DGeneral descriptions, dangers and warnings
EDrawings, diagrams, guides and instructions for the use, maintenance and repair
FEmployees in charge of operation/control/maintenance
GIntended use and range of applications
HUnintended use and misuse – inappropriate applications for the machine
Installation
IInstructions for unloading on the site as well as installation and connection
JInstallation and assembly instructions for reduction of noise and vibration emissions
Start-up, adjustments and operation
KStart-up, adjustments, use, commissioning and unit in hipernation
LInformation about the residual risks
MInstructions on the protective measures during repair and maintenance
NThe essential characteristics of tools which may be fitted to the machinery
Machine stability
OThe conditions of stability during use, transportation, assembly, dismantling when out of service
PInstructions for machinery where these are regularly to be transported
Breakdown
QThe operating method to be followed in the event of breakdown. Safe restart.
Maintenance
RAdjustment and maintenance operations
SInstructions to enable adjustment and maintenance safely
TThe specifications of the spare parts to be used, when these affect the health and safety of operators
Noise
UInformation on airborne noise emissions exceeding 70 dB(A)
Annexes
1Declaration of conformity with production number (in separate cover)
2Technical data – unique data for every unit (in separate cover)
3Spare part list (in separate cover)
4Assembly of base frame – height 118 mm for unit sizes 10 – 18
5Assembly of base frame – height 118 mm for unit sizes 20 – 31
6Assembly of base frame – height 218 mm for unit sizes 10 – 18
7Assembly of base frame – height 218 mm for unit sizes 20 – 31
8Installation of steel roof in the sizes 10 – 31
9Speed control for rotor and assembly of divided rotor
10 Reversible heat pump unit (in separate cover, if heat pump was delivered)
11 Menu for internal controller in the heat pump unit (in separate cover, if heat pump was delivered)
12 Connection of fan motor and set-up manual for frequency converter
13 Commissioning protocol – proposal (in separate cover)
14 Report with data from final functional test on the Systemair factory (in separate cover, if control system was
delivered)
15 Short description of main components in the control system
16 Wiring diagram (in separate cover, if control system was delivered)
17 Operator’s guide (how to use the Systemair control panel) (in separate cover, if control system was delivered)
This User Manual covers all air handling units with control system delivered by Systemair A/S.
Manufacturer and supplier data:
Systemair A/S
Ved Milepælen 7
DK-8361 Hasselager
Responsible for documentation: Ulf Bang
BName of machines
This manual is about Systemair air handling units called Geniox 10, Geniox 11, Geniox 12, Geniox 14, Geniox 16, Geniox
18, Geniox 20, Geniox 22, Geniox 24, Geniox 27, Geniox 29 and Geniox 31.
1
output |
| Declaration of Conformity - example
2
CDeclaration of Conformity - example
The manufacturer:
Systemair A/S
Ved Milepælen 7
DK - 8361 Hasselager
Hereby declares that, air handling units of the flowing types:
are manufactured and delivered in accordance with following directives:
Machinery directive 2006/42/EC
Ecodesign — Commission regulation 1253/2014
EMC – directive 2014/30/EC
Low voltage directive 2014/35/EC
Pressure equipment directive 2014/68/EC
European Standard EN378–1 & 2 — 2016
Equipment type: Heat Pump Unit — Geniox and DVU Series
Consisting of: Compressor, evaporator and condenser
Verification and Assessment by:
Notified Body Bureau VERITAS CE0041 for PED
Bureau VERITAS UK, “Parklands”, Wilmslow Road
Didsbury, Manchester M20 2RE
The declaration is only valid, if the installation of the air handling unit is carried out according to the instructions delivered with the unit. The installer will be responsible for the CE marking and documentation, if any construction or functional changes are applied to the air handling unit.
Geniox air handling units are order specific machines available in thousands of different configurations. Only a few examples of machine configurations are described below. The air handling units are intended for the transport and treatment of air between -40 °C and + 40 °C.
The units are exclusively for comfort ventilation.
