnings, including production losses, losses to stock or similar that may have arisen as a result of defects or delayed delivery of the sold product, irrespective of the cause, including manufacturing faults or material defects. In addition, please refer to our general terms and conditions of sales and delivery.
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 3 of 48
Disposal
Please be aware of the following applicable provisions: the equipment must be disposed of according to its nature and applicable requirements, e.g. electrical scrap, synthetic material, stainless steel, brass, etc.
Labelling
The system is equipped with a type plate containing technical data.
The type plate is located on a fixed part of the system.
Declaration of conformity
We declare that this product is in conformity with the following directives:
2006/42/EC Directive on Machinery 2014/35/EU Low Voltage Directive 2014/30/EU EMC Directive
Per Kjøller
Development Manager
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 4 of 48
DESCRIPTION
Main station (MS5 and MS7)
A main station has a built-in pump, a built-in satellite and is connected to electrical power, water mains, a number of chemicals and compressed air. It supplies pressurized water to the built-in satellite and a number of external satellites.
With the built-in satellite it is possible for one operator to rinse, foam or disinfect (depending on model) while pressurized water is supplied to external satellites.
The outlet pressure is constant regardless of the number of connected satellites in use.
The pump is protected from dry running in case of insufficient water supply.
The main station is protected from excessive water temperatures by a switch in the pump.
Pump station (PS1, PS3, PS5 and PS7)
A pump station has a built-in pump and is connected to electrical power, water mains and supplies pressurized water to a number of satellites.
The outlet pressure is constant regardless of the number of connected satellites in use.
The pump is protected from dry running in case of insufficient water supply.
The pump station is protected from excessive water temperatures by a switch in the pump.
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 5 of 48
Pos.
Description
1
Input 1.1/2”
2
Outlet 1.1/2”
3
Air connection ø8
4
Temperature switch
5
Pressure switch
6
Filter
7
Input pressure
8
Flow switch
9
Pneumatic assembly
10
Non-return valve
11
Outlet pressure
12
Pressure transmitter
13
Injector system
14
Start/Stop
15
Pump
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 6 of 48
INSTALLATION
Storage
The machine must not be exposed to frost unless it has been emptied of water (frost protected). Even brief periods of exposure to frost may cause damage to the equipment.
Store the equipment in a frost-free room in the original packing.
Installation
Place the equipment in a frost-free room, well protected from the sun and place it on a hard surface.
Make sure that, in the event of failing non-return valves in the air and water supply, there are suitable back-flow preventers fitted.
Local regulations may require installation of a back-flow protecting device to prevent compressed air or chemicals getting into the water supply.
Piping
The piping should be made from materials suitable for the media in the pipes, the maximum pressure and temperature.
It is the fitter’s responsibility to ensure that the piping including all armatures conform to local regulations.
The installation must be performed such that forces from pipes etc. are not transferred to the equipment during and after fitting, as this may result in leaks or damage the equipment.
Select a pipe size so that the flow velocity in the pipe is up to 3 meters/second (10 feet/second). This gives a normally accepted pressure loss and low noise from the flow.
In order to facilitate maintenance of the equipment, it is recommended to fit a shut-off valve in the pipelines immediately at the connections for water.
Pipe supports
Always use pipe supports designed for the pipe size and material and maximum working pressure and temperature.
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 7 of 48
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 8 of 48
COMMISSIONING
Flushing
Pipes etc. must be flushed efficiently before connecting the unit.
Before commencing operation on the unit or following repair work, the unit must be flushed thoroughly to remove any impurities or foreign bodies.
Bleeding
Prior to starting the system for the first time and following any interruption of the water supply, the pump and pipelines must be bled thoroughly to avoid damage to the pump’s shaft seal.
Air pockets in the pipes may cause destructive water hammer when the pump starts.
Disinfection
Local specifications may require disinfection of the wetted parts like internals of pipes and pumps before use to avoid contamination of newly cleaned surfaces.
Dosing (MS5 and MS7)
Adjust the dosing according to the chemical supplier’s recommendations.
Always calibrate and, if required, document the dosing on a regular basis.
Air (MS5 and MS7)
Adjust the air pressure until a satisfactory foam quality is achieved.
Note that good foam quality depends on the mixture of water, chemical and air and getting a perfect result requires some adjustments of the mixing ratios.
OPERATION
Safety
It is recommended that suitable working clothes be worn. For protection against certain types of detergents, always use protective goggles, respiratory protective equipment and rubber gloves.
It is recommended that non-slip footwear be worn since the floor can be slippery due to the presence of water and foam.
