SystemAir RVF Installation Instructions Manual

Page 1
RVF
Wallfan/Väggäkt
Installationinstructions
Documentinoriginallanguage
200529-EN_GB
06-11-2015A002
Page 2
1English......................................................................................................................................1
1.1DeclarationofConformity..................................................................................................1
1.2Design.............................................................................................................................2
1.3Motorprotection...............................................................................................................2
1.4Maintenance....................................................................................................................2
1.5Ifthefanstops.................................................................................................................2
1.6Assembly.........................................................................................................................3
2Svenska....................................................................................................................................4
2.1Försäkranomöverensstämmelse......................................................................................4
2.2Utförande.........................................................................................................................5
2.3Motorskydd......................................................................................................................5
2.4Underhåll.........................................................................................................................5
2.5Vidfel..............................................................................................................................5
2.6Montering........................................................................................................................6
3Performance/Prestanda..............................................................................................................7
4Wiring/Elschema........................................................................................................................7
Page 3
1English
1.1DeclarationofConformity
Manufacturer
SystemairSverigeAB Industrivägen3·SE-73930SkinnskattebergSWEDEN Ofce:+4622244000Fax:+4622244099·www.systemair.com
herebyconrmsthatthefollowingproducts:
WallfanRVFAC/EC
(Thedeclarationappliesonlytoproductintheconditionitwasdeliveredinandinstalledinthefacilityin accordancewiththeincludedinstallationinstructions.Theinsurancedoesnotcovercomponentsthatare addedoractionscarriedoutsubsequentlyontheproduct).
Complywithallapplicablerequirementsinthefollowingdirectivesregulations
MachineryDirective2006/42/EC
LowV oltageDirective2006/95/EC
EMCDirective2004/108/EC
EcodesignDirective2009/125/EC
1253/2014
Requirementsforventilationunits
Thefollowingharmonizedstandardsareappliedinapplicableparts:
ENISO12100:2010Safetyofmachinery-Generalprinciplesfordesign-Riskassessmentandriskreduction.
EN13857
Safetyofmachinery–Safetydistancestopreventhazardzonesbeingreachedbyupper orlowerlimbs.
EN60204-1
Safetyofmachinery–Electricalequipmentofmachines–Part1:Generalrequirements.
EN60335-1
Householdandsimilarelectricalappliances–SafetyPart1:Generalrequirements.
EN60335-2-80
Householdandsimilarelectricalappliances–SafetyPart2-80:Particularrequirements forfans.
EN60335-2-40
Safetyofhouseholdandsimilarelectricalappliances-Part2-40:Particularrequirements forelectricalheatpumps,air-conditionersanddehumidiers.
EN50106:2007
Safetyofhouseholdandsimilarappliances–Particularrulesforroutinetestsreferringto appliancesunderthescopeofEN60335-1andEN60967.
EN60529
Degreesofprotectionprovidedbyenclosures(IPCode).
EN62233
Measurementmethodsforelectromagneticeldsofhouseholdappliancesandsimilar apparatuswithregardtohumanexposure.
EN60730-1
Automaticelectricalcontrolsforhouseholdandsimilaruse–Part1:Generalrequirements.
EN61000-6-2
Electromagneticcompatibility(EMC)–Part6-2:Genericstandards–Immunityfor industrialenvironments.
EN61000-6-3
Electromagneticcompatibility(EMC)–Part6-3:Genericstandards–Emissionstandards forresidential,commercialandlight-industrialenvironments.
Thecompletetechnicaldocumentationisavailable.
Skinnskatteberg,06-11-2015
MatsSándor TechnicalDirector
RVF
Installationinstructions
200529
1
SystemairSverigeAB
Page 4
1.2Design
RVFisanexhaustfanmeantforoutsidewallmounting.Ithasanasynchronousexternalrotormotorwith backwardcurvedimpellersandsealedballbearings.
Thecoverismadeofgalvanizedsteelsheet,powdercoatedwhite.
1.3Motorprotection
Motorprotectionisintegratedintheelectronicsofthemotor .Incaseofoverheatingthemotorwillstop automaticallyuntilitscooleddown.
1.4Maintenance
Warning
Alwaysturnoffthepowerbeforecleaningormaintenance.
Theelectricalinstallationmustbecarriedoutbyaqualiedelectrician.
Thefanmotordoesnormallyrequireanymaintenance.However,itisnecessarytocleantheimpellera leasttwiceayear.
1.5Ifthefanstops
Warning
Makesurethatthepowerisoff!
Removethefancasing.Checkthattheimpellerisnothinderedbydustordebris.
Ifthefandoesnotstartagain,contactthesupplier.
RVF
Installationinstructions
200529
2
SystemairSverigeAB
Page 5
1.6Assembly
1.Removethecasingbyunscrewingthescrewsonitsside.
2.
Connectthefantoaductwhichislongenoughtogothroughtheouterwall.
3.
Makeaholeinthewallfortheductandelectriccable.
4.
Pushtheductandcablethroughthewallfromtheoutside
5.
Assemblythefanontothewallandreplacethecover.
6.
Theelectricinstallation(permanentassembly)mustbecarriedoutbyaqualiedelectrician.
Thefanmustbeprecededbyanall-poleswitchwithatleast3mmbreakinggap.