Maintenance of the units must be carried out by skilled technicians.
On the drawing below, a right hand unit is shown because the inspection doors are mounted on the right hand side of
the unit when looked in direction of SUPPLY airflow. The unit below is with rotary heat exchanger.
3
Position
A
B
C
D
Description
Connection, supply air (to the rooms)
Connection, exhaust air
Connection, outdoor air in
Connection, extract air (from the rooms)
D.1Overview via pictograms on the inspection side of the unit
Symbol
D.1.1Where are pictograms placed on the units
Example (Pictograms and labels with descriptions of functions for fast identification)
PositionDescription
1
2
output |
At each section a label with production number of this air handling unit as well as weight of
each section
Machine card
Symbol
| General descriptions, dangers and warnings
4
PositionDescription
3
4
5
6
7
8
9
10Damper – extract air
Damper - supply air
Filter - supply air
Fan- supply air
Heating battery - supply air
Fan - extract air
Heat exchanger
Filter – extract air
Symbol
11
Integrated control system in a cabinet behind this inspections door.
D.1.2Weight of each section and production number – example for the Geniox unit
Weight of the section. Production number of the unit.
Number of the section in the unit.
Product name in this example Geniox 27SL, where 27 indicates the size of the unit. The unique production number for the complete unit in this example is 1712–
0004601640–10 where 17 indicates production year
2017 and 12 indicates month.
D.1.3CE label — example for the Geniox unit
CE marking is printed on the machine card.
output |
General descriptions, dangers and warnings |
D.1.4Pictograms for all available functions in the units
5
Id
GenioxADamper
GenioxBDamper
GenioxM
GenioxP
GenioxG
GenioxF
Description
Damper for mixing
Damper for mixing
Panel filter
Bag filter
Symbol
GenioxC
GenioxQ
GenioxR
GenioxH
GenioxK
GenioxUHeat pump unit
Rotary heat exchanger
Plate heat exchanger (cross flow and counter flow)
Run around heat exchanger
Heating battery
Cooling battery
GenioxE
output |
Plug fan
| General descriptions, dangers and warnings
6
Id
GenioxD
GenioxX
Description
Silencer
Humidifier
D.1.5Pictograms about warnings and dangers on the units
Pictograms according to EN1886 about
Warning
Warning about danger by rotating parts
Warning
Warning about danger by electricity
Warning
Warning about danger by heat
Symbol
D.2Data about the unit according to cards and labels in and on the unit
D.2.1Machine card with unique data on every unit
output |
D.2.2Label with data about the cabinet — example.
An example of the label that is always placed on or with
the cabinet
Systemair A/S
Systemair declares hereby that the cabinet is in
conformity with:
SBB Low voltage panels:
Electrical material on machines:
EMC-directive environment:89/336/EOF
Diagram versionGeniox ver. X:XX
Systemair order number
Unit size10
Cabinet data:
System ground
Current typeAC
Frequence50 HZ
Rated voltage
Control voltage
PSCC max
PSCC min650 A
Max fuse
Min fuse
Cable colors:
Protection circuit
230 VAC phaseBlack
0 VAC neutralBlue
24 VDCGrey
0 VDCGrey
Analog/digital
General descriptions, dangers and warnings |
N60439-1
EN60204-1
72800-1
TN-S
3*400 V+N+PE VAC
24 VDC
6 kA
25
10
Green/yellow
Grey
7
D.2.3Flowchart – example of the label placed on or with the cabinet
output |
| General descriptions, dangers and warnings
8
D.2.4Symbols in the flowchart and explanation about the symbols
Id
TTemperature sensor - PT1000
M
MDamper motor – 0-10V
P
PPressure transmitter – 0-10V
Description
Damper motor — on/off
Filter guard - digital
Symbol
RH
CO2
M
Sensor for relative humidity – 0-10V
Sensor for CO2 – 0-10V
Controller and drive motor for rotary heat exchanger – 0-10V
output |
General descriptions, dangers and warnings |
D.2.5Example of label placed on or with the cabinet – Terminal plan for external
components
9
D.3Hand terminal
The hand terminal is delivered in a cardboard box containing the other external components. This cardboard box is usually, but not always, placed in the section with the supply air fan. The Operator’s Guide for the hand terminal is the Annex 17 attached to this – User Manual.