This system may only be operated, maintained and – not least - repaired by persons who are familiar with the system and properly trained to carry out the job concerned.
It is the customer’s responsibility that these installation and operating instructions are supplemented by in-house instructions concerning inspection and reporting, industrial management, personnel training, etc.
Do not carry out any work if you are unsure of the consequences or are insufficiently skilled to carry it out. If in doubt, you should contact your superior or your agent in advance.
Never direct the water jet at other persons.
Never direct the water jet at electrical installations.
Check that couplings “lock” when hoses and nozzles are fitted. If possible, practise this procedure before operation.
Always relieve the pressure in the rinsing hose by opening the low-pressure gun or valve after the water supply has been shut off before dismantling the couplings and removing the hose.
During operation of the system, ensure that the low-pressure gun/valve is closed before releasing the handle.
When the low-pressure gun or valve is opened, the water jet will result in a certain amount of counter-pressure. Therefore make sure that you hold the handle firmly and have a firm foothold.
Before removing the cabinet, the power supply must be switched off.
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 9 of 48
Safety precautions and safety devices must comply with national regulations applicable at any time.
Internally, protection corresponds to IP 55. On a number of components hazardous voltages can occur. During operation the cabinet must always be closed.
Never insert or remove a plug from an electrical socket unless the power has been switched off.
System Cleaners low-pressure systems may only be used in conjunction with soaps and chemicals that are approved for cleaning within the food or transport industries.
Soaps and chemicals that are classified as highly corrosive, toxic or which pose a health risk to humans or animals may not be used.
The system must not be used together with solvents or volatile liquids that pose a health risk or are inflammable.
In the event that the system is used with non-approved soaps, chemicals or solvents, System Cleaners A/S disclaims all liability.
If in doubt, please contact your soap or chemical supplier and read the supplier manual.
In the event that you use the system with chemicals that require mandatory labelling, or if the water temperature exceeds 50°C, a low-pressure gun with an automatic closing device must be used.
Start
The system starts automatically in the event of falling pressure in the outlet pipe like when the operator opens the low pressure gun or valve.
Pressure setting (remote control)
Use the optional R100 remote control or the optional Bluetooth dongle to change the pressure set point. Be careful not to set the pressure below 15 bar (217 psi) if the unit is supplying a satellite – both built-in and external - as this may compromise the function of the injector.
Stop
The system stops automatically shortly after water is no longer being used like when the operator closes the low pressure gun or valve.
Leaks
If there are leaks in the system’s non-return valve, pipelines or satellites, the pump will start although there is no water being used.
Flush injector system (MS5 and MS7)
After each use flush the injector system with warm water to avoid clogging of the injector.
MAINTENANCE
Water filter
Depending on the mains water quality it may be necessary to clean the water filter on a regular basis to prevent the pump from stopping.
Flow switch
The flow switch does not require maintenance.
Shaft seal
The shaft seal does not require maintenance. Leaks are normally a sign of dry running caused by insufficient water supply to the pump.
Water non-return valve
Water non-return valves are critical wear parts and should be replaced yearly.
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 10 of 48
Pump, motor and frequency drive
Scaling compromises the function of the pump and de-scaling following the chemical supplier’s guidelines may be necessary on a regular basis. Motor and frequency drive do not require maintenance.
Air filter (MS5 and MS7)
Depending on the quality of the compressed air it may be necessary to empty condensation collected in the air filter bowl on a regular basis.
Injector system (MS5 and MS7)
The injector system consists of foot strainer, dosing valve, non-return valve and injector.
Chemical residues compromises the function of the injector and flushing with warm water after each use is required to maintain trouble free operation.
Depending on the water quality it may be necessary to de-scale the water side of the injector on a regular basis following the chemical supplier’s guidelines.
