SYRIS Technology SYRD245 1N M User Manual

SYRD245-1N-M
2.45 GHz RFID Network Reader
User Manual
Version 1.7
2007/04/23
SYRD245-1N-M active RFID Network Reader User Manual
. Product Specification
Communication 2.45 GHz Support read and write Frequency 2.40~2.48 GHz Channel 316 Address 65536 RSSI 0-255 LQI 0-255 Programmable Set Parameter LED Multi-LED visual indication Ethernet 10/100 base-T Ethernet (RJ-45) RS-232 RX, TX Protocols ICMP, ARP, IP, TCP(Server/Client), UDP, DHCP,
HTTP
Baud Rate 2,400 bps ~ 115,200 bps Power Input 7.5 VDC ~ 28 VDC Action Current MAX 300 mA @ 12 VDC Operating Temperature -20 oC to 65 oC, 5 to 95%RH Storage Temperature -30 oC to 85 oC, 5 to 95%RH Dimension 107W x 138H x 30D (mm)
1
SYRD245-1N-M active RFID Network Reader User Manual
. The Diagram of the System Connection
SYRD245-1N-M Network Reader can connect with 3 different interfaces RJ-45, RS-485 or RS-232.
SYRD245-1N-M connection to PC
2
SYRD245-1N-M active RFID Network Reader User Manual
. Install Network Enabler Administrator
1. Execute install program in SYRIS CD:
SYRIS Xtive CD-ROM\SYRD245-1\Driver\ Network Enabler Administrator 2.8 Setup.exe
2. Execute Network Enabler Administrator program after install.
3
SYRD245-1N-M active RFID Network Reader User Manual
. Setup Network Enabler Administrator
1. Click on Configuration from the menu bar, and then select Broadcast Search from the drop-down menu.
2. A Searching window will open, showing that the program is searching for network module connected to this network.
4
SYRD245-1N-M active RFID Network Reader User Manual
3. After the search is finished, all network module found will be shown in the right panel of the Configuration window. If you locate more than one module connected to this network, refer to the MAC address on the module(s) to determine which modules are the ones you wish to configure.
4. Double click selected network module you wish to configure, the Configuration window will open.
5
SYRD245-1N-M active RFID Network Reader User Manual
5. The Configuration window has 9 tabs: Basic, Network, Serial, Operating Mode, Accessible IPs, Auto Warning, IP Address Report, Password and Digital IO. SYRIS SYRD245-1N series will use 3 tabs in network module. (Network, Serial and Operating Mode), we will show more detail with these parts below.
6. Network: You must assign a valid IP address to network module before it will work in your network environment. Your network system administrator should provide you with an IP address and related settings for your network. The IP address must be unique within the network. You can choose from four possible IP Configuration modes: Static, DHCP, DHCP/BOOTP and BOOTP.
Method Function Definition Static User defined IP address, Netmask, Gateway. DHCP DHCP Server assigned IP address, Netmask,
Gateway, DNS, and Time Server
DHCP/BOOTP DHCP Server assigned IP address, Netmask,
Gateway, DNS, and Time Server, or BOOTP Server assigned IP address
BOOTP BOOTP Server assigned IP address
6
SYRD245-1N-M active RFID Network Reader User Manual
7
SYRD245-1N-M active RFID Network Reader User Manual
7. Serial: You should set up network module serial parameters as below diagram.
8