SystemAir VTK Airvent Installation Instructions Manual

Page 1
Document in original language | · A001
VTK Airvent
Installation instructions
GB
Page 2
| A001
Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications.
Page 3
| A001
Contents
1 Making holes for the duct....... . . . . . . . . . . . . ...............1
2 Mounting ................... . . . . . . . . . . . . ................. . . . . . . 1
3 Function........... . . . . . . . . . . . . ................... . . . . . . . . . . . . ..1
4 Accessories........... . . . . . . . . . . . . .................... . . . . . . . . .2
4.1 Mounting washers....... . . . . . . . . . . . . ...............2
4.2 Filter change . . . . . . . . . . . . .................... . . . . . . . . .2
Page 4
Page 5
Making holes for the duct |
1
1 Making holes for the duct
Drill holes through the inner wall, dimensions according to the table. See image for suitable location.
VTK
ø (mm)
80 85
100 105
125 130
160 165
2 Mounting
1. Cut the duct to adjust to the thickness of the wall
1
2
3
4
2. Mount the duct through the wall and use the fastening lugs to attach the duct with two screws.
3. From the outside, push the wall grid with extension against the wall duct. Use filling material against the outer wall if needed.
4. From the inside, push the airvent into the duct. The gasket keeps the airvent in place, no screws are necessary.
3 Function
VTK has a temperature sensitive and automatic thermostat that regulate the airvent plate and adjust the air gap and al­so the amount of air depending on the outside temperature. The airvent opens less when cold outside. If the airvent is in auto mode the supply of outside air decrease gradually down to -5° C.
When the temperature rises the airvent opens gradually and are fully open at +10° C. The setting can easily be ad­justed. By turning the airvent’s plate from auto position; clockwise if you need it to close earlier or counter clockwise if it should stay slightly open at temperatures under -5° C.
Locknut
Spring
Thermostat bulb
Plate
Valve
Guide notch for auto mode
Condensation insulation
Guide
Stop for locking guide notch
Drive pin
| A001
Page 6
2
|
Accessories
4 Accessories
Filter and accessories are available at www.systemair.com.
4.1 Mounting washers
1. Turn the airvent’s plate counter clockwise from auto mode and detach.
2. Mount the washers to desired gap opening on the guide, add 2 mm (the stud on the washer shall run in the track of the guide).
3. The washers are available in 2 and 4 mm thickness. A 4 mm washer provides 2 mm gap opening. One 4 mm + 2 mm washer provides a 4 mm gap opening.
4. Turn the plate to auto mode.
4.2 Filter change
It is recommended to change the filters between 1-3 years interval depending on placement and air quality.
1. Mount the filter first on the airvent. Ensure that the filter encloses the venting house and the rubber seal.
2. Push the airvent and filter in to the duct.
3. If correctly mounted, the gasket should hold the airvent firmly in the duct, no screws are necessary.
| A001
Page 7
| A001
Page 8
VTK Airvent · Installation instructions · · en_GB · 01-06-2017 · A001
Systemair Sverige AB Industrivägen 3 SE-739 30 Skinnskatteberg, Sweden
Phone +46 222 440 00 Fax +46 222 440 99
www.systemair.com