Important
All LEDs on the hand terminal must be off before startup of the unit.
1. ALARM: Press for alarm list
2. Alarm LED – red light for alarm
3. LED indicating change of parameters
4. OK/ENTER
5. Press for clear
6. Press for move of curser in menu
D.4Dimensions of the units
See Annex 2 with information about the exact dimensions.
output |
| Drawings, diagrams, guides and instructions for the use, maintenance and repair
10
D.5Ordinary automatically operation – only manual operation by new parameters
The unit is operating fully automatically and manual operation includes only selection of new parameters via the buttons on the hand terminal. The hand terminal is connected by a cable to the controller in the cabinet. 10 meters of cable
is delivered with the unit and the customer has the possibility to replace this cable with an identical type of cable that is
up to 100 meters long. The alternative is that the controller is connected to a BMS system with the ability to select new
parameters via PC, tablet or SmartPhone.
D.6Warnings about dangers
Pictograms according to EN1886 about
Warning
Warning about danger by rotating parts
Warning
Warning about danger by electricity
Warning
Warning about danger by heat
Warning
Disregards of instructions shown on warning signs are connected by risk for injury or damage on material.
EDrawings, diagrams, guides and instructions for the use, maintenance and
repair
All Geniox units with integrated control system are manufactured in compliance with the EC Declaration of Conformity
and they are CE marked as machines. Unique Declaration with production number of the machine is an integral part of
the machine – enclosed as Annex 1to this manual. If the buyer carries out changes or adds components in or on the machine, the buyer must issue a new EC Declaration of Conformity and a new CE marking of the machine.
To promote correct use of the machines, the below-mentioned instructions are an integral part of the machine:
• Unique drawings, data and description of functions for the delivered unit – Annex 2
• Wiring diagrams – Annex 16
• Operator’s Guide – Annex 17
• Instructions for use of the machine – chapter K in this manual
• Instructions about adjustment and maintenance – chapter R in this manual
• Safety during adjustment and maintenance – chapter S
FEmployees in charge of operation/control/maintenance
The units are constructed and built with a fully integrated control system. After start-up and hand-over from installer to
operators, the unit operates fully automatically.
Indications of operating status as well as indication of faults are visible in the display and on the LEDs at the hand terminal. The operators can enter new parameters in the controller via the buttons on the hand terminal. Alternatively, the
controller can be connected to a BMS system so that new parameters can be selected via PC, tablet or Smartphone.
The operators do not need to open inspections doors for the operation.
Skilled technicians must carry care out maintenance as well as repairs.
GIntended use and range of applications
The air handling units are intended for the transport and treatment of air between -40 °C and + 40 °C The units are exclusively for comfort ventilation. The units are not for environments that exceed the corrosion class C4 according to EN
ISO 12944-2.
Intended applications for the units are:
output |
Unintended use and misuse – inappropriate applications for the machine |
• Offices
• teaching rooms
• hotels
• shops
• homes and similar comfort zones
HUnintended use and misuse – inappropriate applications for the machine
Units for outdoor installation must be specified and ordered for outdoor installation. The units must not be used in environments that exceed corrosion class C4 according to EN ISO 12944-2, and for transport of solid particles.
Examples of not intended use:
• Kitchen extraction
• swimming pools
• off-shore
• Ex-areas
• drying of washed clothes.
• Do not use the unit with partly finished duct systems.
• Do not use the unit for ventilation of the building site until the unit is properly provided with guards.
11
H.1Air handling unit in operation
The pressure difference between interior and exterior of the unit must not exceed 2000 Pa for the Geniox 10 and up to
Geniox 31 (including Geniox 31), and 1500 Pa for Geniox 36 and Geniox 44.