RVF
Installationinstructions
200529
3
SystemairSverigeAB
Page 6
2Svenska
2.1Försäkranomöverensstämmelse
Tillverkare
SystemairSverigeAB Industrivägen3·SE-73930SkinnskattebergSVERIGE Tel:022244000Fax:022244099·www.systemair.com
intygarhärmedattföljandeprodukter:
VäggäktRVFAC/EC
(Intygetgällerendastförproduktenidetskickivilketdenlevereratsochinstalleratsvidanläggningeni enlighetmedmedföljandeinstallationsanvisningar.Intygetomfattarintekomponentersomsenarelagtstill elleråtgärdersomsenarevidtagitspåprodukten).
Uppfyllerallatillämpligakravinedanståendedirektiv
Tillämpligadelaravnedanståendeharmoniseradestandardertillämpas.
Maskindirektivet2006/42/EG
Lågspänningsdirektivet2006/95/EG
EMC-direktivet2004/108/EG
EcodesignDirektivet2009/125/EC
1253/2014
Kravförventilationsaggregat
ENISO12100:2010Maskinsäkerhet–Generellakonstruktionsprinciper–riskbedömningochriskminskning.
EN13857
Maskinsäkerhet–Skyddsavståndföratthindraattarmarochbennåriniriskområden.
EN60204-1
Maskinsäkerhet–Maskinerselutrustning–Del1:Allmännafordringar.
EN60335-1
Elektriskaapparaterförhushållochliknande–Säkerhetdel1:Allmännafordringar
EN60335-2-80
Elektriskahushållsapparaterochliknandebruksföremål–Säkerhet–Del2-80:Särskilda fordringarföräktar .
EN60335-2-40
Elektriskahushållsapparaterochliknandebruksföremål–Säkerhet–Del2-40:Särskilda fordringarpåelektriskavärmepumpar,luftkonditioneringsapparaterochavfuktare.
EN50106:2007
Elektriskahushållsapparaterochliknandebruksföremål–Säkerhet–Anvisningarför tillverkningskontrollavapparatersomomfattasavEN60335-1ochEN60967.
EN60529
Kapslingsklasserförelektriskmateriel(IP-beteckning).
EN62233
Hushållsapparaterochliknandebruksföremål–Mätningavelektromagnetiskafältmed avseendepåexponering.
EN60730-1
Automatiskaelektriskastyr-ochreglerdonförhushållsbruk–Del1:Allmännafordringar.
EN61000-6-2
Elektromagnetiskkompatibilitet(EMC)–Del6-2:Allmännanormer–Immuniteti industriellamiljöer.
EN61000-6-3
Elektromagnetiskkompatibilitet(EMC)–Del6-3:Allmännanormer–Emissionsnivåerför hushåll,handelochlättindustri.
Fullständigtekniskdokumentationnnstillgänglig.
Skinnskatteberg,06-11-2015
MatsSándor Tekniskdirektör
RVF
Installationinstructions
200529
4
SystemairSverigeAB
Page 7
2.2Utförande
RVFärenfrånluftsäktsomskamonteraspåhusetsyttervägg.Fläktenharenkortslutenasynkronmotor avytterrotortypmedbakåtböjdaskovlarochkapsladekullager.
Denärförseddmedenskyddandekåpaavpulverlackeradgalvaniseradplåt.
2.3Motorskydd
Motorskyddärintegreratimotornselektronik.Ommotornbliröverhettadstannarmotornautomatiskt tillsdenharkyltsner.
2.4Underhåll
Varning
Brytalltidströmmeninnanrengöringochservice.
Fastelinstallationfårendastutförasavbehöriginstallatör.
Fläktendrivsavenmotorsomintekrävernågotdirektunderhåll.Detärdocknödvändigtattrengöra äkthjulet,minstengångperårelleroftarevidbehov.
2.5Vidfel
Varning
Setillattströmmenärbruten!
Tabortäktkåpan.Kontrolleradärefterattäkthjuletinteärblockerat.
Omäktenintestartarigen,kontaktaleverantören.
RVF
Installationinstructions
200529
5
SystemairSverigeAB
Page 8
2.6Montering
1.
Lossaskruvarnapåäktkåpanssidorochtabortkåpan.
2.
Anslutäktentillenkanalsomärminstlikalångsomytterväggendenskagåigenom.
3.
Göretthåliväggenförkanalochelkabel.
4.
Förinkanalenochelkabelnfrånutsidanavväggen.
5.
Monterafastäktenpåväggenmedskruvarnaochsätttillbakaäktkåpan.
6.
Såkalladfastelinstallationfårendastutförasavbehöriginstallatör .
Fläktenmåsteföregåsavenallpoligbrytaremedminst3mmbrytaravstånd.
RVF
Installationinstructions
200529
6
SystemairSverigeAB
Page 9
3Performance/Prestanda
RVFACRVFEC
4Wiring/Elschema
RVF100ACRVF100EC
RVF
Installationinstructions
200529
7
SystemairSverigeAB
Page 10
lastpage
SystemairSverigeABreservestherighttomakechangesandimprovementstothe
contentsofthismanualwithoutpriornotice.
SystemairSverigeAB
Industrivägen3
SE-73930Skinnskatteberg,Sweden
Phone+4622244000
Fax+4622244099
www.systemair.com
200529