![](/html/35/3586/3586a1c81064c8c540bdd17ca660f85023a8ee7b574c0ac153d9f7426568873e/bg1.png)
Installation and Operation Manual
Manuel d'installation et d'opération
Rn4EC
Inline EC Radon Fan
Ventilateur pour radon en ligne EC
Item #: 142001
Rev Date: 2018-05-02
Technical / Customer Support:
Support technique et service à la clientèle
United States Tel.: 800.747.1762 Canada Tel.: 800.565.3548
![](/html/35/3586/3586a1c81064c8c540bdd17ca660f85023a8ee7b574c0ac153d9f7426568873e/bg2.png)
2
Note Warning / Important note
Avertissement / Note
Information Technical information
Information technique
Practical tip
Conseil pratique
importante
DO NOT CONNECT POWER SUPPLY until fan is completely installed.
Make sure electrical service to the fan is in the locked “OFF” position.
1. Fantech recommends installation of this product by a trained, licensed, certified mitigation professional. Incorrect installation will void any and all
product warranties or liability. Verification of safe/acceptable radon levels after installation is required.
Check your local code restrictions for additional safety measures that may be needed for proper code compliant installation.
2. This fan has rotating parts and safety precaution should be exercised during installation, operation and maintenance.
3. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS - OBSERVE THE FOLLOWING:
a. Use this unit in the manner intended by the manufacturer. If you have any questions, contact your manufacturer’s representative or contact us
directly.
b. CAUTION: Before installation, servicing or cleaning unit, switch power off at service panel and lock the service disconnection means to prevent
power from being switched on accidentally. When the service disconnection means cannot be locked, securely fasten a prominent warning
device, such as tag, to the panel.
c. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-
rated construction.
d. The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the
American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities.
e. When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities.
f. Ducted fans must always be vented to the outdoors.
4. WARNING! Check voltage at the fan to see if it corresponds to the motor name plate.
5. For radon mitigation use only. DO NOT use to exhaust hazardous or explosive materials and vapors.
6. Do not use this fan with any solid state speed control device.
GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN (7) FEET OF WORKING LEVEL OR WHEN DEEMED ADVISABLE
FOR SAFETY.
The ducting from this fan to the outside of the building has a strong effect on the air ow, noise and energy use of the fan. Use the
shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated
air ow.
fantech
![](/html/35/3586/3586a1c81064c8c540bdd17ca660f85023a8ee7b574c0ac153d9f7426568873e/bg3.png)
DIMENSIONS
3
A
C
D
E
Model/
Modèle
Rn4EC-3 5 7/8 (149) 11 1/2 (292) 1 1/4 (32) 9 1/4 (235) 4 (102) 3 1/2 (89) 6 (152)
Rn4EC-4 5 7/8 (149) 11 1/2 (292) 1 1/4 (32) 9 1/4 (235) 4 (102) 4 1/2 (114) 6 (152)
Dimensions in inches (mm).
Dimensions en pouces (mm)
INSTALLATION
A B C D E F G
WIRING DIAGRAM
F
To reduce fan speed use a small screwdriver and turn
The Rn4EC-3 is designed for use with 3" schedule 40 PVC pipe.
potentiometer knob counter clockwise
The Rn4EC-4 is designed for use with 4" schedule 40 PVC pipe
Prior to installation, the suction pipe should be terminated at the exterior
10
wall. The suction pipe should be installed with slight incline to drain water
from the fan.
5
0
Green
Black
White
DO NOT connect fan directly to building structure
White
Red
Control
Yellow
Motor
Blue
Green
Blue
Black or Brown
Power