. Product Specification
Communication 2.45 GHz Support read and write Frequency 2.40~2.48 GHz Channel 316 RSSI 0-255 LQI 0-255 Programmable Set Parameter LED Multi-LED visual indication RS232 RX, TX RS485 +, ­Wiegand formats 26 bits, 34 bits, 42 bits Baud Rate 2,400 bps ~ 115,200 bps Power Input 7 VDC ~ 15 VDC Action Current MAX 500 mA @ 12 VDC Operating Temperature -20 oC to 65 oC, 5 to 95%RH Storage Temperature -30 oC to 85 oC, 5 to 95%RH Dimension 107W x 138H x 30D (mm)
1
SYRD245-1W active RFID Reader User Manual
. The Diagram of the System Connection
SYRD245-1W Reader can connect with 3 different interfacesRS-485 or Wiegand or RS-232.
2
SYRD245-1W active RFID Reader User Manual
. Use SYRD245-1W Reader Config software
Execute SYRD245_1W_Tools_V0196.exe in SYRIS Xtive DVD-ROM\SYRD245-1\Utility\
3
SYRD245-1W active RFID Reader User Manual
1. Scan Reader to get readers serial number and firmware version.
2. Adjust the ID number and then click Set Reader ID to change Readers ID.
3. Select communication Baud rate and then click Set Baud rate to change Readers Baud rate.
4. Adjust the number of Sec to set same card interval.
Ex. Set Same card interval to 10 sec. Reader will not receive same tag between 10 sec.
5. Set DI NO/NC to change RELAY ON/OFF mode.
6. Set reader mode to Wiegand or RS485
4
SYRD245-1W active RFID Reader User Manual
7. Click Read TAG to receive TAG information.
8. Adjust RSSI level (0~250) to filter TAG which have low RSSI signal in reader.
(This function was available in version 1.30 or above.)
Ex. Set RSSI Level to 120, Reader will receive tag which RSSI are stronger than
120.
9. Set Gain (1~13) to control readers read range. Level 13 is the max range (default setting), Level 1 is the shortest read range.
10. Set Exciter ID (This function was available in version 2.03 or above.) : This parameter should use with SYRIS exciter, default values are 0000 means disable. If this function enable, reader will only receive tags signal which include set exciter ID.
11. Reader Reset: Reset online reader. Reader will warm restart. Factory Default: All setting will set factory default.
5
SYRD245-1W active RFID Reader User Manual
FCC Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by SYRIS Technology Corp. Could void the user's authority to operate this equipment.
6