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 11 of 48
TROUBLE SHOOTING MS5 and MS7
Fault
Cause
Remedy
No water or insufficient water at the nozzle when rinsing
Function selector is in closed position
Turn the function selector switch to the desired function
Insufficient water supply to the unit
Make sure that the water supply is as described in the technical specifications
Valve at the end of the hose not open
Open valve
The unit does not suck up detergent
Function selector is not in the correct position
Turn function selector switch to desired function
Suction filter or chemical restrictor are blocked by chemical residue
Clean suction filter or chemical restrictor
Water pressure is too low
Make sure water supply is as described in the technical specifications
Suction filter is above the fluid level in chemical container
Position the suction filter below fluid level
Poor foam quality
Chemical product is not a foaming product
Change to a foaming chemical
Incorrect dosing
Adjust the dosing according to chemical supplier’s specifications
Suction filter or chemical restrictor are blocked by chemical residue
Clean the suction filter or chemical restrictor
Water pressure is too low
Make sure that the water supply is as described in the technical specifications
Air pressure too low
Increase air pressure
Non-original foam nozzle fitted
Replace with original white foam nozzle
Fault
Cause
Remedy
Rinse pressure too low
Pump station not started
Press green button
Too many simultaneous users
Reduce the number of simultaneous users
Pump stopped due to inlet pressure less than 1.5 bar (23 psi)
Increase inlet pressure to between 1.5 and 10 bar (23 and 145 psi)
The device will not start
Valve in inlet or outlet closed
Open valves
Inlet water pressure less than 1.5 bar (23 psi)
Increase inlet pressure to between 1.5 and 10 bar (23 and 145 psi)
TROUBLE SHOOTING PS1, PS3, PS5 and PS7
Fault
Cause
Remedy
Rinse pressure too low
Pump station not started
Press green button
Too many simultaneous users
Reduce the number of simultaneous users
Pump stopped due to inlet pressure less than 1.5 bar (23 psi)
Increase inlet pressure to between 1.5 and 10 bar (23 and 145 psi)
The device will not start
Valve in inlet or outlet closed
Open valves
Inlet water pressure less than 1.5 bar (23 psi)
Increase inlet pressure to between 1.5 and 10 bar (23 and 145 psi)
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 12 of 48
Spare parts machine
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 13 of 48
Spare parts Cabinet
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 14 of 48
Pos.
Part no.
Description
Material
Version
1
04-000072
Plastic knob 30mm
Plastic
All
2
04-000178
Spacer ø25x25,75 sort
PVC-U
All
3
08-000502
Lock nut M5
A2
All
4
08-000504
Cap nut M5
A2
All
5
08-000602
Lock nut M6
A2
All
6
08-000801
Nut M8
A2
MS5, PS1, PS3, PS5
6
08-001001
Nut M10
A2
MS7, PS7
7
08-001201
Lock nut M12
A2
All
8
08-100515
Screw buttonhead M5x10mm
A2
All
9
08-100610
Coach screw M6x80mm
A2
All
10
08-100801
Coach screw M8x60
A2
All
11
08-104015
Screw for plastic 5x12
A2
All
12
08-105020
Spring pin ø3x8 RF
A2
All
13
08-200602
Set screw M6x20
A2
All
14
08-200805
Set screw M8x20
A2
All
15
08-200808
Set screw M8x16
A2
All
16
08-201207
Set screw M12x40
A2
MS5, PS1, PS3, PS5
16
08-201211
Set screw M12x45
A2
MS7, PS7
17
08-300602
Disc washer ø6
A2
All
18
08-300605
Disc washer ø6
Nylon
All
19
08-300803
Plane washer ø8
A2
All
20
08-301202
Disc washer ø12
A2
All
21
08-800505
Cheese-head screw M5x10
A2
All
22
08-800601
Cheese-head screw M6x20
A2
All
23
08-800835
Cheese-head screw M8x35
A2