Before start-up of the unit all ducts, safety guards and all protective devices must be mounted to prevent any access to
rotating fan impellers. All inspection doors must be closed and locked when the unit is in operation.
Do not use the unit without filters.
IInstructions for unloading on the site as well as installation and connection
I.1Unloading on the site
The air handling unit – AHU - is delivered as one section or in several sections, which are to be assembled on site. The
AHU is delivered on transport pallets, legs or on a base frame. Loading and unloading as well as transport on the site is
possible by fork-lift truck or by crane using suitable lifting straps.
I.1.1Unloading by fork-lift truck
The forks of the truck must be sufficiently long to avoid any damage to the AHU underside.
output |
| Instructions for unloading on the site as well as installation and connection
12
I.1.2Unloading by crane
AHU delivered on transport pallet must be lifted by straps as shown in the illustration.
I.1.3Transport of unit without base frame on the site
Units without base frame are always delivered in sections with each section on a pallet. Sections can be transported on
the site by hand manual forklifts.
I.1.4Lifting a unit with straps
Use an appropriate lifting beam with a sufficient span to avoid that the straps touch and damage the drip nose profiles
and the inspection side with handles, pipes and accessories – for example manometers, cabinets, tabs for measuring
the pressure.
I.1.5Lifting a unit with preinstalled brackets on the base frame for lifting.
Lifting beam and straps are not included in the delivery.
I.1.6Lifting a unit without base frame and legs but with preinstalled brackets for lifting.
Attach straps carefully to the 4 brackets at the bottom of sections on Geiniox units sizes 20 — 31, because those brackets are mounted to the profiles that are bearing the heavy components in the section
output |
Instructions for unloading on the site as well as installation and connection |
This type of bracket at the bottom of Geniox units in the
sizes 20 to 31 is reinforced for lifting the unit. Mount a
shackel in each of the 4 brackets that should be suitable
for lifting the weight of the section. The weight of the
section is printed on the label placed on the inspection
side of the unit.
13
Caution
Do not lift the section in the 4 brackets at the top of the section, because those brackets are not mounted
on profiles that are bearing. The connection between these profiles at the top of the section is not designed
to lift the bottom of the section with the heavy components. There is a potential risk that the bottom with
the heavy components may fall down with serious risk of injury and damage to property.
Bracket at the bottom for lifting and assembling Geniox
units in the sizes 20 — 31
output |
| Instructions for unloading on the site as well as installation and connection
14
Look at the backside of the bracket for lifting and assembling Geniox units in the sizes 20 — 31. Check that each
of the 4 brackets is mounted on the horizontal profiles by
screws with M6 mm thread and on the vertical profiles by
6 mm tap tights. Only brackets that are mounted in this
way are suitable for lifting.
This bracket at the bottom of Geniox units in the sizes 16
and 18 is not reinforced for lifting the unit. Furthermore,
this bracket is not firmly fastened for lifting the section.
This bracket is only for the assembly of sections.
I.1.7Roof unit with PVC roof
Avoid damaging the drip nose profiles along the PVC roof. Keep the protection profiles of Styrofoam on the unit until
the installation has been completed. If the unit is lifted by straps, the straps must be kept away from the drip nose profiles by bars to avoid damage to roofing profiles.
output |
Instructions for unloading on the site as well as installation and connection |
I.1.8Roof unit with steel roof
Caution
For units with steel plate roof, the steel plates are delivered uninstalled on a separate pallet. Do not step or
walk on the plates.
15
I.1.9Pre-assembly storage
The AHU must be protected from the weather and accidental impact. Plastic packaging must be removed and the unit
covered with tarpaulin or similar materials. In order to minimize condensation, sufficient air circulation must be ensured
between the covering and the unit.
I.1.10Tilt less than 30˚ during transportation of the section with heat pump
During transportation, the unit section must always be in the upright position or tilted less than 30˚. If it is necessary to
tilt the unit more than 30˚, the suction pipe of the compressor must point upwards to prevent the escape of oil from the
compressor sump.
