SYRD245-1N-M
2.45 GHz RFID Network Reader
User Manual
Version 1.7
2007/04/23
SYRD245-1N-M active RFID Network Reader User Manual
Ⅰ. Product Specification
Communication 2.45 GHz Support read and write
Frequency 2.40~2.48 GHz
Channel 316
Address 65536
RSSI 0-255
LQI 0-255
Programmable Set Parameter
LED Multi-LED visual indication
Ethernet 10/100 base-T Ethernet (RJ-45)
RS-232 RX, TX
Protocols ICMP, ARP, IP, TCP(Server/Client), UDP, DHCP,
HTTP
Baud Rate 2,400 bps ~ 115,200 bps
Power Input 7.5 VDC ~ 28 VDC
Action Current MAX 300 mA @ 12 VDC
Operating Temperature -20 oC to 65 oC, 5 to 95%RH
Storage Temperature -30 oC to 85 oC, 5 to 95%RH
Dimension 107W x 138H x 30D (mm)
1
SYRD245-1N-M active RFID Network Reader User Manual
Ⅱ. The Diagram of the System Connection
SYRD245-1N-M Network Reader can connect with 3 different interfaces:
RJ-45, RS-485 or RS-232.
SYRD245-1N-M connection to PC
2
SYRD245-1N-M active RFID Network Reader User Manual
Ⅲ. Install Network Enabler Administrator
1. Execute install program in SYRIS CD:
SYRIS Xtive CD-ROM\SYRD245-1\Driver\ Network Enabler Administrator 2.8 Setup.exe
2. Execute Network Enabler Administrator program after install.
3
SYRD245-1N-M active RFID Network Reader User Manual
Ⅳ. Setup Network Enabler Administrator
1. Click on Configuration from the menu bar, and then select Broadcast
Search from the drop-down menu.
2. A Searching window will open, showing that the program is searching for
network module connected to this network.
4
SYRD245-1N-M active RFID Network Reader User Manual
3. After the search is finished, all network module found will be shown in the
right panel of the Configuration window. If you locate more than one
module connected to this network, refer to the MAC address on the
module(s) to determine which modules are the ones you wish to configure.
4. Double click selected network module you wish to configure, the
Configuration window will open.
5
SYRD245-1N-M active RFID Network Reader User Manual
5. The Configuration window has 9 tabs: Basic, Network, Serial, Operating
Mode, Accessible IPs, Auto Warning, IP Address Report, Password and
Digital IO.
SYRIS SYRD245-1N series will use 3 tabs in network module. (Network,
Serial and Operating Mode), we will show more detail with these parts
below.
6. Network: You must assign a valid IP address to network module before it
will work in your network environment. Your network system administrator
should provide you with an IP address and related settings for your
network. The IP address must be unique within the network. You can
choose from four possible IP Configuration modes: Static, DHCP,
DHCP/BOOTP and BOOTP.
Method Function Definition
Static User defined IP address, Netmask, Gateway.
DHCP DHCP Server assigned IP address, Netmask,
Gateway, DNS, and Time Server
DHCP/BOOTP DHCP Server assigned IP address, Netmask,
Gateway, DNS, and Time Server, or BOOTP Server
assigned IP address
BOOTP BOOTP Server assigned IP address
6
SYRD245-1N-M active RFID Network Reader User Manual
7
SYRD245-1N-M active RFID Network Reader User Manual
7. Serial: You should set up network module serial parameters as below
diagram.
8