MS5, PS1, PS3, PS5
23
08-801003
Cheese-head screw M10x45
A2
MS7, PS7
24
08-900008
Rawlplugs S 8
PVC
All
25
08-900010
Rawlplugs S 10
PVC
All
26
15-200082
Socket 1/4"x1/8"
AISI 316
All
27
16-501200
Plug 1/2"
AISI 304
All
28
16-501403
Plug 1/4" 9mm
AISI 316
All
29
17-000032
O-ring 10,1x1,6 NBR 70 shore
NBR
All
30
17-010010
O-ring 46x3
NBR
MS5, PS1, PS3, PS5
30
17-010011
O-ring 70x4
NBR
MS7, PS7
31
17-020004
O-ring 47,29x2,62 EPDM 70 sh
EPDM
All
32
17-020017
O-ring 55,2x3 EPDM
EPDM
All
33
17-020055
O-ring 10x2 70 shore
EPDM
All
34
17-020056
O-ring 11x1,5 70 shore
EPDM
All
35
17-020080
O-ring 18x2 70 shore
EPDM
All
36
20-010006
Cap for Non-return valve
AISI 303
All
37
20-010007
Flange for Non-return valve
AISI 303
All
38
20-010008
Cap for Filter
AISI 303
All
39
20-010009
Flange for Filter
AISI 303
All
40
20-200200
Non-return valve 1.1/2"
AISI 304/NBR
All
41
20-510040
Filter insertion 1.1/2" 800 µm
AISI 304
All
42
21-000022
Insert for flow-switch
AISI 303
All
43
21-000025
Flow switch 1.1/2"
-
All
44
21-000102
Angle connector M12x5m
-
All
45
22-000042
Gauge ø50 0-60 bar SS
AISI 304/brass/glycerine
All
46
22-000044
Gauge ø50, -1-16 bar SS
AISI 304/brass/glycerine
All
47
25-050019
Inlet pipe 1.1/4"/1.1/2" BSP
AISI 304
MS5, PS1, PS3, PS5
BSP
47
25-050020
Inlet pipe 1.1/2" BSP
AISI 304
MS7, PS7, BSP
47
25-050027
Inlet pipe 1.1/4"/1.1/2" NPT
AISI 316
MS5, PS1, PS3, PS5
NPT
47
25-050028
Inlet pipe 1.1/2" NPT
AISI 316
MS7, PS7, NPT
48
25-250020
Outlet pipe 1.1/4"/1.1/2" BSP
AISI 304
MS5, PS1, PS3, PS5
BSP
48
25-250021
Outlet pipe 1.1/2" BSP
AISI 304
MS7, PS7, BSP
48
25-250026
Outlet pipe 1.1/4"/1.1/2" NPT
AISI 316
MS5, PS1, PS3, PS5
NPT
Version 9 (02.2018. EN) (MS5, MS7, PS1, PS3, PS5, PS7)
Page 15 of 48
48
25-250027
Outlet pipe 1.1/2" NPT
AISI 316
MS7, PS7, NPT
49
26-100100
Clamping ring fitting 1/2"x4
AISI 303
All
50
26-100121
Vent pipe model 5
AISI 304
MS5, PS1, PS3, PS5
50
26-100131
Vent pipe model 7
AISI 304
MS7, PS7
51
30-740483
Flexi clamps ø48,3
-
MS5, PS1, PS3, PS5
51
30-740761
Flexi clamps ø76,1
-
MS7, PS7
52
06-000315
Pumpe CRNE 3-9 2,2 kW
-
PS1
3x380-500v/50-60Hz
52
06-000600
Pumpe CRNE 3-9 4 kW
-
PS3
3x380-500v/50-60Hz
52
06-000525
Pumpe CRNE 5-14 6 kW
-
MS5, PS5
3x380-500v/50-60Hz
52
06-000005
Pumpe CRNE 10-9 7,5 kW
-
MS7, PS7
3x380-500v/50-60Hz
53
32-000090
Temperature switch 88°C 1/2"NC
AISI 304
All
54
35-411001
Cable 4x1,5mm² CE 3m
-
MS5, PS1, PS3, PS5
3x400V/50Hz
54
35-411011
Cable 4x1,5mm² 3 m AWG16
-
MS5, PS5
3x460V/60Hz
54
35-411000
Cable 4x2,5mm² CE
-
MS7, PS7
3x400V/50Hz
54
35-411010
Cable 4x2,5mm² CSA
-
MS7, PS7
3x460V/60Hz
55
35-600064
Pressure switch 1/8" 0,1-2bar NO
-
All
56
35-700201
Screwed cable connection
Plastic
All
57
35-712498
Multiple packing M25x1,5 4x6,5mm
Plastic
All
58
36-100090
Pressure transmitter 60 bar
-
All
59
36-800015
On/off buttons G5
-
All
60
41-231001
Door 1000mm G5
AISI 304
All
61
42-600047
Hinge for cabinet 1000 mm
AISI 304
All
62
42-600069
Attachment bracket
AISI 304
MS5, PS1, PS3, PS5
62
42-600070
Attachment bracket
AISI 304
MS7, PS7
63
43-100070-01
Wall bracket
AISI 304
All
64
46-023010
Pump bracket 1000 mm G5 IE5
AISI 304
All
65
46-160160
Top plate for MS/AM IE5
AISI 304
All
66
46-401004
Housing 1000mm IE5
AISI 304
All
67
72-000030
Nut for lock
Nylon
All
68
72-000040
Lock with hook
AISI 304/Plastic
All
69
72-000050
Strike plate - All
70
72-100010
Key for housing
Plastic
All
71
35-700200
Cablenut M20x1,5
Brass
All
72
04-000223
Blind plug ø32,5 black
Plastic
PS1, PS3, PS5, PS7
73
04-000012
Blind plug ø15 black
polyethylene
PS1, PS3, PS5, PS7
74
010-200200
Plastic plug ø23xø20mm
Nylon
PS1, PS3, PS5, PS7
Loading...