I.1.11Transport of rotary heat exchanger — always in vertical position
During transportation, the unit section must always be in the upright vertical position and never in a horizontal or tilted
position. The rotary heat exchanger is not constructed for transportation in a horizontal or tilted position.
I.2Installation - mechanical
I.2.1Free area in front of and above the unit
Important
When positioning the unit on the site, it must be ensured that an area with the same width as the unit is
kept free for service and inspection and also for replacement of fans and exchanger, if needed. The width of
the free area must be at least 900 mm.
output |
Important
For safe access to the cabinet with electrical components, if the cabinet is placed on top of the unit, the free
area from the upper edge of the cabinet to the ceiling must be at least 700 mm.
| Instructions for unloading on the site as well as installation and connection
16
I.2.2Supporting surface
Caution
Duct work must be sound insulated and must not be mounted directly on beams, trusses or other critical
building parts.
Caution
The surface beneath the unit must be level, horizontal and vibration-free. The surface must be able to
withstand the load of the AHU. Weights of the sections are written in Annex 2.
I.2.3Adjustable feet under legs or base frame and transport of sections
Adjustable feet are provided in a carton box placed inside the unit. Adjustable feet are delivered for indoor units and
not for outdoor units.
Sections can be transported on the site by hand manual forklifts or similar. The frame profiles in the edges of the sections have carrying capacity for lifting by the hand manual forklifts.
I.2.4Base frame assembly
Base frame is delivered unassembled for the indoor units that are delivered in sections on pallets. Assembly of the base
frame is illustrated on 4 pages in a manual in a plastic bag which is attached to one of the large base frame parts.
The 4 pages with the illustration regarding the assembly of the base frame are also available in this user manual in Annex 4, 5, 6 or7.
There are two types of base frames:
1. 118 mm high base frames
2. 218 mm high base frames
There are 4 different manuals and each of them illustrates the assembly of the 4 different types of base frames:
1. Manual about the 118 mm high base frames for AHUs in the sizes from Geniox 10 to Geniox 18. The name of this
manual is – Base frame 118 sizes10 - 18
2. Manual about the 118 mm high base frames for AHUs in the sizes from Geniox 20 to Geniox 31. The name of the
manual is – Base frame 118 sizes20 - 31
3. Manual about the 218 mm high base frames for AHUs in the sizes from Geniox 10 to Geniox 18. The name of the
manual is – Base frame 218 sizes10 - 18
4. Manual about the 218 mm high base frames for AHUs in the sizes from Geniox 20 to Geniox 31. The name of the
manual is – Base frame 218 sizes20 - 31
Mount adjustable feet with a distance of maximum 1500 mm between each foot under the base frame. The base frame
can now be levelled by the adjustable feet. The next step is to place and assemble AHU sections on the base frame.
I.2.5Base frames for outdoor units
Outdoor units must be installed on 218 mm high base frames and are always fitted to the AHU sections. Hot-dip galvanized base frames are recommended for outdoor units. Systemair delivers these base frames without the above mentioned adjustable feet.
I.2.6Outdoor units — support under the base frame of the unit
The installer must provide a frame that supports the base frame of the unit under the inspection side and under the
back side of the unit. The frame must support the base frames of the unit under the entire length of the unit.
output |
Instructions for unloading on the site as well as installation and connection |
Caution
To avoid that the unit may tilt during storm the base frame of the unit must be properly fastened to the
frame provided by the installer
I.2.7Installation on the site of unit sections at the base frame when sections are
delivered on pallets
17
Caution
It is strictly forbidden to lift a section under the top of the section. The plastic corners and brackets are not at
all reinforced for lifting the unit under the top. There is serious danger that the bottom with the heavy
components will fall down with the risk of serious injury and damage to property.
Lift up the section by hand manual forklifts to the level where the underside of the section is even with the overside of
the base frame.
