Contents
1Declaration of Incorporation........ ..... ......... ..... ....1
2General information ..... ..... ..... ......... ..... ..... ..... ..2
12 Disturbances and troubleshooting .... ..... ......... ... 21
|
1Declaration of Incorporation
Declaration of Incorporation |
1
|
| General information
2
2General information
2.1Notice symbols
Danger
Direct hazard
Failure to comply with this warning leads directly to death or to serious bodily harm.
Warning
Potential hazard
Failure to comply with this warning possibly leads to death or serious bodily harm and damage to objects.
Caution
Hazard with a low risk
Failure to comply with this warning may potentially lead to moderate injuries or/and damage to objects.
Important
Hazard with risk of damage to objects
Failure to comply with this warning will lead to damage to objects.
Note:
Useful information and instructions
2.1.1Instruction symbols
Instruction
♦ Carry out this action
♦ (if applicable, further actions)
2.2Notes on the documentation
Warning
Hazard as a result of improper handling of the fan
These operating instructions describe the safe use of the fan.
♦ Read the operating instructions completely and carefully!
♦ Keep the operating instructions and other valid documents, such as the circuit diagram or motor
instructions, with the fan. They must be permanently available at the place of use.
Instruction with xed sequence
1. Carry out this action
2. Carry out this action
3. (if applicable, further actions)
3Warnings
The following admonitions will be presented in the different sections of the document.
Danger
• Make sure that the Mains supply to the unit is disconnected before performing any maintenance or
electrical work!
• All electrical connections must be carried out by an authorized installer and in accordance with local rules
and regulations.
|
Product information |
Warning
• Keep the doors locked during operation to ensure required level of safety for the unit.
• The unit must be duct connected or in some other way provided with protection so that it is not possible
to come in contact with the fans through the duct connections
• Beware of hot surface an the heating battery during maintenance and service.
• The unit is heavy. Be careful during transport and mounting. Risk of injury through pinching. Use
protective clothing
• Beware of sharp edges during mounting and maintenance. Make sure that a proper lifting device is used.
Use protective clothing.
• The units electrical connection to the mains supply must be preceded by an all pole circuit breaker with a
minimum 3 mm gap.
Caution
• If the unit is installed in a cold place make sure that all joints are covered with insulation, and tape well
• Duct connections should be covered during storage and installation
• Do not connect tumble dryers to the ventilation system
• Take care not to damage the water battery when connecting water pipes to connectors. Use a spanner to
tighten the connection.
3
4Product information
4.1General
This installation manual concerns air handling unit type MAXK-I3 DC.
• Wall thickness: 50mm. T3/TB3 (DIN EN 1886) casing T2/TB2 or T1/TB1 on request
The MAXK-I3 DC series is a passive house certified air handling unit. The air handling units with heat recovery consists
of a counter flow plate heat exchanger with integrated bypass, supply and exhaust air fan with EC motor and an outdoor- and extract air filter. Six sizes in modular design with extendible accessories like damper, recirculating air damper,
heater modules, cooling modules and silencer. This manual consists of basic-information and recommendations concerning the design, installation, start-up and operation, to ensure a proper fail-free operation of the unit. The key to
proper and safe operating of the unit is to read this manual thoroughly, use the unit according to given guidelines and
follow all safety requirements.
658 x 638976 x 6381456 x 6381756 x 6382136 x 6382456 x 638
Also suitable for application in residential construction
Also suitable for application in residential construction
Counter flow plate heat exchanger
Direct current (EC technology)
|
Transport and storage |
5
Total weight
without heating
battery
Total weight with
heating battery
* with built in filters (outdoor air F7 and extract air M6).
Additional installed units such as, for example, heating battery reduce the available external pressure
kg
kg
88010001200139016201840
95610931330152117922031
4.5Acoustics
MAXK-I3 DC
2000 DC
3000 DC
4000 DC
5000 DC
6000 DC
7000 DC
* Operation at the upper limit.
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
dB(A)
Sound level*
Casing
63,779,260,358,678,4
64,875,268,668,675,2
65,880,473,373,380,4
66,782,376,376,382,3
67,980,774,374,380,7
63,678,363,661,879,6
Supply air
Extract air
Outdoor airExhaust air
5Transport and storage
5.1General
MAXK-I3 DC air handling units are delivered in transport
units. The width of the lorry (inside width approx. 2,34 m
) resp. loading level (inside width approx. 2,55 m – width
for a jumbo approx. 2,9 up to 3,05 m ) determine the
quantity of the single parts.
Note:
The quantiy of the single parts is shown in the
detailed drawing.
Important
• The shaft of the ventilator must always be arranged horizontally during the transport
• Units for outdoor installation with weather roof: weights without snow load!
Warning
• The unit is heavy. Be careful during transport and installation. Risk of injury through pinching. Use
protective clothing.
• The unit must not be put into operation before the enclosed parts are removed and installed properly.
|