PREFACE...............................................................................................1
CHAPTER 1 PRINCIPLE OF ENERGY SAVING...............................2
CHAPTER 2 FEATURES ......................................................................4
2.2 INSTRUCTION OF MODEL NO. ............................................................4
2.3 SPECIFICATIONS ................................................................................4
2.4 OVERALL DIMENSIONS......................................................................5
CHAPTER 3 INSTALLATION..............................................................6
3.1 INSTALLATION SITE...........................................................................6
3.2 PRECAUTIONS:..................................................................................6
3.3 MAIN CIRCUIT AND CONTROL CIRCUIT .............................................7
CHAPTER 4 OPERATION....................................................................8
4.1 SWITCHOVER BETWEEN POWER FREQUENCY AND ENERGY-SAVING .8
4.1.1 Running at energy-saving switching to power frequency......8
4.1.2 Running at power frequency switching to energy saving......8
4.2 TESTING STAGE OF THE CABINET......................................................9
4.3 NORMAL USING STAGE......................................................................9
4.4 KEYPAD OPERATION .................................................................10
4.4.1 KEYPAD FUNCTION ......................................................................10
4.4.2 KEYPAD BASIC OPERATION ..........................................................10
4.4.2.1 Direct display status..........................................................10
4.4.2.2 Switchover of display parameter.......................................10
CHAPTER 5 PARAMETERS..............................................................12
CHAPTER 6 TROUBLESHOOTING.................................................18
6.1 FAULT CODE AND REASON ANALYSIS ..............................................18
6.2 ADJUSTMENT OF DEFECTIONS.........................................................20
CHAPTER 7 MAINTENANCE...........................................................22
7.1 DAILY INSPECTION..........................................................................22
7.2 REGULAR MAINTENANCE................................................................22
7.3 PERIODIC MAINTENANCE................................................................23
7.4 STORAGE.........................................................................................23
0
User Manual of SY6000-Z series Preface
PREFACE
Thanks for choosing SY6000-Z series moulding injection
energy saving cabinet.
SY6000-Z series cabinet is high quality moulding injection energy saving drive which is designed according to IEC618000/IEC610000. The cabinet owns protection functions of phase-loss, over voltage, under voltage, over current, etc.
SY6000-Z series cabinet is suitable for kinds of moulding injection machine with hydraulic control proportional pump. It controls output power of motor according to pressure signal and flow signal of moulding injection machine to reach the objective of energy saving. The energy saving rate may get 25%~65%.
SY6000-Z series cabinet can work for pump motors which power ratings are from 11KW~55KW. It also can apply for one moulding injection machine with multiple pump motors.
Before using SY6000-Z series cabinet, in order to keep people in safe and acquire better energy-saving effect, please read the manual thoroughly. If you meet with tough problems when using, please contact us in time.
Please retain this manual and you will use it if necessary in future.
1
User Manual of SY6000-Z series Principle of energy-saving

Chapter 1 Principle of energy saving

Power consumption of moulding injection machine
mainly in the following sections:
Power consumption of hydraulic pump system;
Power consumption of heaters;
Power consumption of circulating cooling water pump
Electricity consumption of hydraulic pump accounts for 80% energy consumption of the injection molding machine, so reducing the power consumption is the key to save energy for molding injection machine.
The pressure and flow are changing when molding injection machine is in matching mould, cross locking, injection, material storing, cooling and other stages.
When oil need of the injection molding machine changes, the relief valve in pump outlet will adjust pressure and flow of the load, while the output motor power is the same, thus results in waste of energy.
According to requirements of pressure and speed at the current work status of moulding injection machine, such as stages of mold, lock cross, shooting rubber, material storage and cooling, SY6000-Z series cabinet can adjust automatically the pump speed the fuel supply to make actual fuel supply be consistent with actual load flow at any working stage.
Thus it eliminates overflowing of hydraulic oil, reduces pump output, and saves electricity consumption of pump motor, so as to achieve the best energy-saving state of moulding injection machine.
2
User Manual of SY6000-Z series Principle of energy-saving
3
User Manual of SY6000-Z series Features

Chapter 2 Features

2.1 SY6000-Z series cabinet is suitable for quantitative pump
moulding injection machine. Its features are as follows:
z Adopt advanced space voltage vector PWM control algorithm, with
advanced technology and low output current harmonic content, without power supply pollution
z With timing functions, cumulative working time can be recorded
under energy saving state.
z Adopt high-quality imported components, product quality assured z Excellent fault management and protection features make cabinet and
motor away from damage under no circumstance
z Large capacity of instantaneous impact current, up to 250%; overload
capacity 180% per minute
z No trip when the moulding injection machine is under high pressure
plastic injection and heavy load, so as do not affect production, ensure product quality
z Advanced integrated cabinet, with switchover of power frequency /
energy saving, with dedicated air channel, compact structure, easy to install
2.2 Instruction of model no.
2.3 Specifications
Voltage
class
380V
Model no.
SY6000-Z01140Y 11.0 24 3PH SY6000-Z01540Y 15.0 33
Power rating
(kW)
4
Rated output current
(A)
User Manual of SY6000-Z series Features
Voltage
class
Model no.
Power rating Rated output current
(kW) (A) SY6000-Z01840Y 18.5 39 SY6000-Z02240Y 22.0 44 SY6000-Z03040Y 30.0 60 SY6000-Z03740Y 37.0 75 SY6000-Z04540Y 45.0 90 SY6000-Z05540Y 55.0 110
2.4 Overall dimensions
Installation dimensions of SY6000-Z series AC Drives (unit: mm)
Voltage
class
Model no. W H H1 D D1
SY6000-Z01140Y SY6000-Z01540Y
320 630 660 200 225
SY6000-Z01840Y
3PH
380V
SY6000-Z02240Y SY6000-Z03040Y
390 780 810 300 325
SY6000-Z03740Y SY6000-Z04540Y
500 850 880 350 375
SY6000-Z05540Y
5
User Manual of SY6000-Z series Installation

Chapter 3 Installation

3.1 Installation site:
In order to get good performance and long lifespan, the installation site should meet the following conditions:
z Good indoor ventilation. z Ambient temperature-10 ~40 .℃℃ z Humidity less than 90%RH, without dew. z Don’t install in the combustibles such as woods. z Avoid direct sunlight. z No combustible, explosive, corrosive gases and liquids. z No ash dust, oil dust, floatable fibers and metal particles. z Strong installation base, no vibration. z No electromagnetic interference.

3.2 Precautions:

1. The cabinet applies for injection equipment which is dragged by general three-phase AC induction motor or inverter motor. Motor insulation class is B or above.
2. General three phase induction motor, which is driven by the cabinet, can not run in long term at low speed.
3. Capacitor, VDR and other RC absorbing devices are not allowed to connect with output terminals of the cabinets.
4. If there are contactors between the cabinet and the motor, must ensure that the cabinet doesn’t output when the contact switches, otherwise the cabinet may be damaged.
5. Installation environment should be well ventilated.
6. The cabinet should be used derating if the altitude is higher than1000 meters. Derate using 10% when the altitude rises 1500 meters.
7. Compare with running at power frequency, temperature rise and noise of the motor will increase slightly when use the cabinet. This is
6
User Manual of SY6000-Z series Installation
normal phenomenon.
8. The cabinet will be as industrial waste when scrap it, so please be careful:
(1) Inner polyester capacitors probably explode if set it on fire.
(2) Plastic pieces may produce toxic gases when burn it.
3.3 Main circuit and control circuit