Pull the section to the correct position on the base frame
by lifting straps – it is maybe necessary to support the
section by heavy duty furniture trolleys (see the photos
below)
Example of heavy duty furniture trolley turned with the
wheels upwards. Placed in this way on the forks of the
hand manual forklifts the heavy duty furniture trolleys are
suitable for safe and careful rolling of the unit sections
over the base frames.
output |
| Instructions for unloading on the site as well as installation and connection
18
Example of very heavy duty furniture trolleys. Turned
with the wheels upwards and placed on the forks of hand
manual forklifts these heavy duty furniture trolleys are
very suitable for safe and careful rolling of the unit sections over to the base frames.
Pull sections together with a strap. We recommend the
shown type of strap because this type is not damaging
the frame profiles in the bottom of the units. An example
of strap is shown to the right. Note! Do not place the
strap on the vertical profiles because the plastic corners
and the profiles are not at all reinforced for the heavy
load and stress that is created by the tensioner when a
section is pulled along the base frame. To avoid any load
and stress on the plastic corners the strap must be carefully placed on the bottom profiles of the unit when sections are pulled together.
Note! Never — place the strap on the vertical profile too close to a corner, because the plastics corners and the profiles are not at all reinforced for the heavy load and stress created by the tensioner when a section is pulled along
the base frame or on the floor.
output |
Instructions for unloading on the site as well as installation and connection |
Place the strap on the bottom profiles of the unit to avoid any load and stress on the vertical profiles when sections are
pulled together along the base frame. The sections must be pulled fully and tight together with the strap is placed on
the bottom profiles. Do not pull and slide a section unless the strap is placed on the bottom profile.
19
When the sections are pulled fully together it may be helpful to place the strap halfway up on the unit to press the sections fully together so that the rubber seals are closing 100% tight. Only gentle tension is allowed because the vertical
profiles are not reinforced for brutal stress in this direction and they may be bent.
output |
| Instructions for unloading on the site as well as installation and connection
20
Sections are mounted to base frames with self-drilling screws. In the base frame you will find a sufficient number of 5
mm holes that are prepared for the self drilling screws. In this picture you are standing and you are watching the assembled base frame on the floor or roof.
Use self-drilling screws — 4,8 X 18 mm — to be screwed upward through the holes into the bottom profile of the air
handling unit Note! A screw must be placed in every hole to achieve the necessary strength. In this picture you are lying on the floor or roof looking upward under the base frame. The screws will not be visible, when you are standing beside the unit looking at the unit
I.2.8Joining the AHU sections
The sections must be placed on the base frame and if the unit is delivered with 150 mm legs, the sections must be positioned directly in line with each other.
Ensure that the internal factory-fitted rubber sealing is undamaged
output |
Instructions for unloading on the site as well as installation and connection |
The sections are then to be positioned directly opposite
each other. If the sections are built with legs, the adjustable feet can be used to get the sections in line and at the
same height.
Press the sections hard together so that the rubber profiles are so flat that the iron frames of the two sections
are joined. Strap with tensioner is suitable for pressing
the sections hard together.. Note! Do not place the strap
on the vertical profiles because the plastics corners and
the profiles are not at all reinforced for the heavy load
and stress created by the tensioner. To avoid any load
and stress on the plastic corners and the profiles the
strap must be carefully placed on the bottom profiles of
the unit.
21
The sections must then be locked permanently together
with 8 mm bolts and nuts. Bolts and nuts are not delivered from Systemair
output |
| Instructions for unloading on the site as well as installation and connection
22
Assembly is done sucesfully
Bracket inside the unit for assembly of Geniox unit sections in the sizes 16 and 18
Bracket inside the unit for assembly of Geniox unit sections in the sizes 20 to 31
I.2.9Fitting the ductwork
Flexible duct connections between AHU and ductwork must always be installed. Be sure that flexible duct connections
are almost fully stretched. (Flexible connections are ordered as accessories and they are placed inside the unit). At the
fan outlet on a centrifugal fan, the duct size should be as close to the outlet size as possible. Avoid blockage and turbulence at the fan outlet.
output |
Loading...
+ 82 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.